• Title/Summary/Keyword: Nitrate ion

Search Result 337, Processing Time 0.025 seconds

Degradation of the Chlorothalonil by Functional Zeolite-KCIO3 Complex (기능성 Zeolite-KCIO3 복합체에 의한 Chlorothalonil의 분해)

  • Choi, Choong-Lyeal;Park, Man;Lee, Dong-Hoon;Lee, Byung-Mook;Rhee, In-Koo;Choi, Jyung;Kim, Jang-Eok
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.2
    • /
    • pp.111-116
    • /
    • 2004
  • Salt occlusion in Zeolite is a unique phenomenon that takes place only when the salt size is similar to the window size of host zeolite. $KCIO_3$-occluded Zeolite, as an environment-friendly oxidant, has a high potential for effective removal of various organic pollutants. This study was carried to investigate the characteristics and the removal kinetics of fungicide chlorothalonil by zeolite-$KCIO_3$ complex. About 10% of $KCIO_3$ was occluded in zeolite pores synthesized by salt-thermal method from fly ash, although the occlusion amount was relatively less compared to that of nitrate salts. By occlusion with $KCIO_3$, no remarkable changes were found in X-ray diffraction patterns of cancrinite, whereas some decrease of overall peak intensities was found with those of sodalite. Different releasing kinetics of $CIO_3^-$ ion were observed in distilled water and soil solution from zeolite-$KCIO_3$ complex. Two reactions, hydration and diffusion, seem to be related with the release of $KCIO_3$. Therefore, the release isotherm of $CIO_3^-$ ion well fitted to the power function model which indicate the release was made by hydration and diffusion. The removal of chlorothalonil by zeolite and $KCIO_3$ reached at reaction equilibrium within 6 hours by 18% and 47% respectively. However, the chlorothalonil removal by the zeolite-$KCIO_3$ complex increased slowly and steadily up to 92% in 96 hours. These findings suggested that zeolite-$KCIO_3$ complex could be applied for effective removal of organic contaminants in the soil and aqueous environment.

The Study of Water Characteristics of Drinking Underground Water in the West Gyeong-Nam (서부경남지역 음용 지하수의 수질특성에 관한 고찰)

  • Park, Hyun Geoun;Jung, Youn Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.3
    • /
    • pp.192-197
    • /
    • 2014
  • Water analyses were conducted on 1,525 underground water laid in the western district of Korea's South Gyeongsang Province, from January 2007 until July 2010, according to sections, factors, fountainheads and inter-factor correlativities. The following are the results. 1. As a result of local incongruity rate, 18.2% in inland areas, coastal areas and 24.5% showed a high value comparatively. Costal areas showed high incongruity rate. 2. As a result of local incongruity rate, they were found that the total colony count and general bactria 39.9%, 42.6% showed a high in costal areas. 3. As a result of local factorial inspection, it was found that the turbidity content counted up to 0 to 0.2 NTU in 59.4% in inland areas, 60.2% in costal areas of sections, and in other 12.6%, 14.0%, it exceeded 0.5 NTU. As a result of local factorial inspection, it was found that the nitrate-nitrogen content counted up to 0 to 10 mg/L in 98.2% in inland areas, 97.6% in costal areas of sections, and in other 1.8%, 2.4%, it exceeded 10 mg/L. As regards chloride in coastal areas, water quality standards for chloride 250 mg/L exceeds the 1.4% higher then in inland areas. 4. Hardness in inland areas was closely correlated with total solids (r = 0.910), sulfate ion (r = 0.819). Also, total solids and boron (r = 0.600) showed high correlativities. On the other hand hardness in coastal areas was closely correlated with total solids (r = 0.919), chloride (r = 0.829). Also sulfate ion was closely correlated with hardness (r = 0.599), turbidity and aluminum (r = 0.635) showed high correlativities in this research.

The Performance Evaluation of Blended Fertilizers as Draw Solution in Forward Osmosis Desalination (유도용액으로 혼합비료를 사용한 정삼투식 해수담수화에서 혼합비료의 성능평가)

  • Kim, Seung-Geon;Lee, Ho-Won
    • Membrane Journal
    • /
    • v.28 no.1
    • /
    • pp.45-54
    • /
    • 2018
  • This study is to find the optimum draw solution in fertilizer-drawn forward osmosis desalination. Considering osmotic pressure, solubility, and pH, 20 blended fertilizers were screened. Their performance were evaluated in terms of pure water permeate flux, reverse solute flux, and specific reverse solute flux for nitrogen, phosphorus, and potassium. The pure water permeate flux of blended fertilizers including KCl were relatively higher. The reverse solute flux and specific reverse solute flux for nitrogen of blended fertilizers containing ${NO_3}^-$ ion were relatively higher than those of the nitrate ion-free draw solution. Those for phosphorus, and potassium of blended fertilizers including $NH_4H_2PO_4$, and $KNO_3$ were relatively higher than those of the phosphorus-free, and potassium-free draw solution, respectively. The blended fertilizer of $NH_4H_2PO_4$ and KCl contains all of nitrogen, phosphorus and potassium which are essential elements of fertilizer, and has the relatively high water permeation flux and the low reverse solute flux for nitrogen, phosphorus, and potassium. Therefore, it is the most effective draw solution for fertilizer-drawn forward osmosis desalination.

THE EFFECT OF MOISTENING OF ETCHED DENTIN AND ENAMEL SURFACE ON THE MICROLEAKAGE OF COMPOSITE RESINS (복합레진 수복시 상아질 표면 처리가 미세 변연 누출에 미치는 영향에 관한 연구)

  • Jeon, Cheol-Min;Kwon, Hyuk-Choon;Lee, Chung-Sik;Lee, Myung-Jon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.321-338
    • /
    • 1996
  • The purpose of this study was to evaluate the effect of moistening and air-drying of acid conditioned dentin and enamel on the marginal microleakage. In this study, Class V cavity were prepared on both buccal and lingual surface of sixty extracted human premolars with cementum margin. These specimens were randomly devided into three groups and three dentin adhesives(Scotchbond Multi-Purpose, All bond 2, Prisma Universal Bond 3) were applied to each group. The specimens in each group were subdevided into four groups (Wet/primed, Dry/primed, Wet/not primed, Dry/not primed) and the etched dentin and enamel surface were treated these four surface treatments prior to the placement of a bonding agent or adhesive. Wet/primed group was simply blot-dried with a damp facial tissue before primer placement ; Dry/primed group was air dried for 30 seconds before the placement of a primer ; Wet/not primed group and Dry/not primed group were not primed after blot dried and air dried for 30 seconds each group. The bonding agent and composite resin were applied for each group. All specimens were exposed to 500 cycle of thermal stress. Specimens were placed in a silver nitrate solution and then sectioned buccolingually through the center of the restoration. The dye penetrations of the specimens were observed with a stereo microscope. The statistical test were applied to the results using a one way analysis variance (ANOVA) and Duncan's multiple range test. The aspects of silver ion penetration into the resin/dentin interface were examined under scanning electron microscopy. The results were as follows. 1. In all groups, the enamel margin showed significantly lower leakage value than the cementum margin (p<0.05). 2. Regardless of various surface treatment and dentin adhesives, there was no significant difference at the enamel margins (p>0.05). 3. At the dentin margins, the leakage values of Dry/not primed group showed significantly higher than that of the other groups (p<0.05). The leakage values of Wet/primed group showed significantly lower than that of the other groups, but, there was no significant difference between Wet group and Dry group. 4. There was no significantly difference between the dentin adhesives regarding the surface treatments in all groups(p>0.05). 5. On the backscatterd scanning electron microscopy observation, the penetration of the silver ion occured at the bonding resin/dentin interface. In the Wet/primed group, resindentin hybrid zone and resin penetration into the dentin was observed. The resin tags were compactively formed to a thickness of $3\sim4{\mu}m$ at the upper part of dentinal tubules. In the Dry/primed group, the thickness of the hybrid zone and the diameter, depth of the resin tags diminished. In the Non-primed groups, the hybrid zone was not identified and few resin tag was observed. There was the gap formation in the resin/dentin interface.

  • PDF

Study on Recovery of Precious Metal (Ag, Au) from Anode Slime Produced by Electro-refining Process of Anode Copper (양극동의 전해정련시 발생된 양극슬라임으로부터 귀금속(Ag, Au) 회수에 대한 연구)

  • Kim, Young-Am;Park, Bo-Gun;Park, Jae-Hun;Hwang, Su-Hyun
    • Resources Recycling
    • /
    • v.27 no.6
    • /
    • pp.23-29
    • /
    • 2018
  • Recently rapid economic growth and technological development have led to an increase in the generation of waste electrical and electronic equipment (WEEE). As the amount of electric and electronic waste generated increases, the importance of processing waste printed circuit boards (PCB) is also increasing. Various studies have been conducted to recycle various valuable metals contained in a waste PCB in an environmentally friendly and economical manner. To get anode slime containing Ag and Au, Anode copper prepared from PCB scraps was used by means of electro-refining. Ag and Au recovery was conducted by leaching, direct reduction, and ion exchange method. In the case of silver, the anode slime was leached at 3 M $HNO_3$, 100 g/L, $70^{\circ}C$, and Ag was recovered by precipitation, alkali dissolution, and reduction method. In the case of gold, the nitrate leaching residues of the anode slime was leached at 25% aqua regia, 200 g/L, $70^{\circ}C$, and Au was recovered by pH adjustment, ion exchange resin adsorption, desorption and reduction method. The purity of the obtained Au and Ag were confirmed to be 99.99%.

Chemical and Bacteriological Quality of Spring Waters in Pusan Area (부산시내 약수의 화학적 및 세균학적 수질에 관한 연구)

  • KIM Yong-Gwan;KOH Kwang-Bae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.19 no.2
    • /
    • pp.169-175
    • /
    • 1986
  • This study was carried out to evaluate the water quality of spring waters in Pusan area (see Fig. 1). In this experiment, one hundred and forty water samples were collected at 20 stations from July to December 1985. Range and mean value of constituents of the samples were as follows ; pH 6.2-8.2, 7.07 ; water temperature $4.0-23.5^{\circ}C,\;15.9^{\circ}C$ ; electrical conductivity $0.228{\times}10^{2}-2.125{\times}10^2{\mu}{\mho}/cm,\;0.860{\times}10^2{\mu}{\mho}/cm$; chloride ion 3.28-19.3mg/l, 6.81mg/l ; nitrite-nitrogen ND-0.221 mg/l, 0.017mg/l ; nitrate-nitrogen ND-6.779mg/l, 0.877 mg/l ; phosphate-phosphorus ND-0.105mg/l, 0.021mg/l ; silicate-silicious 2.12-22.70mg/l, 9.04mg/l, respectively. Especially, electrical conductivity, chloride ion, nitrite-nitrogen, nitrate-nitrogen, and silicate-silicious of the station 11 (Millakdong) were higher than those of others as $1.815{\times}10^2{\mu}{\mho}/cm$, 13.5mg/l, 0.076mg/l, 4.772mg/l and 14.07mg/l. Range and geometric mean value of total coliform and fecal coliform MPN's of the samples were 0-1,500/100ml, 13-470/100ml and 0-460/100ml, 2-32/100ml. Composition of coliform was $26.37\%$ Escherichia coli group, $21.98\%$ Citrobacter freundii group, $37.36%$ Entrobacter aerogenes group and $14.29\%$ others.

  • PDF

Development of Extracting Solution for Soil Chemical Analysis Suitable to Integrated Ion-selective Micro-electrodes (집적형 이온선택성 미세전극 센서에 적합한 토양화학 분석용 침출액 종 개발)

  • Shin, Kook-Sik;Lim, Woo-Jin;Lee, Sang Eun;Lee, Jae Seon;Cha, Geun Sig
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.6
    • /
    • pp.513-521
    • /
    • 2009
  • The primary goal of this research was to develop an optimized analytical procedure for soil analysis based on ion-selective microelectrodes for agricultural purposes, which can perform on-site measurement of various ions in soil easily and rapidly. For the simple and rapid on-site diagnosis, an analysis of soil chemicals was performed employing a multicomponent-in-situ-extractant and an evaluation of ionselective microelectrodes were conducted through the regressive correlation method with a standard analytical approach widely employed in this area. Examination of sensor responses between various soil nutrient extractants revealed that 0.01M HCl and 1M LiCl provided the most ideal Nernstian response. However, 1M LiCl deteriorated the selective response for analytes due to high concentration (1M) of lithium cation. Thus, employing either 0.1M HCl as an extractant followed by 10 times dilution, or 0.01M HCl as an extractant without further dilution was chosen as the optimal extractant composition. A study of regressive correlation between results from ion-selective microelectrodes and those from the standard analytical procedure showed that analyses of $K^+$, $Na^+$, $Ca^{2+}$, and $NO_3{^-}$ showed the excellent consistency between two methods. However, the response for $NH_4{^+}$ suffered the severe interference from $K^+$. In addition, the selectivity for $Mg^{2+}$ over $Ca^{2+}$ was not sufficient enough since available ionophores developed so far do not provide such a high selectivity for $Mg^{2+}$. Therefore, as an agricultural on-site diagnostic instrument, the device in development requires further research on $NH_4{^+}$ analysis in the soil sample, development of $Mg^{2+}$-selective ionophore, and more detailed study focused on potassium, one of the most important plant nutrients.

Water Quality of Some Spring Waters in Pusan Area (부산시내에 산재하는 몇몇 약수터 약수의 수질)

  • KIM Yong-Gwan;CHO Hyeon-Seo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.6
    • /
    • pp.538-544
    • /
    • 1985
  • This study was carried cut to evaluate the water quality of spring waters in Pusan area(see Fig. 1). In this experiment, twenty-five water samples were collected from 5 stations from December 1983 to August 1984. Range and mean values of constituents of the samples are as follows: pH $5.80{\sim}7.25$, 6.60; water temperature $6.0{\sim}23.0^{\circ}C,\;12.9^{\circ}C$; total residue $33.0{\sim}325mg/l$, 121.2mg/l; alkalinity $4.75{\sim}51.6mg/l$, 24.1mg/l; hardness $9.47{\sim}85.0mg/l$, 30.3mg/l; electrical conductivity $0.495{\sim}2.750{\times}^2{mu}{\mho}/cm,\;1.239{\times}10^2{\mu}{\mho}/cm$;turbidity $0.54{\sim}7.80$NTU, 2.04NTU; $KMnO_4$ consumed $0.51{\sim}8.47mg/l$, 1.96mg/l; chloride ion $4.91{\sim}36.0mg/l$, 12.55mg/l; fluoride ion ND-0.30ppm, 0.08ppm; nitrate-nitrogen ND-8.94mg/l, 1.94m:g/l; nitrite-nirogen ND-0.10mg/l, 0.03mg/l; ammonia-nitrogen ND-0.16mg/l, 0.03mg/l: phosphate-phosphorus ND-0.09mg/l, 0.03mg/l; silicate-silicious $0.42{\sim}22.7ng/l$, 7.96mg/l; copper ND-10.5ppb, 2.46ppb; lead ND-22.7ppb, 3.54ppb; zinc ND-103ppb, 21.33ppb; iron $20.3{\sim}2,800ppb$, 801.72ppb, respectively. Arsenic, cyan, cadmium, manganese, mercury, chrome and phenol were not detected. Total residue, electrical conductivity, turbidity and chloride ion of station 1 (Milrakdong) were higher than others as 178.1mg/l, $2.127{\times}10^2{\mu}{\mho}/cm$, 3.16NTU and 16.32mg/l. The concentration of silicious had a great influence on precipitation. The concentration of fluoride ion of spring waters was lower as 0.08ppm than the criterion for drinking water as 1ppm, while iron was exceed 2.7 times as 801.72ppb.

  • PDF

Snow Influence on the Chemical Characteristics of Winter Precipitation (강설이 겨울철 강수의 화학적 특성에 미치는 영향)

  • Kang, Gong-Unn;Kim, Nam-Song;Oh, Gyung-Jae;Shin, Dae-Yewn;Yu, Du-Cheol;Kim, Sang-Baek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.1
    • /
    • pp.113-125
    • /
    • 2007
  • To know the differences in ionic compositions in rain and snow as well as snow influence on the chemical characteristics of winter precipitation, precipitation samples were collected by the wet-only automatic precipitation sample, in winter(November-February) in the Iksan located in the northwest of Chonbuk from 1995 to 2000. The samples were analyzed for concentrations of water-soluble ion species, in addition to pH and electrical conductivity. The mean pH of winter precipitation was 4.72. According to the type of winter precipitation, the mean pH of rain was 4.67 and lower than 5.05 in snow. The frequencies of pH below 5.0 in rain were about 73%, while those in snow were about 30%. Snow contained 3 times higher concentrations of sea salt ion components originated from seawater than did rain in winter, mainly $Cl^-,\;Na^+$, and $Mg^{2+}$. Neglecting sea salt ion components, $nss-SO_4^{2-}$ and $NO_3^-$ were important anions and $NH_4^+$ and $nss-Ca^{2+}$ were important cations in both of rain and snow. Concentrations of $nss-SO_4^{2-}$ was 1.3 times higher in rain than in snow, while those of $nss-Ca^{2+}$ and $NO_3^-$ were 1.5 and 1.3 times higher in snow, respectively. The mean equivalent concentration ratio of $nss-SO_4^{2-}/NO_3^-$ in winter precipitation were 2.4, which implied that the relative contribution of sulfuric and nitric acids to the precipitation acidity was 71% and 29%, respectively. The ratio in rain was 2.7 and higher than 1.5 in snow. These results suggest that the difference of $NO_3^-$ in rain and snow could be due to the more effective scavenging of $HNO_3$ vapor than particulate sulfate or nitrate by snow. The lower ratio in snow than rain is consistent with the measurement results of foreign other investigators and with scavenging theory of atmospheric aerosols. Although substantial $nss-SO_4^{2-}$ and $NO_3^-$ were observed in both of rain and snow, the corresponding presence of $NH_4^+,\;nss-Ca^{2+},\;nss-K^+$ suggested the significant neutralization of rain and snow. Differences in chemical composition of non-sea salt ions and neutralizing rapacity of $NH_4^+,\;nss-Ca^{2+}$, and $nss-K^+$ between rain and snow could explain the acidity difference of rain and snow. Snow affected that winter precipitation could be less acidic due to its higher neutralizing rapacity.

Chemical and Bacteriological Water Qualify of the Sonakdong River (서낙동강 강수의 화학적${\cdot}$세균학적 수질)

  • KIM Yong Gwan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.19 no.4
    • /
    • pp.347-355
    • /
    • 1986
  • The Sonakdong river is very important water source not only for agricultural water of Kimhae field but also for fishery water. Recently the middle and lower areas of the river have the tendency to be heavily contaminated by domestic sewage and agricultural chemicals. Fifty six water samples were collected from 8 stations from July to December in 1985 for the experiment (Fig. 1). To evaluate the water quality, pH, water temperature, electrical conductivity, chloride ion, nutrients ($NO^{-}_{2}-N,\;NO^{-}_{3}-N,\;NH^{+}_{4}-N,\;PO^{3-}_{4}-P,\;SiO_2-Si$), total coliform, fecal coliform, and fecal streptococcus were determined. Range and mean value of the samples were as follows; pH $6.3{\sim}9.4$, 7.91; water temperature $6.1{\sim}34.8^{\circ}C,\;23.88^{\circ}C$; electrical conductivity (from St. A to G) $1.575{\times}10^2{\sim}30.50{\times}10^2{\mu}{\mho}/cm,\;6.57{\times}10^2{\mu}{\mho}/cm$; chloride ion $23.5{\sim}14,300mg/l$, 770.0mg/l; nitrite-nitrogen $0.007{\sim}0.110mg/l$, 0.053mg/l; nitrate-nitrogen $0.001{\sim}1.638mg/l$, 0.649 mg/l; ammonia-nitrogen $0.017{\sim}4.200mg/l$, 0.497mg/l; phosphate-phoshorus $0.011{\sim}0.281mg/l$, 0.086mg/l; and silicate-silicious $2.4{\sim}6.5mg/l$, 4.43mg/l. Electrical conductivity and chloride ion of the station F(Chomanpo) were $2.676{\times}10^2{\mu}{\Omega}cm$ and 123.99mg/l which were lower than those of others. Among the analyzed nutrients, silicate-silicious concentration was the highest through all the samples. The bacterial density of the samples ranged $36{\sim}110,000/100ml$ for total coliform, $15{\sim}46,000/100ml$ for fecal coliform and $3.6{\sim}15,000/100ml$ for fecal streptococcus. The range and the mean of the TC/FC ratio were $3.0{\sim}9.6$, 5.51 and those of the FC/FS ratio were $1.1{\sim}9.2$, 6.19, respectively. On the other hand, fecal coliform was not detected in about $78\%$ of the water samples examined. Composition of coliform was $52\%$ Escherichia coli group, $3\%$ Citrobacter freundii group, $13\%$ Enterobacter aerogenes group and $31\%$ others.

  • PDF