• Title/Summary/Keyword: Nickel-chromium

Search Result 211, Processing Time 0.03 seconds

Evaluation of Chromium and Manganese Exposure in Welders and Establishment of Efficient Preventive Measures for Fume Exposure (철강용접자의 크롬 및 망간 노출평가와 산업위생관리 대책에 관한 연구)

  • Lee, Young-Sei;Yoon, Chong-Guk;Park, Jong-An;Lee, Song-Kwon;Chae, Jong-Hong;Kim, Ek-Soo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.45-57
    • /
    • 2000
  • Results of environmental monitoring for 35 steel industry welders exposed to manganese and chromium fume were evaluated. Efficiency of respiratory protectors, welding face shields and local exhaust ventilation were also evaluated to establish more efficient preventive measures that can protect welders from occupational disease as related to welding fume. The results are as follows; 1. Total fume from $CO_2$ arc welding with mild steel occurred 1.5 to 2.2 times more than that from shielded metal arc welding. Chromium and nickel fume from welding with stainless steel occurred 27 to 59 times and 18 to 30 times, respectively, than those with mild steel. 2. Proportions of water-soluble chromium(VI) and insoluble chromium(VI) Compare to total chromium occurring from $CO_2$ arc welding with stainless steel were 10.5% and 8.7%, respectively, while those with mild steel were 57.1 to 63.2% and 31.6 to 38.1%, respectively. 3. The efficiencies of 4 types of respiratory protectors to reduce welding fume exposure were evaluated as 54.4 to 64.4%. 4. The reducing effect of head type welding face shield was 67.6%, and that of hand type welding face shield was 58.5%. The highest reducing effect was shown in air supply welding face shield as 99.2%, although it is not convenient to wear. 5. When welding face shield and respiratory protectors were worn together, the reducing efficiency increased to 79.0 to 87.5%. 6. When local exhaust ventilation was installed in workplace, the reducing efficiencies varied from 31.5 to 73.1% according to the types of welding.

  • PDF

Effect of long-term thermal aging on the microstructural and mechanical characteristics of nickel-based alloy weldment (니켈계 합금 용접부의 미세조직 및 기계적 특성에 대한 장기 열적 시효의 영향)

  • Yoo, Seung Chang;Ham, Junhyuk;Kim, Ji Hyun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.41-48
    • /
    • 2016
  • To investigate the effect of long-term thermal aging on the microstructural and mechanical characteristics of weldment made of nickel base alloy and its weld metal, an accelerated heat treatment was applied to simulate the process of long-term thermal aging in the operating condition of nuclear power plant. A representative nickel-based weldment with Alloy 600 and Alloy 182 was fabricated and heat-treated at $400^{\circ}C$ for 1,713 h and 3,427 h to simulate the thermal aging for the period equivalent to 15 and 30 years in operating pressurized water reactors, respectively. The microstructural and mechanical characteristics were analyzed by using optical microscopy, scanning electron microscopy and Vickers microhardness measurement. Changes were observed in precipitation behavior and microhardness of each specimen, and these changes were mainly attributed to the change in precipitated morphology and residual stress across the weld during the thermal aging process.

Preliminary Investigation on Joining Performance of Intermediate Heat Exchanger Candidate Materials of Very High Temperature Reactor(VHTR) by Vacuum Brazing (진공 브레이징을 이용한 고온가스냉각로 중간 열교환기 후보재료의 접합성능에 관한 예비시험)

  • Kim, Gyeong-Ho;Kim, Gwang-Ho;Lee, Min-Gu;Kim, Heung-Hoe;Kim, Seong-Uk;Kim, Suk-Hwan
    • Proceedings of the KWS Conference
    • /
    • 2005.11a
    • /
    • pp.195-197
    • /
    • 2005
  • An intermediate heat exchanger(IHX) is a key component in a next-generation VHTR with process heat applications such as hydrogen production and also for an indirect gas turbine system. Therefore, high temperature brazing with nickel-based filler metal(MBF-15) was carried out to study the joining characteristic(microstucture, joining strength) of nickel-based superalloy(Haynes 230) by vacuum brazing. The experimental brazing was carried out at the brazing process, an applied pressure of about 0.74Mpa and the three kinds of brazing temperatures were 1100, 1150, and $1190^{\circ}C$ with holding time 5 minute. It's joining phenomena were analyzed by optical microscopy and scanning electron microscopy with EPMA. The results of microstructure in the centre-line region of a joint brazed with MBF-15 show a typical ternary eutectic of v-nickel, nickel boride and chromium boride.

  • PDF

Composition and Mechanical Properties of Nickel Deposit Obtained from Electroless Nickel Plating Bath Contained Triethanolamine as Complexing Agent (트리에탄올아민을 착화제로 사용한 무전해 니켈도금욕에서의 석출물의 조성 및 기계적 성질)

  • Yeo, Woon-Kwan;Moon, In-Hyung
    • Journal of the Korean institute of surface engineering
    • /
    • v.19 no.2
    • /
    • pp.31-43
    • /
    • 1986
  • The properties of the electroless nickel deposit mainly depends on the pH of the bath, the plating temperature, and the molar ratio of nickel to hypophosphite but they are also affected by its formulation and concentration of complexing and buffering agents. According to changeing the concentration of triethanolamine and boric acid, phosphorous contents, microsturcture, crystalline, hardness and wear resistance of deposits obtained from ammoniacal alkaline bath were investigated by EPMA, differential thermal analyser, X-ray diffractometer and wear tester. The results are as follows; (1) Increasing concentration of triethanolamine in the bath, the deposits is slightly inclined to increase its phosphorous content(3.7% P). (2) In the as-plated state, the deposits are not crystallized state but they are thermally unstable phase, and they are crystallized with precipitating $Ni_3P$ at 400$^{\circ}C$. (3) The deposit containing 2.3% P has higher hardness value in the as plated and heat treated state at below 300$^{\circ}C$ than those of 3.7% phosphorous deposit (1090Hk). But in the case of heat treating at 400$^{\circ}C$, the former has lower hardness value (1000Hk) than the latter and has remarkably Ni(III) orientation by heat treatment. (4) The 3.7% phosphorous deposit heat treated at 400$^{\circ}C$ has better wear resistance than hard chromium plating.

  • PDF

Pretreatment Effect on the Analysis of Insoluble Hexavalent Chromium (전처리방법에 따른 불용성 6가 크롬 분석에 관한 연구)

  • Lee, Eun Jung;Roh, Jae Hoon;Won, Jong Uk;Chun, Mi Ryonng;Cho, Myung Hwa;Kim, Chi Nyon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.292-300
    • /
    • 1996
  • Hexavalent chromium($Cr^{+6}$) compounds are considered to be particularly hazardous, primarily because of the associated risk of allergic reaction and cancer. The analytic method of hexavalent chromium such as the s-diphenylcarba-zide(DPC) method and all ether previously used methods are often made uncertain due to significant interferences from organic components. This report can provide a technique for the more rapid and simple determination of total hexavalent chromium. than other currently using methods. The s-diphenylcarbazide method proposed by the U.S. National Institute for Occupational Safety and Health has low recovery rate(15.67 - 48.20%) due to interference, iron chloride and nickel chloride. A microwave oven technique has high recovery rate(about 70%) of insoluble hexavalent chromium. For the difference of ionic charges of $Cr^{+3}$-ethylenediamine tetraacetic acid(EDTA) chelate and $CrO_4{^{-2}}$, we could detect them simultaneously by ion exchanged high performance liquid chromatography. The confirmation of $Cr^{+3}$ and $Cr^{+6}$ were checked by fraction collector and flameless atomic absorption spectrometer. We observed that the small amount of hexavalent chromium is converted to trivalent chromium due to enhancement of chromium reduction by $Fe^{+3}$ or $Ni^{+2}$. As a result of this study, on the analysis of insoluble hexavalent chromium with microwave oven was used for, it may be better and more precise analysis after pretreatment by 2% NaOH-3% $Na_2CO_3$ and then analysis UV-spectrophotometer. It should be done for various studies on insoluble hexavalent chromium on the basis work environmental monitoring so called welding, painting etc.

  • PDF

Physico-mechanical properties and prosthodontic applications of Co-Cr dental alloys: a review of the literature

  • Al Jabbari, Youssef S.
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.138-145
    • /
    • 2014
  • Cobalt-Chromium (Co-Cr) alloys are classified as predominantly base-metal alloys and are widely known for their biomedical applications in the orthopedic and dental fields. In dentistry, Co-Cr alloys are commonly used for the fabrication of metallic frameworks of removable partial dentures and recently have been used as metallic substructures for the fabrication of porcelain-fused-to-metal restorations and implant frameworks. The increased worldwide interest in utilizing Co-Cr alloys for dental applications is related to their low cost and adequate physico-mechanical properties. Additionally, among base-metal alloys, Co-Cr alloys are used more frequently in many countries to replace Nickel-Chromium (Ni-Cr) alloys. This is mainly due to the increased concern regarding the toxic effects of Ni on the human body when alloys containing Ni are exposed to the oral cavity. This review article describes dental applications, metallurgical characterization, and physico-mechanical properties of Co-Cr alloys and also addresses their clinical and laboratory behavior in relation to those properties.

The importance of assessing heavy metals in medicinal herbs: a quantitative study

  • Behera, Bhagyashree;Bhattacharya, Sanjib
    • CELLMED
    • /
    • v.6 no.1
    • /
    • pp.3.1-3.4
    • /
    • 2016
  • Consumption of herbal products from the medicinal plants contaminated with heavy metals can cause serious consequences on human health. This is a major concern for traditional and herbal medicine. The present study was carried out to analyze and quantify the levels of six potentially toxic heavy metals namely arsenic, lead, cadmium, mercury, chromium and nickel in ten important Indian medicinal herbs. The air dried raw herbs were processed by microwave assisted wet digestion and analyzed by using atomic absorption spectrophotometer equipped with graphite tube atomizer. Except the chromium content in three plants, all the levels of six heavy metals analyzed were found to be quite below the permissible limits in all the ten raw medicinal herbs analyzed. The present work implies that, regular and systematic screening of raw medicinal herbs is necessary to check the levels of the heavy metal contaminants before using them for consumption or preparation of herbal formulations so that the possible contamination cannot cumulate up to the finished products.

Study on Diffusion Bonding of Stainless Steel to Mild Steel (연강-스테인리스강의 확산접합에 관한 연구)

  • Kim, S.T.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.11 no.1
    • /
    • pp.17-26
    • /
    • 1998
  • Cladding of stainless steel on mild steel was prepared by diffusion bonding process. The bond strength increased with an increase of bonding temperature and time. It was also found that the bond strength increased as the surface roughness decreased. After the diffusion bonding of stainless steel-mild steel, the mild steel part near the bonded interface showed higher strength than the base steel due to the migration of chromium and nickel from stainless steel to mild steel. Carbon migration from mild steel gave effect on the formation of chromium carbides at grain boundaries of stainless steel, the fractograpohic features of the imperfectly bonded interface showed rather coarse dimples in the mild steel part and very fine dimples in the stainless steel part.

  • PDF

Surface roughness changes caused by the galvanic corrosion between a titanium abutment and base metal alloy (티타늄 지대주와 비귀금속 합금사이의 갈바닉 부식에 의한 표면 거칠기 변화 평가)

  • Lee, Jung-Jin;Song, Kwang-Yeob;Ahn, Seung-Keun;Park, Ju-Mi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.65-72
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate the level of electro-chemical corrosion and surface roughness change for the cases of Ti abutment connected to restoration made of base metal alloys. Materials and methods: It was hypothesized that Ni-Cr alloys in different compositions possess different corrosion resistances, and thus the specimens ($13{\times}13{\times}1.5\;mm$) in this study were fabricated with 3 different types of metal alloys, commonly used for metal ceramic restorations. The electrochemical characteristics were evaluated with potentiostat (Parstat 2273A) and the level of surface roughness change was observed with surface roughness tester. Paired t-test was used to compare mean average surface roughness (Ra) changes of each specimen group. Results: All specimens made of nickel-chromium based alloys, average surface roughness was increased significantly (P < .05). Among them, the Ni-Cr-Be alloy ($0.016{\pm}.007\;{\mu}m$) had the largest change of roughness followed by Ni-Cr ($0.012{\pm}.003\;{\mu}m$) and Ni-Cr-Ti ($0.012{\pm}.002\;{\mu}m$) alloy. There was no significant changes in surface roughness between each metal alloys after corrosion. Conclusion: In the case of galvanic couples of Ti in contact with all specimens made of nickel-chromium based alloys, average surface roughness was increased.

Evaluation of effect of galvanic corrosion between nickel-chromium metal and titanium on ion release and cell toxicity

  • Lee, Jung-Jin;Song, Kwang-Yeob;Ahn, Seung-Geun;Choi, Jung-Yun;Seo, Jae-Min;Park, Ju-Mi
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.172-177
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate cell toxicity due to ion release caused by galvanic corrosion as a result of contact between base metal and titanium. MATERIALS AND METHODS. It was hypothesized that Nickel (Ni)-Chromium (Cr) alloys with different compositions possess different corrosion resistances when contacted with titanium abutment, and therefore in this study, specimens ($10{\times}10{\times}1.5mm$) were fabricated using commercial pure titanium and 3 different types of Ni-Cr alloys (T3, Tilite, Bella bond plus) commonly used for metal ceramic restorations. The specimens were divided into 6 groups according to the composition of Ni-Cr alloy and contact with titanium. The experimental groups were in direct contact with titanium and the control groups were not. After the samples were immersed in the culture medium - Dulbecco's modified Eagle's medium[DMEM] for 48 hours, the released metal ions were detected using inductively coupled plasma mass spectrometer (ICP-MS) and analyzed by the Kruskal-Wallis and Mann-Whitney test (P<.05). Mouse L-929 fibroblast cells were used for cell toxicity evaluation. The cell toxicity of specimens was measured by the 3-{4,5-dimethylthiazol-2yl}-2,5-diphenyltetrazolium bromide (MTT) test. Results of MTT assay were statistically analyzed by the two-way ANOVA test (P<.05). Post-hoc multiple comparisons were conducted using Tukey's tests. RESULTS. The amount of metal ions released by galvanic corrosion due to contact between the base metal alloy and titanium was increased in all of the specimens. In the cytotoxicity test, the two-way ANOVA showed a significant effect of the alloy type and galvanic corrosion for cytotoxicity (P<.001). The relative cell growth rate (RGR) was decreased further on the groups in contact with titanium (P<.05). CONCLUSION. The release of metal ions was increased by galvanic corrosion due to contact between base metal and titanium, and it can cause adverse effects on the tissue around the implant by inducing cytotoxicity.