• Title/Summary/Keyword: Nickel-chromium

Search Result 212, Processing Time 0.03 seconds

Chromium and nickel concentrations in air and in serum of workers in chromium and nickel electroplating plants (도금업 근로자의 혈청과 공기중 크롬 및 니켈 농도)

  • Choi, Ho Chun;Kim, Hae Jeong;Chung, Ho Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.117-127
    • /
    • 1991
  • The exposure level of chromium and nickel for chrome and nickel plating workers were evaluated. Chromium and nickel concentrations in serum from 82 exposed workers and 66 controls, who were not exposed occupationally to metals, were analyzed by flameless atomic absorption spectrophotometry. The results were as follows : 1. The recovery percent of chromium and nickel concentrations in personal air samples were 95-108.2%, 88.0-107.7%, precisions (C.V., %) were 2.7-3.1%, 2.1-4.4%. respectively. 2. The recovery percent of chromium and nickel concentrations in serum were 93.6-106.4%, 91.3-107.9% and precisions (C.V. %) were 1.1-7.6%, 2.4-5.4% respectively. 3. The exposure level of chromium and nickel concentrations in the place of preparation process were $2.0{\pm}2.00{\mu}g/m^3$, chromplating were $35.7{\pm}53.07{\mu}g/m^3$, $2.8{\pm}3.42{\mu}g/m^3$, nickelplating were $4.6.0{\pm}5.8{\mu}g/m^3$, $18.62{\pm}4.41{\mu}g/m^3$, and covering were $2.9{\pm}2.02{\mu}g/m^3$, $1.1{\pm}0.47{\mu}g/m^3$ respectively. There were significant difference of concentrations for chromium and nickel in workplaces by groups statistically. 4. Chromium concentrations in serum of exposed group and control were $0.68{\pm}0.399{\mu}g/l$, $1.41{\pm}0.748{\mu}g/l$, respectively. There were significant difference of concentrations for chromium and nickel in serum by groups statistically. 5. Chromium and nickel concentrations in serum of exposed group were not significant by workplaces.

  • PDF

Chromium and Nickel Concentrations in Urine and Serum of None Exposed Group and Workers in Electroplating Plants (정상인과 도금업 근로자의 요 및 혈청중 크롬 및 니켈 농도)

  • Choi, Ho-Chun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.1-7
    • /
    • 1995
  • The exposure levels of chromium and nickel for chromeplating workers were evaluated. Chromium and nickel concentrations in urine and serum from 82 exposed workers and 69 controls, who were not exposed occupationally to metals, were analyzed by flameless atomic absorption spectrophotometry. The results were as follows: 1. Chromium concentrations in urine of exposed group and control were $3.49{\pm}1.83g/g$ of creatinine, $5.59{\pm}2.83g/g$ of creatinine, and in serum were $0.69{\pm}0.30g/l$, $2.31{\pm}1.16g/l$ respectively. There were significant difference of concentrations for chromium in urine and serum by group respectively. 2. Nickel concentrations in urine of exposed group and control were $0.92{\pm}0.23g/g$ of creatinine, $2.20{\pm}1.93g/g$ of creatinine, and serum concentrations were $0.52{\pm}0.34g/l$, $1.41{\pm}0.74g/l$ respectively. There were significant difference of concentrations for nickel in serum by groups statistically. 3. Chromium and nickel concentrations in urine and serum of exposed groups were not significant by workplaces(grinding, electroplants, packaging).

  • PDF

METAL RELEASE FROM BRACKETS AND ARCHWIRES (BRACKET과 호선의 금속유리)

  • Park, Soo Byung;Rhee, Byung Tae
    • The korean journal of orthodontics
    • /
    • v.19 no.2
    • /
    • pp.75-84
    • /
    • 1989
  • The purpose of this experiment was to measure the amounts of nickel and chromium released from a simulated orthodontic appliance in artificial saliva. Simulated mandibular half-arch orthodontic appliances were composed of American Iron and Steel Institute type 304 brackets, Permachrome, Elgiloy, Australian wire, T.M.A. and Nitinol. The amounts of nickel and chromium released from sample were measured with atomic absorption spectrophotometer after 3, 6, 9, 12, 15 days. The cumulative amounts of nickel released from Permachrome, Elgiloy, Australian wire and T.M.A. reached a plateau after 6 days. But the cumulative amounts of nickel released from Nitinol increased continuously. Significant amounts of both nickel and chromium were solubilized from the simulated orthodontic appliances into artificial saliva. After 15 days, total cumulative amounts of nickel were $152.15{\mu}g$, $150.27{\mu}g$, $134.74{\mu}g$, $114.67{\mu}g$ and $93.39{\mu}$ from the Elgiloy, Australian wire, Nitinol, Permachrome and T.M.A., respectively. Total cumulative amounts of chromium from Permachrome, Australian wire, Elgiloy, Nitinol and T.M.A. were $100.83{\mu}g$, $83.64{\mu}g$, $81.61{\mu}g$, $14.90{\mu}g$ and $12.43{\mu}g$, respectively. The result showed that nickel released from Elgiloy and chromium released from Permachrome were more than any others.

  • PDF

A study on the release of nickel and chromium from simulated orthodontic appliances (교정장치로부터의 니켈과 크롬의 유리에 관한 연구)

  • Ryu, Jeong-Hyun;Oh, Soh-Taek;Kang, Kyung-Wha;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.33 no.5 s.100
    • /
    • pp.351-358
    • /
    • 2003
  • Nickel and chromium are two major metals used in the alloys of most orthodontic appliances. But these metals are known to cause hypersensitivity, dermatitis, and asthma. In addition, a significant carcinogenic and mutagenic potential has been demonstrated for compounds containing these metals. The purpose of this study was to find out how much nickel and chromium was released from orthodontic appliances, and which factors would influence the release. The simulated orthodontic appliances were constructed for a half of a mandibular arch and incubated in $0.05\%$ NaCl solution at $37^{\circ}C$. Nickel and chromium release was quantified with an Inductively Coupled Plasma (ICP) spectroanalyzer. The results were as follows : 1. From simulated orthodontic appliances, nickel was released $9.83-70.0{\mu}g/day$ but the release of chromium was not detectable in Limit of 10ppb. 2. The amount of nickel release was significantly different between the types of appliances. 3. The galvanic condition increased the amount of nickel release, which was not statistically significant. 4. The sand blasting increased the amount of nickel release, which was also not statistically significant.

Studies on the Chemical Plating of Nickel and Chromium on Steel (화학도금법에 의한 강의 니켈 및 크롬도금)

  • Kim, Man;Kim, Dai-Ryong;Yoon, Byung-Ha
    • Journal of Surface Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.127-137
    • /
    • 1982
  • In chemical plating of nickel and chromium on steel, studies on various factors affect-ing the plating operations were carried out. The optimum bath compositions and operat-ing conditions were obtained. The structure and properties of the as deposits or deposits after heat treatment were investigated. (1) The most optimum conditions for the chemical nickel and chromium plating were; 〔Ni2+〕/〔H2PO2-〕; 0.5∼0.8, 〔Cr3+〕/〔H2PO2-〕; 0.6∼0.9 PH;5.0∼5.5, temperature; 90∼95$^{\circ}C$ (2) In the case of nickel deposition, the hardness of deposits increased with increasing phosphorous contents. Heat-treating at the temperature range 200$^{\circ}C$ to 600$^{\circ}C$, the maximum hardness of deposits was obtained at 400$^{\circ}C$ and decreased at temperature above 400$^{\circ}C$ due to growth of Ni3P. (3) Corrosion resistance of chemical nickel deposits was improved with increasing of p-hosphorous contents and heat treating temperature.

  • PDF

Evaluation on the Efficiencies of Local Exhaust Systems and Airborne Concentrations of Total Chromium, Hexa-valent Chromium and Nickel in Some Electroplating Plants (일부 영세 도금사업장의 국소배기성능과 공기중 총크롬, 6가 크롬 및 니켈농도와의 관계분석)

  • Park, D.U.;Park, D.Y.;Shin, Y.C.;Oh, S.M.;Chung, K.C.
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.68-77
    • /
    • 1993
  • To evaluate efficiencies of the local exhaust systems installed in chromiun and nickel eletroplating tanks, specifications of each tank and general performances of the local exhaust systems were measured in 16 electroplating plants from July 3 to November 24, 1992. Airborne concentrations of total chromium, hexa-chromium and nickel were also measured, Most of the local exhaust systems installed in electroplating plants were inadequately designed. Average capture velocities of local exhaust systems in chromium and nickel tanks were 0.45 m/sec and 0.29 m/sec. Average slot velocities in chromium and nickel tanks were 7.30 m/sec and 2.87 m/sec repectively. Both average capture and solt velocities were in noncompliance with the standards recommened by American Conference of Governmental Industrial Hygienists (ACGIH) and National Institute for Occupational Safety and Health (NIOSH), Exhausted air volume was insufficient in all local exhaust systems surveyed. Worker exposure levels to total chromium, hexa-chromium and nickel were $43.0{\mu}g/m^3$, $1.7{\mu}g/m^3$ and $9.3{\mu}g/m^3$, which were below the Korean Standard and U.S. Occupational Health and Safety Administration (OHSA) Permissible Exposure Limit(REL). However, Worker exposure level to hexa-chromium exceeded the NIOSH Recommended Exposure Limit(REL) of $1{\mu}g/m^3$. As the result of Scheffee's multiple comparions, worker exposure levels to all metals were significantly different between two groups by the management state of existing local exhaust systems (p<0.05). However, Difference between a group with local exhaust systems which were poorly managed and another group without local exhaust system was satatistically non-significant.

  • PDF

Evaluation of Carcinogenic Metals in Particulate Using New ISO Standard Method (국제표준규격에 의한 입자상 물질 중 발암성 금속의 평가)

  • Park, Ji Young;Yoon, Chung Sik;Ha, Kwon Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.2
    • /
    • pp.99-107
    • /
    • 2008
  • We quantified the human carcinogenic metals (chromium, nickel) in fumes from flux cored arc welding using stainless steel (FCAW/SS) wires. Zinc and calcium were also quantified because of their possibility of zinc chromate and calcium chromate, respectively. Welding was performed in an American Welding Society standard fume collection chamber. Insoluble and soluble forms of metals were analyzed by ISO 15202 method. Total chromium (insoluble+soluble) content and total nickel content were lower in FCAW/SS fumes (4.65%, 1.05%, respectively)than in stainless steel content (ca. 18%, 8%,respectively). Insoluble fraction in total chromium was 79.8 (range 64.5~95.1)% and 94.4(range 90.1~98.1)% in total nickel. Atomic emission spectroscopy used in this study does not differentiate the chromium valence status while ACGIH defines its carcinogenicity according to the valence status. From this study and previous study, we estimated the hexavalent chromium content in FCAW/SS was 0.2~1.1% and about 85% of them was soluble. The content of zinc and calcium, which can be existed as chromate forms, was low (0.02 %, 0.04% respectively) in FCAW/SS. Exposure assessment for zinc chromate and calcium chromate is possible because chromium in both compounds is used as a surrogate even though it is not well known that what compounds of zinc and calcium are formed in welding fume.

EFFECT OF TWO OPAQUING TECHNIQUES ON METAL-CERAMIC BOND STRENGTH (Opaque 도재의 도포 방법이 치과용 합금과 도재간의 결합 강도에 미치는 영향)

  • Jang, Il-Seong;Lee, Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.3
    • /
    • pp.475-488
    • /
    • 1996
  • The opaque porcelain layer of porcelain-fused-to-metal(PFM) restoration is critical for the success of PFM restoration because it is the first layer placed over the treated alloy. But, the methods of opaquing technique have not been confirmed. Usually, the one layer method and two layer method have been used for the application of opaque porcelain. In the past, alloys with porcelain veneers which have been used successfully have contained various precious metals. Recent increase in the cost of precious metals stimulates considerable interest in nonprecious alloys. Although nickel-chromium alloys and nickel-chromium-beryllium alloys have been widely used, the use of cobalt-chromium alloys would be gradually increased with elimination of any potential risk of nickel-related allergic responses and/or beryllium-related toxic responses. This investigation examined one- and two-layer opaque porcelain applications to determine the effect on the bond strength of titanium added cobalt-chromium metal ceramic alloy. Bond strength of Ceramco II porcelain to titanium added cobalt-chromium alloy(2Dentitan) and gold-platinum-palladium alloy(Degudent H) were evaluated by direct shear bond strength test with Instron universal testing machine. The results were as follows; 1. When the mean shear bond strength of each experimental group were compared in $0.25cm^2$ unit area, the titanium added cobalt-chromium alloy/two layer method exhibited the greatest strength(79.7kg), followed by titanium added cobalt-chromium alloy/one layer method(76.2kg), gold-platinum-palladium alloy/two layer method(71.4kg), gold-platinum-palladium alloy/one layer method(64.2kg). 2. No significant differences in bond strength were recorded between the two opaquing techniques for gold-platinum-palladium alloy and titanium added cobalt-chromium alloy. 3. No significant differences in bond strength were recorded between the gold-platinum-palladium alloy and the titanium added cobalt-chromium alloy.

  • PDF

Atomic Absorption Spectrophotometric Analysis of Chromium, Nickel and Manganese in Stainless Steel (原子吸光分析에 의한 鋼鐵속에 있는 Cr, Mn 및 Ni 의 定量)

  • Hwang, Jae-Young;Tagliamonti, Josep J.;Parsons, Frank B.
    • Journal of the Korean Chemical Society
    • /
    • v.10 no.3
    • /
    • pp.133-135
    • /
    • 1966
  • Rapid methods for determining chromium, nickel, and manganese in stainless steel by atomic absorption spectrophotometer are described. Use of suitable standards eliminates the need to separate each element prior to analysis. Comparison with the conventional wet chemical analysis shows that atomic absorption spectrophotometer is a reliable analytical tool in these applications.

  • PDF