• Title/Summary/Keyword: NiMo

Search Result 651, Processing Time 0.032 seconds

Comparison of Liver, Kidney, Bone Metal Concentration in OhJeokSan-Treated Rats (오적산(五積散)을 투여한 흰쥐의 간장, 신장, 골중 금속농도 비교에 관한 연구)

  • Park Chul-Soo;Lee Sun-Dong;Park Hae-Mo;Park Yeong-Chul
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.6 no.2
    • /
    • pp.66-85
    • /
    • 2002
  • Traditional herbal medicine is used extensively among the Korean populations, and other Asian countries employ similar therapies as well In recent years, extensive focus was laid on adulteration of the herbal medicine with heavy metals. This may be mainly due to a soil contamination by an environmental pollution. The objective of this study is to identify the contents of various heavy metals in the blood from OhJeokSan-Decoction (OD) treated-rats. For this study, 13 kinds of metals including essential and heavy metals, i.e. Al, As, Cd, Co, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Se and Zn were analyzed by a slight modification of EPA methods and the following results are obtained. ; 1. There is no significant difference between the OD-treated groups and control group in liver, kidney, bone, brain, weight, food intake. 2. The amount of each metal analyzed in the liver are as follows; Al ; $0.235{\sim}4.215mg/kg$, As ; $0.103{\sim}0.461mg/kg$, Cd ; $0.005{\sim}0.010mg/kg$, Co ; $0.017{\sim}0.046mg/kg$, Cr ; $0.137{\sim}0.403mg/kg$, Cu ; $1.736{\sim}4.827mg/kg$, Fe ; $54.472{\sim}381.447mg/kg$, Hg ; not detected, Mn ; $1.159{\sim}2.803mg/kg$, Ni ; $0.007{\sim}0.095mg/kg$, Pb ; not detected, Se ; $0.682{\sim}1.887mg/kg$, Zn ; $10.213{\sim}26.119mg/kg$, by groups, respectively. In control and other experimental group, several metal (Co, Cu, Mn, Zn, As, Cr) has a significant difference, but in experimental I and other experimental II, III, IV, V groups, there are no significant difference. 3. The amount of each metal analyzed in the kidney are as follows; Al ; $1.712{\sim}31.230mg/kg$, As ; $0.062{\sim}0.439mg/kg$, Cd ; $0.010{\sim}0.062mg/kg$, Co ; $0.000{\sim}0.101mg/kg$, Cr ; $0.125{\sim}0.636mg/kg$, Cu ; $3.385{\sim}12.502mg/kg$, Fe ; $41.148{\sim}99.709mg/kg$, Hg ; $0.000{\sim}0.270mg/kg$, Mn ; $0.433{\sim}2.301mg/kg$, Ni ; $0.000{\sim}0.221mg/kg$, Pb ; $0.000{\sim}0.584mg/kg$, Se ; $0.540{\sim}1.600mg/kg$, Zn ; $8.775{\sim}17.060mg/kg$, by groups, respectively. The concentration of Cu, Se, Cr, and Hg are variated significantly in control and other experimental group, and Cu, Se, Cd, Cr are variated significantly in experimental I and other experimental II, III, IV, V groups. 4. The amount of each metal analyzed in the bone(tibia and fibula) are as follows; Al ; $9.557{\sim}119.464mg/kg$, As ; $0.139{\sim}12.250mg/kg$, Cd ; $0.000{\sim}0.295mg/kg$, Co ; $0.022{\sim}0.243mg/kg$, Cr ; $0.239{\sim}1.999mg/kg$, Cu ; $0.000{\sim}2.291mg/kg$, Fe ; $240.249{\sim}841.956mg/kg$, Hg ; $0.000{\sim}0.983mg/kg$, Mn ; $0.214{\sim}7.353mg/kg$, Ni ; $5.473{\sim}11.453mg/kg$, Pb ; $0.000{\sim}8.502mg/kg$, Se ; $0.000{\sim}3.005mg/kg$, Zn ; $61.158{\sim}195.038mg/kg$, by groups, respectively. The concentration of Se, Cd are variated significantly in control and other experimental groups, and Se is variated significantly in experimental I and other experimental II, III, IV, V groups. 5. Exceptionally several metal concentration is increased or decreased. but there is no significant harmful difference of metal concentration in the liver, kidney and bone, from the OD-treated-rats compared to those of the control group even if higher dosage($1{\sim}8$ times dosage of person) of OD was administered. Thus, it is expected that the herbal decoction in the traditional herbal medicine would not lay any burden on the body and the heavy metal toxins would not affect our physiological system. However, other kinds of herbal treatment, such as i.v. and i.p. should be considered in terms of metal toxicity in the body since the level of certain metal.

  • PDF

Occurrence Characteristics of Bophi Vum Chromite Mineralized Zone in the Northwestern Myanmar (미얀마 북서부 보피붐 크롬철석 광화대의 산출특성)

  • Heo, Chul-Ho;Chi, Se-Jung;Kang, Il-Mo;Jin, Kwang-Min
    • Economic and Environmental Geology
    • /
    • v.47 no.4
    • /
    • pp.351-362
    • /
    • 2014
  • In order to grasp the geological characteristics, the occurrence mode of ore body and development potential of Bophi Vum chromite mineralized zone in northwestern Myanmar, Korea Institute of Geoscience and Mineral Resources(KIGAM) and Department of Geological Survey and Mineral Exploration(DGSE) carried out joint exploration targeting on the $6km^2$ areas within the mineralized zone. Chromitites occur as a major Cr-ore body in the Bophi Vum area, and are enveloped by dunitic peridotites. As a result of geological survey, the geological map of Bophi Vum was drawn in the scale of 1:1,000, and we discovered that the chromitite ores are mainly distributed at the elevation range between 200 and 400 m. The soil geochemistry was conducted by collecting total 114 soil samples in the interval of 50 m after pitting ground surface under 0.7-1 m. Geochemical anomaly maps of Cr, Ni, Fe, and Mn were prepared by ICP-AES.

Bioassessment of Heavy Metals, Nanoparticles, and Soils Contaminated with Metals using Various Bioassays (다양한 독성법을 이용한 중금속, 나노입자 및 금속오염 토양 평가)

  • Kong, In Chul;Shi, Yu Tal;Lee, Min Kyung;Kang, Il Mo
    • Economic and Environmental Geology
    • /
    • v.48 no.3
    • /
    • pp.261-271
    • /
    • 2015
  • Toxicity results of metals, nanoparticles (NPs), and soils contaminated with metals were introduced on this review. Following methods were used: seed germination, bioluminescence, enzyme activity, and mutation. In general, different sensitivities were observed, depending on types of bioassays and pollutants. Among tested seeds, sensitivities of Lactucus and Raphanus were greater than others. Of single metal exposure, effect by As(III) was greater than others, and high revertant mutation ratio (5.1) was observed at 1 mg/L arsenite, indicating high mutagenicity. No general pattern was observed on the effect of metal mixture, but synergistic effect was observed with seeds. In case of soils, no correlation was observed between total metal contents and toxicity. Toxicity of NPs was observed as follows: CuO > ZnO > NiO > $TiO_2$, $Fe_2O_3$, $Co_3O_4$. Especially, no considerable effects were observed by $TiO_2$, $Fe_2O_3$, and $Co_3O_4$ under tested concentration (max. 1,000 mg/L). The evaluation results of interactive toxic effects using various bioassays may comprise a useful tool for the bioassessment of various environmental pollutants.

Characteristics of hazardous oil & liquid fuel waste discharged from various industries (폐유 및 액상연료 공정 폐기물에서 무기물질류의 함량특성)

  • Shin, Sun-Kyoung;Jeong, Seong-Kyeong;Kim, Woo-Il;Jeon, Tae-Wan;Kang, Young-Yeul;Yeon, Jin-Mo;Cho, Yoon-A;Kim, Min-Sun
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.276-286
    • /
    • 2013
  • This study was performed to investigate the contents characteristics of hazardous oil wastes and wastes of liquid fuels from different industrial process. In order to establish a hazardous waste list, samples of various industrial discharge have been analyzed for 16 non-regulated inorganic hazardous substances (i.e., Cu, Pb, Cd, CN, Hg, As, T-Cr, $Cr^{6+}$, Sb, Ni, F, V, Ba, Zn, Be, Se). In more detail, hazardous waste samples including waste hydraulic oils, waste engine, gear and lubricating oils, waste insulating and heat transmission oils, bilge oils, oil/water separator contents processing were collected from 37 workplaces and analyzed. We observed that the most of the inorganic substances exceeded the proposed criteria in many samples. Especially the concentration of Sb in heat transmission oil, bilge oil and gear & lubricating oils were ranged from 6 to 419 mg/kg whereas the proposed criteria is 50 mg/kg. The assessment result of hazardous waste in Korea according to the EWC showed that the out of 24 processes, 16 belongs to absolute entry and 8 belongs to mirror entry. In conclusion, we expect the outcome of this study to align the classification system of hazardous waste management in South Korea with international legislations, and consequently contribute to reduce environmental pollution as well as health risks by toxic wastes.

FLEXURE STRENGTH OF CAST-JOINED CONNECTOR WITH Ni-Cr-Be ALLOY (주조연결된 니켈-크롬-베릴리움 주조체의 굽힘강도에 관한 비교연구)

  • Jeong, Chang-Mo;Jeon, Young-Chan;Lim, Jang-Seop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.858-866
    • /
    • 1998
  • Soldering is the usual method used to correct an unstable fixed partial denture framework at patient's try-in; However, presoldering base metal alloys is technique-sensitve and results are unstable because it is difficult to maintain uniform heat distribution and to prevent oxidation of an alloy. A cast-joining technique has been developed by Weiss and Munyon for repair, correction and addition to base metal framework. This joining technique eliminates the problem with presoldering of non-precious frameworks. The object of this study was to 1) compare the relative flexure strength and the joining effectiveness of Ni-Cr-Be cast in two pieces and 'pre-soldered' versus in two pieces and 'cast-joined'. 2) determine the effect of increasing the number of retentive grooves on the face of the cast and 3) determine the effect of the relative matched position of groove patterns on flexure strength. The joining effectiveness can be expressed by the ratio of the mean flexure stress of soldered or cast-joined specimens to that of one-piece cast. Resin rods 3mm in diameter were used as pattern of specimens for one-piece casted, presoldered, and cast-joined groups. Cast-joined specimens had two different patterns of retentive grooves on the joined faces. Type A had cross-shaped grooves 1mm in depth. 0.6mm in width. Type B was the same except for the addition of one more retentive groove. In the experiment connecting cast-joined specimens, half of specimens with type A pattern had their patterns on the faces of paired casts matched with each other as mirror image. With the rest pairs, it was proceeded that one of paired casts turned 45 degrees so that the patterns crossed. Half of specimens with type B pattern also had the patterns matched as mirror image; However, here, one of paired casts turned 90 degrees with the other pairs. Retentive groove in this study lacked the intentional undercuts, in contrast with the suggestion of Weiss and Munyon. The specimens were subjected to four-point flexural loading in an Instron testing machine. The midspan flexural stress was calculated at the point of initial plastic strain as determined from a strip-chart recorder or at the point of failure if this occured at a lower stress level. Within the scope of this study, the following results were obtained. 1. The presoldered group showed flexural strength at least 2 times higher than the cast-joined groups. Its joining effectiveness was 82%. 2. In cast-joined groups, the flexural strength of joints with type B patterns exhibited 1.5 times that of joints with type A patterns. Joining effectivenesses were 38% for type B patterns, 25-26% for type A patterns. 3. The relative matched position of groove patterns did not have any significant effect on flexural strength of the cast-joined specimens with either type A patterns or type B patterns(p>.05).

  • PDF

Studies on the Processing of Rapid Fermented Anchovy Prepared with Low Salt Contents by Adapted Microorganism 1. Biochemical Characterization of Proteolytic Bacteria and their Extracellular Pretense Isolated from Fermented Fish Paste (미생물을 이용한 저식염 멸치젓의 속성발효에 관한 연구 1. 젓갈에서 분리한 단백질분해균 및 단백질분해효소의 생화학적 특성)

  • CHA Yong-Jun;LEE Eung-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.22 no.5
    • /
    • pp.363-369
    • /
    • 1989
  • In this study, the biochemical characterization of strong proteolytic bacteria and their extracellular pretense isolated from fermented fish paste were experimented for the purpose of industrial large scale-production by accelerated fermentation. The results obtained were as follows: Among 4 strains isolated from fermented fish paste, B. subtilis p-4 and B. licheniformis p-5, which grow well at $40^{\circ}C$, pH 7.0 and $1\%$ of salt contents, were the best proteolytic bacteria and were shown $0.48hr^{-1}$, $0.49hr^{-1}$ of specific growth rate in TPY medium, respectively. Maximum enzyme activity of B. subtilis p-4 was 335n mole-Tyr/min.ml after 30 hrs and that of B. licheniformis p-5 was 300n mole-Tyr/min.ml after 28 hrs of shaking culture. Purified pretense produced by B. subtilis p-4 and B. licheniformis p-5 showed maximum activity at $50^{\circ}C$, pH 7.0 and molecular weight were estimated to be 18,000, 30,000 by sephadex G-100 gel filtration, respectively. These were supposed to be a kind of metal chelator sensitive neutral pretense from the result of high sensitivity against EDTA, o-phe-nanthroline and metal ions such as $Cu^{2+},\;Ni^{2+},\;Zn{2+}$.

  • PDF

Application of Gamma Ray Densitometry in Powder Metallurgy

  • Schileper, Georg
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2002.07a
    • /
    • pp.25-37
    • /
    • 2002
  • The most important industrial application of gamma radiation in characterizing green compacts is the determination of the density. Examples are given where this method is applied in manufacturing technical components in powder metallurgy. The requirements imposed by modern quality management systems and operation by the workforce in industrial production are described. The accuracy of measurement achieved with this method is demonstrated and a comparison is given with other test methods to measure the density. The advantages and limitations of gamma ray densitometry are outlined. The gamma ray densitometer measures the attenuation of gamma radiation penetrating the test parts (Fig. 1). As the capability of compacts to absorb this type of radiation depends on their density, the attenuation of gamma radiation can serve as a measure of the density. The volume of the part being tested is defined by the size of the aperture screeniing out the radiation. It is a channel with the cross section of the aperture whose length is the height of the test part. The intensity of the radiation identified by the detector is the quantity used to determine the material density. Gamma ray densitometry can equally be performed on green compacts as well as on sintered components. Neither special preparation of test parts nor skilled personnel is required to perform the measurement; neither liquids nor other harmful substances are involved. When parts are exhibiting local density variations, which is normally the case in powder compaction, sectional densities can be determined in different parts of the sample without cutting it into pieces. The test is non-destructive, i.e. the parts can still be used after the measurement and do not have to be scrapped. The measurement is controlled by a special PC based software. All results are available for further processing by in-house quality documentation and supervision of measurements. Tool setting for multi-level components can be much improved by using this test method. When a densitometer is installed on the press shop floor, it can be operated by the tool setter himself. Then he can return to the press and immediately implement the corrections. Transfer of sample parts to the lab for density testing can be eliminated and results for the correction of tool settings are more readily available. This helps to reduce the time required for tool setting and clearly improves the productivity of powder presses. The range of materials where this method can be successfully applied covers almost the entire periodic system of the elements. It reaches from the light elements such as graphite via light metals (AI, Mg, Li, Ti) and their alloys, ceramics ($AI_20_3$, SiC, Si_3N_4, $Zr0_2$, ...), magnetic materials (hard and soft ferrites, AlNiCo, Nd-Fe-B, ...), metals including iron and alloy steels, Cu, Ni and Co based alloys to refractory and heavy metals (W, Mo, ...) as well as hardmetals. The gamma radiation required for the measurement is generated by radioactive sources which are produced by nuclear technology. These nuclear materials are safely encapsulated in stainless steel capsules so that no radioactive material can escape from the protective shielding container. The gamma ray densitometer is subject to the strict regulations for the use of radioactive materials. The radiation shield is so effective that there is no elevation of the natural radiation level outside the instrument. Personal dosimetry by the operating personnel is not required. Even in case of malfunction, loss of power and incorrect operation, the escape of gamma radiation from the instrument is positively prevented.

  • PDF

MICROLEAKAGE OF RESILON BY METHACRYLATE-BASED SEALER AND SELF-ADHESIVE RESIN CEMENT (Resilon을 이용한 근관충전 시 레진계열의 근관실러와 자가-접착 레진시멘트에 따른 미세누출)

  • Ham, Sun-Young;Kim, Jin-Woo;Shin, Hye-Jin;Cho, Kyung-Mo;Park, Se-Hee
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.204-212
    • /
    • 2008
  • The purpose of this study was to compare the apical microleakage in root canal filled with Resilon by methacrylate-based root canal sealer or 2 different self-adhesive resin cements. Seventy single-rooted extracted human teeth were sectioned at the CEJ perpendicular to the long axis of the roots with diamond disk. Canal preparation was performed with crown-down technique using Profile NiTi rotary instruments and GG drill. Each canal was prepared to ISO size 40, .04 taper and 1 mm short from the apex. The prepared roots were randomly divided into 4 experimental groups of 15 roots each and 5 roots each for positive and negative control group. The root canals were filled by lateral condensation as follows. Group 1: Gutta-percha with AH-26, Group 2: Resilon with RealSeal primer & sealer, Group 3: Resilon with Rely-X Unicem, Group 4: Resilon with BisCem. After stored in $37^{\circ}C$, 100% humidity chamber for 7 days, the roots were coated with 2 layers of nail varnish except apical 3 mm. The roots were then immersed in 1% methylene blue dye for 7 days. Apical microleakage was measured by a maximum length of linear dye penetration after roots were separated longitudinally. One way ANOVA and Scheffe's post-hoc test were performed for statistical analysis. Group 1 showed the least apical leakage and there was no statistical significance between Group 2, 3, 4. According to the results, the self adhesive resin cement is possible to use as sealer instead of primer & sealant when root canal filled by Resilon.

  • PDF

Hydrogenolysis of CFC-113a$(CF_3CCl_3)$ Catalyzed by Heterogeneous Catalysts in the Liquid Phase (불균일 촉매를 이용한 CFC-113a$(CF_3CCl_3)$의 액상 가수소 분해 반응)

  • Jo, Uk Jae;Lee, Ik Mo;Kim, Hong Gon;Kim, Hun Sik
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.9
    • /
    • pp.695-700
    • /
    • 1994
  • Hydrogenolysis reactions of CFC-113a catalyzed by various heterogeneous catalysts $(Rh/Al_2O_3,\;Pd/C,\;Ni,\;Al_2O_3,\;Active\;carbon)$ were investigated in the liquid and gas phases. In the liquid phase reaction, different catalysts showed different activities, but all catalysts used gave high selectivities toward HCFC-123 over 95%. It was noticeable that the neutral $Al_2O_3$ showed both a high activity and a selectivity in the liquid phase reaction. In the gas phase reaction, transition metals on carbon(Pd/C, Pt/C) were so active for hydrogenolysis of CFC-113a that they even catalyzed the production reaction of overhydrogenated compounds such as $HCFC-133a(CF_3CH_2Cl)\;and\;HFC-143a(CF_3CH_3)$. $Al_2O_3$, which showed the high activity in the liquid phase reaction, did not show a remarkable activity. When $Al_2O_3$ was used in the liquid phase reaction, the hydrogenolysis of CFC-113a proceeded without any side products in THF. However, the same reaction in MeOH produced side products, such as $CH_3OCH_3\;and\;CH_3CH_2OCH_3$ from solvent. Based on this result, including heterogeneous catalysts, it was concluded that the solvent played an important role in the liquid phase reaction.

  • PDF

MICROLEAKAGE OF RESILON BY METHACRYLATE-BASED SEALER AND SELF-ADHESIVE RESIN CEMENT (Resilon을 이용한 근관충전 시 레진계열의 근관실러와 자가-접착 레진시멘트에 따른 미세누출)

  • Ham, Sun-Young;Kim, Jin-Woo;Shin, Hye-Jin;Cho, Kyung-Mo;Park, Se-Hee
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.204-212
    • /
    • 2008
  • The purpose of this study was to compare the apical microleakage in root canal filled with Resilon by methacrylate-based root canal sealer or 2 different self-adhesive resin cements. Seventy single-rooted extracted human teeth were sectioned at the CEJ perpendicular to the long axis of the roots with diamond disk. Canal preparation was performed with crown-down technique using Profile NiTi rotary instruments and GG drill. Each canal was prepared to ISO size 40, .04 taper and 1 mm short from the apex. The prepared roots were randomly divided into 4 experimental groups of 15 roots each and 5 roots each for positive and negative control group. The root canals were filled by lateral condensation as follows. Group 1: Guttapercha with AH-26, Group 2: Resilon with RealSeal primer & sealer, Group 3: Resilon with Rely-X Unicem, Group 4: Resilon with BisCem. After stored in $37{\circ}C$, 100% humidity chamber for 7 days, the roots were coated with 2 layers of nail varnish except apical 3 mm. The roots were then immersed in 1% methylene blue dye for 7 days. Apical microleakage was measured by a maximum length of linear dye penetration after roots were separated longitudinally. One way ANOVA and Scheffe's post-hoc test were performed for statistical analysis. Group 1 showed the least apical leakage and there was no statistical significance between Group 2, 3, 4. According to the results, the self adhesive resin cement is possible to use as sealer instead of primer & sealant when root canal filled by Resilon.