• 제목/요약/키워드: Ni-based alloy

검색결과 313건 처리시간 0.024초

Ni-Cr합금과 도재간의 결합력에 gold-based bonding agent가 미치는 영향 (The effect of the gold based bonding agents on the bond between Ni-Cr alloys and ceramic restorations)

  • 이정환;주규지
    • 대한치과기공학회지
    • /
    • 제29권2호
    • /
    • pp.213-223
    • /
    • 2007
  • The success of a porcelain fused to metal (PFM) restoration depends upon the quality of the porcelain-metal bond. The adhesion between metal substructure and dental porcelain is related to the diffusion of oxygen to the reaction layer formed on cast-metal surface during firing. The purposed of this investigation was to study the effects of gold based bonding agent on Ni-Cr alloy-ceramic adhesion between porcelain matrix, gold based bonding agent and metal substructure interface. gold based bonding agent have been applied as an intermediate layer between a metal substructure and a ceramic coating. gold based bonding agent(Aurofilm NP, Metalor, Swiss) was applied on Ni-Cr alloy surface by four method. Surfaces only air abraded with 110${\beta}\neq$ Al2O3 particles were used as control. metal ceramic adhesion was evaluated by a biaxial flexure test(N=5) and volume fraction of adherent porcelain was determined by SEM/EDS analysis. Result of this study suggest that the layering sequence of gold based bonding agent is very important and can improve porcelain adherence to PFM.

  • PDF

니켈-크롬 합금 보철물 주위 치은 열구내에서 발견된 니켈 내성 균주에 관한 분자생물학적 연구 (A STUDY OF NI-RESISTANT BACTERIA ISOLATED FROM GINGIVAL CREVICULAR FLUID ON THE PATIENTS WEARING NI-CR ALLOY PROSTHESIS (IN TERMS OF MOLECULAR BIOLOGICAL ASPECTS))

  • 채영아;우이형;이성복
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.207-222
    • /
    • 2003
  • As a material of metal-ceramic prosthesis, nickel as a form of Ni-Cr alloy has been used for many dental prostheses in many cases. However, several problems in use of the alloy have been revealed (ex ; tissue stimulation, skin allergy, hypersensitivity cytotoxicity and carcinogenecity). Little is known about nickel with respect to the relationship between Ni-prosthesis and gaining of Niresistance in oral microorganisms. The present study was undertaken to check whether use of Ni-prosthesis leads to occurrence of Ni-resistant microorganisms. So this study may suggest the possible relationships between the oral microorganisms and nickel-resistance in oral environment. Bacteria were isolated from the gingival crevicular fluid on the patients wearing Ni-Cr prosthesis. The isolated bacteria were tested fir their Ni-resistance in nickel containing media at different concentration from 3mM to 110mM. E. coli HB101 was used as control. The Ni-resistant bacteria were isolated and biochemically identified. The Ni-resistant bacteria were tested several biochemical, molecular-biological tests. Performed tests were : measuring the growth curve, antibiotic test, growth ability test in liquid media, isolation of the chromosome and plasmid, digestion of DNA by restriction enzyme, electrophoresis of chromosome and plasmid DNA, identification of Ni-resistant genes by the DNA hybridization. The results were as follows 1) The bacteria isolated from gingival crevicular fluid on the patients wearing Ni-Cr alloy prosthesis showed nickel-resistance. 2) The isolated microorganisms grew at nickel containing media of high concentrations (60mM-110mM). 3) Based on the biochemical tests, the isolated microorganisms were identified as Enterococcus faecalis(13 cases), Klebsiella pneumoniae(1 case) and Enterobacter gergoviae(1 case). 4) Enterococcus faecalis expressed not only nickel resistance but also the multi-drug resistance to several antibiotics ; chloramphenicol, kanamicin, streptomycin, lincomycin, clindamycin, However, all strain showed the sensitivity against the tetracycline. 5) DNA hybridization result suggests that there is no homology between the previously known gene of nickel resistance in Klebsiella pneumoniae and chromosomal DNA of Enterococcus faecalis.

신조성의 Ti-기반 합금 수소분리막의 설계 및 수소투과 성능 (Fabrication and Hydrogen Separation Performance of Newly Created Ti-Based Alloy Membrane)

  • 고민영;신민창;장학룡;황재연;한성우;김시은;박정훈
    • 멤브레인
    • /
    • 제34권2호
    • /
    • pp.146-153
    • /
    • 2024
  • 본 실험에서는 Ti를 기반으로 한 평판 수소 분리막을 설계하여 제조하였다. 새로운 조성의 Ti를 베이스로 한 수소 분리막을 찾기 위하여 여러 합금들의 물리화학적 특성과 수소투과도 사이의 상관관계에 대해 조사하였다. 이를 바탕으로 신조성의 합금막 2종(Ti14.2Zr66.4Ni12.6Cu6.8 (70 ㎛), Ti17.3Zr62.7Ni20 (80 ㎛))을 설계 및 제조하였다. 제조된 평판 수소 분리막은 300~500℃, 1~4 bar의 조건에서 혼합 가스(H2, N2), sweep 가스(Ar)를 이용하여 수소 투과 실험을 진행하였다. Ti14.2Zr66.4Ni12.6Cu6.8 합금막은 500℃, 4bar에서 최대 16.35 mL/cm2 min의 flux를 가지며, Ti17.3Zr62.7Ni20 합금막은 450℃, 4 bar에서 최대 10.28 mL/cm2 min의 flux를 가진다.

HVOF 용사법에 의해 제조된 WC계 합금 코팅층의 방식특성(II) - 알칼리 용액에서의 분극특성 - (Anti-Corrosion Characteristics of WC-based Alloy Coatings Fabricated by HVOF Process - Polarization Characteristics in Alkaline Solution -)

  • 김태용;김영식;김재동
    • 동력기계공학회지
    • /
    • 제18권6호
    • /
    • pp.40-44
    • /
    • 2014
  • The purpose of this paper is to investigate polarization characteristics of WC-based alloy coatings in alkaline solution. The coatings were fabricated with WC-CrC-Ni, WC-Co-Cr and WC-Co composite powders by HVOF process. Corrosion tests of coatings and substrate were carried out using potentiostat/galvanostat at solution with pH 8 and pH 13. Corrosion potential(Ecorr) and corrosion current density(Icorr) could be studied from polarization curve, and corrosion behavior was analyzed by SEM and EDS. WC-Co-Cr coating and WC-CrC-Ni coating showed more favorable anti-corrosion characteristics than WC-Co coating and substrate at solution with pH 8 and pH 13.

HVOF 용사법에 의해 제조된 WC계 합금 코팅층의 방식특성(I) - 산성용액에서의 분극특성 - (Anti-Corrosion Characteristics of WC-based Alloy Coatings Fabricated by HVOF Process - Polarization Characteristics in Acid Solution -)

  • 김태용;김영식
    • 동력기계공학회지
    • /
    • 제18권4호
    • /
    • pp.72-77
    • /
    • 2014
  • The aim of this study to investigate polarization characteristics of WC-based alloy coatings fabricated by high velocity oxygen fuel(HVOF) process. The coatings were fabricated by HVOF process with WC-CrC-Ni, WC-Co-Cr, WC-Co composite powders. Corrosion tests were carried out using potentiostat/galvanostat at solution with pH 2 and pH 6. Corrosion potential(Ecorr) and corrosion current density(Icorr) could be analyzed from polarization curve. WC-Co-Cr coating showed more incorrodible characteristics than other coatings at solution pH 2. WC-CrC-Ni coating was more favorable anti-corrosion characteristics than other coatings at solution with pH 6.

Cu계 비정질 입자의 가압 성형 (Consolidation of Cu-based amorphous particles)

  • 강은영;정영훈;유호근;박종우
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 추계학술대회 논문집
    • /
    • pp.273-276
    • /
    • 2005
  • Packing characteristics of amorphous alloy particles were investigated by scanning electron microscopy, compositional analysis, micro-hardness test and finite element method (FEM). Electroless Ni-plating was made on the surface of the Cu-based amorphous particles before consolidation in ambient atmosphere at an intermediate region of glass transition and crystallization temperatures $(T_g\;and\;T_x)$. Some parts of the Ni-layer in the interfaces of the consolidated particles disappeared, while some of them still remained without appreciable change in compositions. No cracks or fractures were found in the particles, which may occur at low temperatures below or near $T_g$ as anticipated by the FEM analysis. Crystallization and change in hardness were not observed after consolidation.

  • PDF

초탄성 거동을 고려한 NiTi 합금 튜브의 변형해석 (Finite Element Analysis of NiTi Alloy Tubes with the Superelastic Behavior)

  • 강우종
    • 한국자동차공학회논문집
    • /
    • 제14권5호
    • /
    • pp.100-106
    • /
    • 2006
  • NiTi alloy known as its shape memory effect also has superelastic characteristic, which makes it possible to be elastic under large deformation. Since the tensile strength of the alloy is very high and density is low compared to carbon steel, it can be applied to lightweight structural design. In order to design structures with shape memory alloy, finite element analysis is used and a constitutive algorithm based on Aurrichio's model is added to LS-DYNA as a user subroutine. Explicit time integration and shell element formulation are used to simulate thin-walled structures. The algorithm uses Drucker-Prager type loading condition to calculate martensite volume fraction during the transformation. The implemented algorithm is verified in uni-axial loading condition and martensite phase transformation can be detected well with the algorithm. In this study, as a energy absorbing structure, thin-walled tube is modeled with finite elements and the deformation behavior is studied. Simulation results has shown that the martensite transformation was generated in loading condition. After plastic deformation reached, the load decreases linearly without reverse martensite transformation.

In-situ Raman Spectroscopic Study of Nickel-base Alloys in Nuclear Power Plants and Its Implications to SCC

  • Kim, Ji Hyun;Bahn, Chi Bum;Hwang, Il Soon
    • Corrosion Science and Technology
    • /
    • 제3권5호
    • /
    • pp.198-208
    • /
    • 2004
  • Although there has been no general agreement on the mechanism of primary water stress corrosion cracking (PWSCC) as one of major degradation modes of Ni-base alloys in pressurized water reactors (PWR's), common postulation derived from previous studies is that the damage to the alloy substrate can be related to mass transport characteristics and/or repair properties of overlaid oxide film. Recently, it was shown that the oxide film structure and PWSCC initiation time as well as crack growth rate were systematically varied as a function of dissolved hydrogen concentration in high temperature water, supporting the postulation. In order to understand how the oxide film composition can vary with water chemistry, this study was conducted to characterize oxide films on Alloy 600 by an in-situ Raman spectroscopy. Based on both experimental and thermodynamic prediction results, Ni/NiO thermodynamic equilibrium condition was defined as a function of electrochemical potential and temperature. The results agree well with Attanasio et al.'s data by contact electrical resistance measurements. The anomalously high PWSCC growth rate consistently observed in the vicinity of Ni/NiO equilibrium is then attributed to weak thermodynamic stability of NiO. Redox-induced phase transition between Ni metal and NiO may undermine the integrity of NiO and enhance presumably the percolation of oxidizing environment through the oxide film, especially along grain boundaries. The redox-induced grain boundary oxide degradation mechanism has been postulated and will be tested by using the in-situ Raman facility.

Ni 기지 초내열합금의 고온산화 저항성에 미치는 Ti의 영향 (Effects of Ti on High Temperature Oxidation of Ni-Based Superalloys)

  • 박시준;서성문;유영수;정희원;장희진
    • Corrosion Science and Technology
    • /
    • 제15권3호
    • /
    • pp.129-134
    • /
    • 2016
  • The effects of Ti on the high temperature oxidation of Ni-based superalloys were investigated by cyclic oxidation at $850^{\circ}C$ and $1000^{\circ}C$. The oxide scale formed at $850^{\circ}C$ consists of $Cr_2O_3$, $Al_2O_3$, and $NiCr_2O_4$ layers, while a continuous $Al_2O_3$ layer was formed at $1000^{\circ}C$. The oxidation rate of the alloy with higher Ti content was higher than the alloy with less Ti content at $850^{\circ}C$, possibly due to the increase in the metal vacancy concentration in the $Cr_2O_3$ layer involved by incorporation of $Ti^{4+}$. However, Ti improved the oxidation resistance of the superalloy at $1000^{\circ}C$ by reducing oxygen vacancy concentration in $Al_2O_3$ layer.

초임계 이산화탄소 발전용 소재의 고온 내식성 평가 (Evaluation of Corrosion Resistance of Materials for Supercritical Carbon Dioxide Power Plant)

  • 채호병;서석호;정용찬;이수열
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.109-113
    • /
    • 2015
  • 초임계 이산화탄소 발전 시스템 구축을 위해서는 고온, 고압의 열악한 환경에 노출되는 터빈, 열 교환기, 압축기와 같은 핵심 부품들의 내식성 평가는 반드시 수행되어야 한다. 이를 위해 후보소재 3종 Ferritic-Martensitic Steel (T92), Austenitic Steel (SS316L), Ni-based Alloy (IN738LC)를 선정하여 고온의 유사 초임계 $CO_2$ 발전 환경에서의 내식성 평가를 진행하였다. $600^{\circ}C$, $700^{\circ}C$의 2개의 온도 구간에서 $CO_2$ 분위기를 조성하여 800 시간 동안 노출시킨 뒤, Weight Change, Surface Morphology, Cross Section, Composition을 분석하였다. Cr-rich Protective Layer를 형성하는 Ni-based Alloy와 Fe/Cr-rich oxide를 형성하는 Austenitic Steel은 우수한 부식 저항성을 보인 반면에 Ferritic-Martensitic Steel은 높은 Weight Change와 Fe-rich Non-Protective Oxide가 관찰되어 상대적으로 낮은 부식 저항성을 보였다.