• Title/Summary/Keyword: Ni-Ti rotary file

검색결과 66건 처리시간 0.027초

Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals

  • Ha, Jung-Hong;Park, Sang-Shin
    • Restorative Dentistry and Endodontics
    • /
    • 제37권4호
    • /
    • pp.215-219
    • /
    • 2012
  • Objectives: The purpose of this study was to investigate the screw-in effect and torque generation depending on the size of glide path during root canal preparation. Materials and Methods: Forty Endo-Training Blocks (REF A 0177, Dentsply Maillefer) were used. They were divided into 4 groups. For groups 1, 2, 3, and 4, the glide path was established with ISO #13 Path File (Dentsply Maillefer), #15 NiTi K-file NITIFLEX (Dentsply Maillefer), modified #16 Path File (equivalent to #18), and #20 NiTi K-file NITIFLEX, respectively. The screw-in force and resultant torque were measured using a custom-made experimental apparatus while canals were instrumented with ProTaper S1 (Dentsply Maillefer) at a constant speed of 300 rpm with an automated pecking motion. A statistical analysis was performed using one-way analysis of variance and the Duncan post hoc comparison test. Results: Group 4 showed lowest screw-in effect ($2.796{\pm}0.134$) among the groups (p < 0.05). Torque was inversely proportional to the glide path of each group. In #20 glide path group, the screw-in effect and torque decreased at the last 1 mm from the apical terminus. However, in the other groups, the decrease of the screw-in effect and torque did not occur in the last 1 mm from the apical terminus. Conclusions: The establishment of a larger glide path before NiTi rotary instrumentation appears to be appropriate for safely shaping the canal. It is recommended to establish #20 glide path with NiTi file when using ProTaper NiTi rotary instruments system safely.

Influence of pre-existing surface defects on NiTi rotary instrument failure: A SEM study

  • Shin, Yu-Mi;Kim, Wu-Sung;Kum, Kee-Yeon
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.594-594
    • /
    • 2003
  • I. Objectives The purpose of this study is to determine if propagation of pre-existing manufacturing defects results in brittle fracture of NiTi rotary files by examining the fracture surface of the instrument by SEM, and to compare the fracture time of NiTi rotary files with different flute designs under cyclic loading. II. Materials and Methods This study examined three groups of rotary NiTi instruments (K3, ProFile, Hero). Of each group, 04 taper, size 30 and 06 taper, size 25 were selected.:120 in total. Surface defects were created by simulating the machining process of NiTi rotaries.(omitted)

  • PDF

만곡모형근관에서 초심자가 근관형성시 Ni-Ti 전동파일의 효용성 (The Efficiency of the Ni-Ti Rotary Files in Curved Simulated Canals Shaped by Novice Operators)

  • 박세희;조경모;김진우
    • Restorative Dentistry and Endodontics
    • /
    • 제28권2호
    • /
    • pp.146-155
    • /
    • 2003
  • 여러 가지 장점으로 인해 Ni-Ti 전동 파일을 근관성형에 사용하는 빈도가 점차 증가되는 추세이지만, 초심자를 대상으로 한 연구는 부족한 실정이다. 이에 본 연구에서는 초심자에서 Ni-Ti 전동 파일을 사용할 때 근관 형성의 효용성을 평가하고, 어떤 방법이 초심자에게 적절한지를 알아보고자 하였다. 근관형태가 재현된 레진 블록을 이용하여 12명의 초심자와 4명의 숙련자가 근관 형성을 시행하였다. 각 술자는 ProFile, ProTaper, Hybrid (ProFile+ProTaper)를 이용하여 각각의 레진 블록을 세 개씩 근관형성하고, 각 파일 별의 근관 형성 시간을 기록하였다. 근관 형성 전과 후의 digital 이미지를 중첩하여 치근단으로부터 1, 2, 3, 4, 5, 6, 7mm level에서 근관단면의 총길이 변화량, 만곡 외측의 길이 변화량, 만곡 내측의 길이 변화량, 중심이동량, 중심이동율과 치근단에서의 apical transportation을 구하고, 초심자와 숙련자 사이의 차이를 비교 평가하였다. 실험결과 ProFile군의 1, 3, 5, 6, 7mm level과 ProTaper군의 6mm level, Hybrid군의 3mm level에서 초심자의 근관단면의 총길이 변화량이 숙련자보다 많았다. 모든 군에서 치근단으로부터 4, 5, 6, 7mm level에서는 근관 중심이 만곡내측으로 이동하였고, 1 2, 3mm level 에서는 만곡외측으로 이동하였으나, 숙련자가 시행한 Hybrid군의 3mm level과 비숙련자가 시행한 ProTaper 군의 3mm level에서는 만곡내측으로 이동하였다. 모든 군의 3mm level과 ProFile 군의 5mm level에서 초심자의 중심이동율이 숙련자에 비해 컸으며, 초심자가 ProTaper를 사용시 더 큰 apical trans portation을 보였고, 모든 군에서 초심자가 근관형성시 더 많은 시간이 걸렸다. ProFile과 ProTaper를 이용한 Hybrid technique이 초심자에게 추천되며, 초심자들도 충분히 교육받는다면 만곡된 근관의 근관형성에 있어서 Ni-Ti rotary file의 이용이 가능하리라고 사료된다.

임상가를 위한 특집 2 - 엔진구동형 니켈-티타늄 파일의 디자인에 관한 고찰 (A review regarding on design of engine-driven nickel-titanium file)

  • 황호길
    • 대한치과의사협회지
    • /
    • 제51권10호
    • /
    • pp.551-555
    • /
    • 2013
  • The purpose of this study was to give a guideline for selecting the nickel-titanium (NiTi) file by review from many studies. Since the early 1990s, several instrument systems manufactured from NiTi have been introduced into endodontic practice. The specific design characteristics vary, such as tip shape and size, cross sectional view, helix angle, and pitch space. Some of the early systems have been removed from the market or play only minor roles; others are still widely used. New designs continually are produced, but the extent to which clinical outcomes will depend on design characteristics is difficult to forecast. In this study, I have reviewed the different design characteristics in respect of the safety and efficiency. With the review from many studies, I concluded that the clinicians must be understand the specific design characteristics for selecting the ideal NiTi rotary instruments.

Simulated resin root canal에서 엔진 구동형 Ni-Ti 파일로 근관성형 후 Buchanan plugger의 근관 내 삽입깊이에 대한 비교 연구 (A STUDY OF INSERTION DEPTH OF BUCHANAN PLUGGER AFTER SHAPING USING NI-TI ROTARY FILES IN SIMULATED RESIN ROOT CANALS)

  • 박연식;김동준;황윤찬;황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제31권2호
    • /
    • pp.125-132
    • /
    • 2006
  • 본 연구는 레진 블록에서 엔진구동형 Ni-Ti기구를 이용하여 근관성형 후 Buchanan plugger의 삽입 깊이에 대한 비교를 통해 임상적 상황에서 Ni-Ti 파일로 근관 성형 후 Continuous wave of condensation technique을 이용한 근관 충전시 적절한 크기의 Buchanan plugger 선택에 지침을 제공하기 위해 시행되었다. 만곡근관과 직선근관을 가진 레진 블록에서 ProTaper와 ProFile을 이용하여 근관 성형을 하였다. 성형 후 근관에 Buchanan plugger가 근관벽과 처음으로 접촉하는 부위까지 삽입한 후 그 상태에서 스캐너를 이용하여 이미지를 얻었다. 이미지 분석 프로그램을 이용해 근첨에서 plugger 첨부까지의 거리를 얻었다. 각 기구에 대한 plugger 삽입깊이에 대한 유의성을 검정하기 위해 one-way ANOVA를 시행하였고, 사후검정을 위해 Scheffe's test를 시행하였다. 본 연구의 결과 만곡되고 좁은 근관에서, ProTaper F2와 F3로 마무리 성형한 근관에서 F, FM크기의 plugger를 사용할 경우 Continuous wane of condensation technique으로 적절한 근관충전이 가능함을 시사하였다.

A comparison of dimensional standard of several nickel-titanium rotary files

  • Kim, Ki-Won;Cho, Kyung-Mo;Park, Se-Hee;Choi, Ki-Yeol;Karabucak, Bekir;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • 제39권1호
    • /
    • pp.7-11
    • /
    • 2014
  • Objectives: The aim of this study was to compare the dimensional standard of several nickel-titanium (Ni-Ti) rotary files and verify the size conformity. Materials and Methods: ProFile (Dentsply Maillefer), RaCe (FKG Dentaire), and TF file (SybronEndo) #25 with a 0.04 and 0.06 taper were investigated, with 10 in each group for a total of 60 files. Digital images of Ni-Ti files were captured under light microscope (SZX16, Olympus) at $32{\times}$. Taper and diameter at $D_1$ to $D_{16}$ of each files were calculated digitally with AnalySIS TS Materials (OLYMPUS Soft Imaging Solutions). Differences in taper, the diameter of each level ($D_1$ to $D_{16}$) at 1 mm interval from (ANSI/ADA) specification No. 101 were statistically analyzed using one-way ANOVA and Scheffe's post-hoc test at 95% confidence level. Results: TF was the only group not conform to the nominal taper in both tapers (p < 0.05). All groups except 0.06 taper ProFile showed significant difference from the nominal diameter (p < 0.05). Conclusions: Actual size of Ni-Ti file, especially TF, was different from the manufacturer's statements.

내부 응력이 .06 taper ProFile의 피로 파절에 미치는 영향 (Effect of internal stress on cyclic fatigue failure in .06 taper ProFile)

  • 정혜림;김진우;조경모;박세희
    • Restorative Dentistry and Endodontics
    • /
    • 제37권2호
    • /
    • pp.79-83
    • /
    • 2012
  • Objectives: The purpose of this study was to evaluate the relation between intentionally induced internal stress and cyclic fatigue failure of .06 taper ProFile. Materials and Methods: Length 25 mm, .06 taper ProFile (Dentsply Maillefer), and size 20, 25, 30, 35 and 40 were used in this study. To give the internal stress, the rotary NiTi files were put into the .02 taper, Endo-Training-Bloc (Dentsply Maillefer) until auto-stop by torque controlled motor. Rotary NiTi files were grouped by the number of induced internal stress and randomly distributed among one control group and three experimental groups (n = 10, Stress 0 [control], Stress 1, Stress 2 and Stress 3). For cyclic fatigue measurement, time for separation of the rotary NiTi files was recorded. The fractured surfaces were observed by field emission scanning electron microscope (FE-SEM, SU-70, Hitachi). The time for separation was statistically analyzed using two-way ANOVA and post-hoc Scheffe test at 95% level. Results: In .06 taper ProFile size 20, 25, 30, 35 and 40, there were statistically significant difference on time for separation between control group and the other groups (p < 0.05). Conclusion: In the limitation of this study, cyclic fatigue failure of .06 taper ProFile is influenced by internal stress accumulated in the files.

세가지 니켈 티타늄 파일의 휨과 비틀림 조건에서의 응력 분포에 관한 3차원 유한요소 연구 (STRESS DISTRIBUTION OF THREE NITI ROTARY FILES UNDER BENDING AND TORSIONAL CONDITIONS USING 3-DIMENSIONAL FINITE ELEMENT ANALYSIS)

  • 김태오;이찬주;김병민;박정길;허복;김현철
    • Restorative Dentistry and Endodontics
    • /
    • 제33권4호
    • /
    • pp.323-331
    • /
    • 2008
  • 이 연구의 목적은 세가지 니켈-티타늄 파일의 휨과 회전 조건 하에서의 응력 분포를 유한요소 모형을 이용하여 비교하는 것이다. ProFile .06/#30, ProTaper와 ProTaper Universal의 F3파일을 마이크로컴퓨터 단층촬영을 하고 reverse engineering을 통하여 세 니켈 티타늄 파일의 구조를 얻고 삼차원 유한요소모형을 제작하였다. 니켈 티타늄 합금의 비선형적인 물리적 성질을 반영하고 ABAQUS 프로그램을 이용하여 휨과 회전 조건 하에서의 기계적인 움직임을 수학적으로 예측 분석하였다. U-형태의 단면 구조를 가진 ProFile이 모형 가운데 가장 좋은 휨 성질을 나타냈다. 동일한 휨량 조건에서는 볼록한 삼각형 단면의 ProTaper가 다른 모형보다 많은 힘을 필요로 하였으며, 반면에 가장 높은 von Mises 응력은 ProTaper Universal의 단면에서 움푹 파인 부위에 집중되었다. ProFile 모형은 동일한 크기의 회전력 에 대해 가장 큰 응력 집중을 U-형 구 부위에 나타냈다. ProTaper 모형은 다른 모형에 비해 동일량을 비틀기 위해 더 많은 힘을 필요로 하였으며, 반면에, 동량의 비틀림에서는 가장 높은 von Mises 응력이 ProTaper Universal의 단면에서 움푹 파인 부위에 집중되었다.

Hand & rotary root canal instrument의 근관내 삭제 형태에 관한 전자현미경적 비교 (SEM EVALUATION OF THE PREPARED ROOT CANALS BY HAND AND Ni-Ti ROTARY ROOT CANAL INSTRUMENTS)

  • 오태석;박정원
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.477-486
    • /
    • 1998
  • Recently the development of rotary instrument makes it possible that in root canal treatment operator saves much more time, maintans original curved canal shape and easily prepares continuous tapered root canal. The purpose of this experiment was to examine the smoothness of the internal surface of prepared root canal and the effectiveness of debridement in prepared root canal by SEM for the comparison of hand and Ni-Ti rotary instrument. 25 extracted human teeth were access opened and # 10 K-type file was introduced into canal until it was appeared at the apical foramen. The working length was established by subtracting 0.5mm from this measurement. Group 1. The root canal preparation was done to # 30 with working length and then step-back until # 45 with K-Flexofile (Maillefer, Swiss). Group 2. Root canal preparation was done by Naviflex Ni-Ti file (Brasseler, USA) as the same technique with group 1. Group 3. Canal was prepared by Profile .04 (Maillefer, Swiss) taper until #30. Group 4. With use of Quantec (Tycom, USA) root canal was prepared from file number 1 to 8. In group 1 and 2, the root canal irrigant was NaOCl and the other groups, NaOCl and RC-prep (Premine Dental Products, USA) was used. The prepared teeth were notched with high-speed bur as bucco-lingual direction and fractured with chisel and mallet, then examined with SEM. Group 1 showed smooth internal surface. There were scratches mainly to the axial direction. Group 2 showed similar characteristics to those in group 1. Group 3 showed more smoother and linear cutting surface with bised scratches. Group 4 has the almost same characteristics group 3 and there was no difference in the file design. Ni-Ti rotary root canal instrument prepare the dentinal wall more smoother than hand instrument. The effectiveness of debridement was not fully affected by file design. The isthmus area and accessory canals of the root canal system were not prepared in any group. According to the result, hand and rotary type instrumentation techniques were effective in removal of major amount of tissue from root canal but it was not complete. In the direction of cutting movement there was difference between them.

  • PDF

레진모형근관에서 엔진구동형 및 수동형 ProTaper 파일로 근관성형 후 근관형태 변화에 대한 비교연구 (A COMPARATIVE STUDY OF THE CANAL CONFIGURATION AFTER SHAPING BY PROTAPER ROTARY AND HAND FILES IN RESIN SIMULATED CANALS)

  • 양인석;강인철;황윤찬;황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제30권5호
    • /
    • pp.393-401
    • /
    • 2005
  • 본 연구는 형태 및 재질이 동일한 엔진구동형 ProTaper파일과 수동형 ProTaper파일을 이용하여 레진모형근관을 성형한 후 근관형태 변화를 비교 분석하고자 시행되었다. 본 연구에서는 레진모형근관으로 총 40개의 J자와 S자의 근관 형태가 재현된 ENDO-TRAINING BLOC을 사용하였다. 근관 성형 기구로는 엔진구동형 Ni-Ti 파일로 $ProTaper^{TM}$, 수동형 Ni-Ti 파일로 $ProTaper^{(R)}$ For Hand Use를 사용하였다. 사용된 레진모형근관과 파일의 종류에 따라 10개씩 4개의 그룹으로 나누어 근관성형을 시행하였다. 근관 성형 전$\cdot$후 이미지를 스캐너 (Color scanner, UMAX Technologies, Inc., USA)를 이용하여 얻은 후. Photoshop 7.0 프로그램 (Adobe System Inc., USA)을 이용하여 이미지를 중첩하였다. 이미지 분석 프로그램 (Image-$Pro^{(R)}$ Plus, Media Cybernetic, USA)을 이용하여 치근단 쪽에서부터 0, 1, 2, 3, 4, 5, 6 및 7 mm 수준에서 근관 성형에 따른 근관의 내측 및 외측 폭경의 변화량, 근관 총폭경의 변화량, 근관 중심축의 변위량을 측정하였다. 또한 근관 성형 시간을 기록하였다. 두 기구 사이의 유의성 검정을 위해 독립 표본 t-검정을 시행하여, 근관 성형 시 수동형 ProTaper 파일이 엔진구동형 ProTaper 파일에 비해 근관 중심축의 변위가 유의하게 덜 일어나며 근관의 원래 형태를 더욱 잘 유지할 수 있지만, 근관 성형시간은 길어질 수 있다는 결론을 얻었다.