• Title/Summary/Keyword: Ni-Ti file

Search Result 106, Processing Time 0.021 seconds

Selection of Nickel-Titanium Files according to the Clinical Procedure and Factors of File Fracture: A Narrative Review

  • Hyeon-Cheol, Kim
    • Journal of Korean Dental Science
    • /
    • v.15 no.2
    • /
    • pp.112-120
    • /
    • 2022
  • In this article, the contemporary root canal treatment procedure using nickel-titanium (NiTi) instruments was reviewed to understand the correlations between the properties of files and safety of the clinical usage. Literatures were reviewed according to the process of clinical procedure of the root canal preparation, mainly for shaping during orifice flaring, glide-path preparation, and main canal instrumentation. Considering the reasons for NiTi file fracture, clinically implacable issues and ideas were discussed to reduce the fracture risk and increase clinical efficiency of the NiTi file systems. Various kinds of NiTi file systems have their own characteristics and properties given from their geometries and heat treatments and so on. Proper selection and careful usage of the NiTi file systems may reduce the risk of file fracture and increase the efficiency of NiTi file systems. Understanding of the clinical implications from the mechanical properties and characteristics of the engine driven NiTi instruments may decrease the risk of NiTi file fractures and increase the success rate in root canal treatment.

Shaping ability of Ni-Ti Rotary files in combination with GT Rotary Ni-Ti file (GT Rotary Ni-Ti file과 함께 사용한 구동용 Ni-Ti file의 근관 성형력 비교에 대한 연구)

  • Shin, Dong-Ryul;Park, Sang-Jin;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.196-206
    • /
    • 2002
  • 본 연구는 근관의 치관부는 GT Rotary file을 이용하여 성형하고, 근단부는 K-Flexofile, ProFile .04, Lightspeed, HERO642 file로 성형하여 근관용 file의 근관성형력을 비교하는 것이다. 실험 표본으로는 resin simulated root canal blocks(Dentsply, Swiss)를 이용하였고 4개의 군으로 분류하여 실험을 실시하였다. 모든 resin block을 GT Rotary file(Dentsply, Swiss)을 이용하여 치관부를 형성한 후 근단부는 K-Flexofile(Dentsply, Swiss), ProFile .04 taper file(Denstply. Swiss), Lightspeed file(Lightspeed Tech., USA), HERO642 file(Micromega, France)로 ISO size #35까지 형성하였다. 성형 후 preparation time과 instrument failure를 측정하였고 최종 사용한 file을 resin block 내에 재위치시켜 working length의 변화량을 0.5mm 단위로 측정하였다. Resin debris에 의한 canal blockage를 조사하였으며, 근관 내의 인상을 채득하여 canal form을 평가하였다. 성형 전과 성형 후의 사진을 촬영하고 computer software를 이용하여 중첩시킨 후 canal aberration, canal transportation을 평가하여 다음과 같은 결과를 얻었다. 1. Preparation time, working length의 변화량, canal blockage, canal aberration, canal transportation에 있어서 Ni-Ti file이 stainless steel file에 비하여 우수하였다(p<0.05). 반면에 근관성형력에 있어서 canal form과 canal transportation을 제외하고는 세 Ni-Ti file 사이에는 유의차가 없었다(p>0.05). 2. Canal form 중 taper에 있어서 Lightspeed는 적절하지 못한 taper를 보여주었다(p<0.05). 3. Canal transportation에 있어서 Lightspeed 군과 HER0642 군이 K-Flexofile 군과 ProFile .04 군에 비해 적게 나타났고(p<0.05), 특히 만곡의 끝 부분에서는 Lightspeed 군이 가장 적게 나타났다(p<0.05). 이상과 같은 연구결과로 보아 부적절한 taper를 지니고 있던 Lightspeed fie과 HERO642 file 중 HERO642 file은 GT Rotary file과 함께 사용함으로써 적절한 taper로 형성할 수 있었으나 Lightspeed file은 효과적이지 못하였으므로 적절한 taper를 형성하기 위한 file이 치근의 중간부를 형성하기 위해 필요함이 확인되었다.

Effects of ta-C Coatings on Surface Characteristics of Dental Ni-Ti Files (치과용 Ni-Ti파일의 표면특성에 미치는 ta-C코팅효과)

  • Sun-Kyun Park;Han-Cheol Choe
    • Corrosion Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.368-376
    • /
    • 2023
  • Dental Ni-Ti files must ensure stability and resistance to fatigue fracture. DLC and ta-C were coated to remove defects on the surface and ensure stability, and the surface characteristics were investigated. When coated with DLC, it was black, and in case of ta-C coating, it was blue-black. Scratches, which are defects caused by mechanical processing, were formed on the surface of the un-coated Ni-Ti file from the end of the file along the direction of processing, with the Pro-file appearing in the vertical direction and the K-file appearing in the file direction. Scratches were reduced on the coated surface, and the surface roughness was greatly reduced after coating compared to before coating. The un-coated Ni-Ti file had the lowest hardness, the DLC-coated file had the highest hardness, and ta-C showed relatively high hardness. The elastic modulus of the DLC coating film was high, and the ta-C elastic modulus was low. The adhesion of the DLC coating film tended to be higher than that of ta-C, and the wear loss amount of DLC coating of taC was lower. The corrosion potential of the ta-C coating increased significantly, and the corrosion current density decreased.

A STUDY ON COMPARISON OF STAINLESS STEEL, NICKEL-TITANIUM HAND, NICKEL-TITANIUM ENGINE-DRIVEN FILE INSTRUMENTATION USING COMPUTED TOMOGRAPHY (수동형 Stainless Steel, Nickel-Titanium 및 엔진 구동형 Nickel-Titanium File의 근관형성 능력에 관한 비교 연구)

  • Lee, Hwang;Im, Mi-Kyung;Lee, Keon-Il;Lee, Yong-Keun
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.391-400
    • /
    • 1998
  • The aim of this study was to determine the shaping ability of stainless-steel K file (S-S K file), nickel-titanium K file (Ni-Ti K file) and engine driven nickel-titanium file (Quantec file) in resin simulated root canal. Computed tomography was used to evaluate the change of the root canal morphology. Thirty nine resin simulated root canal were divided into four groups (A:12, B:12, C:12, D:3). Resin simulated canals were scanned by computed tomography before instrumentation (1st C-T scan). Canals were instrumented using step back preparation technique with S-S K file in group A and Ni-Ti K file in group B. Group C was prepared with engine driven Ni-Ti file. Group D was uninstrumented to compare the 1st C-T scan images with 2nd C-T scan images of root canal. Instrumented canals were again scanned using computed tomography (2nd C-T scan), and reformated images of the uninstrumented canals were compared with images of the instrumented canals. In the sections of 2mm and 6mm from the apex, Quantec file caused significantly less canal transportation than S-S K file and Ni-Ti K file (p<0.05). Quantec file produced more centered than S-S K file and Ni-Ti K file in the sections of 2mm and 4mm from the apex (p<0.05). There was no significant difference in the removed volume of canals among the each groups (p>0.05). However the removed canal volume from the apex to 5mm were significantly higher than them from 5mm to 1mm (p<0.05) in each groups. Under the conditions of this study, preparation with Quantec file was more effective and produce more appropriate canal shapes than S-S K file and Ni-Ti K file.

  • PDF

LIFETIME AND FRACTURE PATTERNS OF NITI ROTARY FILES IN MOLARS (대구치에서 회전식 NiTi file의 수명과 파절양상)

  • Kim, Jin-Woo;Ahn, Byung-Doo;Park, Se-Hee;Shin, Hye-Jin;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.3
    • /
    • pp.184-192
    • /
    • 2005
  • Intracanal separation of the rotary files is a serious concern in modern endodontic practice. The objective of this study was to compare the life span and fracture patterns of three NiTi rotary files in molar teeth Mesiobuccal roots of upper molar (n = 150) and mesial roots of lower molar (n = 150) were divided into three groups and each group was prepared with Profile, ProTaper, and K3 respectively. Every file was used until separation and/or deterioration of the cutting blade was happened, and then the number of canals to separation and/or unwinding were recorded. Radiographs and Scanning electon microscope (SEM) photographs were taken to evaluate the patterns of separation. The results were as follows: 1. There were no significant differences in numbers of canals to separation and/or unwinding among the groups. 2. Comparing between flaring files, K3 showed significant lower numbers of canals to separation and/or unwinding (p < 0.05), and there was no significant difference between shaping files 3. Separations of instruments were occurred at the midpoint of curvatures within the canals 4. In SEM observations, ductile fractures were seen in most of cases, characterized by shallow dimples. Additional researches is needed to provide a new guideline that informs the appropriate number of times to use NiTi files.

A STUDY ON THE ROOT CANAL MORPHOLOGY CHANGE BY NICKEL-TITANIUM AND STAINLESS STEEL FILE INSTRUMENTATION USING COMPUTERIZED TOMOGRAPHY (Nickel-Titanium file과 Stainless steel file을 이용한 근관형성시 컴퓨터 단층촬영사진상의 근관형태 변화에 관한 연구)

  • So, Mun-Seop;Im, Mi-Kyung;Lee, Keon-Il;Lee, Yong-Keun;Lee, Su-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.659-669
    • /
    • 1997
  • The goals of root canal instrumentation are complete debridement of pulp tissue, removal of microbes and affected dentin, and proper cleaning and shaping of the root canal space before obturation. Instrumentation with stainless steel files has been shown to produce undesirable results in canals, regardless of the improved technique or modified file type used. Nickel-Titanium(Ni-Ti) alloy has been shown to be exceptionally elastic, having a lower bending moment and lower permanent set after torsion, compared with similar gauge stainless steel. The purpose of this study was to evaluate the change of root canal prepared by Ni-Ti rotary and stainless steel instruments. Thirty-four single rooted teeth of similar shape and canal size were divided into three groups. The teeth were scanned by computed tomography before instrumentation. In group 1, canals were instrumented using a step-back technique with K-file. In group 2, canals were prepared with K-flex file using the same technique as group 1. Group 3 was prepared with nickel-titanium(Ni-Ti) rotary instrument using a manufacture's instruction. Instrumented teeth were again scanned using computed tomography, and reformated images of the uninstrumented canals were compared with images of the instrumented canals. K-flex file and Ni-Ti file caused significantly less canal transportation than K-file in the 8mm root canal section from the apex(p<0.05). K-flex file and Ni-Ti file produced more centered canal preparation than K-file in the 2mm section(p<0.05). Ni-Ti file maintained more precisely the center of the canal than K-flex file in the 10mm section (p<0.05). There was no difference in the removed volume of canals among each groups.

  • PDF

ROOT CANAL TREATMENT ON PRIMARY TEETH USING NICKEL-TITANIUM NOTARY FILES (회전식 nickel-titanium file을 이용한 유치의 근관치료)

  • Seo, Ju-Hee;Lee, Kwang-Hee;Kim, Dae-Eop;Yang, Kye-Sik
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.620-625
    • /
    • 2001
  • The pulpectomy or root canal treatment on primary teeth is to be done when there is evidence of chronic in flammation or necrosis in the radicular pulp. Due to the tortuous and ribbon-shaped anatomy of the primary teeth, the instrumentation of endodontic hand files and barbed broaches is not an easy procedure. Recently, many automatic Ni-Ti rotary instruments have been developed and has made endodontic treatment easier and faster. This report describes two cases of root canal treatment on primary molars using Ni-Ti rotary files. The cervical constricture was eliminated by the crown-down method, as smaller file proceeded unhindered into the apical third of the canal. In addition, the crown-down technique enhanced the efficacy of the endodontic irrigant. The use of rotary instrumentation for primary teeth seemed to be a more effective way to debride the uneven walls of primary teeth.

  • PDF

Comparison of screw-in effect of three NiTi file systems used by undergraduates (학생들이 사용한 세 종류 NiTi file systems의 screw-in effect 비교)

  • Oh, Seung-Hei;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.6
    • /
    • pp.477-484
    • /
    • 2006
  • The purposes of this study were to compare the apical terminus width of simulated curved root canal prepared with three NiTi file systems used by undergraduates for evaluation the effects of flute angle and pitch or radial land on reducing screw-in effect and to determine more safe NiTi file system for inexperienced operators. Fifty inexperienced undergraduate students prepared 150 simulated curved root canals in resin blocks with three NiTi file systems ; ProFile$^{(R)}$, Hero Shaper$^{(R)}$, K3$^{TM}$. The electric motor set at a speed of 300 rpm and torque of 30 in a 16 : 1 reduction handpiece was used. The simulated root canal was prepared to ISO #25 sizes with each file system. The scanned images of pre- and post-instrumented canal of resin block were superimposed. To evaluate the screw-in effect of three NiTi file systems, apical terminus width of root canal was measured from superimposed images and statistical analysis was performed. There were significant differences in three NiTi flle systems. ProFile$^{(R)}$ had significantly smaller width than Hero Shaper$^{(R)}$ and K3$^{TM}$"" (P < 0.05), but no significant difference was observed between K3$^{TM}$ and Hero Shaper$^{(R)}$. Under the condition of this study, active file system (Hero SHaper$^{(R)}$, K3$^{TM}$) with variable pitch and helical angle had more screw-in effect than passive file system (ProFile$^{(R)}$) with constant pitch and helical angle. It seems that the radial lands play more important role in reducing screw-in effect.

Relative efficacy of three Ni-Ti file systems used by undergraduates (학생들이 사용한 세 종류 Ni-Ti file systems의 근관성형 효율 비교)

  • Kim, Hyeon-Cheol;Park, Jeong-Kil;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.38-48
    • /
    • 2005
  • The purpose of this study was to compare and evaluate the shaping ability of the three different Ni-Ti file systems used by undergraduate students. Fifty undergraduate students prepared 150 simulated curved root canals in resin blocks with three Ni-Ti file systems - $ProFile^{(R)}$ (PF), Manual $ProTaper^{(R)}$ (MPT), Rotary $ProTaper^{(R)}$ (RPT). Every student prepared 3 simulated root canals with each system respectively. After root canal preparation, the Ni-Ti files were evaluated for distortion or breakage Assessments were made according to the presence of various types of canal aberrations. The pre- and post-instrumented canal images were attained and superimposed. The instrumented root canal width were measured and calculated for the net transportation (deviation) and the centering ratio. Under the condition of this study, both $ProTaper^{(R)}$ systems allowed significantly more removal of root canal wall than the $ProFile^{(R)}$ system. In the important other aspects such as the centering ratio, there was no significant differences between the systems. Novice dental students were able to prepare curved root canals with any kinds of Ni-Ti file systems with little aberration and great conservation of tooth structure. Students want to learn effective methods and at the same time simple rotary procedures. The rotary $ProTaper^{(R)}$ systems were one of the most compatible to these students from the point of view of cutting ability The $ProFile^{(R)}$ system was also compatible in safe and gentle shaping.

A STUDY ON THE STRESS OF FILES AND CANAL TRANSPORTATION IN A CURVED CANAL (만곡 근관 형성시 화일의 응력 및 근관 전이 양상에 관한 연구)

  • Park, Han-Soo;Yoon, Soo-Han
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.94-109
    • /
    • 1998
  • The purpose of this study was to evaluate the effect of materials and sizes of files on canal transportation in a curved canal. The stress and the strain energy of files of two kinds of materials (stainless steel and NiTi) and five sizes (No. 20, 25, 30, 35 and 40) in a curved canal were analyzed by a finite element program, NASTRAN. Curved canals in transparent resin blocks were instrumented with the 10 kinds of files, and the degree of canal transportation obtained by double exposure technique of photography was compared with the analysis by the finite element method. The results were as follows : 1. The stress of a file in a curved canal increased from the file body to the file tip. 2. The stress of a stainless steel file was about 2.5 times greater than that of a same-sized NiTi file. 3. The stress distributions of files of an identical material were the same, and the strain energies of files of an identical material increased as the size of files increased. 4. The strain energy of a No. 35 NiTi file was about the same as that of a No. 20 stainless steel file. 5. The degree of canal transportation by a stainless steel file was greater than that by a same-sized NiTi file. The degree of canal transportation generally increased as the size of a file increased. 6. The degree of canal transportation of a No. 35 NiTi file was about the same as that of a No. 20 stainless steel file.

  • PDF