• 제목/요약/키워드: Ni-Ti endodontic files

검색결과 24건 처리시간 0.028초

Cyclic fatigue test on different rotary NiTi files and handling methods

  • Kim, Jae-Kwan;Kim, Eui-Seong
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.599-599
    • /
    • 2003
  • Endodontic rotary NiTi(Nickel-Titanium) files have several advantages, but they also have some problems. Fracture of instrument is the one of the problems. Cyclic fatigue fracture may not give a previous sign(ex, bending or distortion of the files) before it happen. It is affected by various factors. This study investigated time which takes for cyclic fatigue fracture to happen and fracture patterns with regard to different NiTi files and pecking motion.(omitted)

  • PDF

회전식 nickel-titanium file을 이용한 유치의 근관치료 (ROOT CANAL TREATMENT ON PRIMARY TEETH USING NICKEL-TITANIUM NOTARY FILES)

  • 서주희;이광희;김대업;양계식
    • 대한소아치과학회지
    • /
    • 제28권4호
    • /
    • pp.620-625
    • /
    • 2001
  • 유치의 근관치료에서 치수절제술은 실활된 유치를 치열궁내에 유지하기 위해 치관과 근관부분의 괴사된 치수조직을 완전하게 제거하는 것을 말한다. 이 술식은 감염된 치수의 세균을감소시키는 것을 목적으로 하며, 다양하고 불규칙한 유치 근관의 형태가 주된 장애 요소로 작용한다. 더욱이 비협조적인 어린이의 경우에는 오랜 시간동안 정교한 시술을 하기가 곤란하다. 최근 들어 근관치료시에 회전식 기구를 이용하여 근관형성을 하는 장비들이 많이 개발되었으며 저속전기 모터에 회전식 NiTi file을 이용한 술식이 많이 사용되고 있다. 본 증례에서는 회전식 NiTi file과 전기모터를 이용하여 유구치의 근관치료를 시도하였다. 치수강을 개방하고 치관부 치수를 제거한 후 잠정적 작업장을 측정하였으며 적절한 NiTi file을 선택하여 잠정적 작업장까지 crown-down방법으로 점차적으로 형성하였다. 수용 file로 근단부 도달 및 성형을 하고 전체적인 마무리를 하여 Vitapex로 충전하여 양호한 결과를 얻었기에 보고하는 바이다.

  • PDF

차아염소산나트륨 처리와 멸균법이 근관 치료용 파일의 부식에 미치는 영향에 관한 연구 (THE EFFECT OF NAOCL TREATMENT AND STERILIZATION PROCEDURES ON THE CORROSION OF ENDODONTIC FILES)

  • 양원경;라윤식;이영규;손호현;김미리
    • Restorative Dentistry and Endodontics
    • /
    • 제30권2호
    • /
    • pp.121-127
    • /
    • 2005
  • 근관 치료시 많이 사용되고 있는 $K-flex^{(R)}$ S-S 파일 (Maillefer, USA)과 $Profile^{(R)}$ Ni-Ti 파일 (Maillefer, USA), $K-3^{(R)}$ Ni-Ti파일 (SybronEndo, USA)의 부식 정도를 보기 위하여 총 360개의 20번 file을 1) 멸균소독 방법 (고압가열멸균소독, E-O gas 소독) ,2) 근관세척 액 ($5,25\%$ 차아염소산나트륨, 생리식염수) ,3) 멸균소독 횟수 (1, 5, 10회 ) 에 따라 36개 실험군으로 나누었다. 각각의 파일을 각 군별로 처리한 뒤, 세 명의 검사자가 광학 현미경 하에서 25배의 배율로 검사하여 0; 부식 없음, 1; 경도의 부식, 2; 중등도의 부식, 3; 심한 부식으로 점수화 하였다. 심한 부식을 보이는 파일의 표면은 SEM으로 관찰하였고 Kruskal-Wallis test (p < 0.05)를 이용하여 통계 분석 처리하여 차아염소산나트륨 접촉 여부와 멸균소독 방법의 차이에 의한 부식 정도를 평가하였다. 그 결과 고압가열멸균소독을 10회 시행한 파일은 통계적으로 유의한 차이를 보여 부식 정도가 심하였고, 1회나 5회 고압가열멸균소독을 시행한 파일과 E-O 가스로 소독한 파일들은 부식의 정도가 경미하여 통계적으로 유의하지 않았다. 차아염소산나트륨 접촉 여부와 제조사 혹은 파일 재료에 따른 유의성 있는 차이는 없었다

근관치료 기구의 기계 형태적 특성과 이에 따른 임상적 영향 고찰 (Mechanical and geometric features of endodontic instruments and its clinical effect)

  • 김현철
    • Restorative Dentistry and Endodontics
    • /
    • 제36권1호
    • /
    • pp.1-11
    • /
    • 2011
  • 서론: 이 문헌의 목적은 Nickel-titanium (NiTi) 전동 파일의 기계적 형태적 양상과 이에 의한 임상적 연관성을 고찰하는 것이다. NiTi 전동 파일은 다양한 고유의 형태로 시장에 소개되었고 경쟁 상품에 비해서 근관 성형에 더 나은 능력을 가졌다고 주장하고 있다. 본론: 이 문헌에서는 NiTi 전동 파일의 형태(예. 팁, 테이퍼, helical angle 등)와 파일의 임상 적용 성과 사이의 가능한 상관관계를 다음과 같이 다룬다; - NiTi 전동 파일의 파절 양상 - 비활성 파일팁과 glide path - 파일 경사도와 임상 효과 - 파일 횡단면적과 임상 효과 - 열처리와 표면 특성 - Screw-in 효과와 치근 상아질의 유지 - Screw-in 효과를 줄이기 위한 고안 결론: 이상의 내용을 바탕으로, 임상가는 다양한 NiTi 전동 기구를 사용함에 있어 임상 상황에 적절한 장점을 고려하여 선택하고 사용할 수 있는 도움을 받을 수 있을 것이다.

Comparison of apical extrusion of intracanal bacteria by various glide-path establishing systems: an in vitro study

  • Dagna, Alberto;El Abed, Rashid;Hussain, Sameeha;Abu-Tahun, Ibrahim H;Visai, Livia;Bertoglio, Federico;Bosco, Floriana;Beltrami, Riccardo;Poggio, Claudio;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제42권4호
    • /
    • pp.316-323
    • /
    • 2017
  • Objectives: This study compared the amount of apically extruded bacteria during the glide-path preparation by using multi-file and single-file glide-path establishing nickel-titanium (NiTi) rotary systems. Materials and Methods: Sixty mandibular first molar teeth were used to prepare the test apparatus. They were decoronated, blocked into glass vials, sterilized in ethylene oxide gas, infected with a pure culture of Enterococcus faecalis, randomly assigned to 5 experimental groups, and then prepared using manual stainless-steel files (group KF) and glide-path establishing NiTi rotary files (group PF with PathFiles, group GF with G-Files, group PG with ProGlider, and group OG with One G). At the end of canal preparation, 0.01 mL NaCl solution was taken from the experimental vials. The suspension was plated on brain heart infusion agar and colonies of bacteria were counted, and the results were given as number of colony-forming units (CFU). Results: The manual instrumentation technique tested in group KF extruded the highest number of bacteria compared to the other 4 groups (p < 0.05). The 4 groups using rotary glide-path establishing instruments extruded similar amounts of bacteria. Conclusions: All glide-path establishment instrument systems tested caused a measurable apical extrusion of bacteria. The manual glide-path preparation showed the highest number of bacteria extruded compared to the other NiTi glide-path establishing instruments.

대구치에서 회전식 NiTi file의 수명과 파절양상 (LIFETIME AND FRACTURE PATTERNS OF NITI ROTARY FILES IN MOLARS)

  • 김진우;안병두;박세희;신혜진;조경모
    • Restorative Dentistry and Endodontics
    • /
    • 제30권3호
    • /
    • pp.184-192
    • /
    • 2005
  • 회전식 NiTi file은쉽게 파절되는 단점이 있으나 이에 대한 연구는 아직 부족하다. 본 연구에서는 회전식 NiTi file을 이용해 실제 치아에서 근관을 형성하고, 이 때 발생하는 파절 및 변형을 연구, 분석하였다. 상악 대구치의 근심협측 치근 (n = 150)과 하악 대구치의 근심치근 (n = 150)을 실험대상으로 하여 Profile, ProTaper 및 K3로 각각 근관형성 하였다. 각 file은 파절되거나 변형이 생길 때까지 계속하여 사용한 다음 그 사용횟수를 기록하였다. 파절의 양상을 관찰하기 위해 방사선 및 주사현미경 사진을 촬영하였다. 1 세 군간의 유의할만한 사용횟수의 차이는 없었다. 2. Flaring file 간의 비교에서는 K3의 사용횟수가 통계적으로 유의성 있게 적었으며 (p < 0.05), shaping file 간에는 유의할만한 차이가 없었다. 3, 회전식 NiTi file의 파절은 근관의 최대 만곡부에서 발생하였다. 4. 주사전자현미경으로 파절면을 관찰한 결과 연성파괴의 전형적인 양상인 얕은 딤플이 관찰되었다. 일반적으로 회전식 NiTi file의 평균 사용횟수는 제조회사의 사용지침보다는 길었으며, NiTi file의 수명에 대한 새로운 사용지침을 만들기 위한 부가적인 연구가 있어야 되리라 사료된다.

니켈티타늄 전동파일 파절의 예방 및 처치 (Prevention and Solution of the Fracture of Nickel-Titanium Endodontic Instruments)

  • 김현철
    • 대한치과의사협회지
    • /
    • 제54권8호
    • /
    • pp.640-650
    • /
    • 2016
  • Nickel-Titanium (NiTi) rotary instruments have brought a big step toward "efficient" practice of endodontic procedure. The rotary files help clinicians to reduce their working time and also increase the clinical success rate with minimal procedural errors. However, NiTi instruments still have a few drawbacks including unpredictable fatigue fracture. Clinicians may reduce the potential risk of instruments fracture by following some clinical guidelines for rotary instruments. In some clinical cases of instruments fracture, we may try to remove the instruments' fragments or bypass the fragment to reach the apical canal. In some limited cases, the fractured instruments' fragments would not jeopardize the clinical prognosis of root canal treatment. Nevertheless, it is impossible to be overemphasized that the prevention of file fracture is much easier than the removal of fracture fragment. Clinicians need to understand the fracture mechanisms and, in clinic, need to discard the used instruments timely.

  • PDF

NiTi Rotary Instrumentation이 근관만곡도 변화에 미치는 영향 (THE EFFECT OF NiTi ROTARY INSTRUMENTATION ON THE CHANGE OF APICAL ROOT CANAL CURVATURE)

  • 임형태;홍찬의;조용범
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.257-268
    • /
    • 1998
  • During cleaning and shaping of narrow and curved canals, it is very difficult or nearly impossible to maintain the original canal shape. Procedural accidents such as, ledge, zipping, perforation, and instrument breakage are frequently occurred and even may lead to failure of endodontic therapy. To prevent these kinds of accidents, various instrumentation techniques and materials have been introduced. Recently some nickel titanium (NiTi) files are introduced and it is reported that These NiTi files created rounder preparations with less transportation than conventional instruments in curved canals. This study compared the change of the canal curvature and procedural accidents after instrumentation produced by stainless steel K-flexo file, and NiTi rotary files (Profile 29 and Quantec 2000). Thirty narrow and curved canals (25-45 degree) of extracted human molars were randomly divided into three groups. In group 1, canals were instrumented using a step-back and watch-winding/pull motion with K-flexo files. In group 2, canals were prepared with Profile 29. Group 3, canals were prepared with Quantec 2000 files. Before and after preparation of canals, periapical radiographs were taken and scanned. The change of canal curvature were measured using Photoshop 4.0 program and the incidence of procedural accidents were also evaluated. The results were as follows: 1. All group showed some loss of canal curvature after instrumentation. 2. Average loss of canal curvature was $6.70{\pm}5.31$ degree for group 1, $3.80{\pm}2.57$ degree for group 2, and $5.40{\pm}4.83$ degree for group 3. All group There was significant change in curvature between before and after instrumentation (p<0.05). But there was no statistical difference amoung 3 groups. 3. In group I, there were no procedural accidents, such as ledging, perforation, or instrument fracture. In group 2, two cases of ledge and one case of instrument fracture were produced Goup 3, each one case of ledge, perforation and instrument fracture were occurred. Whthin the limits of above results, It seems that NiTi rotary instrumentation is not All Mighty and if we use uncarefully, it is more dangerous to produce some procedural accidents than conventional hand files. But more studies should be taken to evaluate the exact effects of NiTi rotary instrumentations.

  • PDF

Cyclic fatigue resistance of M-Pro and RaCe Ni-Ti rotary endodontic instruments in artificial curved canals: a comparative in vitro study

  • Feky, Hadeer Mostafa El;Ezzat, Khalid Mohammed;Bedier, Marwa Mahmoud Ali
    • Restorative Dentistry and Endodontics
    • /
    • 제44권4호
    • /
    • pp.44.1-44.11
    • /
    • 2019
  • Objectives: To compare the flexural cyclic fatigue resistance and the length of the fractured segments (FLs) of recently introduced M-Pro rotary files with that of RaCe rotary files in curved canals and to evaluate the fracture surface by scanning electron microscopy (SEM). Materials and Methods: Thirty-six endodontic files with the same tip size and taper (size 25, 0.06 taper) were used. The samples were classified into 2 groups (n = 18): the M-Pro group (M-Pro IMD) and the RaCe group (FKG). A custom-made simulated canal model was fabricated to evaluate the total number of cycles to failure and the FL. SEM was used to examine the fracture surfaces of the fragmented segments. The data were statistically analyzed and comparisons between the 2 groups for normally distributed numerical variables were carried out using the independent Student's t-test. A p value less than 0.05 was considered to indicate statistical significance. Results: The M-Pro group showed significantly higher resistance to flexural cyclic fatigue than the RaCe group (p < 0.05), but there was no significant difference in the FLs between the 2 groups (p ≥ 0.05). Conclusions: Thermal treatment of nickel-titanium instruments can improve the flexural cyclic fatigue resistance of rotary endodontic files, and the M-Pro rotary system seems to be a promising rotary endodontic file.

니켈티타늄 파일의 부식에 영향을 미치는 다양한 환경 조건 비교 (Comparative analysis of various corrosive environmental conditions for NiTi rotary files)

  • 염지완;박정길;허복;김현철
    • Restorative Dentistry and Endodontics
    • /
    • 제33권4호
    • /
    • pp.377-388
    • /
    • 2008
  • 이 연구에서는 다양한 부식 환경하에서 니켈티타늄 파일에 대한 부식 경향을 전기화학적 검사와 시각적 검사를 이용해 비교 평가하였다. 각 45개의 21 mm ProTaper Universal 52와 21 mm #25/0.06의 Hero642 file을 기계적 하중 여부, 저장 용액(증류수 및 차아염소산나트륨), 저장 온도(22$^{\circ}C$ 및 55$^{\circ}C$), 파일 종류에 따라 18개의 그룹(n = 5)으로 나누었다. 40개의 발거 치아 근관을 성형한 후 18시간 동안 저장 용액에 조건에 따라 보관하였다. 부식 산물의 생성 여부나 변색 등을 관찰하고 주사전자현미경을 이용해 각 시편을 다양한 배율에서 관찰하였으며 에너지 분산형 X선 분광기로 성분 분석을 하였다 전기화학적분극시험을 통하여 새 파일과 근관 성형에 사용한 파일의 부식저항성을 검사하였다. 본 실험 조건하에서는 저장 용액의 종류와 보관 온도가 니켈 티타늄 파일의 부식에 영향을 주는 것으로 나타났다. 또한 이종 금속이 존재하는 경우 갈바닉 부식의 영향으로 인해니켈 티타늄 파일의 부식 경향이 증가할 수도 있음을 보였다.