• Title/Summary/Keyword: Next door

Search Result 46, Processing Time 0.019 seconds

Strength of Pipe Type Door Impact Beam with Changed Bracket Mounting Method and TRP Application (브라켓 마운팅 방법 변경과 TRP 적용에 따른 강관형 도어 임팩트 빔 강도)

  • Kang, Sungjong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.4
    • /
    • pp.379-385
    • /
    • 2016
  • Door impact beam plays a key role in minimizing the occupant injury within the side impacted vehicle through preventing intrusion of the impacting vehicle. Steel pipe type door impact beam has been widely adopted since it has simple structure and the overall strength is easily determined according to the pipe size. The brackets welded at pipe ends connect the door impact beam and the door panels by spot welds. In this study, first, the effect of pipe thickness, bracket thickness and door mounting stiffness was respectively analyzed. Next, application of the tailor rolled pipe was examined and several alterations of the bracket mounting method were considered. Application of tailor rolled pipes with superior bracket mounting method showed remarkable strength enhancement and weight reduction possibility in comparison with the current door impact beam.

Analysis on Ventilation Performance of Natural Ventilation Systems in Multi-Family Housing Using Blower Door Test (Blower Door Test를 이용한 공동주택 자연환기시스템의 환기성능 분석)

  • Kim, Min Seok;Auh, Jin Sun;Hong, Goopyo;Kim, Byungseon Sean
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.129-134
    • /
    • 2016
  • Today, natural ventilation systems are widely applied in multi-family housing. However, studies using the wind data trend line of the blower door test are insufficient. Purpose: Through this study, we will propose a computational method about ventilation performance of natural ventilation systems by conducting blower door test. Method: First, we sealed the gaps between the main systems including the natural ventilation system and conducted the blower door test. Next, the natural ventilation system was opened, the blower door test was conducted, and the difference in air flow rate between when closed and when opened was checked. Blower door test was carried out with a pressure difference of 50 Pa. Result: Therefore, the ventilation performance of the natural ventilation system was checked by drawing a trend line using the data to calculate the air flow rate at 2 Pa of the natural ventilation equipment standard pressure difference.

The Section Design of Press Door Impact Beam for Improving Bending Strength (굽힘 강도 향상을 위한 프레스 도어 임팩트 빔의 단면 설계)

  • Jo, Kyeongrae;Kang, Sungjong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.1
    • /
    • pp.74-81
    • /
    • 2017
  • The door impact beam of the side-impacted vehicle plays a key role in securing occupant safety by preventing intrusion from the impacting vehicle. Despite the low production cost, the press door impact beam has been adopted sparingly because of the strength inferiority. In this study, the design technologies of the press beam aimed at improving bending strength were investigated. First, the effect of the section shape and size was examined. Next, thickness and material strength were increased. Also, the TRB beam application was simulated by varying combined thickness. Some TRB beams with reduced weight exhibited bending strength over the strength of the pipe beam. Then, the beam with a closed center section also showed remarkably enhanced maximum bending strength.

System Design for Access to Subway Vent based Bluetooth Smart Door-Lock (지하철 환기구 출입관리를 위한 블루투스 스마트 도어락 시스템)

  • Kim, Tae-Yong;Lee, Dae-Suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.63-65
    • /
    • 2016
  • In this paper, smart door-lock system to access public facilities will be proposed. An existed door-lock system using physical door-lock, NFC Tag, and RFID could be replaced by our proposed system. Automatic access control management system with security authentication module enables the worker to access public facilities efficiently.

  • PDF

The Relation of Bending Buckling Strength in Vehicle and Three Point Bending Maximum Strength of Door Impact Beam (도어 임팩트 빔의 3점 굽힘 최대강도와 차량 장착 시 굽힘 좌굴강도와의 관계)

  • Kang, Sungjong;Lee, Sangmin
    • Journal of Auto-vehicle Safety Association
    • /
    • v.11 no.1
    • /
    • pp.40-47
    • /
    • 2019
  • First, three point bending analysis for the inclined press door impact beam was carried out to investigate inclination angle effect on the maximum strength with varying support distance. Next, for the system model with spring elements representing body stiffness at door mounting area, the bending structural behavior of impact beam mounted on vehicle was estimated. The mounting distance and inclination angle were changed and the beam bending buckling strength was presumed at the head displacement below which spring stiffness change has little effect on the load. Finally strength ratio to predict the bending buckling strength of impact beam mounted on vehicle from three point bending maximum strength of fixed support distance was suggested.

A Study on History of Rolling Stock Door Engines of Seoul Metro Line No.3 and No.4 (3,4호선 도시철도 전동차 도어엔진의 개발 역사에 관한연구)

  • Jang, Sung-Chul;Lee, Chan-Hee;Jeon, Kwan-Soo;Son, Young-Jin
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1352-1359
    • /
    • 2010
  • It is said that the number of people using public transportation has risen about 220 thousand over 3 years which was 1019 people average a day in 2006 and 1041 people last year. It is also said that the number of people using subway has increased by 198 thousand and the number of people using bus by 22 thousand. Can you imagine how many door engines work at the same time if we count Metro line no.1 to no.4 which consist of total 120 subway stations? A train has 80 door engines and Metro line trains have 9600 door engines all together. Which explains it quite simple how much Satefy, Durability and Sustainability need to be focused in Door Engines. Although it's not the whole part of door engines in Seoul Metro Line, And Metro No.4's door engines are operated by the method called mixture of mechanical type and belt type. And the last one is being used in the brand-new Metro train line No.3 which is being operated by electricity motor, instead of the old methods which use air pressure to operate a door engine. I'm sure you will agree that Safety is the first priority of Metro train and next follow comfortability and quickness. I think all I've talked so far make it the first step for the Safety of Metro train for you to understand the unit of a Door Engine.

  • PDF

Interior Noise Reduction for Subway Railroad Vehicles (통근형 지하철의 실내소음저감)

  • 김종년;유동호;박경환
    • Proceedings of the KSR Conference
    • /
    • 1998.05a
    • /
    • pp.265-272
    • /
    • 1998
  • In this paper, the intoner noise reduction for subway railroad vehicles was studied by improving transmission loss of carbody panels and side doors, and on-line tests were conducted to examine the exterior noise levels at various running conditions. Also the transmission loss for design candidates of the carbody specimen was measured in two reverberation rooms. From the results of the tests, side door gap is the most dominant factor affecting the Interior noise level of subway railroad cars with a sliding typed side door. The next one is revealed to transmission loss of a floor panel. To improve the transmission loss of the carbody, many activities were conducted such as, treatment of resilient and sound-absorbing materials and reducing the gap of the side door by adopting a brush and rubber, etc. The estimated interior noise level for modified car which is designed with improved carbody panels is lower than original car by about 5㏈.

  • PDF

Design of Face Recognition based Embedded Home Security System

  • Sahani, Mrutyunjanya;Subudhi, Subhashree;Mohanty, Mihir Narayan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.4
    • /
    • pp.1751-1767
    • /
    • 2016
  • Home security has become the prime concern for everyone in present scenario. In this work an attempt has been made to develop a home security system which is accessible, affordable and yet effective.The proposed system is based on 'Remote Embedded Control System' (RECS) which works both on the web and gsm platform for authentication and monitoring. This system is therefore cost effective as it relies on existing network infrastructure. As PCA is most popular and efficient algorithm for face recognition, it has been usedin this work. Next to it an interface has been developed for communication purpose in the embedded security system through the ZigBee module. Based on this embedded system, automated control of door movement has been implemented through electromagnetic door lock technology. This helps the users to monitor the real-time activities through web services/SMS. The web service consists of either web browser command or e-mail provision. The system establishes the communication between the system and authenticated user. The e-mail received by the system from the authorized person will monitor and control the real-time operation and door lock. The entire control system is reinforced using ARM1176JZF-S microcontroller and tested for actual use in the home environment. The result shows the experimental verification of the proposed system.

Pressure Differentials in the Elevator Lobby Depending on the Evacuation Scenarios (피난 시나리오에 따른 승강장 부속실 차압 특성 연구)

  • Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.38-43
    • /
    • 2007
  • The aim of this paper is to investigate the change of pressure differential and smoke propagation characteristics in the elevator lobby with the resident's evacuation scenarios using fire modelling technique. The results showed absolute pressures in the fire room and elevator lobby can significantly increase to cause fire door to the stairway unclosed once it is open. This is due to constant pressure differentials, the increasing reference pressure of fire lobby and pressure leak from elevator lobby to fire lobby. Smoke exhaust mechanism was needed to prevent the continuous pressure rise in the living room. Over 200 Pa was expected upon closing the door during pressurization, which provide difficulties in opening the door for next refugee. Opening both fire door and entrance door may induce smoke flow from fire room to elevator lobby and stairway.