• Title/Summary/Keyword: New-left

Search Result 1,127, Processing Time 0.022 seconds

A Study on the Left Ventricular Function Evaluation with ECG Gated Cardiac Blood Pool Scan (ECG Gated Cardiac Blood Poot Scan에서 좌심실기능(左心室機能) 분석(分析)에 관(關)한 연구(硏究))

  • Chung, June-Key;Lee, Jung-Kyoon;Kim, Kwang-Won;Lee, Myung-Chul;Cho, Bo-Yeon;Lee, Young-Woo;Koh, Chang-Soon;Han, Man-Chung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.14 no.1
    • /
    • pp.29-36
    • /
    • 1980
  • Most of clinical morbidity in cardiology are associated with abnormalities of the left ventricle. Several methods have been developed to measure the left ventricular function, including cardiac catheterization with cineangiography, echocardiography, and systolic time interval. But these methods have many limitations. ECG gated cardiac blood pool scan provides a safe, noninvasive, repeatable method for determining the left ventricular function. Utilizing the cardiac blood pool scan, we measured the left ventricular function in 165 cardiac patients, and in 26 normal subject. 1. Left ventricular ejection fractions were measured by cardiac blood pool scan, and compared in 20 patients with that measured by x-ray cineangiography. Correlation coefficient was 0.885. 2. Ejection fractions were classified by funtional class made in New York Heart Association. Ejection fractions well represented the functional status. 3. Ejection fractions decreased in cardiomyopathy ($20.1{\pm}4.8%$) and ischemic heart disease ($34.4{\pm}16.7%$). Impaired ejection fractions in myocardial infarction were associated with the extent of infarction. 4. Regional left ventricular wall motion was evaluated from the end-diastolic and end-systolic images. In cardiomyopathy diffuse hypokinesia was noted and in myocardial infarction akinesia was noted on the infarcted areas.

  • PDF

Robust model matching design using normalized left coprime factorization approach

  • Hanajima, Naohiko;Eisaka, Toshio;Yanagita, Yoshiho;Tsuchiya, Takeshi;Tagawa, Ryozaburo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.360-365
    • /
    • 1993
  • In this paper, we propose a new design procedure of the Robust Model Matching(RM) using the Normalized Left Coprime Factorization (NLCF) approach. The RMM aims at reducing the sensitivity of a given control system, but standard design procedures are not for robust stability. Therefore we try applying the robust stability condition based on NLCF to RMM procedure. We first formulate the RMM using the robust stability condition of NLCF approach, then we propose the new procedure of the RMM. The point is that the condition includes the measure of sensitivity of the RMM. In the proposed procedure, a cost function is determined through the condition and solved by H$_{\infty}$ contro technique. Finally we show a design example and check the performance..

  • PDF

Scintigraphic Detection of Mammary Tumor in a Bitch (암캐에서 유전 종양의 핵의학적 진단)

  • 강성수;김명환;배춘식;최석화
    • Journal of Veterinary Clinics
    • /
    • v.18 no.4
    • /
    • pp.469-473
    • /
    • 2001
  • A 12-year-old bitch, Yorkshire terrier, was admitted to the Chungbuk National University animal hospital with draining from mammary masses in the left and right mammary glands. She was involved in the mammary masses, suffering bilateral inguinal hernia. Physical examination during the hospitalization demonstrated the masses in right (3 cm) and left (1.5 cm) mammary glands. Blood pool images didn\`t show the subtle increase in blood flow to the inguinal hernia, and the increase of radionuclide distribution to the mammary gland on the soft tissue phase. However, delayed bone images showed a very focal lesion in the right mammary gland. These findings were confirmed on a subsequent biopsy, which also revealed adenocarcinoma with areas of malignant new bone formation. We present a case of primary mammary adenocarcinoma with $^{99m}Tc-MDP$ activity relative to normal bone. Tumor in the bitch demonstrates malignant new bone formation as the likely mechanism for the marked radiotracer avidity.

  • PDF

One-half Sternal Turnover; New Operative Approach for Asymmetrical Funnel Chest (절반 흉골반전법;비대칭 누두흉에 대한 새로운 수술기법의 제안)

  • 이승열
    • Journal of Chest Surgery
    • /
    • v.26 no.12
    • /
    • pp.969-971
    • /
    • 1993
  • The sternal turnover has a limited use in an asymmetrical funnel chest. However we tried `One-half sternal turnover` as a new operative approach for an asymmetrical funnel chest. Through the bilateral submammary skin incision, median sternotomy was made from xiphoid process to midsternum and extended horizontally. The segment of ribs were cut at the angle of depression. The en-bloc resected chest wall segment contained one-half sternum as well as a part of ribs and left half of rectus muscle. After turning over the en-bloc segment, reapproximation with wiring was done. Sternotomy wound was closed in layer after placing of substernal drainage tube. Postoperatively, the chest wall was stable and the recovery course was uneventful except left-sided minimal pneumothorax which was cured spontaneaously. The patient was discharged on postoperative 14th day.

  • PDF

Permanent Transvenous Endocardial Pacemaker Inevitably Implanted Two Electrode Leads (두개의 전극도자를 사용하게 된 Permanent Transvenous Pacemaker Implantation: 1례 보고)

  • Kwack, Moon-Sub;Lee, Hong-Kyun
    • Journal of Chest Surgery
    • /
    • v.14 no.2
    • /
    • pp.168-174
    • /
    • 1981
  • Since cardiac pacemaker was first totally implanted by Chardack, Gage and Greatbatch [1966], the electrical circuity of the cardiac pacemaker has been improved, modified, and refined. The problem of transvenous electrodes, however, is still remained; this may be due to electrode displacement, exit and/or entrance block, lead fracture and insulation defects. In permanent cardiac pacing, Irreversible loss of function of the transvenous electrode catheter eventually requires insertion of new lead. Authors now report one case that disclosed easy displacement of electrode tip in early phase of implantation and then two years and five months later, malfunctioning electrode could not be withdrawn from the cardiovascular system because it has become firmly enclosed by fibrous tissue along its course from the vein tract to the right ventricle. Under such circumstances, the electrode catheter tip was left in tricuspid annulus after being sutured at its entrance and burying the loop of lead in generator pocket. New other one electrode was then reimplantation through left external jugular vein.

  • PDF

New record of three oxytrichid ciliates (Ciliophora: Oxytrichidae) from South Korea

  • Kyu-Seok, Chae;Gi-Sik, Min
    • Journal of Species Research
    • /
    • v.11 no.4
    • /
    • pp.287-295
    • /
    • 2022
  • Three oxytrichid ciliates, Oxytricha lithofera Foissner, 2016, Pleurotricha curdsi (Shi et al., 2002) Gupta et al., 2003 and Sterkiella tetracirrata Kumar et al., 2015, were isolated from soils and confirmed as new to South Korea. Oxytricha lithofera was identified based on lithosomes, cortical granules, 21-33 adoral zone membranelles, one left (14-21 cirri) and one right (15-18) marginal rows and 5 transverse cirri. Pleurotricha curdsi was identified based on the possession of 2 macronuclear nodules, 2-3 micronuclei, 46-53 adoral zone membranelles, 3 frontal cirri, 5 frontoventral cirri, 5-7 postoral ventral cirri, 2-3 right marginal rows and 5 transverse cirri. Sterkiella tetracirrata was identified with respect 4 macronuclear nodules, 3-6 micronuclei, 25-40 adoral zone membranelles, 3 frontal cirri, 3 postoral ventral cirri, 2 pretransverse cirri, one left (21-30 cirri) and one right (24-30) marginal row and 4 transverse cirri. On the basis of 18S rDNA sequence analyses, we describe the phylogenetic positions of the three species.

New Atrial Anastomosis Technique for an Inadequate Left Atrial Cuff in Lung Transplantation

  • Son, JeongA;Hyun, Seungji;Haam, Seokjin;Kim, Do Hyung
    • Journal of Chest Surgery
    • /
    • v.55 no.5
    • /
    • pp.425-427
    • /
    • 2022
  • In lung transplantation surgery, the pulmonary veins are anastomosed by connecting each atrium of the donor and recipient. However, occasionally the recipient's left atrium is not suitable for anastomosis for various reasons. In these cases, several techniques for atrial anastomosis have been introduced, but these are somewhat complicated for an inexperienced surgeon. Here, we propose a new atrial anastomosis technique that is easier and safer than previously introduced techniques.

A New CPW Dual Band Wilkinson Power Divider Using Composite Right/Left-Handed Transmission Line (Composite Righg/Left-Hand 전송선로를 이용한 새로운 이중대역의 CPW 윌킨슨 전력 분배기)

  • Zhang, Zufu;Wang, Yang;Yoon, Ki-Cheol;Lee, Jong-Chul
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.14 no.6
    • /
    • pp.117-124
    • /
    • 2015
  • In this paper, a new kind of wideband, low-loss composite right/left-handed (CRLH) transmission line (TL) and a Wilkinson power divider are presented. The TL is composed of a parallel meander inductor and a series cutting capacitor based on coplanar waveguide (CPW) structure. The power divider is designed by substituting the CRLH-TL into the conventional transmission line. The experiment results show that the TL has a good agreement with the desired results, exhibiting the return losses under 12 dB from 8.4 GHz to 34.4 GHz. The operating frequencies of the power divider are 12.05 GHz to 13.15 GHz and 16.50 GHz to 19.30 GHz, respectively. The 20 dB bandwidths are 8.9 % and 17.9 %, respectively. Typical experimental measurements are conducted and compared with the simulated results.

Hemodynamics of a Connecting conduit Between the Left Ventricle and the Left Decending Coronary Artery

  • Shim, Eun-Bo;Sah, Jong-Yub
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.2
    • /
    • pp.20-29
    • /
    • 2003
  • A new treatment for coronary artery occlusive disease is being developed in which a shunt or conduit is placed directly connecting the left ventricle with the diseased artery at a point distal to the obstruction. To aid in assessing and optimizing its benefit, a computational model of the cardiovascular system was developed and used to explore various design conditions. Simulation results indicate that in complete LAD occlusion, flow can be returned to approximately 65% of normal if the conduit resistance is equal for forward and reverse flow, increasing to 80% in the limit in which backflow resistance is infinite. Increases in flow rate produced by asymmetric flow resistance are considerably enhanced in the case of a partial LAD obstruction since the primary effect of resistance asymmetry is to prevent leakage back into the ventricle("steal") during diastole. Increased arterial compliance has little effect on net flow with a symmetric shunt, but leads to considerable augmentation when the resistance is asymmetric. These results suggest that an LV-LAD conduit will be beneficial when stenosis resistance(Rst) > 27 PRU if resistance is symmetric.

  • PDF

Traumatic ventricular septal defect - One case report - (외상성 심실중격결손증 1례 보)

  • 성후식
    • Journal of Chest Surgery
    • /
    • v.20 no.2
    • /
    • pp.411-415
    • /
    • 1987
  • We have experienced a rare case of traumatic ventricular septal defect caused by fall down injury. The patient suffered from congestive heart failure after trauma and represented new developing typical murmur. Cardiac catheterization revealed a large left-to-right shunt at the ventricular level and a 4.4:1 ratio of pulmonary to systemic flow. Left ventricular angiogram also showed ventricular septal defect low in the muscular septum. At operation, the right ventricle and pulmonary artery were found to be moderately dilated. A marked systolic thrill was palpable over the right ventricle near the apex. Through a small left ventriculotomy an oval defect, 2x.3 cm with a firm scarred margin, was found in the lower muscular ventricular septum. This defect was repaired using Dacron patch and ventriculotomy was closed with long strip of Teflon felt. Postoperative course was uneventful and discharged in good condition.

  • PDF