• Title/Summary/Keyword: New renewable energy system

Search Result 1,388, Processing Time 0.027 seconds

Sensitivity Analysis of the Power System Considering the Load Power Factor While using Direct Load Control (부하 역률을 고려한 직접부하제어 실행시 계통의 민감도 분석)

  • Chae, Myeong-Suk
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.333-336
    • /
    • 2015
  • Recently, the power load is growing larger and because of the environmental limitation of generation, the expansion of generation facilities are becoming more difficult. For that reason the importance of the demand-side resources come to be higher. One method of the demand-side resource, the DLC Program, has executed, and moreover, the loads which are available to be controlled are increasing. It should be considered of some kinds of power system components such as DLCs, because the fact that using the demand resources will be an important part of the power system. This paper considers the power factor of the load-bus which is shedded in the direct load control program. and then analyze the power system using flow sensitivity and voltage sensitivity. In this paper, we assumed two scenarios through the rank of the load power factor at each bus and to compare and evaluate each case, we used Power World for the simulation.

Development of 50W Solid Oxide Fuel Cell system (50W 고체 산화물 연료전지 시스템 구축)

  • Jee, Young-Seok;Lah, Se-Yun;Cho, Goo-Young;Cha, Suk-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.311-314
    • /
    • 2009
  • Recently by the development of the electronic engineering technology various mobile devices are developed. But their operation time need to be extended although capacity of the batteries are limited. We focused our attention to the portable SOFC system. Because SOFC has the high efficiency and a lot of strongness in comparison with other kinds of fuel cells, We evaluated hydrogen fed SOFC 50W system theoretically and got the results about the operating condition range from the comparison of the power efficiency, exhaust gas temperature, required heat for maintaining the operation temperature and operation time.

  • PDF

Study on the Performance Ratio of PV System for Capability (용량별 태양광 시스템의 발전 성능에 관한 연구)

  • Park, Jaegyun;Yi, Somi
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.107.2-107.2
    • /
    • 2011
  • 태양광발전 시스템의 성능 평가는 신뢰할 수 있는 데이터의 취득 및 분석을 통하여 발전성능을 제시할 수 있다. 발전성능에 영향을 미치는 요인으로는 일사량과 온도 등의 환경적인 요인, 시스템 구성에 따른 기술적인 요인에 의해 결정될 수 있다. 특히, 시스템 구성에 의해 결정되는 기술적인 요인은 태양전지 모듈의 어레이 손실 및 BOS의 자체 손실 등을 분석하여 전체 시스템의 발전성능을 분석하여 그 성능을 평가할 수 있다. 본 논문에서는 기 설치된 태양광발전 시스템에서 취득된 데이터를 통하여 용량별, 지역별에 따른 태양광발전 시스템의 성능 분석과 손실 원인을 분석하였다. 분석결과 시스템의 성능은 환경적인 요인과 기술적인 요인에 의해 발전성능이 달라진다는 것을 확인할 수 있었다. 본 논문의 결과는 향후 태양광 발전 시스템의 성능의 기준을 제시하는 연구를 위한 사전연구로써 유용한 자료가 되리라 믿는다.

  • PDF

System Design for 20W Portable Fuel Cell (20W급 휴대용 연료전지 시스템 설계)

  • Jee, Young-Seok;Ko, Jeong-Sik;Cha, Suk-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.161-165
    • /
    • 2007
  • Recently by the development of the electronic engineering technology various mobile devices are developed. But their operation time need to be extended although capacity of the batteries are limited. We focused our attention to the portable SOFC system. Because SOFC has the high efficiency and a lot of strongness in comparison with other kinds of fuel cells. In addition they can be built as a self/non-reformable system and single/dual chamber system. So We evaluated some types of SOFC theoretically, and compared the results from the fuel and performance efficiency point of view.

  • PDF

Performance Analysis of 100kWp Photovoltaics System in Tibet (중국 티베트 지역의 100kWp급 태양광발전시스템 성능분석)

  • Kim, Seok-Ki;Choi, Bong-Ha;Park, Soo-Uk;Song, Jin-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.284-287
    • /
    • 2007
  • This paper presents the performance evaluation of PV systems installed at Tibet area of China in order to identity the key factors that determines system operation at a severe climate conditions and promote the cooperation of PV technology between Korea and China. The installed systems consist of 100kW on-grid connected PV systems, BOS(balance of systems), data acquisition and transmission equipments. The Korea side supplied the solar cell, BOS like as inverter, control box and monitoring system. And the Chinese side assembled solar module, constructed site and built control house. It has been shown that the average radiation per monthly from Tibet is 1.5 times larger than that from Mokpo. Also, radiation time from Tibet is 2hour higher than that from Korea. The economical analysis has shown that with the current prices, investment in a grid connected PV systems is generally profitable

  • PDF

Economic feasibility of 1kw household PEMFC System in Korea and Japan (한국과 일본에서의 가정용 PEMFC 시스템 경제성 분석)

  • Oh, Si-Doek;Kim, Ki-Young;Seo, Seok-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.105-108
    • /
    • 2007
  • Fuel cell with high electric efficiency has many probabilities of commercial use. Especially, proton exchange membrane fuel cell (PEMFC) which is a low temperature fuel cell and has less influence on $CO_2$ concentration is considered the power generation system of small building and household. We calculated the optimal operational plans of 1 kW household PEMFC power system based on the daily electricity and heat demand patterns of Japan and Korea. Calculated results show that the economic feasibility of PEMFC power system is very sensitive to the cost policy of electricity and natural gas.

  • PDF

Development of Cooling System for Thermal Management and Water Balance in Fuel Cell Vehicle (연료전지 차량의 열 및 물 균형 유지를 위한 냉각 시스템 개발)

  • Kim, Seong-Kyun;Lee, Seung-Yong;Kim, Chi-Myung;Park, Yong-Sun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.113-117
    • /
    • 2006
  • This paper Is for development of cooling module in order to maintain heat and water balance in fuel cell vehicle. Thermal management system for fuel cell is disadvantage because the temperature of coolant is lower than that of ICE and heat duty of radiator is higher. By CFD simulation, cool ing module was developed for water balance of system. Hot chamber test and hot area/high altitude test on cool ing module was completed.

  • PDF

Study on the Adsorption and Desorption Enhance Effect of Oyster Shell Using Peltier Element (페르체소자를 이용한 굴패각의 흡착 및 탈착촉진효과에 관한 연구)

  • Kim, Myoung-Jun
    • Journal of Power System Engineering
    • /
    • v.17 no.1
    • /
    • pp.71-76
    • /
    • 2013
  • This study is experimentally performed for using the oyster shell as a desiccant in the batch type system. The peltier element(thermoelectric device) is used for absorbing and releasing the adsorption and desorption heat generation. The cooling and heating effects of peltier element exist in this experiment and these effects are generally known phenomena among some references. The increase in electric current induced into peltier element is effectively release the heat generation of adsorption and desorption. Consequently, the non-dimensional adsorption and desorption amount would increase with increase in electric current. However, in the case of adsorption, the increase of induced current into peltier element, the heat of cold side can not release sufficiently. So the heat of hot side of peltier is transferred into the cold side.

Cost Policy Effects of Economic Feasibility of 1kw household PEMFC System (요금 정책이 PEMFC 시스템 경제성에 미치는 영향)

  • Kim, Ki-Young;Hwang, Nam-Sun;Kong, Min-Seok;Kim, Hee-Su;Oh, Si-Doek
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.31-34
    • /
    • 2007
  • Fuel cell with high electric efficiency has many probabilities of commercial use. Especially, polymer electrolyte or proton exchange membrane fuel cell (PEMFC) which is a low operating temperature and has less influence on $CO_2$ concentration is considered the power generation system of small building and household. We calculated the optimal operational plans of 1 kW household PEMFC power system based on daily electric and heat demand patterns of various size of apartments. Calculated results show that the economic feasibility of PEMFC power system is very sensitive to the cost policy of electricity and natural gas.

  • PDF

The Relationship between Wind Power Generation Grid-connected Transformer Winding Connection and Fault Current in MATLAB & SIMULINK (MATLAB & SIMULINK에서 풍력발전 계통연계 변압기결선과 고장전류와의 관계)

  • An, Hae-Joon;Kim, Hyun-Goo;Jang, Gil-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.307-309
    • /
    • 2008
  • This study suggests a modeling of grid-connected wind turbine generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by matlab&simulink. The simulation shall be performed by assuming single line to ground fault generated in the system. Generator power, generator rotor speed, generator terminal current and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method.

  • PDF