• Title/Summary/Keyword: New renewable energy system

Search Result 1,388, Processing Time 0.029 seconds

A Study on Operating Characteristics and Design Factors of Floating Photovoltaic Generating Facilities (수상태양광 발전시스템의 운영특성 및 설계요소에 관한 연구)

  • Kim, Hyun-Han;Kim, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.10
    • /
    • pp.1532-1539
    • /
    • 2017
  • The floating photovoltaic system is a new concept in the renewable energy technology. That is similar to land based photovoltaic technology except floating system. So the system needs buoyant objects, mooring, ect, besides modules and supports, and that is able to withstand in water level changes and wind strength. Therefore the floating photovoltaic system is much different from land photovoltaic system. K-water (Korea Water Resources Corporation) has been operating two floating photovoltaic system that's capacity is 100 kW and 500 kW respectively since in summer 2011 for commercial generation, and have construction project for 2,000 kW in Boryeong multipurpose Dam and other areas. Furthermore K-water was developing a tracking-type floating photovoltaic system at Daecheong multipurpose Dam and developed and installed an ocean floating photovoltaic demonstration plant at Sihwa Lake in October 2013 for R&D. In this paper, we introduce that structure of floating photovoltaic system include buoyant structure, mooring system and auxiliary device. Especially the rope which is in part of mooring should be always maintain tension under any water level. Also we explain about structure design concept to wind load in an every loading condition and a kind of structure materials and PV structure types used in water environment. Especially ocean floating PV system is affected by tidal current and typhoon. So there are considering the elements in design. Finally we compare with floating and land photovoltaic on power amount. As a result of that we verified the floating photovoltaic system is more about 6.6~14.2 % efficiency than a general land photovoltaic system.

A Study on the Characteristic Analysis of a Grid-connected Induction Generator for Wind Power Systems on Simulink (Simulink에서 계통연계 유도형 풍력발전시스템의 특성해석에 대한 연구)

  • An, Hae-Joon;Kim, Hyun-Goo;Jang, Moon-Seok;Jang, Gil-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.184.3-184.3
    • /
    • 2010
  • This study suggests a modeling of grid-connected wind turbine generation systems and performs simulation according to increase/decrease of real wind speed. MATLAB & SIMULINK implemented modeling of grid-connected wind turbine generation system. Terminal voltage, grid voltage, and active/reactive power shall be observed following the performance of simulation.

  • PDF

Recent Trends of Power Generation System in New and Renewable Energy (신재생에너지 발전시스템 기술동향)

  • Yu, Chul-Ro
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.161-162
    • /
    • 2011
  • 신재생에너지는 자연계에 존재하는 에너지원으로 이용하는 이상의 속도로 재생되는 에너지원이다. 그 에너지원은 태양, 풍력, 조력 등으로 사실상 고갈되지 않는 에너지원이며 또한 수력, 태양광, 태양열, 조력, 풍력, 지열, 바이오매스 등의 형태로 이용된다. 이들 에너지원은 직접, 또는 간접적으로 이용하는 경우가 있다.

  • PDF

Modular Photovoltaic PCS with High-frequency Isolation (고주파 절연 모듈형 Photovoltaic PCS)

  • Kwon, Jung-Min;Kwon, Bong-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.132-135
    • /
    • 2005
  • A modular photovoltaic PCS with high-frequency isolation is proposed. The proposed system consists of a SEPIC converter and a full-bridge inverter. Using the power slope versus voltage of the PV array, the MPPT controller is proposed that produces a smooth transition to the maximum power point. The disturbance of the line voltage is detected using a fast sensing technique. Experimental results obtained on a 500W prototype show high performance such as almost unity power factor, $90\%$ power efficiency, $3.6\%$ THD.

  • PDF

Design and Commissioning on Waste Tire Pyrolysis Demonstration Plant with Disk Moving Tube Reactor System (디스크이동식 폐타이어 열분해 실증설비 설계와 시운전)

  • Kim, Seong-Yeon;Kim, Ki-Kyung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.456-459
    • /
    • 2008
  • The 10t/d pyrolysis demonstration plant for waste tire recycling have been constructed and operated for commissioning of the plant. The plant have the tube reactor with chain conveyer attached disk. The reactor temperature is 500$\sim$600deg.C and pressure is -80$\sim$-100mmHg. Non-condensable gas is used as fuel for pyrolysis heat source.

  • PDF

농산 폐기물을 이용한 xylose, arabinose, cellulose 생산공정

  • Sin, Hyeon-Seung;Yu, Yeon-U
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.286-298
    • /
    • 2005
  • 농산 폐자원으로부터 식품 및 의약품 소재로 쓰이는 xylose, arabinose, cellulose를 생산하였다. 농산 폐자원은 우리나라 실정에 적합한 볏짚과 옥수수 껍질을 선택하였으며, 공정수율은 xylose와 arabinose는 약 15$\sim$20%(w/w), cellulose 는 20%(w/w)로 나타났다. 폐자원을 활용하는 개발된 공정중에는 미생물 유전자 재조합 기술을 응용하여 고역가의 효소생산 system을 개발하여, 생산된 효소를 가수분해 공정 과정에 투입하여 경제성이 높고 친환경적인 기술로 확립하였다. 재조합 미생물과 xylose, arabinose 정제공정은 신뢰 높은 재연성을 나타냈으며 xylose 제조법과 xylitol 발효법은 package 형태로 기술 이전을 준비하고 있다.

  • PDF

Performance Evaluation of Open-Loop Ground Water Heat Pump system (개방형 지열히트펌프 시스템의 성능평가)

  • Kim, Tae-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.9-14
    • /
    • 2006
  • Open loop or ground water heat pump systems are the oldest of ground-source systems. Standing column wells can be used as highly efficient ground heat exchanger in geo-thermal heat pump systems, where hydrological and geological conditions are suitable. These systems require some careful considerations for well design, ground water flow, heat exchanger selection etc This paper describes 9round water temperature variations, performances in heat ins and cool ing mode and the results of ground water analysis.

  • PDF

A Study on the New Renewable Energy Hybrid Power Generation/Storage System for Buildings (빌딩용 신재생에너지 하이브리드 발전/저장 시스템에 관한 연구)

  • Jung, Bong-hoon;Park, Ga-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.214-215
    • /
    • 2019
  • 최근 신재생에너지 시스템의 보급 및 확산에 따라 자가발전시스템에 관한 연구가 활발히 이루어지고 있다. 특히 도시의 빌딩에 에너지를 효율적으로 공급 및 관리하기 위해 다양한 발전원의 하이브리드 시스템의 필요성이 대두되고 있다. 본 논문에서는 태양광(PV, Photovoltaic), 연료전지(FC, Fule Cell), 바나듐 레독스 흐름전지(VRFB, Vanadium Pedox Flow Battery)를 사용하여 도시형에 적합한 빌딩용 신재생에너지 하이브리드 발전/저장 시스템을 제안한다.

  • PDF

Ground Surface Temperature Distribution of Korea (우리나라 지표면 온도 분포)

  • Koo, Min-Ho;Song, Yoon-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.431-433
    • /
    • 2006
  • Accurate information on the ground surface temperature is essential for design of a borehole heat exchanger and thus ensuring the performance of a ground source heat pump system along with knowledge on thermal diffusivity and conductivity of ground. In this study we analyzed the shallow subsurface temperature monitoring data of 58 Korea Meteorological Administration synoptic stations. As a result, we compiled mean annual ground surface temperature distribution map using multiple regression analysis of the monitoring data.

  • PDF