• Title/Summary/Keyword: New renewable energy system

Search Result 1,388, Processing Time 0.031 seconds

Economic Analysis of GHG Emission Reduction Methodology in Pulp, Paper and Wood Industry Approved by Korea Voluntary Emission Reduction Program (온실가스배출 감축사업(KVER) 제지목재 분야 인증 감축방법의 경제성 분석)

  • Kim, Young Min;Song, Myung Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.1
    • /
    • pp.39-43
    • /
    • 2015
  • The Energy and Green House Gas target management system was launched by the Korean Government in 2010. The Korea Emission Trading System will start in 2015. Therefore, simultaneous pursuit of energy saving and greenhouse emission reduction through energy use rationalization is an important obligation of Korean engineers, who import about 97% of domestic energy consumption. Economic analysis of the GHG emission reduction methodologies registered and approved by Korea Voluntary Emission Reduction (KVER) program was conducted. The results for waste heat recovery employed in an energy intensive pulp, paper and wood industry were reported. The emission reduction intensities were 9.7 kg $CO_2$/ton_pulp production. Net Present Value analysis showed that the GHG emission reduction was economically beneficial with an internal rate return of 60%. The results of exergy analysis indicated that the second law efficiencies of waste heat recovery system employed in KVER program were 77.3% and 53.6%. NPV decreased as the exergy decreased.

Study on the Application of PV System for Apartment Buildings (공동주택을 위한 PV시스템 적용에 관한 연구)

  • Yi, So-Mi;Noh, Ji-Hee;Lee, Yong-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.276-279
    • /
    • 2007
  • This study aims to present the application of pv system for apartment buildings. Regarding to the domestic housing politics to improve residing environment and effective use of country land, apartment buildings have been constructed since early of 1790's. Now apartment is taking over 50% out of entire housing in Korea. PV System of apartment buildings has been developed periodically and recently gable roof or canopy is popular which pv installation is more favorable. For balcony part with double skin facade sassy window, it has a preferable condition to install on the wall depending on the window direction. In case of superhigh floor apartment buildings where facade is mostly double skin facade of curtain wall system, pv module can replace the traditional curtain wall and will reduce architectural materials and obtain various out look design thereof. So, the purpose of this research is a basic study for clean energy source and present to applicability of pv systems for apartment buildings in preliminary design step.

  • PDF

Investigation of Research & Development Trends for Sunlight System (태양광 채광 시스템의 기술개발동향에 관한 조사분석연구)

  • Kim, Sun-Ho;Yoon, Kwang-Sik;Kim, Byung-Cheol
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.260-263
    • /
    • 2007
  • The importance of natural light in building is known by all of us who experienced dark rooms. The sunlight system is very important from energy saving and human welfare point of view. The system consists of light-collecting module, light -transporting module and light-emitting module. The light-collection is used light reflection mirror, a prism for lighting bent, and lens for light condensing. The transportation of collected sunlight is used polished duct, tube, pipe and specially used fiber optic cable. This paper investigate research and development trends of sunlight system for advanced product.

  • PDF

A Study on the BMS(Battery Management System) of Active Cell Balancing System using Lithium Ion Battery for Efficient Energy Management (효율적인 에너지 관리를 위해 리튬이온 배터리를 적용한 능동 셀 벨런싱 시스템 BMS(Battery Management System)에 관한 연구)

  • Kim, Jae-Jin
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2017.07a
    • /
    • pp.388-389
    • /
    • 2017
  • 본 논문에서는 효율적인 에너지 관리를 위해 리튬이온 배터리를 적용 능동 셀 밸런싱 시스템 BMS에 대해 제안하였다. 제안된 방법은 다수의 셀과 하나의 커패시터로 구성된 SSC(Single Switched Capacitor) 방식에서 사용되는 커패시터를 리튬이온 배터리로 변경하여 적용한 것이다. SSC 방식은 커패시터의 방향성으로 인하여 홀수 번째와 짝수 번째의 배터리에 대해 별도의 스위치를 설치하여야 하며 조작이 복잡하다는 단점을 가지고 있었다. 이러한 단점을 보완하여 커패시터를 리튬이온 배터리로 대체하여 셀의 순서에 상관없이 적용이 가능한 셀 밸런싱 방법을 제안하였다. 제안된 방법의 효율성은 BMS를 구현하여 실험 하였다. 실험 결과 셀 밸런싱이 기존의 SSC 방식보다 개선되어 효율성이 입증되었다.

  • PDF

Study on the Basic Design of Large Scale Solar Thermal Power Plant System (대규모 태양열 발전시스템 기본설계 특성 분석)

  • Kim, Jong-Kyu;Kang, Yong-Heack;Kim, Jin-Su;Lee, Sang-Nam;Yu, Chang-Kyun;Yun, Hwan-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.576-579
    • /
    • 2006
  • This paper describes characteristics and procedure of the basic design of large scale solar thermal power plant system. The evaluation is based on the operating data of CESA-I, solar central receiver plant. In order to evaluate the solar irradiation on the receiver, it is necessary to calculate the amount of thermal energy consumption at steam turbine and storage system in the STPPS. Especially, it is need to take into account of the storage and operating time to design a plant efficiently. In addition, basic design is performed for the CESA-I using the software tool of THERMOFLEX program. Based on the results, It is at lowed to use the program to investigate detail performance of each units of the STPPS by varying the operating conditions.

  • PDF

A study on the design and performance of a stand-alone photovoltaic lighting system (독립형 태양광 조명 시스템의 설계 및 성능 평가 연구)

  • Kwon, Oh-Sang;Seo, Yu-Jin;Huh, Chang-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.4
    • /
    • pp.1-10
    • /
    • 2004
  • In view of global environmental problems and resource exhaustion, we must develop new energy resources that are abundant and provide substitutes for fossil fuels. Renewable energies, such as solar, are ideal because they are clean, inexhaustible, and available everywhere in the world. Photovoltaic(PV) system, in general, are operated as a stand-alone, grid-tied, or hybrid system. Many of the stand-alone PV systems are installed. Although the pre-installation cost of PV system is high, it poorly has been operated due to the absence of optimal management standards. Therefore a study on the performance of PV system is important for the system design and maintenance. In this paper a photovoltaic lighting system was resigned according to load consumption. Then a PV lighting system which used electrodeless lamp as a load was installed. In order to investigate the system operating characteristics we've added a monitoring system to the PV lighting system. The monitoring system using the LabVIEW program regularly checks the operation of the PV lighting system and records the system data. According to the system data, the stability and availability of the PV lighting system were evaluated.

A new lightweight network based on MobileNetV3

  • Zhao, Liquan;Wang, Leilei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.1
    • /
    • pp.1-15
    • /
    • 2022
  • The MobileNetV3 is specially designed for mobile devices with limited memory and computing power. To reduce the network parameters and improve the network inference speed, a new lightweight network is proposed based on MobileNetV3. Firstly, to reduce the computation of residual blocks, a partial residual structure is designed by dividing the input feature maps into two parts. The designed partial residual structure is used to replace the residual block in MobileNetV3. Secondly, a dual-path feature extraction structure is designed to further reduce the computation of MobileNetV3. Different convolution kernel sizes are used in the two paths to extract feature maps with different sizes. Besides, a transition layer is also designed for fusing features to reduce the influence of the new structure on accuracy. The CIFAR-100 dataset and Image Net dataset are used to test the performance of the proposed partial residual structure. The ResNet based on the proposed partial residual structure has smaller parameters and FLOPs than the original ResNet. The performance of improved MobileNetV3 is tested on CIFAR-10, CIFAR-100 and ImageNet image classification task dataset. Comparing MobileNetV3, GhostNet and MobileNetV2, the improved MobileNetV3 has smaller parameters and FLOPs. Besides, the improved MobileNetV3 is also tested on CPU and Raspberry Pi. It is faster than other networks

Experimental Study on the Optimal Heat Exchanger of Thermoelectric Generation System for Industrial and Automobile Waste Heat Recovery (차량 및 산업설비 폐열회수용 열전발전시스템의 최적 열교환 시스템에 관한 실험적 연구)

  • Chung, Jae-Hoon;Kim, Woo-Chul;Lee, Jin-Ho;Yu, Tae-U.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.460-463
    • /
    • 2008
  • A large part of the overall industrial energy is dissipated as waste heat despite of much development in the utilization of thermal energy. A mean efficiency is reported to be only around 30 to 35%. The existing waste heat recovery technology has reached its limit and consequently, the development of a new technology is necessary. Improving efficiency using thermoelectric technology has recently come into the spotlight because of its unique way to recover thermal energy. In fact, thermoelectric generator directly converts thermal energy into electric energy by a solid state without any moving parts. Futhermore remarkable improvement in the thermoelectric energy conversion efficiency has been achieved. In this study, a thermoelectric generator was made using commercialized thermoelectric modules. With thermoelectric modules attached on a duct surface, hot air was blown into the duct using a hot air blower. On the other side of the module, a water jacket was attached to cool the module. With different air inlet temperatures and water flowrates, the electrical power of the thermoelectric generator was measured.

  • PDF

Technical feasibility study for power generation from a potential mini hydro site nearby Shoolini University

  • Pundir, Anil;Kumar, Anil
    • Advances in Energy Research
    • /
    • v.2 no.2
    • /
    • pp.85-95
    • /
    • 2014
  • Small Hydro-Power (SHP) is an environmental friendly technology. Usually hydro power generation projects are viewed as constructing large dams and reservoirs but available new research and engineering techniques have helped hydro power generation without large dams and without large reservoirs. In India, there are several water installations, irrigation dams, canals, streams or running rivers not tapped to generate power. In these cases the existing system and facilities can help in generating power with less investment and time. This area is yet unexplored. Harnessing a stream for hydroelectric power is a major undertaking for the energy crises and the global issues to go green. In this technical note a potential site for mini hydro power plant nearby Shoolini University is identified and examined for the economic feasibility.

GIS Data Modeling Plan for Tidal Power Energy Development in Incheon Bay of Korea (인천만 조력에너지 개발을 위한 GIS 데이터모델링)

  • Oh, Jung-Hee;Choi, Hyun-Woo;Park, Jin-Soon;Lee, Kwang-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.166.2-166.2
    • /
    • 2011
  • Incheon Bay of Korea is one of the most famous regions for high tidal range. Ministry of Land, Transport and Maritime Affairs(MLTM) has implemented preliminary investigation for tidal power energy development in this area since 2006. Through field observations, various kinds of marine data consisting of depth and geography, marine weather, tidal currents, wave, seawater characteristics, geology, marine ecosystem and marine environment were gathered. To use these data efficiently for the determining of feasibility of developing and appropriateness of project scale, spatial data management and application system is essential. Therefore, in this study, the concept, methodology and procedure of spatial data modeling are defined for tidal energy development. Spatial data modeling consists of essential model relating to tidal energy directly and optional model including environmental factors. Essential model is composed with fundamental elements like as depth, geography, and several numerical modeling results(tide, tidal current, wave).

  • PDF