• Title/Summary/Keyword: New renewable energy system

Search Result 1,388, Processing Time 0.027 seconds

Great capacity Generator of Wind Turbine (대용량 출력 풍력발전기 설계)

  • Hur, Man-Cheol
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.366-368
    • /
    • 2007
  • Mr. Hur has developed the 7500KW permanent magnet synchronous generator. The 7500KW generator has dual blade system with vertical axis type generation module. The 7500KW generator will generating that it is too expensive and construction payment. The advantages of dual blade system are cheap in generation with better efficiency, and safety compact structure. But also this system has the expensive slide ring for to distribute electrical power.

  • PDF

Study of Antifreeze Coolant for Fuel Cell System using the vehicle (연료전지 시스템 자동차용 부동 냉각액 연구)

  • Jo, Chang-Ryeol;Lee, Hong-Ki;Jeong, Jae-Hoon;Lee, Mi-Ji
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.205-208
    • /
    • 2007
  • We aim to develop antifreezing coolant used to in the 200kW Fuel Cell system that is possible to starting at low temperature and that must not to be freezed under $-30^{\circ}C$, have high coductivity, excellent system protection ability and durability.

  • PDF

Research for geothermal analysis on design of Standing Column Well type system (우물관정(SCW: Standing Column Well)형 지열 냉난방 시스템 설계를 위한 지중열 해석에 관한 연구)

  • Kwon, Ik-Sang;Rhee, Kwon-Joong;Kim, Tae-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.576-580
    • /
    • 2009
  • This thesis identified basic design elements(Sustained Yield, Depth of Well, Separation Distance between wells) regarding installation of Standing Column Well, Geothermal Heat pump System by dynamic analysis.

  • PDF

Global Case Study to Setup Establishment Strategy of National Wind Map (국가바람지도 구축전략 수립을 위한 해외사례 분석)

  • Hwang, Hyo-Jung;Kim, Hyun-Goo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.458-459
    • /
    • 2009
  • This global case study pursues diversification and intensification for an application system of the national wind map which has been developed to support national strategy building and promotion of wind energy dissemination. We chose nine counties' national wind maps and compared their map area, extraction height, temporal and spatial resolution, download services, etc. to derive a best practice for the Korea wind map application system. Therefore, the application system are designed to offer high resolution height information of which covers wind turbine rotor sweeping area and time-series dataset which can be downloaded for further analysis by users. It is anticipated that the system would contribute greatly to wind energy policy, business and research sectors once the derived ideas have been implemented to the application system

  • PDF

Environmental Effect Analysis for PV system using LCA (LCA를 이용한 태양광발전의 환경영향분석)

  • Choi, Bong-Ha;Park, Soo-Uk;Lee, Deok-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.737-741
    • /
    • 2007
  • This paper analyses the environmental effect of 100kw PV system installed in Tibet using Life Cycle Assessment(LCA). Then, energy payback time(EPT) and life-cycle $CO_2$ emission rate are estimated based on life-cycle of the PV system. As a result of the estimation, 6 year of EPT and 20 g-C/kWh of $CO_2$ emission rate are obtained. In China, average $CO_2$ emission rate of fossil fuel power generation plant is 260 g-C/kWh. This shows that PV system would be very promising for global environmental issues. For advanced LCA, we need to collect detailed and various data about raw material of PV system.

  • PDF

Optimal Design of Air Compressor-Driving Quadratic Linear Actuator in Fuel Cell BOP System Using Orthogonal Arrays Matrix

  • Kim, Jae-Hee;Kim, Jin-Ho;Jang, Chang-Hwan
    • Journal of Magnetics
    • /
    • v.16 no.2
    • /
    • pp.120-124
    • /
    • 2011
  • The design of an air compressor-driving quadratic linear actuator in a fuel cell BOP system is studied using orthogonal techniques. The approach utilizes an orthogonal array for design of 'experiments', i.e. the scheme for numerical simulations using a finite element method. Eco-friendly energy is increasingly important due to the depletion of fossil fuels and environmental pollution. Among the new energy sources, fuel cell is spotlighted as renewable energy because it produces few dusts. The air compressor performance is directly related to the efficiency of the fuel cell BOP system has high power consumption. In this paper, an optimized technique using an orthogonal matrix is applied to the design problem to improve the performance of quadratic linear actuator.

Study on the PV Driven Dehumidifying System with Oyster Shell and Thermoelectric Device (굴패각과 열전소자를 이용한 태양광 구동형 제습시스템에 관한 연구)

  • Kim, Myoung-Jun;Chea, Gyu-Hoon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.3
    • /
    • pp.287-293
    • /
    • 2012
  • This paper has dealt with the probability of oyster shell desiccant cooling system driven by renewable energy of photo-voltaic effect. For this, fundamental experiments have been carried out focusing on the observation of dehumidifying effect of oyster shell and peltier elements used for air conditioning system. From this study, it is found that oyster shell has sufficient probability for using as a desiccant in air-conditioning system. Moreover, the heat releasing device(peltier element) can be used with direct current from PV cells so the system can be operated with high efficiency. As a result, the absolute humidity in a test chamber was reasonably controlled by oyster shell and peltier elements. Also the photo-voltaic energy from sun was enough for running power of this system.

Evaluation on Performance of Hybrid Heating System with Solar Collector of Thermosyphon Tube Type (열사이폰관형 태양열집열기를 주열원으로 하는 하이브리드 난방시스템 성능 평가)

  • Chun, Tae-Kyu;Yang, Young-Joon
    • Journal of Energy Engineering
    • /
    • v.21 no.4
    • /
    • pp.356-361
    • /
    • 2012
  • Recently, even though the researches on renewable energy like geothermal, wind, solar energy have been performed widely, its use-rate in total energy is still low. This study was carried out to investigate the performance of hybrid heating system, which consisted of solar collector of thermosyphon tube type and X-L pipe boiler. Especially, new type of solar collector was tried and compared with double tube type and, futhermore, performance and safety on X-L pipe boiler were investigated. As the results, efficiency of solar collector of thermosyphon tube type was higher 20.7% than that of double tube type, mainly due to its structural characteristics. It was also confirmed that temperature of special heat medium used X-L pipe boiler rose up about 20% rapidly in comparison with that of pure water.

Design Checklist for Self-sufficient Zero Energy Solar House(ZeSH) (에너지자립형 태양열 주택의 설계 및 시공 방법 체크리스트 수립 연구)

  • Yoon Jongho;Baek Namchoon;Yu Changkyun;Kim Jongil
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.416-421
    • /
    • 2005
  • Most of solar system dissemination has been focused on domestic hot water system of which utilization to a building is relatively simple and safe than solar heating system. Through the survey on a cause of solar house dissemination failure in Korea, we conclude that design integration and systematic approach method for technology application are the most important element for a successful solar house. KIER(Korea Institute of Energy Research) and Hanbat National University have started new project on a development of Zero energy Solar House, called ZeSH which can be sustained just by natural energy without the support of existing fossil fuel. This is the 1st phase research of 10 years long-term ZeSH plan which develops a low-cost and $100\%$ self sufficient ZeSH. The goal of 1st phase ZeSH research is to get a $70\%$ self sufficiency only in thermal loads. Actual demonstration house, named KIER ZeSH I was designed and constructed as a result of 1st phase research work in the end of 2002. Various innovative technologies such as super insulation, high performance window, passive and active solar systems, ventilation heat recovery system are applied and evaluated to the KIER ZeSH I. A lot of computer simulations had been conducted for the optimal design and system integration in every design steps. Considering all the results from detailed hourly computer simulation, it is expected that at least $70\%$ self-sufficiency in thermal loads which is 1st phase target value can be excessively achieved in actual demonstration house. Besides, many valuable findings from the design and analysis to construction could be established such as collaboration method among the participants, practical design and construction techniques for system integration and the others. The purpose of this paper is to introduce the main findings through the development of KIER ZeSH I project. Practical guidelines in every design step for new low- or zero- energy solar house is proposed as result.

  • PDF

A Detailed Survey of Solar Energy Resources in East Asia Areas (동아시아 지역의 태양에너지 자원 정밀조사)

  • Jo, Dok-Ki;Kang, Young-Heak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.150-153
    • /
    • 2008
  • Since the solar radiation is the main input for sizing any solar photovoltaic system, it will be necessary to understand and evaluate the solar radiation data. The works presented here are the analysis of solar radiation data for East Asia areas. The data, which consist of the global radiation on horizontal surface, were measured at 16 different stations over the South Korea and were estimated by using satellite at 12 different stations over the North Korea from 1982 to 2004. Also the data over the Japan have been collected for 30 years for the period from 1941 to 1970. The Result of the analysis shows that the annual-average daily global radiation on the horizontal surface is 3.55 kWh/$m^2$. We conclude, based on the analysis, that East Asia areas have sufficient solar energy resources for the photovoltaic power generation system.

  • PDF