• Title/Summary/Keyword: New renewable energy system

Search Result 1,388, Processing Time 0.032 seconds

A Study on System Optimization according to the Supply Obligations Rate of New and Renewable Energy at an Indoor Gymnasium (실내체육관의 신재생에너지 공급의무비율에 따른 시스템 최적화 연구)

  • Park, Yun-Ha;Kim, Yun-Ho;Won, An-Na;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.6
    • /
    • pp.51-60
    • /
    • 2015
  • In statutes on the promotion of distribution of new and renewable energy, which were revised in 2014, daylight system and fuel cell were added in addition to existing new and renewable energy sources. This study, therefore, aimed at setting up targets for the introduction of daylight system and analyzing the installation rate of new and renewable energy which can be provided by daylight system for the aggressive use of daylight system, thereby deducting the optimal combination ratio with other new and renewable energy sources. The results of the study are as follows. First, when a prism-shaped daylight system was installed to a round indoor gymnasium among domestic indoor gymnasiums, out of a supply obligations allotment rate of 15% of new and renewable energy, the rate of daylight system was basically set at 2.5%. Second, therefore, with daylight system coming first, the lacked supply obligations rate was taken up by solar photovoltaic, solar heat and geothermal heat. In addition, using the KRESS Program, economic, technical, environmental and complexity evaluations for the upper 5% was made, deducting the optimal ratio of the system. The results produced the following optimal combination ratios: solar photovoltaic (83.3%) in economic evaluation, solar heat (8.3%) and geothermal heat (75%) in technical evaluation, solar photovoltaic (83.3%) in environmental evaluation, and solar photovoltaic (83.3%, the same as in economic evaluation) in complexity evaluation.

Investigation of Thermal Management Parameters of Metal Hydride Based Hydrogen Storage System (금속수소화물 기반 수소저장시스템의 열관리 인자 조사)

  • PARK, CHU SIK;KIM, JONG WON;BAE, KI KWANG;JEONG, SEONG UK;KANG, KYOUNG SOO
    • Journal of Hydrogen and New Energy
    • /
    • v.29 no.3
    • /
    • pp.251-259
    • /
    • 2018
  • Metal hydride based hydrogen storage under moderate temperature and pressure gives the safety advantage over the gas and liquid storage methods. Still solid-state hydrogen storage including metal hydride is below the DOE target level for automotive applications, but it can be adapted to stationary or miliary application reasonably. In order to develop a modular solid state hydrogen storage system that can be applied to a distributed power supply system composed of renewable energy - water electrolysis - fuel cell, the heat transfer and hydrogen storage characteristics of the metal hydride necessary for the module system design were investigated using AB5 type metal hydride, LCN2 ($La_{0.9}Ce_{0.1}Ni_5$). The planetary high energy mill (PHEM) treatment of LCN2 confirmed the initial hydrogen storage activation and hydrogen storage capacity through surface modification of LCN2 material. Expanded natural graphite (ENG) addition to LCN2, and compression molding at 500 atm improved the thermal conductivity of the solid hydrogen storage material.

System Design for Activation of Renewable Energy and Cooperative Renewable Energy Plan Between South and North Korea -Based on the Survey of Renewable Energy Experts- (신.재생에너지 활성화를 위한 제도의 설계와 남북한 신.재생에너지 협력 추진방안 - 전문가 설문에 나타난 신.재생에너지 현황 -)

  • Lim, So-Young;Heo, Eun-Nyeong
    • New & Renewable Energy
    • /
    • v.1 no.3 s.3
    • /
    • pp.24-34
    • /
    • 2005
  • Ministry of Commerce, Industry [MOCIE] has taken it into consideration to introduce a Renewable Portfolio Standard (RPS) that is a purchase obligation program as an alternative plan to the FIT. We conducted a survey of renewable energy companies and experts to ask their opinions about renewable energy policy, the introduction of the RPS, and the scheme for aid of North Korea with renewable energy. Korean renewable energy companies show an impartial opinion about a FIT and a RPS system overall, although they tend to have distinctive opinions by technology each other. With respect to eligible resources for a RPS, the industries want to extend the scope of it as broad as possible. In addition, experts prefer the multi-tiered and energy production based RPS to the sing1e-tiered and installed capacity based RPS. We also conducted a surrey to find the best renewable energy sources. Wind, Geothermal, Solar-thermal, and Photovoltaic were selected to have the best potential capacities to support North Korea by renewable energy experts. However, these energy resources also have several problems to overcome in the aid of North Korea, and thus, the plans for solving them and for giving efficient support to North Korea in the area of Renewable Energy are discussed.

  • PDF

Thermal Behavior of Air Conditioning System in an Indoor Energy Storage System (실내 에너지저장시스템 공조시스템의 열적 거동에 관한 연구)

  • Kim, Junyoung;Choi, Naksam;Kim, Jintaek
    • New & Renewable Energy
    • /
    • v.17 no.1
    • /
    • pp.33-39
    • /
    • 2021
  • The energy use is increasing as the quality of human life improves. and research on the efficient use of energy in ESS (Energy Storage System) is ongoing. An air conditioner is required for the efficient use of an ESS, as are data on the distribution of the temperature of the latter based on the capacity of the air conditioner. In the absence of an air conditioner, the battery of the ESS reaches its maximum temperature of 40℃ after 2 h. When an air conditioner is present, the temperature of the battery stabilizes as the capacity of the former increases.

The Supply Status Analysis of New Renewable Energy Based on Public Obligation System (공공의무화 제도에 따른 신재생에너지 보급 실태 분석)

  • Seo, Sang-Hyun;Lee, Yong-Ho;Kim, Hyung-Jin;Cho, Young-Hum;Hwang, Jung-Ha
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.220-225
    • /
    • 2011
  • Based on the supply status statistics of new renewable energy according to public obligation system, current status of overall application centered on solar heat, solar ray, and geothermal heat as energy sources that can be applied to buildings may be analyzed as follows. (1) After the public obligation system, the investment costs on the total construction costs by years were between 5.21% and 7.12%: they were 7.12% in 2004, where the system was initially implemented; and they were gradually declined from 2005 to 2011, 5.76% in average. The ratio of equipment investment per energy sources in the total construction costs was 5.9%, which was slightly more than the obliged ratio. The order of investment costs per energy source was solar ray, geothermal heat, and solar heat. (2) Among the 1,433 sites in the plan of new renewable energy installation based on the public obligation system, "for cultural & social use" was most in target institution, and facilities for education & research was most in use classification, followed by public working, culture & rally, and sports. The number of facilities applied according to the case for planning installation per use classification of the target institution was between 1.1 and 1.5, or 1.4 in average of energy source. Conclusively, the authors of this study investigated overall current status of new renewable energy supply from the analysis of statistic data, and it may be needed of further supplementation of various examinations by visiting investigation and interviews with practitioners based on classification of use of target institutions.

  • PDF

Evaluation of the Economic Values and Optimal Deployment Timing of R&D Investment in New and Renewable Energy Using Real Option Approach (실물옵션을 이용한 신재생에너지 R&D의 경제적 가치 및 최적 적용시점 평가)

  • Kim, Kyung-Taek;Lee, Deok-Joo;Park, Sung-Joon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.38 no.2
    • /
    • pp.144-156
    • /
    • 2012
  • In recent years, advanced countries in energy sector are emphasizing the importance of the development and deployment of renewable energy to cope with the global environmental crisis such as depletion of fossil energy, climate convention to control emissions of greenhouse gases. In this paper, we evaluate the economic value of the investment in new and renewable energy R&D in Korea and optimal deployment timing of new and renewable energy by using the real option approach. The real option model adopted in this paper assumes that a decision maker has a compound option to abandon, deployment, or continue the R&D. As a result by using empirical data of Korea, it is found that there exists a considerable amount of positive real option value (ROV) in the investment of new and renewable energy R&D while its net present value (NPV) calculated by traditional discounted cash flow (DCF) model shows negative value.

A Study on the R&D Evaluation system of New & Renewable Energy (신재생에너지 평가시스템 구축)

  • Kim, Yu-Jeong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.656-659
    • /
    • 2005
  • his paper develops the systematic and quantitative priority-determining method for national investment using the framework of evaluating R&D. This study proposes multi criteria for evaluating the R&D of New & Renewable Energy through analysing the attribute of 11 types of energy. The framework is constituted by 4 criteria, the political urgency, economic impact, regional constraint. and technological attribute and the each criteria has 3 or 4 sub-criteria. These sub-criteria are weighted using AHP.

  • PDF

A Study on the Advanced Protective Coordination Schemes of 22.9[kV] Distribution System Interconnected New Renewable Energy System (신재생에너지 시스템이 연계된 22.9[kV] 배전계통의 개선된 보호협조 방안 연구)

  • Choi, Dong-Man;Choi, Joon-Ho;Ro, Kyoung-Soo;Moon, Seung-Il;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.426-428
    • /
    • 2005
  • Recently, There has been growing interest in new renewable energy systems with high-energy efficiency due to the increasing energy consumption and environmental pollution problems, but an insertion of new renewable energy systems to existing power distribution systems can cause several problems such as voltage variations, harmonics, protective coordination, increasing fault current etc, because of reverse power. This paper was applied to Sukumar M, Brahma, A. Girgis[1] proposal schemes and identilys the faulted section performing short-circuit analysis by MATLAB programs to 22.9[kV] distribution system interconnected a large number of new renewable energy system and was analyzed on protective coordination between reclose and Sectionalizer.

  • PDF

The policy study on the power grid operation strategy of new and renewable energy combined generation system (도서지역의 신재생에너지복합발전 전력계통 운영방안에 관한 정책연구)

  • Kim, Eui Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.109.1-109.1
    • /
    • 2011
  • KEPCO was operating power plants with diesel generators in 49 islands including Baekryeong-Do, and the generation capacity was about 66 MW in 2008. The cost of fuel is increasing by the international oil price inflation and continuous rise of oil price is predicted. For the stabilizing of electric power supply to the separate islands, renewable energy and fuel cell systems were considered. Hydrogen is made using renewable energy such as wind power and solar energy, and then a fuel cell system generates electricity with the stored hydrogen. Though the system efficiency is low, it is treated as the only way to secure the stable electric supply using renewable energy at this present. The analytic hierarchy process was used to select suitable candidate island for the system installation and 5 islands including Ulleung-Do were selected. Economic evaluation for the system composed of a kerosene generator, a wind power, an electrolysis, and a fuel cell system was conducted with levelized generation cost based on present value methode. As the result, the necessity of renewable energy combined generation system and micro grid composition in the candidated islands was confirmed. Henceforth, the development of an integration technology which connects micro grid to the total power grid will be needed.

  • PDF