• Title/Summary/Keyword: New health technology

Search Result 1,274, Processing Time 0.026 seconds

Qualitative Study on Experiences of Responding to COVID-19 of Therapists in Long-term Care Hospitals (요양병원 치료사의 코로나19 대응 경험에 대한 질적 연구)

  • Bae, Won-Jin;Park, Ju-Young
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.4
    • /
    • pp.337-347
    • /
    • 2021
  • This study is a qualitative study conducted to provide basic data for therapists working in long-term care hospitals to improve their countermeasure strategies for new infectious diseases and improvement of the treatment room infection management system, and to help therapists understand their infection management work. Colaizzi's phenomenological research method was applied as the research method. Telephone interviews were conducted with nine occupational therapists and physical therapists working in nursing hospitals. The contents of the interview were recorded with the consent of the study subjects, and additional confirmation was received by email. The recorded content was analyzed after transcription, and the meaning and nature of the experience coping with COVID-19 were described. The content was organized into 6 themes, 17 main meaning and 49 meaning units. In accordance with the COVID-19 situation, the infection control system has been strengthened by reinforcing infection control education in nursing hospitals, practicing infection control, and supervising infection control outside business hours. It was found that the treatment environment was changed due to the restriction of treatment activities by practicing distancing in the treatment room, adjusting rest and meal times during working hours, and strengthening infection control. In addition, the therapist's role has been expanded and the paradigm of treatment has changed, such as considering the untact intervention, and they have experienced cohort quarantine, pre-tested for COVID-19, vaccinations, and side effects from COVID-19. However, due to the infection work, the therapist's work burden is increased, and the person is experiencing fear, depression, and work stress from the spread of COVID-19. They were also aware of the need for nursing hospital care personnel support, such as guaranteeing rest after vaccination and providing infection control tools and equipment. The results of this study are expected to be used as basic data for human and physical support for the development of infectious disease response strategy programs in nursing hospital treatment rooms and for infection control in nursing hospitals.

A Study on the Improvement of Flexible Working Hours (유연근로시간제 개선에 대한 연구)

  • Kwon, Yong-man;Seo, Ei-seok
    • Journal of Venture Innovation
    • /
    • v.4 no.2
    • /
    • pp.97-108
    • /
    • 2021
  • Labor contracts appear in form as an exchange relationship between labor products and wages, but since they transcend the level of simple barter, they can be economically identified as "trading" and can be identified as "rental." From a legal point of view, a legal device that legally supports and imposes binding force on commodity exchange relations is a contract. Such a labor contract led to a relationship in which wages were received and a certain amount of time was placed under the direction and supervision of the employer as a counter benefit to the receipt of wages. Since working hours are subordinate hours with one's labor under the disposition authority of the employer, long hours of work can be done for the health and safety of workers and furthermore, it can be an act that violates the value to enjoy as a human being. The reduction of working hours needs to be shortened in terms of productivity and enjoyment of workers' culture so that they can expand and reproduce, but users' corporate management labor and production activities should also be compatible compared to those pursued by capitalist countries. Working hours can be seen as individual time and time in society as a whole, and long hours of work at the individual level are reduced, which is undesirable at the individual level, but an increase in products due to an increase in production time at the social level can help social development. It is necessary to consider working hours in terms of finding the balance between these individual and social levels. If the regulation method of working hours was to regulate the total amount of working hours, flexibility and elasticity of working hours are a qualitative regulation method that allows companies to flexibly allocate and organize working hours within a certain range of up to 52 hours per week. Accordingly, it is necessary to shorten working hours, but expand and implement the flexible working hours system according to the situation of the company. To this end, it is necessary to flexibly operate the flexible working hours system, which is currently limited to six months, handle the selective working hours by agreement between employers and workers, and expand the target work of discretionary working hours according to the development of information and communication technology and new types based on the 4th industrial revolution.

Pipetting Stability and Improvement Test of the Robotic Liquid Handling System Depending on Types of Liquid (용액에 따른 자동분주기의 분주능력 평가와 분주력 향상 실험)

  • Back, Hyangmi;Kim, Youngsan;Yun, Sunhee;Heo, Uisung;Kim, Hosin;Ryu, Hyeonggi;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.62-68
    • /
    • 2016
  • Purpose In a cyclosporine experiment using a robotic liquid handing system has found a deviation of its standard curve and low reproducibility of patients's results. The difference of the test is that methanol is mixed with samples and the extractions are used for the test. Therefore, we assumed that the abnormal test results came from using methanol and conducted this test. In a manual of a robotic liquid handling system mentions that we can choose several setting parameters depending on the viscosity of the liquids being used, the size of the sampling tips and the motor speeds that you elect to use but there's no exact order. This study was undertaken to confirm pipetting ability depending on types of liquids and investigate proper setting parameters for the optimum dispensing ability. Materials and Methods 4types of liquids(water, serum, methanol, PEG 6000(25%)) and $TSH^{125}I$ tracer(515 kBq) are used to confirm pipetting ability. 29 specimens for Cyclosporine test are used to compare results. Prepare 8 plastic tubes for each of the liquids and with multi pipette $400{\mu}l$ of each liquid is dispensed to 8 tubes and $100{\mu}l$ of $TSH^{125}I$ tracer are dispensed to all of the tubes. From the prepared samples, $100{\mu}l$ of liquids are dispensed using a robotic liquid handing system, counted and calculated its CV(%) depending on types of liquids. And then by adjusting several setting parameters(air gap, dispense time, delay time) the change of the CV(%)are calcutated and finds optimum setting parameters. 29 specimens are tested with 3 methods. The first(A) is manual method and the second(B) is used robotic liquid handling system with existing parameters. The third(C) is used robotic liquid handling system with adjusted parameters. Pipetting ability depending on types of liquids is assessed with CV(%). On the basis of (A), patients's test results are compared (A)and(B), (A)and(C) and they are assessed with %RE(%Relative error) and %Diff(%Difference). Results The CV(%) of the CPM depending on liquid types were water 0.88, serum 0.95, methanol 10.22 and PEG 0.68. As expected dispensing of methanol using a liquid handling system was the problem and others were good. The methanol's dispensing were conducted by adjusting several setting parameters. When transport air gap 0 was adjusted to 2 and 5, CV(%) were 20.16, 12.54 and when system air gap 0 was adjusted to 2 and 5, CV(%) were 8.94, 1.36. When adjusted to system air gap 2, transport air gap 2 was 12.96 and adjusted to system air gap 5, Transport air gap 5 was 1.33. When dispense speed was adjusted 300 to 100, CV(%) was 13.32 and when dispense delay was adjusted 200 to 100 was 13.55. When compared (B) to (A), the result increased 99.44% and %RE was 93.59%. When compared (C-system air gap was adjusted 0 to 5) to (A), the result increased 6.75% and %RE was 5.10%. Conclusion Adjusting speed and delay time of aspiration and dispense was meaningless but changing system air gap was effective. By adjusting several parameters proper value was found and it affected the practical result of the experiment. To optimize the system active efforts are needed through the test and in case of dispensing new types of liquids proper test is required to check the liquid is suitable for using the equipment.

  • PDF

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF