• Title/Summary/Keyword: New Materials

Search Result 10,194, Processing Time 0.046 seconds

A Study on Dietary Behavior of Chinese Consumers Segmented by Dietary Lifestyle (중국 현지 소비자들의 식생활 라이프스타일 세분화에 따른 식행동 연구)

  • Oh, Ji Eun;Yoon, Hei-Ryeo
    • Journal of the Korean Society of Food Culture
    • /
    • v.32 no.5
    • /
    • pp.383-393
    • /
    • 2017
  • This study was conducted to analyze the dietary lifestyle of local Chinese consumers and to classify dietary characteristics according to their dietary lifestyle factors and dietary behaviors. This investigation was conducted for 1 month from 1 January 2017 targeting 300 adult males and females living in China using the online survey company surveymonkey. Four factors relating to dietary lifestyle were identified, gourmet factor, healthy factor, convenience factor and economic factor, and these were grouped into 4 clusters according to their dietary lifestyle factor scores. Group 1, the gourmet economy group, showed a high percentage of living alone and a high frequency of eating out, but a relatively low percentage of three regular meals per day. Their dietary lifestyle was sensitive to gourmet factors and economic factors, but less sensitive to health and convenience factors. Group 2, the wide interest group, contained a high percentage of individuals in their 30s, as well as more highly educated individuals and a higher income than other groups. Because their dietary lifestyle scores tended to be higher than those of other groups, they sought a variety of new foods and gourmet meals for enjoyment of dining and life, as well as well-being food materials and foods related to health. Group 3, the health economic group, constituted a family-type consumer group with lower income level than the other groups. Members of this group were seeking health food and natural food in their dietary lifestyle and tended to pursue a high economic profit ratio when purchasing food. Finally, group 4 showed a relatively higher percentage of women over 30 and individuals with a college level or higher education than the other groups. This group was more interested in health and taste than price and convenience, and showed the highest LOHAS orientation among middle aged Chinese women. Moreover, members of this group directly utilized their knowledge regarding nutrition in real life.

The Palliative Radiation Therapy in Malignant Extra-Hepatic Biliary Obstruction (간외 폐쇄성 황달 환자에서 고식적 방사선치료의 결과)

  • Kay Chul-Seoung;Jang Hong-Suk;Kim Sung-hwan;Ryu Mi-Ryeong;Kim Yeon-Shil;Chung Su-Mi;Yoon Sei-Chul
    • Radiation Oncology Journal
    • /
    • v.17 no.3
    • /
    • pp.209-216
    • /
    • 1999
  • Purpose : To evaluate the effectiveness of external radiation therapy and the prognostic factors, we retrospectively analyzed therapeutic results of malignant extrahepatic biliary obstruction (EHBO). Methods and Materials : We analyzed the results of the external radiation therapy in 59 patients of inoperable malignant EHBO who had been treated with more than 10 Gy of external radiation therapy from April 1984 to December 1990. There were 21 stomach cancer ($35.6\%$), 12 pancreas cancer ($20.3\%$), 15 extrahepatic biliary cancer ($18.0\%$) and 11 another cancer ($18.0\%$). Their pathologies were confirmed in 31 patients ($52.5\%$). They divided into 27 adenocarcinoma and 4 nonadenocarcinoma. Their chief complaints were jaundice in 47 patients ($79.7\%$) and abdominal pain in 15 patients ($49.2\%$). Twelve patients had slightly increased bilirubin level in liver function test without jaundice. We treated twenty four patients ($40.6\%$) with percutaneous transhepatic biliary drainage (PTBD) and 32 patients ($54\%$) with systemic chemotherapy (CT). We performed external radiation therapy (ERT) upto $10.8\~55.8$ Gy (median 37.8 Gy) with palliative aim. Results : Overall median survival duration was $7.80\pm1.15$ months. The response rates of jaundice were $81.8\%$ in PTBO group and $66.7\%$ in non-PTBD group without statistical significance. The improving rate of jaundice was not significantly different in decreased ratio of total bilirubin level. But abdominal pain was more decreased in CT group than non-CT group (p<0.05). The significant prognostic factors were high performance status (Karnofski Performance Status >70), total radiation dose more than 35 Gy and good response of pain after therapy. There were increased in bacterial cholagitis in PTBD group and gastrointestinal complications in CT group. Conclusion : External radiotheapy could improve jaundice and abdominal pain in malignant EHBO patients, Overall survival duration was prolonged in patients with higher performance status and patients who had been treated with more than 35 Gy of total radiation dose. In the future, we expect not only better palliative role but also the prolongation of survival of using the ERT combined with other treatment method. But to achieve certain conclusion, we need luther study consisted with many kinds of treatment methods including new technologies in RT.

  • PDF

Preoperative Concurrent Radio-chemotherapy for Rectal Cancer: Report of Early Results (직장암에 대한 수술 전 동시병용 방사선-항암 화학요법: 초기 치료결과 보고)

  • Shin, Seong-Soo;Ahn, Yong-Chan;Chun, Ho-Kyung;Lee, Woo-Yong;Kang, Won-Ki;Park, Young-Suk;Park, Joon-Oh;Song, Sang-Yong;Lim-Do-Hoon;Park, Won;Lee, Jung, Eun;Kang, Min-Kyu;Park, Yung-Je
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.125-134
    • /
    • 2003
  • Purpose: To report the early results of preopeartive concurrent radio-chemotherapy (CRCT) for treating rectal cancer. Materials and Methods: From June 1999 to April 2002, 40 rectal cancer patients who either had lesions with a questionable resectability or were candidates for sphincter-sacrificing surgery received preoperative CRCT. Thirty-seven patients completed the planned CRCT course. 45 Gy by 1.8 Gy daily fraction over 5 weeks was delivered to the whole pelvis in the prone position. The chemotherapy regimens were oral UFT plus oral leucovorin (LV) in 12 patients, intravenous bolus 5-FU plus LV in 10 patients, and intravenous 5-FU alone in 15 patients (bolus infusion in 10, continuous infusion in 5). Surgery was planned in 4$\~$6 weeks of the completion of the preoperative CRCT course, and surgery was attempted in 35 patients. Results: The compliance to the current preoperative CRCT protocol was excellent, where 92.5$\%$ (37/40) completed the planned treatment. Among 35 patients, in whom surgery was attempted after excluding two patients with new metastatic lesions in the liver and the lung, sphincter-preservation was achieved in 22 patients (62.9$\%$), while resection was abandoned during laparotomy in two patients (5.7$\%$). Gross complete resection was peformed in 30 patients, gross incomplete resection was peformed in one patient, and no detailed information on the extent of surgery was available in two patients. Based on the surgical and pathological findings, the down-staging rate was 45.5$\%$ (15/33), and the complete resection rate with the negative resection margin 78.8$\%$ (26/33). During the CRCT course, grade 3 $\~$4 neutropenia developed in four patients (10.8$\%$). Local recurrence after surgical resection developed in 12.1$\%$ (4/33), and distant metastases after the preoperative CRCT start developed in 21.6$\%$ (8/37). The overall 3-years survival rate was 87$\%$. Conclusion: Preoperative CRCT in locally advanced rectal cancer is well tolerated and can lead to high resection rate, down-staging rate, sphincter preservation rate, however, longer term follow-up will be necessary to confirm these results.

Suggestion of Learning Objectives in Social Dental Hygiene: Oral Health Administration Area (사회치위생학의 학습목표 제안: 구강보건행정 영역)

  • Park, Su-Kyung;Lee, Ga-Yeong;Jang, Young-Eun;Yoo, Sang-Hee;Kim, Yeun-Ju;Lee, Sue-Hyang;Kim, Han-Nah;Jo, Hye-Won;Kim, Myoung-Hee;Kim, Hee-Kyoung;Ryu, Da-Young;Kim, Min-Ji;Shin, Sun-Jung;Kim, Nam-Hee;Yoon, Mi-Sook
    • Journal of dental hygiene science
    • /
    • v.18 no.2
    • /
    • pp.85-96
    • /
    • 2018
  • The purpose of this study is to propose learning objectives in social dental hygiene by analyzing and reviewing learning objectives in oral health administration area of the existing public oral health. This study is a cross-sectional study. The subjects of the study selected with convenience extraction were 15 members of the social dental hygiene subcommittee of the Korean Society of Dental Hygiene Science. Data collection was conducted by self-filling questionnaire. The research tool is from 48 items of A division in the book of learning objectives in the dental hygienist national examination, and this study classified each of them into 'dental hygiene job relevance', 'dental hygiene competency relevance', 'timeliness', and 'value discrimination of educational goal setting' to comprise 192 items. Also, to collect expert opinions, this study conducted Delphi survey on 7 academic experts. Statistical analysis was performed using the IBM SPSS Statistics ver. 23.0 program (IBM Co., Armonk, NY, USA). Recoding was performed according to the degree of relevance of each learning objective and frequency analysis was performed. This study removed 18 items from the whole learning objectives in the dental hygienist national examination in the oral health administration area of public oral health. Fifteen revisions were made and 15 existing learning objectives were maintained. Forty-five learning objectives were proposed as new social dental hygiene learning objectives. The topics of learning objectives are divided into social security and medical assistance, oral health care system, oral health administration, and oral health policy. As a result of this study, it was necessary to construct the learning objectives of social dental hygiene in response to changing situation at the time. The contents of education should be revised in order of revision of learning objectives, development of competency, development of learning materials, and national examination.

The Results of Curative Radiotherapy for the Uterine Cervical Cancer (자궁경부암의 근치적 방사선치료 성적)

  • Kim, Hyoung-Jin;Kim, Jung-Soo;Kwon, Hyoung-Cheol;Kim, Jin-Kee;Oh, Byung-Chan
    • Radiation Oncology Journal
    • /
    • v.14 no.3
    • /
    • pp.191-199
    • /
    • 1996
  • Purpose : To evaluate 5-year survival rate, patterns of failure and complications of cervical cancer treatment, fifty nine patients treated by curative radiotherapy for the uterine cervical cancer were analyzed retrospectively. Materials and Methods : From March 1986 to May 1990, fifty nine patients with histologically proven uterine cervical cancer were analyzed. According to FIGO stage, there were 2 patients ($3.4\%$) in stage Ib, 2 patients ($3.4\%$) in stage IIa, 31 patients ($52.5\%$) in stage IIb, 15 patients ($25.4\%$) in stage IIIb, 9 patients ($15.3\%$) in stage IV. External RT was per formed by 6 MVLINAC with daily 1.8 Gy, 5 times per week and followed by ICR. A point dose of ICR was calculated to 30-43.66 Gy (median: 34.6 Gy). These techniques delivered total A Point dose of 80.4 to 109.8 Gy (median: 85 Gy). Patients had been followed up from 2 to 110 months (median: 61 months) Results : The overall 5-year survival rate & disease free survival rate were $55.9\%$ and $55.0\%$ respectively. According to FIGO stage, the 5-year survival rate for less than IIa, IIb, IIIb, IV were $75.0\%$, $74.8\%$, $26.7\%$, $33.3\%$, respectively. In univariate analysis, the 5-year survival rate for stage IIb and below versus stage IIIa and above revealed $74.8\%$, $29.2\%$ respectively (P<0.005). According to the hemoglobin level during RT, the 5-rear survival rate of was $73.3\%$ for patients with Hg 10 gm/dL or higher, in contrast to $0\%$ for those with lower than 10 gm/dL (p<0.005). In 18 patients with nonbulky tumor (<5cm), the 5-year survival rates were $71.8\%$. The 5-rear survival rates for 18 patients with 5 cm or greater in tumor diameter were $22.2\%$ (p<0.005). The 5-year survival rate for Patient age of above 50 years and below were $65.3\%$ $34.2\%$ respectively (p<0.05). ECOG performance status. pathologic finding, total dose, total treatment time were not statistically significant factors. The significant prognostic factors affecting overall 5-year survival rate by multivariate analysis showed the hemoglobin level during RT (P=0.0001), tumor size (p=0.0390), FIGO stage (p=0.0468). Total recurrence rate was $23.7\%$ local failure $15.2\%$ (9/59), distant metastasis $6.8\%$ (4/59), local and distant metastasis $1.7\%$ (1/59). According to the RTOG/EORTC Soma Scales, the late complication rate was $23.8\%$ (14/59) The late complication rate of colorectum and genitourinary tract were $15.3\%$ (9/59), $8.5\%$ (5/59), respectively: 10 patients ($17.0\%$) were grade 2, 3 Patients ($5.1\%$) were grade 3 and one patient ($1.7\%$) was grade 4. The late complications were radiation proctitis, rectal bleeding, radiation colitis, diarrhea and radiation cystitis in decreasing order. Conclusion : For improvement of therapeutic results, prospective randomized trials are recomended to discover new prognostic factors and more aggressive radiation therapeutic methods are needed for poor prognostic patients. The adjuvant chemotherapy or radiation-sensitizing agents must be considered to inhibit regional and distant metastasis.

  • PDF

Open Digital Textbook for Smart Education (스마트교육을 위한 오픈 디지털교과서)

  • Koo, Young-Il;Park, Choong-Shik
    • Journal of Intelligence and Information Systems
    • /
    • v.19 no.2
    • /
    • pp.177-189
    • /
    • 2013
  • In Smart Education, the roles of digital textbook is very important as face-to-face media to learners. The standardization of digital textbook will promote the industrialization of digital textbook for contents providers and distributers as well as learner and instructors. In this study, the following three objectives-oriented digital textbooks are looking for ways to standardize. (1) digital textbooks should undertake the role of the media for blended learning which supports on-off classes, should be operating on common EPUB viewer without special dedicated viewer, should utilize the existing framework of the e-learning learning contents and learning management. The reason to consider the EPUB as the standard for digital textbooks is that digital textbooks don't need to specify antoher standard for the form of books, and can take advantage od industrial base with EPUB standards-rich content and distribution structure (2) digital textbooks should provide a low-cost open market service that are currently available as the standard open software (3) To provide appropriate learning feedback information to students, digital textbooks should provide a foundation which accumulates and manages all the learning activity information according to standard infrastructure for educational Big Data processing. In this study, the digital textbook in a smart education environment was referred to open digital textbook. The components of open digital textbooks service framework are (1) digital textbook terminals such as smart pad, smart TVs, smart phones, PC, etc., (2) digital textbooks platform to show and perform digital contents on digital textbook terminals, (3) learning contents repository, which exist on the cloud, maintains accredited learning, (4) App Store providing and distributing secondary learning contents and learning tools by learning contents developing companies, and (5) LMS as a learning support/management tool which on-site class teacher use for creating classroom instruction materials. In addition, locating all of the hardware and software implement a smart education service within the cloud must have take advantage of the cloud computing for efficient management and reducing expense. The open digital textbooks of smart education is consdered as providing e-book style interface of LMS to learners. In open digital textbooks, the representation of text, image, audio, video, equations, etc. is basic function. But painting, writing, problem solving, etc are beyond the capabilities of a simple e-book. The Communication of teacher-to-student, learner-to-learnert, tems-to-team is required by using the open digital textbook. To represent student demographics, portfolio information, and class information, the standard used in e-learning is desirable. To process learner tracking information about the activities of the learner for LMS(Learning Management System), open digital textbook must have the recording function and the commnincating function with LMS. DRM is a function for protecting various copyright. Currently DRMs of e-boook are controlled by the corresponding book viewer. If open digital textbook admitt DRM that is used in a variety of different DRM standards of various e-book viewer, the implementation of redundant features can be avoided. Security/privacy functions are required to protect information about the study or instruction from a third party UDL (Universal Design for Learning) is learning support function for those with disabilities have difficulty in learning courses. The open digital textbook, which is based on E-book standard EPUB 3.0, must (1) record the learning activity log information, and (2) communicate with the server to support the learning activity. While the recording function and the communication function, which is not determined on current standards, is implemented as a JavaScript and is utilized in the current EPUB 3.0 viewer, ths strategy of proposing such recording and communication functions as the next generation of e-book standard, or special standard (EPUB 3.0 for education) is needed. Future research in this study will implement open source program with the proposed open digital textbook standard and present a new educational services including Big Data analysis.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF

Evaluation of the Usefulness of MapPHAN for the Verification of Volumetric Modulated Arc Therapy Planning (용적세기조절회전치료 치료계획 확인에 사용되는 MapPHAN의 유용성 평가)

  • Woo, Heon;Park, Jang Pil;Min, Jae Soon;Lee, Jae Hee;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.115-121
    • /
    • 2013
  • Purpose: Latest linear accelerator and the introduction of new measurement equipment to the agency that the introduction of this equipment in the future, by analyzing the process of confirming the usefulness of the preparation process for applying it in the clinical causes some problems, should be helpful. Materials and Methods: All measurements TrueBEAM STX (Varian, USA) was used, and a file specific to each energy, irradiation conditions, the dose distribution was calculated using a computerized treatment planning equipment (Eclipse ver 10.0.39, Varian, USA). Measuring performance and cause errors in MapCHECK 2 were analyzed and measured against. In order to verify the performance of the MapCHECK 2, 6X, 6X-FFF, 10X, 10X-FFF, 15X field size $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$ direction was measured by the energy. IGRT couch of the CT values affect the measurements in order to confirm, CT number values : -800 (Carbon) & -950 (COUCH in the air), -100 & 6X-950 in the state for FFF, 15X of the energy field sizes $10{\times}10$, gantry $180^{\circ}$, $135^{\circ}$, $275^{\circ}$ directionwas measured at, MapPHAN allocated to confirm the value of HU were compared, using the treatment planning computer for, Measurement error problem by the sharp edges MapPHAN Learn gantry direction MapPHAN of dependence was measured in three ways. GANTRY $90^{\circ}$, $270^{\circ}$ in the direction of the vertically erected settings 6X-FFF, 15X respectively, and Setting the state established as a horizontal field sizes $10{\times}10$, $90^{\circ}$, $45^{\circ}$, $315^{\circ}$, $270^{\circ}$ of in the direction of the energy-6X-FFF, 15X, respectively, were measured. Without intensity modulated beam of the third open arc were investigated. Results: Of basic performance MapCHECK confirm the attenuation measured by Couch, measured from the measured HU values that are assigned to the MAP-PHAN, check for calculation accuracy for the angled edge of the MapPHAN all come in a range of valid measurement errors do not affect the could see. three ways for the Gantry direction dependence, the first of the meter built into the value of the Gantry $270^{\circ}$ (relative $0^{\circ}$), $90^{\circ}$ (relative $180^{\circ}$), 6X-FFF, 15X from each -1.51, 0.83% and -0.63, -0.22% was not affected by the AP/PA direction represented. Setting the meter horizontally Gantry $90^{\circ}$, $270^{\circ}$ from the couch, Energy 6X-FFF 4.37, 2.84%, 15X, -9.63, -13.32% the difference. By-side direction measurements MapPHAN in value is not within the valid range can not, because that could be confirmed as gamma pass rate 3% of the value is greater than the value shown. You can check the Open Arc 6X-FFF, 15X energy, field size $10{\times}10$ cm $360^{\circ}$ rotation of the dose distribution in the state to look at nearly 90% pass rate to emerge. Conclusion: Based on the above results, the MapPHAN gantry direction dependence by side in the direction of the beam relative dose distribution suitable for measuring the gamma value, but accurate measurement of the absolute dose can not be considered is. this paper, a more accurate treatment plan in order to confirm, Reduce the tolerance for VMAT, such as lateral rotation investigation in order to measure accurate absolute isodose using a combination of IMF (Isocentric Mounting Fixture) MapCHEK 2, will be able to minimize the impact due to the angular dependence.

  • PDF

Pipetting Stability and Improvement Test of the Robotic Liquid Handling System Depending on Types of Liquid (용액에 따른 자동분주기의 분주능력 평가와 분주력 향상 실험)

  • Back, Hyangmi;Kim, Youngsan;Yun, Sunhee;Heo, Uisung;Kim, Hosin;Ryu, Hyeonggi;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.62-68
    • /
    • 2016
  • Purpose In a cyclosporine experiment using a robotic liquid handing system has found a deviation of its standard curve and low reproducibility of patients's results. The difference of the test is that methanol is mixed with samples and the extractions are used for the test. Therefore, we assumed that the abnormal test results came from using methanol and conducted this test. In a manual of a robotic liquid handling system mentions that we can choose several setting parameters depending on the viscosity of the liquids being used, the size of the sampling tips and the motor speeds that you elect to use but there's no exact order. This study was undertaken to confirm pipetting ability depending on types of liquids and investigate proper setting parameters for the optimum dispensing ability. Materials and Methods 4types of liquids(water, serum, methanol, PEG 6000(25%)) and $TSH^{125}I$ tracer(515 kBq) are used to confirm pipetting ability. 29 specimens for Cyclosporine test are used to compare results. Prepare 8 plastic tubes for each of the liquids and with multi pipette $400{\mu}l$ of each liquid is dispensed to 8 tubes and $100{\mu}l$ of $TSH^{125}I$ tracer are dispensed to all of the tubes. From the prepared samples, $100{\mu}l$ of liquids are dispensed using a robotic liquid handing system, counted and calculated its CV(%) depending on types of liquids. And then by adjusting several setting parameters(air gap, dispense time, delay time) the change of the CV(%)are calcutated and finds optimum setting parameters. 29 specimens are tested with 3 methods. The first(A) is manual method and the second(B) is used robotic liquid handling system with existing parameters. The third(C) is used robotic liquid handling system with adjusted parameters. Pipetting ability depending on types of liquids is assessed with CV(%). On the basis of (A), patients's test results are compared (A)and(B), (A)and(C) and they are assessed with %RE(%Relative error) and %Diff(%Difference). Results The CV(%) of the CPM depending on liquid types were water 0.88, serum 0.95, methanol 10.22 and PEG 0.68. As expected dispensing of methanol using a liquid handling system was the problem and others were good. The methanol's dispensing were conducted by adjusting several setting parameters. When transport air gap 0 was adjusted to 2 and 5, CV(%) were 20.16, 12.54 and when system air gap 0 was adjusted to 2 and 5, CV(%) were 8.94, 1.36. When adjusted to system air gap 2, transport air gap 2 was 12.96 and adjusted to system air gap 5, Transport air gap 5 was 1.33. When dispense speed was adjusted 300 to 100, CV(%) was 13.32 and when dispense delay was adjusted 200 to 100 was 13.55. When compared (B) to (A), the result increased 99.44% and %RE was 93.59%. When compared (C-system air gap was adjusted 0 to 5) to (A), the result increased 6.75% and %RE was 5.10%. Conclusion Adjusting speed and delay time of aspiration and dispense was meaningless but changing system air gap was effective. By adjusting several parameters proper value was found and it affected the practical result of the experiment. To optimize the system active efforts are needed through the test and in case of dispensing new types of liquids proper test is required to check the liquid is suitable for using the equipment.

  • PDF

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF