• 제목/요약/키워드: Neutron collimator

검색결과 21건 처리시간 0.025초

Design and optimization of thermal neutron activation device based on 5 MeV electron linear accelerator

  • Mahnoush Masoumi;S. Farhad Masoudi;Faezeh Rahmani
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4246-4251
    • /
    • 2023
  • The optimized design of a Neutron Activation Analysis (NAA) system, including Delayed Gamma NAA (DGNAA) and Prompt Gamma NAA (PGNAA), has been proposed in this research based on Mevex Linac with 5 MeV electron energy and 50 kW power as a neutron source. Based on the MCNPX 2.6 simulation, the optimized configuration contains; tungsten as an electron-photon converter, BeO as a photoneutron target, BeD2 and plexiglass as moderators, and graphite as a reflector and collimator, as well as lead as a gamma shield. The obtained thermal neutron flux at the beam port is equal to 2.06 × 109 (# /cm2.s). In addition, using the optimized neutron beam, the detection limit has been calculated for some elements such as H-1, B-10, Na-23, Al-27, and Ti-48. The HPGe Coaxial detector has been used to measure gamma rays emitted by nuclides in the sample. By the results, the proposed system can be an appropriate solution to measure the concentration and toxicity of elements in different samples such as food, soil, and plant samples.

원자력병원(原子力病院) 싸이클로트론 중성자선(中性子線) 치료실(治療室)의 방사선(放射線) 방어(防禦)에 관한 총합적(總合的) 평가(評價) (Compositional Qualification of Radiation Protection in Neutron Radiotherapy Room with KCCH Cyclotron)

  • 유성열;조철구;고경환
    • Journal of Radiation Protection and Research
    • /
    • 제14권2호
    • /
    • pp.45-50
    • /
    • 1989
  • 원자력병원 싸이클로트른 중성자선(中性子線) 치료실의 방사선 준위(準位)를 측정함으로써 방사선 안전도를 검토하여 보았다. 중성자선 치료실내 방사선 노출은 주로 isocentric gantry에 내장된 중성자선 표적(標的)과 조사야(照射野)를 결정하는 collimator의 방사화(放射化)로 인한 잔류방사능(殘留放射能) (remanent radioactivity)에 의해 결정 된다. 측정결과 선량율(線量率)은 과다하지 않았고 개인 집적선량(集積線量)도 허용치 이내였다. 방사선 작업종사자로서의 의료기사는 환자치료 시 매 조사(照射) 완료 직후부터 5분간 멸살(滅殺)시간을 갖도록 조치하였다.

  • PDF

DT 중성자 발생기에 의한 중성자 검출기 반응도 조사 (Investigation of Response of Several Neutron Surveymeters by a DT Neutron Generator)

  • 김상인;장인수;김장렬;이정일;김봉환
    • Journal of Radiation Protection and Research
    • /
    • 제37권1호
    • /
    • pp.35-40
    • /
    • 2012
  • 국내 교정기관 또는 표준기관은 중성자 검출기의 교정을 위해 비감속 및 중수감속 $^{252}Cf$ 선원과 $^{241}AmBe$ 선원을 사용하고 있다. 이런 선원들로 교정된 중성자 검출기를 이용하여 입자가속기와 같이 속중성자가 다량 존재하는 시설을 선량평가할 때, 그 정확도가 떨어지게 된다. 그 이유는, 대부분의 중성자 검출기는 열중성자에 민감하게 반응하므로 수 MeV 이상의 에너지를 가지는 속중성자장에 대한 선량당량 반응도는 부정확하다. 또한 높은 에너지의 중성자는 열중성자보다 선량기여정도가 훨씬 크기 때문이다. 이와 같은 이유로, 기존의 교정용 기준 중성자장이 아닌 수 MeV 이상의 속중성자가 존재하는 중성자장에서도 검출기를 교정할 필요가 있다. DT 중성자 발생기, 흑연집합체 그리고 폴리에틸렌 중성자 집속체를 사용하여 속중성자의 선속분율이 서로 다른 중성자장을 제작하였고, 이 중성자장에서 중성자 검출기의 선량당량 반응도를 측정하였다. 시험결과에 의하면, 속중성자 선속분율과 중성자 검출기의 종류에 따라 중성자 검출기의 반응도는 많은 차이를 보였다. 이러한 반응도 차이는 선량당량의 과대 및 과소평가를 의미하므로, 검출기가 사용되는 시설환경과 유사한 중성자장에서 반응도 교정이 필요함을 확인하였다.

An investigation on the improvement of neutron radiography system of the Tehran research reactor by using MCNPX simulations

  • Amini, Moharram;Zamzamian, Seyed Mehrdad;Fadaei, Amir Hossein;Gharib, Morteza;Feghhi, Seyed Amir Hosein
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3413-3420
    • /
    • 2021
  • Applying the available neutron flux for medical and industrial purposes is the most important application of research reactors. The neutron radiography system is used for non-destructive testing (NDT) of materials so that it is one of the main applications of nuclear research reactors. One of these research reactors is the 5 MW pool-type light water research reactor of Tehran (TRR). This work aims to investigate on materials and location of the beam tube (BT) of the TRR radiography system to improve the index parameters of BT. Our results showed that a through-type BT with 20 cm thick carbon neutron filter, 1.2 cm and 9.4 cm of the diameter of inlet (D1) and output (D2) BT, respectively gives thermal neutron flux almost 25.7, 5.6 and 1.1 times greater than the former design of the TRR (with D1 = 1.8 cm and D1 = 9.4 cm), previous design of the TRR with D1 = 3 cm and D1 = 9.4 cm, and another design with D1 = 5 cm and D1 = 9.4 cm, respectively. Therefore, the design proposed in this paper could be a better alternative to the current BT of the TRR.

Characterization of a CLYC Detector and Validation of the Monte Carlo Simulation by Measurement Experiments

  • Kim, Hyun Suk;Smith, Martin B.;Koslowsky, Martin R.;Kwak, Sung-Woo;Ye, Sung-Joon;Kim, Geehyun
    • Journal of Radiation Protection and Research
    • /
    • 제42권1호
    • /
    • pp.48-55
    • /
    • 2017
  • Background: Simultaneous detection of neutrons and gamma rays have become much more practicable, by taking advantage of good gamma-ray discrimination properties using pulse shape discrimination (PSD) technique. Recently, we introduced a commercial CLYC system in Korea, and performed an initial characterization and simulation studies for the CLYC detector system to provide references for the future implementation of the dual-mode scintillator system in various studies and applications. Materials and Methods: We evaluated a CLYC detector with 95% $^6Li$ enrichment using various gamma-ray sources and a $^{252}Cf$ neutron source, with validation of our Monte Carlo simulation results via measurement experiments. Absolute full-energy peak efficiency values were calculated for gamma-ray sources and neutron source using MCNP6 and compared with measurement experiments of the calibration sources. In addition, behavioral characteristics of neutrons were validated by comparing simulations and experiments on neutron moderation with various polyethylene (PE) moderator thicknesses. Results and Discussion: Both results showed good agreements in overall characteristics of the gamma and neutron detection efficiencies, with consistent ~20% discrepancy. Furthermore, moderation of neutrons emitted from $^{252}Cf$ showed similarities between the simulation and the experiment, in terms of their relative ratios depending on the thickness of the PE moderator. Conclusion: A CLYC detector system was characterized for its energy resolution and detection efficiency, and Monte Carlo simulations on the detector system was validated experimentally. Validation of the simulation results in overall trend of the CLYC detector behavior will provide the fundamental basis and validity of follow-up Monte Carlo simulation studies for the development of our dual-particle imager using a rotational modulation collimator.

Cross Talk Experiment with Two-element CdTe Detector and Collimator for BNCT-SPECT

  • Manabe, Masanobu;Ohya, Ryosuke;Saraue, Nobuhide;Sato, Fuminobu;Murata, Isao
    • Journal of Radiation Protection and Research
    • /
    • 제41권4호
    • /
    • pp.328-332
    • /
    • 2016
  • Background: Boron Neutron Capture Therapy (BNCT) is a new radiation therapy. In BNCT, there exists some very critical problems that should be solved. One of the severest problems is that the treatment effect cannot be known during BNCT in real time. We are now developing a SPECT (single photon emission computed tomography) system (BNCT-SPECT), with a cadmium telluride (CdTe) semiconductor detector. BNCT-SPECT can obtain the BNCT treatment effect by measuring 478 keV gamma-rays emitted from the excited state of $^7Li$ nucleus created by $^{10}B(n,{\alpha})$ $^7Li$ reaction. In the previous studies, we investigated the feasibility of the BNCT-SPECT system. As a result, the S/N ratio did not meet the criterion of S/N > 1 because deterioration of the S/N ratio occurred caused by the influence of Compton scattering especially due to capture gamma-rays of hydrogen. Materials and Methods: We thus produced an arrayed detector with two CdTe crystals to test cross talk phenomenon and to examine an anti-coincidence detection possibility. For more precise analysis for the anti-coincidence detection, we designed and made a collimator having a similar performance to the real BNCT-SPECT. Results and Discussion: We carried out experiments with the collimator to examine the effect of cross talk of scattering gamma-rays between CdTe elements more practically. As a result of measurement the coincidence events were successfully extracted. Conclusion: We are now planning to carry out evaluation of coincidence rate from the measurement and comparison of it with the numerical calculations.

컨테이너 보안 검색용 9 MeV 전자 선형가속기에서 발생한 방사화 특성평가에 관한 연구 (A Study on Activation Characteristics Generated by 9 MeV Electron Linear Accelerator for Container Security Inspection)

  • 이창호;김장오;이윤지;전찬희;이지은;민병인
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.563-575
    • /
    • 2020
  • 본 연구 목적은 컨테이너 보안 검색용 선형가속기에서 발생하는 방사화 특성을 평가하는 것이다. 전산모사 설계는 첫째, 표적은 텅스텐(Z=74) 단일물질 표적 및 텅스텐(Z=74)과 구리(Z=29) 복합물질 표적으로 구성하였다. 둘째, 부채꼴(Fan beam) 조준기는 물질에 따라 납(Z=82) 단일 물질과 텅스텐(Z-74)과 납(Z=82)의 복합물질로 구성하였다. 셋째 선형가속기가 위치한 방(Room)의 콘크리트는 Magnetite type 및 불순물(Impurity)을 포함하였다. 연구 방법은 첫째, MCNP6 코드를 이용하여 선형가속기 및 구조물을 F4 Tally로 광중성자 플럭스(Flux)를 계산하였다. 둘째, MCNP6 코드에서 계산된 광중성자 플럭스를 FISPACT-II에 적용하여 방사화 생성물을 평가하였다. 셋째, 방사화 생성물의 비방사능을 통해 해체 평가를 진행하였다. 그 결과 첫째, 광중성자 분포는 표적에서 가장 높게 나왔으며, 조준기 및 10 cm 깊이의 콘크리트 순으로 나타났다. 둘째, 방사화 생성물은 텅스텐 표적 및 조준기에서 W-181, 불순물이 포함된 콘크리트에서 Co-60, Ni-63, Cs-134, Eu-152, Eu-154 핵종이 부산물(by-product)로 생성되었다. 셋째, 해체 시 텅스텐 표적은 90일 이후 자체 처분 허용 농도를 만족하는 것으로 보였다. 이러한 결과는 9 MeV 에너지에서의 광중성자 수율(Yield) 및 방사화 정도가 미미한 것으로 확인할 수 있었다. 하지만, 선형가속기 텅스텐 표적 및 조준기에서 발생한 W-181은 수리를 위한 분해 시 피폭의 영향을 줄 수 있을 것으로 생각된다. 따라서, 본 연구는 컨테이너 보안검색용 선형가속기 방사화된 부품관리에 관한 기초 자료를 제시한 것이다. 또한, 컨테이너 보안 검색용 선형 가속기 해체 시 자체처분을 만족하는 농도 기준을 입증하는데 활용될 수 있을 것으로 기대한다.

양성자 선량 분포 검증을 위한 즉발감마선 분포측정 장치 최적화 연구 (Study on Optimization of Detection System of Prompt Gamma Distribution for Proton Dose Verification)

  • 이한림;민철희;박종훈;김성훈;김찬형
    • 한국의학물리학회지:의학물리
    • /
    • 제23권3호
    • /
    • pp.162-168
    • /
    • 2012
  • 양성자 치료에서 치료의 목표를 달성하고 환자의 안전을 제고하기 위해 인체 내 양성자 빔의 분포를 확인하는 것이 중요하다. 양성자 선량분포와 밀접한 관계가 있는 즉발감마선의 2차원 분포 측정을 위하여 본 연구팀에서는 다수의 CsI(Tl) 섬광체가 1차원 종형으로 배열된 검출기 배열과 집속장치 및 다채널 신호처리 장치로 이루어진 측정장치를 개발하고 있다. 이에 본 연구에서 몬테칼로 기반의 MCNPX 코드를 이용하여 최적화된 측정 장치를 설계하고자 하였다. 즉발감마선을 효과적으로 측정하기 위해 CsI(Tl) 섬광체의 크기를 $6{\times}6{\times}50mm^3$로 결정하였으며, 배경감마선의 영향을 최소화하고 빔의 진행방향에서 수직방향으로 발생하는 즉발감마선만 측정하기 위해 집속장치의 구멍 크기는 면적 $6{\times}6mm^2$, 길이 150 mm로 최적화되었다. 150 MeV 양성자 빔에 대한 성능 예측 전산모사연구를 수행한 결과, 본 연구에서 최적화된 측정 장치를 통해 즉발감마선 2차원 분포를 측정할 수 있었으며, 1 mm 오차범위에서 양성자 빔의 비정을 결정할 수 있었다. 이를 바탕으로 현재 다채널의 신호처리 장치를 개발하고 있으며 실제 양성자 빔을 이용한 즉발감마선 분포측정을 통해 측정 장치의 성능을 검증할 것이다.

The optimization study of core power control based on meta-heuristic algorithm for China initiative accelerator driven subcritical system

  • Jin-Yang Li;Jun-Liang Du;Long Gu;You-Peng Zhang;Cong Lin;Yong-Quan Wang;Xing-Chen Zhou;Huan Lin
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.452-459
    • /
    • 2023
  • The core power control is an important issue for the study of dynamic characteristics in China initiative accelerator driven subcritical system (CiADS), which has direct impact on the control strategy and safety analysis process. The CiADS is an experimental facility that is only controlled by the proton beam intensity without considering the control rods in the current engineering design stage. In order to get the optimized operation scheme with the stable and reliable features, the variation of beam intensity using the continuous and periodic control approaches has been adopted, and the change of collimator and the adjusting of duty ratio have been proposed in the power control process. Considering the neutronics and the thermal-hydraulics characteristics in CiADS, the physical model for the core power control has been established by means of the point reactor kinetics method and the lumped parameter method. Moreover, the multi-inputs single-output (MISO) logical structure for the power control process has been constructed using proportional integral derivative (PID) controller, and the meta-heuristic algorithm has been employed to obtain the global optimized parameters for the stable running mode without producing large perturbations. Finally, the verification and validation of the control method have been tested based on the reference scenarios in considering the disturbances of spallation neutron source and inlet temperature respectively, where all the numerical results reveal that the optimization method has satisfactory performance in the CiADS core power control scenarios.