• Title/Summary/Keyword: Neutron capture

Search Result 118, Processing Time 0.021 seconds

Radioiodination strategies for carborane compounds

  • Rajkumar Subramani;Abhinav Bhise;Jeongsoo Yoo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.1
    • /
    • pp.39-44
    • /
    • 2022
  • The development of methods for the inert and stable radiohalogenation of targeted radiopharmaceuticals is a prerequisite for real-time diagnosis and therapy using radiohalogenated radiopharmaceuticals. Radiohalogenated carboranes demonstrate superior stability in vivo and versatile applications compared with directly labeled tyrosine analogues or synthetically modified organic compounds. Herein, we focus on the most common approaches for the radioiodination (123l, 124l, 125l, and 131l) of carborane derivatives.

Construction of voxel head phantom and application to BNCT dose calculation (Voxel 머리팬텀 제작 및 붕소중성자포획요법 선량계산에의 응용)

  • Lee, Choon-Sik;Lee, Choon-Ik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.2
    • /
    • pp.93-99
    • /
    • 2001
  • Voxel head phantom for overcoming the limitation of mathematical phantom in depleting anatomical details was constructed and example dose calculation for BNCT was performed. The repeated structure algorithm of the general purpose Monte Carlo code, MCNP4B was applied for yokel Monte Carlo calculation. Simple binary yokel phantom and combinatorial geometry phantom composed of two materials were constructed for validating the voxel Monte Carlo calculation system. The tomographic images of VHP man provided by NLM(National Library of Medicine) were segmented and indexed to construct yokel head phantom. Comparison of doses for broad parallel gamma and neutron beams in AP and PA directions showed decrease of brain dose due to the attenuation of neutron in eye balls in case of yokel head phantom. The spherical tumor volume with diameter, 5cm was defined in the center of brain for BNCT dose calculation in which accurate 3 dimensional dose calculation is essential. As a result of BNCT dose calculation for downward neutron beam of 10keV and 40keV, the tumor dose is about doubled when boron concentration ratio between the tumor to the normal tissue is $30{\mu}g/g$ to $3{\mu}g/g$. This study established the voxel Monte Carlo calculation system and suggested the feasibility of precise dose calculation in therapeutic radiology.

  • PDF

이성체쌍의 열중성자포획단면적비 측정

  • Park, Hy-Eil;Kim, Heon-Jun;Lee, Chul
    • Nuclear Engineering and Technology
    • /
    • v.4 no.4
    • /
    • pp.340-344
    • /
    • 1972
  • Isomeric ratios were measured for the capture of thermal neutron by $^{79}$ Br, $^{80}$ Se, $^{103}$ Rh, $^{115}$ In and $^{133}$ Cs as well as those of epi-cadmium neutron by $^{79}$ Br, $^{80}$ Se and $^{l33}$Cs. The measurements were performed by analysing decay curves obtained by ${\gamma}$-ray spectrometry after irradiation. The counting efficiency curve was determined by using the calibrated standard sources with overall uncertainties of about 1%. Isomeric ratios, given in $\sigma$ high spin/($\sigma$ high spin + $\sigma$ low spin), of $^{80, 80m}$Br, $^{81,81m}$Se, $^{014, 104m}$Rh, $^{116,116m}$In and $^{134, 134m}$Cs produced by thermal neutron activation were found to be 0.21$\pm$0.01, 0.14$\pm$0.02, 0.12$\pm$0.02, 0.69$\pm$0.07 and 0.058$\pm$0.004, respectively, Those values of $^{80, 80m}$Br, $^{81,81m}$Se, and $^{134, 134m}$Cs Produced by epi-cadmium neutron were found to be 0.19$\pm$0.02, 0.29$\pm$0.02 and 0.074$\pm$0.011, respectively. The experimental values obtained were compared with the theoretical values deduced from the statistical model. There were the general agreements between the theory and the experiment.t.

  • PDF

Borehole Elemental Concentration Logs: Theory, Current Trends and Next Level (암석구성성분검층: 원리, 연구동향 및 향후 과제)

  • Shin, Jehyun;Hwang, Seho
    • Geophysics and Geophysical Exploration
    • /
    • v.22 no.3
    • /
    • pp.149-159
    • /
    • 2019
  • Borehole elemental concentration logging, measuring neutron-induced gamma rays by inelastic scattering and neutron capture interactions between neutron and formation, delivers concentrations of the most common elements found in the minerals and fluids of subsurface formation. X-ray diffraction and X-ray fluorescence analysis from core samples are traditionally used to understand formation composition and mineralogy, but it represents only part of formations. Additionally, it is difficult to obtain elemental analysis over the whole intervals because of poor core recovery zones such as fractures or sand layers mainly responsible for groundwater flow. The development of borehole technique for in situ elemental analysis plays a key role in assessing subsurface environment. Although this technology has advanced consistently starting from conventional and unconventional resources evaluation, it has been considered as exclusive techniques of some major service company. As regards domestic research and development, it has still remained an unexplored field because of some barriers such as the deficiency of detailed information on tools and calibration facility for chemistry and mineralogy database. This article reviews the basic theory of spectroscopy measurements, system configuration, calibration facility, and current status. In addition, this article introduces the domestic researches and self-development status on borehole elemental concentration tools.

Chemical Effects of Nuclear Transformations in Metal Salts (金屬鹽의 原子核變換의 化學的 效果)

  • Byung Hun Lee;Jong Du Lee
    • Journal of the Korean Chemical Society
    • /
    • v.19 no.5
    • /
    • pp.331-338
    • /
    • 1975
  • The distribution of $^{51}Cr\;and\;^{128}I$ recoil species following radiative-neutron capture in chromates, dichromates, iodates and periodates has been investigated by using paper-electrophoresis. In view of the effective recoil energy and the effect of the internal conversion, it is unlikely that an atom which has captured a neutron can remain bound in its original molecule. It is also unlikely that the energy of the recoil atom is dissipated in heating a small region of the crystal. However, the results of paper-electrophoresis separation of recoil $^{51}Cr\;and\;^{128}I$ indicated that many more of the recoil atoms were bound in the parent molecule. The disorder model for the reaction was proposed from observations of retention. In considering cations, the greater their radii, the higher is the probability of the recoil atom breaking through the secondary cage. In ammonium salt, the ammonium ion behaved as a reducing agent in the disorder zone and resulted in low retention. Crystal structures with their greater free space have shown low retention.

  • PDF

Measurements of Neutron Activation and Dose Rate Induced by High-Energy Medical Linear Accelerator

  • Kwon, Na Hye;Jang, Young Jae;Kim, Jinsung;Kim, Kum Bae;Yoo, Jaeryong;Ahn, So Hyun;Kim, Dong Wook;Choi, Sang Hyoun
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.145-152
    • /
    • 2021
  • Purpose: During the treatments of cancer patients with a linear accelerator (LINAC) using photon beams with energies ≥8 MV, the components inside the LINAC head get activated through the interaction of photonuclear reaction (γ, n) and neutron capture (n, γ). We used spectroscopy and measured the dose rate for the LINAC in operation after the treatment ended. Methods: We performed spectroscopy and dose rate measurements for three units of LINACs with a portable high-purity Germanium (HPGe) detector and a survey meter. The spectra were obtained after the beams were turned off. Spectroscopy was conducted for 3,600 seconds, and the dose rate was measured three times. We identified the radionuclides for each LINAC. Results: According to gamma spectroscopy results, most of the nuclides were short-lived radionuclides with half-lives of 100 days, except for 60Co, 65Zn, and 181W nuclides. The dose rate for three LINACs obtained immediately in front of the crosshair was in the range of 0.113 to 0.129 µSv/h. The maximum and minimum dose rates measured on weekends were 0.097 µSv/h and 0.092 µSv/h, respectively. Compared with the differences in weekday data, there was no significant difference between the data measured on Saturday and Sunday. Conclusions: Most of the detected radionuclides had half-lives <100 days, and the dose rate decreased rapidly. For equipment that primarily used energies ≤10 MV, when the equipment was transferred after at least 10 minutes after shutting it down, it is expected that there will be little effect on the workers' exposure.

Cross Talk Experiment with Two-element CdTe Detector and Collimator for BNCT-SPECT

  • Manabe, Masanobu;Ohya, Ryosuke;Saraue, Nobuhide;Sato, Fuminobu;Murata, Isao
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.328-332
    • /
    • 2016
  • Background: Boron Neutron Capture Therapy (BNCT) is a new radiation therapy. In BNCT, there exists some very critical problems that should be solved. One of the severest problems is that the treatment effect cannot be known during BNCT in real time. We are now developing a SPECT (single photon emission computed tomography) system (BNCT-SPECT), with a cadmium telluride (CdTe) semiconductor detector. BNCT-SPECT can obtain the BNCT treatment effect by measuring 478 keV gamma-rays emitted from the excited state of $^7Li$ nucleus created by $^{10}B(n,{\alpha})$ $^7Li$ reaction. In the previous studies, we investigated the feasibility of the BNCT-SPECT system. As a result, the S/N ratio did not meet the criterion of S/N > 1 because deterioration of the S/N ratio occurred caused by the influence of Compton scattering especially due to capture gamma-rays of hydrogen. Materials and Methods: We thus produced an arrayed detector with two CdTe crystals to test cross talk phenomenon and to examine an anti-coincidence detection possibility. For more precise analysis for the anti-coincidence detection, we designed and made a collimator having a similar performance to the real BNCT-SPECT. Results and Discussion: We carried out experiments with the collimator to examine the effect of cross talk of scattering gamma-rays between CdTe elements more practically. As a result of measurement the coincidence events were successfully extracted. Conclusion: We are now planning to carry out evaluation of coincidence rate from the measurement and comparison of it with the numerical calculations.

Conceptual Core Design of 1300MWe Reactor for Soluble Boron Free Operation Using a New Fuel Concept

  • Kim, Soon-Young;Kim, Jong-Kyung
    • Nuclear Engineering and Technology
    • /
    • v.31 no.4
    • /
    • pp.391-400
    • /
    • 1999
  • A conceptual core design of the 1,300MWe KNGR (Korean Next Generation Reactor) without using soluble boron for reactivity control was developed to determine whether it is technically feasible to implement SBF (Soluble Boron Free) operation. Based on the borated KNGR core design, the fuel assembly and control rod configuration were modified for extensive use of burnable poison rods and control rods. A new fuel rod, in which Pu-238 had been substituted for a small amount of U-238 in fuel composition, was introduced to assist the reactivity control by burnable poison rods. Since Pu-238 has a considerably large thermal neutron capture cross section, the new fuel assembly showed good reactivity suppression capability throughout the entire cycle turnup, especially at BOC (Beginning of Cycle). Moreover, relatively uniform control of power distribution was possible since the new fuel assemblies were loaded throughout the core. In this study, core excess reactivity was limited to 2.0 %$\delta$$\rho$ for the minimal use of control rods. The analysis results of the SBF KNGR core showed that axial power distribution control can be achieved by using the simplest zoning scheme of the fuel assembly Furthermore, the sufficient shutdown margin and the stability against axial xenon oscillations were secured in this SBF core. It is, therefore, concluded that a SBF operation is technically feasible for a large sized LWR (Light Water Reactor).

  • PDF

The Spectra Investigation of the Halo Planetary Nebula BoBn 1

  • Hyung, Siek;Otsuka, Masaaki;Tajitsu, Akito;Izumiura, Hideyuki
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.72.2-72.2
    • /
    • 2010
  • The extremely metal-poor halo planetary nebula BoBn 1 has been investigated based on IUE archive data, Subaru/HDS spectra, VLT/UVES archive data, and Spitzer/IRS spectra. We have measured a heliocentric radial velocity of $+191.6\pm1.3\;kms^{-1}$ and expansion velocity 2Vexp of $40.5\pm3.3\;kms^{-1}$ from an average over 300 lines. The estimations of C, N, O, and Ne abundances from the optical recombination lines (ORLs) and Kr, Xe, and Ba from the collisional excitation lines (CELs) are also done. We have detected 5 fluorine and several slow neutron capture elements (the s-process). The amounts of [F/H], [Kr/H], and [Xe/H] suggest that BoBn 1 is the most F-rich among F detected PNe and is a heavy s-process element rich PN. The photo-ionization models built with non-LTE theoretical stellar atmospheres indicate that the progenitor was a 1-1.5 $M_\bigstar$ that would evolve into a white dwarf with an $0.62M_{\odot}$ core mass and $0.09M_{\odot}$ ionized nebula. Careful examination implies that BoBn 1 has evolved from a binary and experienced coalescence during the evolution to become a visible PN. The elemental abundances except N could be explained by a binary model composed of $0.75M_{\odot}+1.5M_{\odot}$ stars.

  • PDF

Facile Docking and Scoring Studies of Carborane Ligands with Estrogen Receptor

  • Ok, Kiwon;Jung, Yong Woo;Jee, Jun-Goo;Byun, Youngjoo
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.4
    • /
    • pp.1051-1054
    • /
    • 2013
  • Closo-carborane has been considered as an efficient boron-carrier for boron neutron capture therapy (BNCT) and an attractive surrogate of lipophilic phenyl or cyclohexyl ring in drug design. Despite a great number of carborane-containing ligands have been synthesized and evaluated, molecular modeling studies of carborane ligands with macromolecules have been rarely reported. We herein describe a facile docking and scoring-function strategy of 16 carborane ligands with an estrogen receptor by using the commercial Gaussian, Chem3D Pro and Discovery Studio (DS) computational programs. Docked poses of the carborane ligands in silico exhibited similar binding modes to that of the crystal ligand in the active site of estrogen receptor. Score analysis of the best docked pose for each ligand indicated that the Ligscore1 and the Dockscore have a moderate correlation with in vitro biological activity. This is the first report on the scoring-correlation studies of carborane ligands with macromolecules. The integrated Gaussian-DS approach has a potential application for virtual screening, De novo design, and optimization of carborane ligands in medicinal chemistry.