• Title/Summary/Keyword: Neutral-point potential

Search Result 59, Processing Time 0.025 seconds

Characteristics on the Neutral Point Potential of Line-to-Ground Voltage according to Line-to-Ground Fault in Resistance Ground System for Ships (선박의 저항접지 시스템에서 지락 고장에 따른 대지전압 중성점 전위 특성)

  • Lee, Yun-Hyung;Ryu, Ki-Tak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.689-696
    • /
    • 2018
  • System grounding is applied to the neutral point of a power source to secure the from any abnormal voltage and/or grounding fault. System grounding, which is applied mainly in ships is an ungrounded and resistance grounded system. Vessels using the MV power system with 3.3kV, 6.6kV, and 11kV mainly adopt a high resistance grounding system among the resistance grounding systems. The ground fault accounts for 95% of all faults occurring in the electrical system and when a fault occurs, the line-to-ground voltage of the power system is increased excessively, which adversely affects the onboard insulation system. This study analyzed the variation characteristics of the line-to-ground voltage neutral point according to the degree of ground fault in a resistance ground system applied in vessels. For this purpose, the characteristics of the grounding system were first explained, and the modeling of the neutral point potential of the line-to-ground voltage of the resistance grounding system in the vessels was derived. Finally, this study examined how the line-to-ground voltage, line voltage, and neutral point change according to various variable environments through MATLAB simulations.

A New Current Controlled PWM technique for NPC Inverter (NPC 인버터를 위한 새로운 전류제어 기법)

  • 이병송;김길동;변윤섭;한영재;박현주
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.63-69
    • /
    • 1998
  • A new current controlled PWM technique with NPC structure is proposed in this paper. A current controlled PWM technique with neutral-point-clamped pulse-width modulation inverter composed of main switching devices which operates as switch for PWM and auxiliary switching devices to clamp the output terminal potential to the neutral point potential is described. The proposed current controller has a first and second current band. The switching pattern will be made by the first current band. According to the second current band, the output state of the switching pattern is changed into positive and negative state. This inverter output contains less harmonic content and lower switching frequency than that of conventional current controlled PWM technique at the same current limit. Two inverters are compared analytically and the performance is investigated by the computer simulation.

  • PDF

New hysteresis current control for induction motor drive with NPC inverter (NPC 인버터에 의한 유도전동기 구동시스템의 새로운 히스테리시스 전류 제어기법)

  • 김춘삼;이병송
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.46-52
    • /
    • 1999
  • A new current controlled PWM t'||'&'||'pound;rlmique with NPC(Neutral Point Qarll)ed) structure is IrOIX>Sed in this paper. A current controlled PWM technique with neutral-JXlint-cIamped pulse-width modulation inverter composed of main switching devices which operates as switch for PWM and auxiliary switching devices to clamp the output terminal potential to the neutral point potential is described. The proposed current controller has a first and second current band The switching pattern will be made by the first current band. According to the second current band, the output state of the switching pattern is changed into positivee and negative state. This inverter output contains less hanronic content and lower switching frequency than that of conventional current controlled PWM technique at the same current limit. Thbe induction machine drive with proposed technique is investigated by commputer simulation.

  • PDF

New Strategy for Eliminating Zero-sequence Circulating Current between Parallel Operating Three-level NPC Voltage Source Inverters

  • Li, Kai;Dong, Zhenhua;Wang, Xiaodong;Peng, Chao;Deng, Fujin;Guerrero, Josep;Vasquez, Juan
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.70-80
    • /
    • 2018
  • A novel strategy based on a zero common mode voltage pulse-width modulation (ZCMV-PWM) technique and zero-sequence circulating current (ZSCC) feedback control is proposed in this study to eliminate ZSCCs between three-level neutral point clamped (NPC) voltage source inverters, with common AC and DC buses, that are operating in parallel. First, an equivalent model of ZSCC in a three-phase three-level NPC inverter paralleled system is developed. Second, on the basis of the analysis of the excitation source of ZSCCs, i.e., the difference in common mode voltages (CMVs) between paralleled inverters, the ZCMV-PWM method is presented to reduce CMVs, and a simple electric circuit is adopted to control ZSCCs and neutral point potential. Finally, simulation and experiment are conducted to illustrate effectiveness of the proposed strategy. Results show that ZSCCs between paralleled inverters can be eliminated effectively under steady and dynamic states. Moreover, the proposed strategy exhibits the advantage of not requiring carrier synchronization. It can be utilized in inverters with different types of filter.

Effects of Mg on corrosion resistance of Al galvanically coupled to Fe (Fe와 galvanic couple된 알루미늄의 내식성에 미치는 마그네슘의 영향)

  • Hyun, Youngmin;Kim, Heesan
    • Corrosion Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.40-49
    • /
    • 2013
  • Effects of magnesium and pH on corrosion of aluminum galvanically coupled to iron have studied by using potentio- dynamic and static tests for polarization curves, Mott-Schottky test for analysis of semiconductor property, and GD-AES and XPS for film analysis. Pitting potential was sensitive to magnesium as an alloying element but not to pH, while passive current was sensitive to pH but not to magnesium. It was explained with, instead of point defect model (PDM), surface charge model describing that the ingression of chloride depends on the state of surface charge and passive film at film/solution interface is affected by pH. In addition, galvanic current of aluminum electrically coupled to iron was not affected by magnesium in pH 8.4, 0.2M citrate solution but was increased by magnesium at the solution of pH 9.1. The galvanic current at pH 9.1 increased with time at the initial stage and after the exposure of about 200 minute, decreased and stabilized. The behavior of the galvanic current was related with the concentration of magnesium at the surface. It agreed with the depletion of magnesium at the oxide surface by using glow discharge atomic emission spectroscopy (GD-AES). In addition, pitting potential of pure aluminum was reduced in neutral pH solution where chloride ion maybe are competitively adsorbed on pure aluminum. It was confirmed by the exponential decrease of pitting potential with log of [$Cl^-$] around 0.025 M of [$Cl^-$] and linear decrease of the pitting potential. From the above results, unlike magnesium, alloying elements with higher electron negativity, lowering isoelectric point (ISE), are recommended to be added to improve pitting corrosion resistance of aluminum and its alloys in neutral solutions as well as their galvanic corrosion resistance in weakly basic solutions.

Investigations of Multi-Carrier Pulse Width Modulation Schemes for Diode Free Neutral Point Clamped Multilevel Inverters

  • Chokkalingam, Bharatiraja;Bhaskar, Mahajan Sagar;Padmanaban, Sanjeevikumar;Ramachandaramurthy, Vigna K.;Iqbal, Atif
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.702-713
    • /
    • 2019
  • Multilevel Inverters (MLIs) are widely used in medium voltage applications due to their various advantages. In addition, there are numerous types of MLIs for such applications. However, the diode-less 3-level (3L) T-type Neutral Point Clamped (NPC) MLI is the most advantageous due to its low conduction losses and high potential efficiency. The power circuit of a 3L T-type NPC is derived by the conventional two level inverter by a slight modification. In order to explore the MLI performance for various Pulse Width Modulation (PWM) schemes, this paper examines the operation of a 3L (five level line to line) T-type NPC MLI for various types of Multi-Carriers Pulse Width Modulation (MCPWM) schemes. These PWM schemes are compared in terms of their voltage profile, total harmonic distortion (THD) and conduction losses. In addition, a 3L T-type NPC MLI is also compared with the conventional NPC in terms of number of switches, clamping diodes, main diodes and capacitors. Moreover, the capacitor-balancing problem is also investigated using the Neutral Point Fluctuation (NPF) method with all of the MCPWM schemes. A 1kW 3L T-type NPC MLI is simulated in MATLAB/Simulink and implemented experimentally and its performance is tested with a 1HP induction motor. The results indicate that the 3L T-type NPC MLI has better performance than conventional NPC MLIs.

WATER VAPOR MASERS: A SIGNPOST FOR LOW MASS STAR FORMATION

  • Migenes, V.;Trinidad, M.A.;Valdettaro, R.;Brand, J.;Palla, F.
    • Journal of The Korean Astronomical Society
    • /
    • v.40 no.4
    • /
    • pp.127-129
    • /
    • 2007
  • It is well known that water vapor maser emission at 22.2 GHz is associated with the earliest stages of both low- and high-mass star formation and it can be considered a reliable diagnostic of their evolutionary state. Bright Rimmed Clouds (BRCs) are clouds that have been compressed by an external ionization-shock front which focuses the neutral gas into compact globules. The boundary layer between the neutral gas and the gas ionized by the incident photons is often called "bright rim" but the clumps are sometimes classified also as speck globules or cometary globules depending on their appearance. Small globules with bright rims have been considered to be potential sites of star formation and have been studied in several individual regions. We present results from high resolution VLA observations searching for new candidates of recent star formation in bright-rimmed clouds/globules associated with IRAS point sources.

A Study on Mobile Phone App. Design for Remote Alarm of Open-phase Fault (결상사고 원격 알람을 위한 모바일 폰 앱 개발에 관한 연구)

  • Jeong, Hoe-Joong;Kwak, Dong-Kurl;Lee, Hae-Keon;Song, Kang
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.270-272
    • /
    • 2018
  • This paper proposes an open-phase fault control system using 3-phase neutral voltage. The proposed control system is designed as a new topology which uses the potential difference between neutral point and ground(G) of three phase. And the open-phase detection system is configured to three resistance devices(Y-wiring) of the same capacity to each line of three phase power source R,S,T. This paper also designs a mobile phone application for remote alarm of open-phase fault.

  • PDF

A Study on Circuit Topology for the Electrical Power Failure and Open-Phase Fault Detection of Industrial Field (산업현장 정전 및 결상사고 감지회로 토폴로지 연구)

  • Park, Dong-Hun;Kwak, Dong-Kurl;Jeon, Hoe-Joong;Jeon, Ho-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.540-542
    • /
    • 2019
  • This paper proposes an open-phase fault control system using 3-phase neutral voltage. The proposed control system is designed as a new topology which uses the potential difference between neutral point and ground of three phase. The open-phase detection system is also configured to Y-wiring of three capacitance devices of the same capacity to each line of three phase power source R-S-T. This paper also designs a mobile phone application for remote alarm of open-phase fault.

  • PDF

A Study on Remote Alarm System of Open-phase Faults based on IoT (IoT 기반의 결상사고 원격알람 시스템에 관한 연구)

  • Jeong, Hoe-Joong;Kwak, Dong-Kurl;Choi, Shin-Hyeong;Kim, Choon-Sam;Yang, Ki-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.4-6
    • /
    • 2018
  • This paper proposes an open-phase fault control system using 3-phase neutral voltage. The proposed control system is designed as a new topology which uses the potential difference between neutral point and ground(G) of three phase. And the open-phase detection system is configured to Y-wiring of three capacitance devices of the same capacity to each line of three phase power source R-S-T. This paper also designs a mobile phone application for remote alarm of open-phase fault.

  • PDF