• 제목/요약/키워드: Neutral-point clamped

검색결과 156건 처리시간 0.028초

PEBB Based Bi-directional Rapid Charging System for EV Traction Battery

  • Kang, Taewon;Chae, Beomseok;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.323-324
    • /
    • 2013
  • This paper presents a simple and cost-effective stand-alone rapid battery charging system of 30kW for electric vehicles. The proposed system mainly consists of active front-end rectifier of neutral point clamped 3-level type and non-isolated bi-directional dc-dc converter of multi-phase interleaved half-bridge topology. The charging system is designed to operate for both lithium-polymer and lithium-ion batteries. The complete charging sequence is made up of three sub-interval operating modes; pre-charge mode, constant-current mode, and constant-voltage mode. The pre-charge mode employs the stair-case shaped current profile to accomplish shorter charging time while maintaining the reliable operation of the battery. The proposed system is specified to reach the full-charge state within less than 16min for the battery capacity of 8kWh by supplying the charging current of 78A. Owing to the simple and compact power conversion scheme, the proposed solution has superior module-friendly mechanical structure which is absolutely required to realize flexible power expansion capability in a very high-current rapid charging system.

  • PDF

부트스트랩 회로를 적용한 3-레벨 NPC 인버터의 저속 운전을 위한 PWM 스위칭 전략 (A PWM Control Strategy for Low-speed Operation of Three-level NPC Inverter based on Bootstrap Gate Drive Circuit)

  • 정준형;구현근;임원상;김욱;김장목
    • 전력전자학회논문지
    • /
    • 제19권4호
    • /
    • pp.376-382
    • /
    • 2014
  • This paper proposes the pulse width modulation (PWM) control strategy for low-speed operation in the three-level neutral-point-clamped (NPC) inverters based on the bootstrap gate drive circuit. As a purpose of the cost reduction, several papers have paid attention to the bootstrap circuit applied to the three-level NPC inverter. However, the bootstrap gate driver IC cannot generate the gate signal to the IGBT for low-speed operation, because the bootstrap capacitor voltage decreases under the threshold level. For low-speed operation, the dipolar and partial-dipolar modulations can be the effective solution. However, these modulations have drawbacks in terms of the switching loss and THD. Therefore, this paper proposes the PWM control strategy to operate the inverter at low-speed and to minimize the switching loss and harmonics. The experimental results are presented to verify the validity on the proposed method.

Minimization of Active Power and Torque Ripple for a Doubly Fed Induction Generator in Medium Voltage Wind Power Systems under Unbalanced Grid Conditions

  • Park, Yonggyun;Han, Daesu;Suh, Yongsug;Choi, Wooyoung
    • Journal of Power Electronics
    • /
    • 제13권6호
    • /
    • pp.1032-1041
    • /
    • 2013
  • This paper investigates control algorithms for a doubly fed induction generator with a back-to-back three-level neutral-point clamped voltage source converter in medium voltage wind power systems under unbalanced grid conditions. Three different control algorithms to compensate for unbalanced conditions have been investigated with respect to four performance factors; fault ride-through capability, instantaneous active power pulsation, harmonic distortions and torque pulsation. The control algorithm having a zero amplitude of torque ripple shows the most cost-effective performance concerning torque pulsation. The least active power pulsation is produced by the control algorithm that nullifies the oscillating component of the instantaneous stator active and reactive powers. A combination of these two control algorithms depending on the operating requirements and the depth of the grid unbalance presents the most optimized performance factors under generalized unbalanced operating conditions leading to high performance DFIG wind turbine systems.

3레벨 NPC 인버터의 전원전압변조 방식을 이용한 넓은 변조 지수에서 제어 가능한 간단한 중성점 제어 기법 (Simple Neutral Point Potential Control with Wide Modulation Indices Using Unified Voltage Modulation for Three-Level Diode-Clamped Inverter)

  • 문석환;박병건;김지원;김종무;이기창;하현욱;이정욱;박병우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.221-222
    • /
    • 2014
  • 본 논문에서는 3레벨 NPC 인버터의 전원전압변조 방식을 이용하여 넓은 변조 지수에서 제어 가능한 간단한 중성점 제어 방법을 제안하였다. 제안한 제어 방법은 전원 전압 변조방법을 이용한 중성점 균형 계수와 정확한 옵셋 전압의 제한치를 이용하여 계산된다. 중성점 균형 계수는 전류의 극성과 상하 커패시터의 전압에 의해서 정의되어 진다. 제안된 제어 방법은 중성점 제어를 위해 공간전압 PWM과 불연속 PWM까지 동작범위를 확장하여 동작되어 진다. 제안된 방법은 넓은 변조지수에서 전원전압변조를 이용하여 공간전압 PWM방법을 쉽게 구현할 수 있다. 제안된 중성점 제어 방법의 타당성은 시뮬레이션을 통하여 검증하였다.

  • PDF

Rapid Electric Vehicle Charging System with Enhanced V2G Performance

  • Kang, Taewon;Kim, Changwoo;Suh, Yongsug;Park, Hyeoncheol;Kang, Byungik;Kim, Simon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.201-202
    • /
    • 2012
  • This paper presents a simple and cost-effective stand-alone rapid battery charging system of 30kW for electric vehicles. The proposed system mainly consists of active front-end rectifier of neutral point clamped 3-level type and non-isolated bi-directional dc-dc converter of multi-phase interleaved half-bridge topology. The charging system is designed to operate for both lithium-polymer and lithium-ion batteries. The complete charging sequence is made up of three sub-interval operating modes; pre-charging mode, constant-current mode, and constant-voltage mode. Each mode is operated according to battery states: voltage, current and State of Charging (SOC). The proposed system is able to reach the full-charge state within less than 16min for the battery capacity of 8kWh by supplying the charging current of 67A. The optimal discharging algorithm for Vehicle to the Grid (V2G) operation has been adopted to maintain the discharging current of 1C. Owing to the simple and compact power conversion scheme, the proposed solution has superior module-friendly mechanical structure which is absolutely required to realize flexible power expansion capability in a very high-current rapid charging system. Experiment waveforms confirm the proposed functionality of the charging system.

  • PDF

PMSG 풍력발전기용 3L NPC와 ANPC 컨버터에서의 10kV IGCT 성능 비교 평가 (Comparative performance evaluation of 10kV IGCTs in 3L NPC and ANPC Converter in PMSG MV Wind Turbines)

  • 암리나라마;서용석;박병건;김지원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.86-88
    • /
    • 2018
  • The three level(3L) neutral point clamped (NPC) voltage source converter (VSC) topology is widely used for grid interface in high power wind energy due to its superior performance as compared to the two level(2L) VS. However, one of the major drawbacks of this topology is the unequal dispersion of loss and therefore the junction temperature among the power devices. The 3L ANPC topology derived from the NPC topology was proposed to resolve this drawback of unequal loss profile of 3L NPC. The 3L ANPC can work under various switching strategies. In this paper a comparative study of the various switching strategies of 3L ANPC using the recently developed 10kV IGCTs which has the capability to raise the current and voltage rating of the wind turbines is carried out. The comparison is performed using ABB make 10kV IGCT 5SHY17L9000 and PLECs simulations.

  • PDF

Hybrid PWM Modulation Technology Applied to Three-Level Topology-Based PMSMs

  • Chen, Yuanxi;Guo, Xinhua;Xue, Jiangyu;Chen, Yifeng
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.146-157
    • /
    • 2019
  • The inverter is an essential part of permanent magnet synchronous motor (PMSM) drive systems. The performance of an inverter is greatly influenced by its modulation strategy. Using a proper management of modulation strategies can guarantee high performance from a PMSM under various speed conditions. Switching between modulations is a pivotal technique that determines the performance of a PMSM. Most works on hybrid methods focus on two-level induction motors drive systems. In this paper, in order to improve the performance of PMSMs under various speed conditions, a hybrid method of a pulse width modulation (PWM) control scheme based on a neutral-point-clamped (NPC) three level topology was proposed. This hybrid PWM modulation comprised space vector PWM (SVPWM) and selective harmonic elimination PWM (SHEPWM). Under low speed conditions, the SVPWM is employed to cause the PMSM to start smoothly, and to obtain a rapid response from the control system. Under high speed conditions, the SHEPWM is employed to reduce the switching frequency and to eliminate particular current harmonics. Moreover, the harmonic characteristics of different modulations are analyzed to obtain a smooth transition between the SHEPWM and the SVPWM. Experimental and simulation results indicated the effectiveness of the proposed control method.

Vibroacoustic response of thin power law indexed functionally graded plates

  • Baij Nath Singh;Vinayak Ranjan;R.N. Hota
    • Steel and Composite Structures
    • /
    • 제50권3호
    • /
    • pp.299-318
    • /
    • 2024
  • The main objective of this paper is to compute the far-field acoustic radiation (sound radiation) of functionally graded plates (FGM) loaded by sinusoidally varying point load subjected to the arbitrary boundary condition is carried out. The governing differential equations for thin functionally graded plates (FGM) are derived using classical plate theory (CPT) and Rayleigh integral using the elemental radiator approach. Four cases, segregated on power-law index k=0,1,5,10, are studied. A novel approach is illustrated to compute sound fields of vibrating FGM plates using the physical neutral surface with an elemental radiator approach. The material properties of the FGM plate for all cases are calculated considering the power law indexes. An in-house MATLAB code is written to compute the natural frequencies, normal surface velocities, and sound radiation fields are analytically calculated using semi-analytical formulation. Ansys is used to validate the computed sound power level. The parametric effects of the power law index, modulus ratios, different constituent of FGM plates, boundary conditions, damping loss factor on the sound power level, and radiation efficiency is illustrated. This work is the benchmark approach that clearly explains how to calculate acoustic fields using a solid layered FGM model in ANSYS ACT. It shows that it is possible to asymptotically stabilize the structure by controlling the intermittent layers' stiffness. It is found that sound fields radiated by the elemental radiators approach in MATLAB, ANSYS and literatures are in good agreement. The main novelty of this research is that the FGM plate is analyzed in the low-frequency range, where the stiffness-controlled region governs the whole analysis. It is concluded that a clamped mono-ceramic FGM plate radiates a lesser sound power level and higher radiation efficiency than a mono-metallic or metal-rich FGM plate due to higher stiffness. It is found that change in damping loss factor does not affect the same constituents of FGM plates but has significant effects on the different constituents of FGM plates.

해상풍력단지에서의 PMSG 풍력발전기를 활용한 계통연계점 불평형 전원 보상 (Compensation of Unbalanced PCC Voltage in an Off-shore Wind Farm of PMSG Type Turbines)

  • 강자윤;한대수;서용석;정병창;김정중;박종형;최영준
    • 전력전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.1-10
    • /
    • 2015
  • This paper proposes a control algorithm for permanent magnet synchronous generators with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage off-shore wind power system under unbalanced grid conditions. Specifically, the proposed control algorithm compensates for unbalanced grid voltage at the PCC (Point of Common Coupling) in a collector bus of an off-shore wind power system. This control algorithm has been formulated based on symmetrical components in positive and negative synchronous rotating reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power is described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of AC input current is injected into the PCC in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm enables the provision of balanced voltage at the PCC resulting in the high quality generated power from off-shore wind power systems under unbalanced network conditions.

NPC와 H-Bridge 컨버더의 부스트 벡터와 커패시터 전압의 해석 (Analysis of Capacitor Voltage and Boost Vector in Neutral-Point-Clamped and H-Bridge Converter)

  • 김정균;김태진;강대욱;현동석
    • 전력전자학회논문지
    • /
    • 제8권3호
    • /
    • pp.274-284
    • /
    • 2003
  • 대용량 전력변환기기인 멀티-레벨 컨버터는 전동기구동시스템 및 유연송전시스템 등에 널리 사용되고 있다. 이중 H-Bridge 컨버터는 캐스캐이드 형태를 사용하여 멀티-레벨로의 확장이 용이한 장점으로 인해 shunt형 기기로 점차 응용이 확대되고 있다. 정상 상태에서 대략 0.7∼0.8의 변조지수 범위에서 작동한다. 고변조지수에서는 부스트 벡터인 zero vector가 인가되지 않아도 DC-link 전압은 일정하게 유지된다. 이것은 3-레벨 컨버터의 여러 벡터 중 zero vector 이외에도 또 다른 boost vector가 존재한다는 것을 의미한다. 본 논문은 boost vector의 원리를 살펴보고 3레벨 컨버터에서 zero vector와 또 다른 boost vector와의 차이점을 고찰하였다. 또한 본 논문은 두 토폴로지의 충전 전류와 커패시터 전압을 해석하고 비교한다 이 전압과 전류는 스위칭 상태와 기준전압과 관련되어 있고 이것을 이용하여 각 커패시터의 충전전류와 전압리플에 대한 계산 방법을 제안하였고 다양한 DC-Link 전압제어 방법을 시뮬레이션을 통해 비교하였다.