• 제목/요약/키워드: Neutral zone

검색결과 108건 처리시간 0.024초

무절연구간을 위한 열차위치검지방식 검토 (A review of the train position detection method for neutral section with energized condition)

  • 이태훈;이시빈;홍현표;이희순;박기범
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1100-1105
    • /
    • 2010
  • The high speed line and conventional line are a single-phase AC feeding system; and power supplies of different phases meet at SS(SubStation)s or SP(Sectioning Post)s. These sections should be negotiated with the main circuit breaker in the traction vehicle switched off, whereby the length of the neutral zone prevents the pantographs shunting adjacent overhead line section. In order for electric railway vehicles to make power running there, there must be a power supply changeover section (approx. for 1km), where a changeover switch changes a power supply to the other power supply of a train running direction sequentially. For a thorough changeover switching control, the precise train position detection is necessarily required. In this paper, to realize the ground-based train position detection method, configuration scheme of train position detection equipment is suggested by using track circuit and axle counter.

  • PDF

바닥면복사난방에서 Draft에 의한 쾌적열환경에 관한 연구 (A study on the comfort thermal environment by the Draft in floor panel heating system)

  • 이경희
    • 한국주거학회논문집
    • /
    • 제7권2호
    • /
    • pp.121-129
    • /
    • 1996
  • This study was to estimate how about various effects on the body thermal sensation as air velocity. clo. mean radiant temperature and resultant temperature are varied. The indoor thermal environment elements are measured under the five different of air velocity. Using the above considerations. the following results are obtained. ▶ The states, the air velocity under 0.5 m/s and 0.63 to 0.9 clo. were shown that the comfort zone of mean radiant temperature by 21.2~24.7C, the neutral point by 22.8C, the resultant temperature by 20.7-24.4C and the neutral point by 22.6C. ▶ On equal condition, the draft was occurred at a given air-velocity under 0.5m.s. It was also appeared the floor panel heating system affecting the body thermal sensation by the subject’s below-chest parts and the local discomfort by sensations on the feet and the knees.

  • PDF

모세관 전기영동 분석법의 복합약물제제의 품질관리 분석에 응용을 위한 연구 (Application of Capillary Electrophoresis for Quality Control Analysis of Complex Medicine)

  • 허유정;이공주
    • 약학회지
    • /
    • 제41권5호
    • /
    • pp.539-546
    • /
    • 1997
  • Capillary electrophoresis (CE) is perceived as an attractive tool for the analysis of pharmaceuticals and biological materials because of their high separation efficiency, easy separation and low running cost. New concept of micellar electrokinetic capillary chromatography (MECC) expanded the application of CE to the separation of neutral molecules. Validation of CE as an analytical technique for quality control of pharmaceuticals should be confirmed by quantitative analysis and the peak confirmation. In this study, the quantitative analyses of various types of neutral, acidic and basic components (acetaminophen, caffeine, ascorbic acid, riboflavin, thiamine, chlorpheniramine, phenylpropanolamine, dl-methylephedrine and dextromethorphan) in complex cold medicines have been accomplished using CE. Combined methods of MECC using SDS and capillary zone electrophoresis lowering the pH of running buffer were adopted to determine the ingredients in capsule type or liquid formula complex medicines without particular sample pretreatment. The results indicate that CE is a promising technique for quality control analysis of pharmaceuticals as a validation method.

  • PDF

교육기관의 정보시스템 보안관리 방안 연구 (A Study on Security Management Methods for Information System of Educational Institutions)

  • 최진명;김두연
    • 컴퓨터교육학회논문지
    • /
    • 제20권6호
    • /
    • pp.95-104
    • /
    • 2017
  • 교육기관 및 대학에서 사이버침해에 의하여 정보가 유출, 위조, 변조, 삭제 등 훼손되었을 때의 피해는 매우 크다. 본 연구에서 교육 관련 행정기관과 대학을 대상으로 사이버침해의 유형, 원인 및 문제점 등을 분석한 결과 관리적, 물리적, 기술적 정보보호 활동이 취약했다. 따라서 본 연구에서는 이들 취약점을 쉽게 식별하고, 보완 또는 보안성을 강화할 수 있도록 인터넷 영역, 네트워크 중립 영역(DMZ: Demilitarized Zone), 일반 서버 영역, 내부 서버 영역(Server Farm), 사용자 영역으로 구분하여 각 영역별로 보안강화 방안을 제시하였다. 또한, 행정기관 및 대학을 위한 보안성 높은 정보시스템 아키텍처와 정보보호 기술을 올바르게 적용할 수 있는 방법을 제시하였다. 본 연구는 개념적 지침이 아닌 구체적 활동과 절차 중심의 보안관리 방안을 제시한다는 데에 의의가 있다.

골격성 III급 무치악 환자에서 전치부 중립대를 고려한 총의치 제작 증례 (Complete denture fabrication of a skeletal class III edentulous patient considering anterior neutral zone: a case report)

  • 김수헌;김형준;박상원;임현필;박찬;장우형
    • 구강회복응용과학지
    • /
    • 제40권2호
    • /
    • pp.91-99
    • /
    • 2024
  • 골격성 3급 무치악 환자의 경우 총의치 제작 시 잔존치조제 관계를 고려하여 교차교합을 형성해 줌으로써 의치의 안정을 얻을 수 있다. 골격성 3급 악간관계에서 전치부를 정상교합 관계로 형성하는 것은 전방 캔틸레버를 가중시켜 의치의 안정을 저하시킬 수 있다. 하지만, 환자들은 총의치를 사용할 때 기능적인 면 뿐 아니라 심미적인 면 또한 중요시한다. 전치부 인공치들이 어떻게 배열되느냐에 따라 총의치의 심미성이 좌우되어, 골격성 3급 악간관계를 갖는 무치악 환자에서 정상교합이나 절단교합을 활용한 총의치 제작 증례가 보고되고 있다. 본 증례에서는 3급 악간관계를 갖는 무치악 환자에게 상악 전치부에 중립대를 고려하여 전치부 절단교합을 형성하여 의치를 제작하였고, 우수한 심미적, 기능적 결과를 얻었다.

여름철 내열성 증진을 위한 정량적 착의훈련의 효과 (제1보) -20대 여성의 적정착의 온도 설정: 의복내 온도를 중심으로- (A Study on Quantitative Wear Training for the Improvement of Heat Tolerance in Summer (Part I) -20's Females' Optimal Wearing: Focus on Inside Clothing Temperatures in Pre-summer-)

  • 이효현;최정화
    • 한국의류학회지
    • /
    • 제36권3호
    • /
    • pp.259-268
    • /
    • 2012
  • This study suggests quantitative guidelines for inside clothing temperatures to improve the heat tolerance of 20's females in summer. First, the inside clothing temperatures ($T_{cl}$) of each subject was measured in daily use. The subjects were asked to record subjective thermal sensations, clothing items worn, clothing weight, and activities during an experiment designed to determine the comfort zone of $T_{cl}$. In a thermally neutral state, the comfort zone of $T_{cl}$ was decided on a mean value $T_{cl}{\pm}1{\sigma}$. Second, the subjects were asked to wear clothing that would enable them to feel 'slightly warm but still comfortable'. The rest of the processes were the same as previous steps that were designed to understand the way and degree of clothing control. The comfort zone of $T_{cl}$ was decided in the same manner as the previous step. The two comfort zones were combined and named the combined comfort zone of the definitive comfort zone. The results were as follows: 1. Thermally comfortable $T_{cl}$, Hcl were $34.0{\pm}1.1^{\circ}C$, $40{\pm}9%%RH$ and the thermally comfortable ambient climate was $25.0{\pm}1.6^{\circ}C$, $53{\pm}7%$RH. 2. When subjects were asked to wear 'slightly warm but still comfortable', there were difference in thermally comfortable $T_{cl}$, clothing weight and clothing layer by subject. 3. In this study, the optimal $T_{cl}$ was decided on the mid-point of the definitive comfort zone of $T_{cl}$.

조질압연에서의 연신율제어를 위한 set-up 모델 개발 (Development of Set-up Model for Elongation Control in Steel Skin Pass Mill)

  • 이원호
    • 소성∙가공
    • /
    • 제10권2호
    • /
    • pp.130-136
    • /
    • 2001
  • The mathematical set-up model was developed to reduce the mechanical property deviation in annealed and slightly rolled steel strip. The mechanical peculiarities of skin pass rolling process, such as high friction value and non-circular contact arc, low reduction and non-negligible entry and exit elastic zones as well as central restricted deformation zone are all taken into account. The deformation of work rolls is calculated with the influence function method and arbitrary contact arc shape is permitted. The strip deformation is modeled by slab method and the entry and exit elastic deformation zones are included. The strip restricted deformation zone near the neutral point is also considered. It was revealed that the new model has better accuracy than present regression model by statistical analysis with actual mill rolling data.

  • PDF

A Study on the Suggestion of Thermal Comfort Range in Radiant Floor Ondol Heating System

  • Chung, Kwang-Seop
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권2호
    • /
    • pp.108-112
    • /
    • 2004
  • The purpose of this study is to investigate the characteristics of thermal comfort index and to present the thermal comfort range through regression analyses and experiment in a radiant floor heating system laboratory. The results were compared to the comfort zone of ISO-7730, and the applicability of the thermal comfort index to a radiant floor heating system was studied. On comparing the sedentary posture on the floor to sitting on the chair, the comfort zone and the neutral point of comfort index showed different values. It is considered that the influence of conduction from floor to the human is sufficient. Moreover, we could find a correlation between the thermal sensation votes of subjects, and the comfort indexes were lower than those by calculation.

Theoretical analysis of stress-strain behavior of multi-layer RC beams under flexure

  • Ertekin Oztekin
    • Structural Engineering and Mechanics
    • /
    • 제90권5호
    • /
    • pp.505-515
    • /
    • 2024
  • In this study, obtaining theoretical stress-strain curves and determining the parameters defining the equivalent rectangular stress block were aimed for 3 and 4-layered rectangular Reinforced Concrete (RC) cross-sections subjected to flexure. For these aims, the analytical stress-strain model proposed by Hognestad was chosen for the concrete grades (20 MPa≤fck≤60 MPa) used in this study. The tensile strength of the concrete was neglected and the thickness of the concrete layers in the compression zone of the concrete cross-section was taken as equal. In addition, while concrete strength was kept constant within each layer, concrete strengths belonging to separate layers were increased from the neutral axis towards the outer face of the compression zone of the concrete cross-section. After the equivalent rectangular stress block parameters were determined by numerical iterations, variations of these parameters depending on concrete strength in layers and layer numbers were obtained. Finally, some analytical equations have been proposed to predict the equivalent stress block parameters for the 3 and 4-layered RC cross-sections and validities of these proposed equations were shown by different metrics in this study.

철근 콘크리트 부재의 부착거동에 관한 실험적 연구 (An Experimental Investigation on the Bond Characteristics of Reinforced Concrete Structure)

  • 오병환;이성로;방기성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1990년도 봄 학술발표회 논문집
    • /
    • pp.122-127
    • /
    • 1990
  • The transfer of forces across the interface by bond between concrete and steel is of fundamental importance to many aspects of reinforced concrete behavior. Bond stress - slip relationships were studied using a symmetrical tension test specimen. This type of test is intented to simulate conditions in the tension zone of a concrete beam between primary cracks and below the neutral axis. These relationships between local bond stress and local slip are quite different at different locations along the bar. The present study allows more accurate analysis of reinforced concrete structures by employing more realistic bond stress-slip relations.

  • PDF