• Title/Summary/Keyword: Neutral type

Search Result 611, Processing Time 0.032 seconds

BOUNDED OSCILLATION OF SECOND ORDER UNSTABLE NEUTRAL TYPE DIFFERENCE EQUATIONS

  • Thandapani, E.;Arul, R.;Raja, P.S.
    • Journal of applied mathematics & informatics
    • /
    • v.16 no.1_2
    • /
    • pp.79-90
    • /
    • 2004
  • In this paper the authors present sufficient conditions for all bounded solutions of the second order neutral difference equation ${\Delta}^2(y_n\;-\;py_{n-{\kappa}})\;-\;q_nf(y_{n-e})\;=\;0,\;n\;{\in}\;N$ to be oscillatory. Examples are provided to illustrate the results.

A Study on the Parameters Influence upon Automotive Neutral Gear Rattle (자동차 공회전시 기어 치타음에 영향을 미치는 파라미터에 관한 연구)

  • Hong, D.P.;Chung, T.J.;Ahn, B.M.;Jeon, B.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.2
    • /
    • pp.74-83
    • /
    • 1997
  • The non-periodic angular accelerations of engine are the major cause of gear rattle. This gear rattle is based on the existence of a backlash between the drive gear of input shaft and the free gear of output shaft in the gearbox. Especially, the neutral gear rattle have a very bad effect on the ride quality. Test-rig was constructed in order to evaluate the parameter influence upon the neutral gear rattle. Also, each different 4 type torsional characteristic of clutch was manufactured. Experimental conditions are the use of each different 4 type torsional characteristic of clutch and oil temperature variation in gearbox. In case of the same stiffiness of pre-damper type clutch at idling, the clutch of large hysteresis showed dam- ping effects at the 2nd input gear and the 2nd output gear. Also, the main-damper type clutch was shown to large resonance phenomenon at the 2nd input gear. Accordingly, main-damper type clutch was unapp- roriate at idling.

  • PDF

Research on the Mechanism of Neutral-point Voltage Fluctuation and Capacitor Voltage Balancing Control Strategy of Three-phase Three-level T-type Inverter

  • Yan, Gangui;Duan, Shuangming;Zhao, Shujian;Li, Gen;Wu, Wei;Li, Hongbo
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2227-2236
    • /
    • 2017
  • In order to solve the neutral-point voltage fluctuation problem of three-phase three-level T-type inverters (TPTLTIs), the unbalance characteristics of capacitor voltages under different switching states and the mechanism of neutral-point voltage fluctuation are revealed. Based on the mathematical model of a TPTLTI, a feed-forward voltage balancing control strategy of DC-link capacitor voltages error is proposed. The strategy generates a DC bias voltage using a capacitor voltage loop with a proportional integral (PI) controller. The proposed strategy can suppress the neutral-point voltage fluctuation effectively and improve the quality of output currents. The correctness of the theoretical analysis is verified through simulations. An experimental prototype of a TPTLTI based on Digital Signal Processor (DSP) is built. The feasibility and effectiveness of the proposed strategy is verified through experiment. The results from simulations and experiment match very well.

Current Limiting Characteristics of transformer type SFCL using neutral line (중성점을 이용한 변압기형 초전도 한류기의 전류제한 특성 분석)

  • Cho, Yong-Sun;Choi, Hyo-Sang;Park, Hyoung-Min;Lee, Ju-Hyoung;Jung, Byung-Ik
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2090-2091
    • /
    • 2007
  • We investigated the characteristics of transformer type SFCL with neutral line. The transformer type SFCL having neutral line has achieved the simultaneous quench because the secondary winding has acted as parallel reactor. The fault current of SFCL was limited according to ratio of turn number between primary and secondary windings. Therefore, the power burden of superconducting element can be reduced by reduction of ratio of turn number between primary and secondary windings. As a result, we could expect reduction of it's volume in the transformer type SFCL.

  • PDF

Fuzzy Controller for Intelligent Networked Control System with Neutral Type of Time-delay (뉴트럴 타입 시간 지연을 갖는 지능형 네트워크 제어 시스템의 퍼지 제어기 설계)

  • Joo, Young-Hoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.2
    • /
    • pp.174-179
    • /
    • 2009
  • We consider the stabilization problem for a class of networked control systems with neutral type of time delays. The neutral type of time-delays occur in controller-to-actuator and sensor-to-controller. The Takagi-Sugeno (T-S) fuzzy model is employed to represent a nonlinear system with neutral type of time-delays. The stabilization via state-feedback is first addressed, and delay-range-dependent stabilization conditions are proposed in terms of linear matrix inequalities (LMIs). Finally, an application example will be given to show the merits and design a procedure of the proposed approach.

Analysis on the Improvement of Power Capacity Increase in the Transformer-Type SFCL with Neutral Lines (중성선을 갖는 변압기형 초전도 한류기의 용량증대 개선 연구)

  • Cho, Yong-Sun;Choi, Hyo-Sang;Kim, Deog-Goo;Go, Sung-Pil
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1438-1443
    • /
    • 2011
  • The increase of power capacity in the superconducting fault current limiter (SFCL) is essential for application into the power grid. To achieve this, when superconducting units were connected in series and parallel, the unbalanced quenching characteristics between superconducting units generated by different critical current behavior should be improved. In the transformer-type SFCL, the superconducting units connected in series could be simultaneously quenched by the connection of neutral lines between secondary coils and superconducting units. From this the consumed power in superconducting units was equally distributed. In addition, the more the turn ratio of the transformer was reduced, the more consumed power in the superconducting units was reduced by the decrease of the induction voltage generated in the superconducting units. From those results, the transformer-type SFCL using neutral lines could increase the power capacity of the SFCL by the equal power division into the superconducting units.

A study on neutral section device adopted in the catenary system with maximum speed of 200km/h (최대 200km/h로 속도 향상된 Catenary system에 적용한 절연구분장치)

  • Ahn Young-Hoon;Gang Chang-Ho
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.541-546
    • /
    • 2003
  • The study is about a neutral section device adopted in the catenary system in connection with KNR's project to electrify the conventional Honam-Line. A neutral section device(PTFE type) adopting into catenary system accepts a train velocity of 200km/h, installed firstly in Korea electric. railway system. This study shows technologies and construction cases of the neutral section device.

  • PDF

Sampled-data Fuzzy Control for Nonlinear Neutral Systems (샘플치 퍼지 제어기 설계를 이용한 비선형 뉴트럴 시스템 제어기 설계)

  • Song, Min-Kook;Joo, Young-Hoon;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.195-196
    • /
    • 2008
  • This paper presents the stability analysis and design for a sampled-data fuzzy control system with neutral type of time delay. The sampling activity and neutral type of time delay will complicate the nonlinear system dynamics. And it make the stability analysis much more difficult than that for a continuous-time fuzzy control system. Based on the fuzzy control approach, linear matrix inequality (LMI)-based stability conditions are derived to guarantee the neutral T-S fuzzy system stability. Finally, an example is provided to illustrate the effectiveness of the proposed approach.

  • PDF

Research on Carried-Based PWM with Zero-Sequence Component Injection for Vienna Type Rectifiers

  • Ma, Hui;Feng, Mao;Tian, Yu;Chen, Xi
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.560-568
    • /
    • 2019
  • This paper studies the inherent relationship between currents and zero-sequence components. Then a precise algorithm is proposed to calculate the injected zero-sequence component to control the DC-Link neutral-point voltage balance, which can result in a more efficient and flexible neutral point voltage balance with a desirable performance. In addition, it is shown that carried-based PWM with the calculated zero-sequence component scheme can be equivalent to space-vector pulse-width modulation (SVPWM). Based on the proposed method, the optimal zero-sequence component of the feasible modulation indices is analyzed. In addition, the unbalanced load limitation of the DC-Link neutral-point voltage balance control is also revealed. Simulation and experimental results are shown to verify the validity and practicality of the proposed algorithm.

Comparative Study on the Salivary Gland between Two Species (Achatina fulica and Incilaria fruhstorferi) of the Snails in Stylommatophora ( Mollusca, Gastropoda ) (병안목 달팽이류 두 종간 (Achatina fulica and Incilaria fruhstorferi)의 타액선에 관한 비교 연구)

  • 한종민;장남섭
    • The Korean Journal of Malacology
    • /
    • v.12 no.2
    • /
    • pp.109-121
    • /
    • 1996
  • Histochemical experiment was carry out respectively to confirm the properties of the salis (Achatina fulica and Incilaria fruhstorferi). SDS-PAGE was carried out to compare and invertigate the distribution aspects of protein patterns between the two species. Five types(A, B, F, H and I)of gland cells with four neutral mucopolysaccharide cells and one acid mucopolysaccharide cells and one acid mucopolysaccharide cell were observed in acinous of Achatina fulica, while six types were observed in acinous of Incilaria fruhstorferi: ond acid mucopolysaccharide cell(type-A) and four neutral mucopolysaccharide cells(type-B, C, D and F) and one cell that acid mucopolysaccharide is only mimbrane that surrounded granule(type-E). The results are follows:The thpe-A fland cell is commonly observed between the two species. The type-A gland cell in Achatina fulica possesses a nucleus with a developed heterdchromatin, and the cytoplasm was filled with round granules. The granules were surrounded with an uncertain boundary mimbrane and confirmed with neutral mucopolysaccharides, but is confirmed acid mucopolysaccharide in Incilaria fruhstorferi.The type-B gland cell is obwerved in the two species, too. The type-B gland cell in Achatina fulica was round shaped, and included an evenly alrge nucleus. The uncleoplasm included granules that were confirmed in the neutral mucopolysaccharides of the two species. The type-C and D gland cells exist only in Incilaria fruhstorferi, nucleoplasm was well developed heterochromatins. The type-E gland cell appears in the acinous surrounded the salivary gland of Incilaria fruhstorferi. Thdse granules appear irregular irregular shape and size and the cytoplasm is formed in alveolar. The type-F gland cells are commonly observed in the salivary glands of the two species. They are similar with the type-B gland cell, but the granular shape is comparatively small and irregular, and possess the neutral mucos granules. The type-H gland cells are mainly seen in only Achatina, and in nucleus is a well developed heterochromatin. The cytoplasm is filled with round small granules with acid mucopolysaccharide for alcianophilia observed. The type-I cell was small cell with an irregular shape and only observed in the gland cells of Achatina fulica. The heterochromatins were developed in the nucleus and the granules are not observed in cytoplasm.Secretory ducts of saliva are composed of the interlobular duct and interlobar secretory duct. In Achatina fulica the interlobular duct consists of a simple cuboidal epithelium, while the endothelium of intralobar secretory duct of Incilaria fruhstorferi consists of a simple squamous epithelium and in the cytoplasm is filled with granules(type-G secretory cell). A SDS-PAGE was carried out to confirm that the protein band pattern consist of salivary gland. In conclusions, five more bands in Achatina fulica and three bands in Incilaria fruhstorferi were confirmed in MW<29 kDa. one main band coincides comparatively with both and is between 29-45 kDa. There are four main bands in Achatina fulica and two main bands in Incilaria fruhstorferi between 45-66.5 kDa respectively. The bands in Achatina fulica seem more complex than in incilaria fruhstorferi.

  • PDF