• Title/Summary/Keyword: Neutral Current

Search Result 485, Processing Time 0.029 seconds

Compensation of Unbalanced PCC Voltage in Off-shore Wind Farms of PMSG Type Turbine

  • Kang, Jayoon;Han, Daesu;Suh, Yongsug;Jung, Byoungchang;Kim, Jeongjoong;Park, Jonghyung;Choi, Youngjoon
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.215-216
    • /
    • 2014
  • This paper proposes a control algorithm for permanent magnet synchronous generator with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage offshore wind power system under unbalanced grid conditions. The proposed control algorithm particularly compensates for the unbalanced grid voltage at the point of common coupling in a collector bus of offshore wind power system. This control algorithm has been formulated based on the symmetrical components in positive and negative rotating synchronous reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power are described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of ac input current is injected to the point of common coupling in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm makes it possible to provide a balanced voltage at the point of common coupling resulting in the generated power of high quality from offshore wind power system under unbalanced network conditions.

  • PDF

A Study on the Characteristics of Panels and the Correlations between Partisanships of Political Parties and Talks of Panels in Public Affair Talk Programs of General Programming Channels (종합편성채널 시사대담 프로그램의 출연 패널 특성 및 패널 발언과 정당 입장간의 상관성에 관한 연구)

  • Son, Hwasung;Lee, Yeong-Ju
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.5
    • /
    • pp.658-668
    • /
    • 2019
  • The political influences of general programming channels have grown with the help of the current affairs talk programs for years but also these channels have been criticized as politically biased media. This study investigates the characteristics of the panels who had appeared for 6 months since July of 2017 and examines the relationship between the panels' talk and the position of political parties. The results show that jobs of the casting panels were introduced as neutral ones which are not related to politics. However, after reclassifying them in terms of their political careers, most panels were more likely to be involved in political parties. In addition, they tend to support the positions of the ruling or opposition parties. The more the association with the political party, the stronger the panel's comments. The partisanship of the panels should be clearly presented in the broadcasting programs. It is necessary to distinguish genres of current affair programs by consistent standards to ensure consistency of deliberation. Lastly self-regulation of program producers should be more strengthened.

Algorithm for Switch Open Fault Detection of Asymmetric 6-phase PMSM Based on Stationary Reference Frame dq-axis Currents (비대칭 6상 영구자석 동기 전동기의 정지 좌표계 DQ축 전류를 이용한 스위치 개방 고장 검출 기법)

  • Lee, Won-Seok;Kim, Han-Eol;Hwang, Seon-Hwan;Lee, Ki-Chang;Park, Jong-Won
    • Journal of IKEEE
    • /
    • v.26 no.2
    • /
    • pp.265-270
    • /
    • 2022
  • This paper proposes the detection algorithm for switch open fault of asymmetric 6-phase PMSM based on stationary reference frame dq-axis currents. In this paper, target motor has an asymmetric structure in which two upper three windings have an electrical phase difference of 30° and a neutral point is separated. As a result, dual 3-phase PWM inverters and the detection techniques due to open failures of switch are definitely required. In this paper, the dual dq-axis current control method is used for driving the asymmetric 6-phase PMSM and the open fault switch should be detected by using variable all pass filter and low pass filter in order to detect the current amplitude. The effectiveness and usefulness of the proposed method is verified by several experiments.

Fabry disease: current treatment and future perspective

  • Han-Wook Yoo
    • Journal of Genetic Medicine
    • /
    • v.20 no.1
    • /
    • pp.6-14
    • /
    • 2023
  • Fabry disease (FD), a rare X-linked lysosomal storage disorder, is caused by mutations in the α-galactosidase A gene gene encoding α-galactosidase A (α-Gal A). The functional deficiency of α-Gal A results in progressive accumulation of neutral glycosphingolipids, causing multi-organ damages including cardiac, renal, cerebrovascular systems. The current treatment is comprised of enzyme replacement therapy (ERT), oral pharmacological chaperone therapy and adjunctive supportive therapy. ERT has been introduced 20 years ago, changing the outcome of FD patients with proven effectiveness. However, FD patients have many unmet needs. ERT needs a life-long intravenous therapy, inefficient bio-distribution, and generation of anti-drug antibodies. Migalastat, a pharmacological chaperone, augmenting α-Gal A enzyme activity only in patients with mutations amenable to the therapy, is now available for clinical practice. Furthermore, these therapies should be initiated before the organ damage becomes irreversible. Development of novel drugs aim at improving the clinical effectiveness and convenience of therapy. Clinical trial of next generation ERT is underway. Polyethylene glycolylated enzyme has a longer half-life and potentially reduced antigenicity, compared with standard preparations with longer dosing interval. Moss-derived enzyme has a higher affinity for mannose receptors, and seems to have more efficient access to podocytes of kidney which is relatively resistant to reach by conventional ERT. Substrate reduction therapy is currently under clinical trial. Gene therapy has now been started in several clinical trials using in vivo and ex vivo technologies. Early results are emerging. Other strategic approaches at preclinical research level are stem cell-based therapy with genome editing and systemic mRNA therapy.

Problems and solution for the circulation current at the neutral line in the 22.9kV CNCV cable distribution system. (전력기술.정보-22.9kV 배전계통 CNCV 케이블 동심중성선에 발생하는 순환전류 문제점 및 대책)

  • 전명수
    • Electric Engineers Magazine
    • /
    • s.304
    • /
    • pp.22-25
    • /
    • 2007
  • 우리 나라의 전력 계통에 있어 22.9kV-y 배전 방식은 변전소로부터 배전 선로를 통해 대도시 중심부 등 사람의 왕래가 빈번한 곳이나 신도시 지역 등에 지중 케이블로 전력을 공급하고 있으며 선로 운영상 배전 선로의 중성선을 일정 구간 마다 3선 일괄 접지하는 다중 접지방식을 채택하고 있다. 이러한 다중 접지방식은 동심 중성선을 대지에 직접 접지하기 때문에 지락 사고시 건전상의 전압 상승이 적어 전력 설비의 절연 및 지락 전류의 검출이 용이하고 보호 계전기 등이 신속하게 동작한다. 계통 사고 등으로 인하여 동심 중성선의 전위가 상승되는 것을 방지하고자 케이블 접속 구간마다 동심 중성선을 일괄 접지하는 방식으로 배전 계통을 운영하고 있다. 이는 지락 사고시에는 동심 중성선의 대지 전위 상승을 일정값 이하로 제한하여 안전하게 유지하기 위해서이다. 그러나 지중 배전 선로에서 각 상(A, B, C상)의 부하가 불평형이 되는 것은 물론 평형일 경우에도 동심 중성선에는 부하 전류에 41.5%(전력구)-51.6%(관로)의 동심 중성선 순환 전류가발생되고 있기 때문에 순환전류로 인한 손실이 도체 손실의 76%에 달하며, 이러한 손실 전력으로 케이블의 내부 온도가 상승되어 케이블의 전류 용량이 관로의 경우 20% 정도 감소하게 된다. 본 연구는 이같은 문제점을 해결하는데 목적이 있다.

  • PDF

Causal Effects on Attitude toward Retirement and the Level of Retirement Planning (은퇴태도와 은퇴계획수준의 인과관계에 관한 연구)

  • Hong, Sung-Hee;Kwak, In-Sook
    • Journal of Families and Better Life
    • /
    • v.25 no.2 s.86
    • /
    • pp.89-104
    • /
    • 2007
  • The purpose of this study was to analyze the affecting factors on male salary workers' level of retirement planning. The focus was on the causal effects on salary workers' attitude toward retirement and their level of retirement planning. The major findings were as follows.: First, the salary worker's attitude toward retirement was neutral, neither positive nor negative, and they estimated their level of retirement planning relatively high. Second, the major factors affecting on attitude toward retirement were salary workers' age, their current economic status, and future perspectives for the post-retirement life. Third, the major affecting factors on level of retirement planning were salary workers' age, health status, and level of self-esteem, household net asset, savings and investment for elderly life, and attitude toward retirement. forth, the causal effects on the level of retirement planning was verified, and attitude toward retirement had direct effect as well as indirect effect on the level of retirement planning. From the findings, it can be concluded that the salary workers' attitude toward retirement played a important role in the process of retirement planning.

STRUCTURE OF THE PHOTOSPHERIC VECTOR MAGNETIC FIELDS (태양광구의 벡터 자기장 구조)

  • Jo, Gyeong-Seok;Kim, Gap-Seong
    • Publications of The Korean Astronomical Society
    • /
    • v.10 no.1
    • /
    • pp.91-108
    • /
    • 1995
  • We have intensively examined the structure of photospheric magnetic fields obtained from the calculation of the polarized radiation transfer for the model atmosphere. To determine more reliable magnetic field in the photospheric region composed of umbra, penumbra and quite area, we have calculated the polarized radiative transfer for a magnetically sensitive spectral line, FeI $6302.5{\AA}$, using our composite model representing three kinds of the atmospheric area distinguished by the pixel value of the Stokes I image over the region. Polarization data of the full Stokes parameters, used in this paper had been obtained from the vector magnetograph on Solar Flare Telescope of National Astronomical Observatory at Mitaka(MTK) in Japan. According to our investigation on the active region in the photosphere, it has been found that the large current density(${\geq}8{\times}10^2A/km^2$) and shear angle(${\geq}85^{\circ}$) should be distributed along the magnetic neutral line. To be compared with the results of MTK, our results in transverse magnetic field strength and direction are similar with those of MTK, however our longitudinal field strength at the center of the spot is somewhat(${\sim}1000$ Gauss) larger than MTK.

  • PDF

Eco-design Color Trends in Fashion (패션에 나타난 에코디자인의 색채경향 연구)

  • Song, Jee-Eun;Choi, Kyung-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.3
    • /
    • pp.492-507
    • /
    • 2010
  • The eco-design in modem fashion is mixed with a well-being trend that combines functionality and ethics with technology to suggest a new fashion style for the $21^{st}$ century. This study analyzes the colors of the eco-design in the current fashion trends and identifies the eco-friendly color images that suggest directions for eco-design. The results of this study are as follows. First, the eco-design is an ethical design concept of the ecological value. It can be classified into the functional efficiency in the multi-functionality the sustainability, the recycling capability, the trends for health and craftsmanship, according to various suggestions by eco-design related theorists. Second, the eco-colors shown in the fashion trend follow the order of YR, R, Y, N, and B, with the order of the pale, grayish, light grayish and dull tones. Third, the hue trends of eco-colors each eco-type are focused on R, YR, and Y. With regards to the tones, the functional efficiency, the multi-functional capability, and the sustainability are shown in the neutral tone, while the recycling capability is shown in the grayish tone and the trends pursuing health and craftsmanship are shown in the pale tone.

Chemical Stabilization Study for Sulfonylurea Herbicides (Sulfonylurea계(系) 제초제(除草劑)의 화학적(化學的) 안정성(安定性))

  • Chen, Chia-Chung
    • Korean Journal of Weed Science
    • /
    • v.17 no.2
    • /
    • pp.135-138
    • /
    • 1997
  • Sulfonylureas are highly active herbicides which can be applied at very low rate(10-50g/ha) to control broadleaf weeds. The nature of this category of compound is, however, very unstable toward hydrolysis. Therefore, the preparation of these compounds as liquid formulation was not possible. Most of the current formulations of sulfonylurea are in dry forms such as water dispersible granule or wettable powder. Even in these dry forms, the active ingredients also encounter significant chemical decomposition. This study involves the preparation of the sulfonylurea salts by reacting the parent compound with base such as sodium hydroxide. The salt becomes stable toward hydrolysis and it turns soluble when diluted with water. This discovery makes the preparation for liquid formulation or soluble granule of sulfonylurea possible. The stoichiometry of base added to the neutral sulfonylurea is controlled quite precisely. The base has to be added enough to quench the acidic impurities in the technical material and to convert the active ingredient into salt. However, the base should not be overused to cause further saponification of the sulfonylurea salts. The chemical nature of these compounds is presented and the chemical reaction is described. New soluble liquid formulation and solid granule formulation of sulfonylurea are suggested.

  • PDF

Voltage Unbalance Factor for Phase and Line Voltage (상전압 및 선간전압에 대한 불평형율)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Dong-Ju;Lee, Jong-Han;Lee, Eun-Wong;Park, Jong-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.74-77
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, voltage unbalance is generated at the user's 3-phase 4-wire distribution systems with single & three phase. Voltage unbalance is mainly affected by load system rather than power system. Unbalanced voltage will draws a highly unbalanced current and results in the temperature rise and the low output characteristics at the machine. It is necessary to analyse correct voltage unbalance factor for reduction of side effects in the industrial sites. Voltage unbalance is usually defined by the maximum percent deviation of voltages from their average value, by the method of symmetrical components or by the expression in a more user-friendly form which requires only the three line voltage readings. If the neutral point is moved at the 3-phase 4-wire system by the unbalanced load, by the conventional analytical method, line and phase voltage unbalance leads to different results due to zero-sequence component. This paper presents a new analytical method for phase and line voltage unbalance factor in 4-wire systems. Two methods indicate exact results.

  • PDF