• Title/Summary/Keyword: Neurosurgery

Search Result 4,194, Processing Time 0.034 seconds

Monte Carlo Simulation of the Carbon Beam Nozzle for the Biomedical Research Facility in RAON (한국형 중이온 가속기 RAON의 의생물 연구시설 탄소 빔 노즐에 대한 Monte Carlo 시뮬레이션)

  • Bae, Jae-Beom;Cho, Byung-Cheol;Kwak, Jung-Won;Park, Woo-Yoon;Lim, Young-Kyung;Chung, Hyun-Tai
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.12-17
    • /
    • 2015
  • The purpose of the Monte Carlo simulation study was to provide the optimized nozzle design to satisfy the beam conditions for biomedical researches in the Korean heavy-ion accelerator, RAON. The nozzle design was required to produce $C^{12}$ beam satisfying the three conditions; the maximum field size, the dose uniformity and the beam contamination. We employed the GEANT4 toolkit in Monte Carlo simulation to optimize the nozzle design. The beams for biomedical researches were required that the maximum field size should be more than $15{\times}15cm^2$, the dose uniformity was to be less than 3% and the level of beam contamination due to the scattered radiation from collimation systems was less than 5% of total dose. For the field size, we optimized the tilting angle of the circularly rotating beam controlled by a pair of dipole magnets at the most upstream of the user beam line unit and the thickness of the scatter plate located downstream of the dipole magnets. The values of beam scanning angle and the thickness of the scatter plate could be successfully optimized to be $0.5^{\circ}$ and 0.05 cm via this Monte Carlo simulation analysis. For the dose uniformity and the beam contamination, we introduced the new beam configuration technique by the combination of scanning and static beams. With the combination of a central static beam and a circularly rotating beam with the tilting angle of $0.5^{\circ}$ to beam axis, the dose uniformity could be established to be 1.1% in $15{\times}15cm^2$ sized maximum field. For the beam contamination, it was determined by the ratio of the absorbed doses delivered by $C^{12}$ ion and other particles. The level of the beam contamination could be achieved to be less than 2.5% of total dose in the region from 5 cm to 17 cm water equivalent depth in the combined beam configuration. Based on the results, we could establish the optimized nozzle design satisfying the beam conditions which were required for biomedical researches.

3-Dimensional Verification Technique for Target Point Error (자기공명영상기반 겔 선량측정법을 이용한 3차원적 목표 중심점 점검기술)

  • Lee, Kyung-Nam;Lee, Dong-Joon;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.35-41
    • /
    • 2011
  • For overall system test, hidden-target test have been used using film which leads to inherent analysis error. The purpose of our study is to quantify this error and to propose gel dosimeter based verification technique for 3-dimensional target point error. The phantom was made for simulation of human head and this has ability to equip 10 gel-dosimeter. $BANGkit^{TM}$ which we are able to manufacture whenever it is needed as well as to easily change the container with different shapes was used as a gel dosimeter. The 10 targets were divided into two groups based on shapes of areas with a planned 50% isodose line. All treatment and analysis was performed three times using Novalis and $BrainSCAN^{TM}$. The target point error is $0.77{\pm}0.15mm$ for 10 targets and directional target point error in each direction is $0.54{\pm}0.23mm$, $0.37{\pm}0.08mm$, $0.33{\pm}0.10mm$ in AP (anterior-posterior), LAT (lateral), and VERT (vertical) direction, respectively. The result of less than 1 mm shows that the treatment was performed through each precise step in treatment procedure. In conclusion, the 3-dimensional target point verification technique can be one of the techniques for overall system test.

Implicit Distinction of the Race Underlying the Perception of Faces by Event-Related fMRI (Event-related 기능적 MRI 영상을 통한 얼굴인식과정에서 수반되는 무의식적인 인종구별)

  • Kim Jeong-Seok;Kim Bum-Soo;Jeun Sin-Soo;Jung So-Lyung;Choe Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.1
    • /
    • pp.43-49
    • /
    • 2005
  • A few studies have shown that the function of fusiform face area is selectively involved in the perception of faces including a race difference. We investigated the neural substrates of the face-selective region called fusiform face area in the ventral occipital-temporal cortex and same-race memory superiority in the fusiform face area by the event-related fMRI. In our fMRI study, subjects (Oriental-Korean) performed the implicit distinction of the race while they consciously made familiar-judgments, regardless of whether they considered a face as Oriental-Korean or European-American. For race distinction as an implicit task, the fusiform face areas (FFA) and the right parahippocampal gyrus had a greater response to the presentation of Oriental-Korean faces than for the European-American faces, but in the conscious race distinction between Oriental-Korean and European-American faces, there was no significant difference observed in the FFA. These results suggest that different activation in the fusiform regions and right parahippocampal gyrus resulting from superiority of same-race memory could have implicitly taken place by the physiological processes of face recognition.

  • PDF

The Secondary Contiguous or Non-contiguous Subchondral Bone Impactions in Subaxial Cervical Spinal Injury: Incidence and Associated Primary Injury Patterns (축추이하 경추 손상에서 이차적으로 발생하는 연속적, 비연속적 연골하골 압박손상의 빈도와 원발부위 손상 패턴)

  • Han, Jun Gu;Kim, Yeo Ju;Yoon, Seung Hwan;Cho, Kyu Jung;Kim, Eugene;Kang, Young-Hye;Lee, Ha Young;Cho, Soon Gu;Kim, Mi Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.232-243
    • /
    • 2014
  • Purpose : To evaluate the incidence of secondary contiguous or non-contiguous subchondral bone impactions (SBI) in subaxial cervical spinal injury and associated primary injury patterns. Materials and Methods: A retrospective review of computed tomography, magnetic resonance imaging, and medical records was carried out for 47 patients who had sustained a subaxial cervical spinal injury. Presence, number, level, and sites of secondary contiguous or non-contiguous SBI were recorded. To evaluate primary injury patterns, the level and number of primary injury sites of subaxial cervical spine injury, injury morphology, anterior/posterior discoligamentous complex (ADC/PDC) injury, posterior ligamentous complex (PLC) injury, spinal cord injury, and mechanism of injury (MOI) were analyzed. Differences in primary injury pattern of subaxial cervical spine injury and MOI between patients with and without SBI, and between contiguous or non-contiguous SBI were analyzed using the Mann-Whitney U test, Pearson's chi square test and Fisher's exact test. Results: Eighteen patients (18/47, 38.29%) had developed contiguous (n=9) or non-contiguous (n=9) SBI, most commonly involving T3 (15/47, 31.91%) and 3 levels (6/18, 33.33%). All SBIs had developed near the anterosuperior region of the body and the superior endplate and were the result of a high-impact MOI. SBIs were statistically significant in association with injury morphology and PLC injury (P=0.001, P=0.009, respectively) at the primary injury site. Non-contiguous SBI was more frequently accompanied by upper cervical spinal injuries in association with PDC injuries, as opposed to contiguous SBI, with statistical significance (P=0.009), while no other statistically significant differences were found. Conclusion: Secondary SBIs are common and probably associated with subaxial cervical spinal injuries with high energy compressive flexion forces.

Responses and Toxicities of Risk-adapted Chemotherapy in Pediatric Intracranial Germ Cell Tumors (소아 두개 내 생식 세포종에서 위험군에 따른 화학요법의 치료 반응 및 독성)

  • You, Dong Kil;Lee, Soo Hyun;Yoo, Keon Hee;Sung, Ki Woong;Lim, Do Hoon;Shin, Hyung Jin;Koo, Hong Hoe
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.2
    • /
    • pp.186-190
    • /
    • 2005
  • Purpose : The purpose of this study was to evaluate the responses and toxicities of risk-adapted chemotherapy in pediatric intracranial germ cell tumors(IC-GCT). Methods : Fourteen patients who were diagnosed as IC-GCT from October 2002 to December 2003 received chemotherapy as an initial treatment modality. The low risk(LR) group was defined as follows : Pure germinoma and normal AFP level. Beta-hCG level 50 mIU/mL or less. The others belonged to the high risk(HR) group. Chemotherapy was composed of cisplatin, cyclophosphamide, etoposide and vincristine. Double doses of cisplatin and cyclophosphamide was used in HR patients. Results : Pathologic confirmation was done in all but one. Median age at diagnosis was 11.6 yr (1.2-18.7 yr), and nine patients belonged to the HR group. Tumor markers were normalized after chemotherapy in all patients whose tumor markers had been elevated. Four LR patients(80 percent) and seven HR patients(77.8 percent) showed complete response(CR) at the end of chemotherapy. An additional two of the three patients with partial response(PR) achieved CR after radiation therapy (RT), and the remaining one relapsed before RT. Four LR and all HR patients experienced infectious episodes that required hospitalization. Four of the nine HR patients(44.4 percent) suffered from tinnitus, three of whom developed sensorineural hearing loss. All but one are surviving, event-free, with a median follow-up of 13.9 mo(8.1-22.3 mo). Conclusion : Risk-adapted cisplatin-based chemotherapy was effective even in HR patients, but regimen modification seems to be necessary to avoid an unacceptably high toxicity rate.

A Study on the Repeat Tests for Diagnosis at a Tertiary Hospital in Taegu City (3차진료기관(3次診療機關)과 환자의뢰기관간(患者依賴機關間)의 중복검사(重複檢査))

  • Park, Jae-Yong;Kim, Gui-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.3 s.43
    • /
    • pp.457-468
    • /
    • 1993
  • This study was conducted to investigate the repeat test rate for diagnosis at a tertiary hospital for the outpatients who were referred themselves to the hospital by the clinics and other medical facilities. The study population consisted of 498 patients who visited outpatient department of internal medicine, general surgery, orthopedic surgery and neurosurgery in the hospital between March 16 and April 11, 1992. This study was surveyed by the questionnaire about the tests for diagnosis at first level medical facilities, and then, was investigated by the medical record about the tests for diagnosis at a tertiary hospital. The proportion of test among the patients who utilized the first level medical facilities was 20.9% for the X-ray test, 10.6% for the urinalysis, 9.0% for the electrocardiogram, 3.4% for the computer tomogram and 6.4% for the ultrasonogram. At the tertiary hospital, the X-ray test was 45.2%, the liver function test was 24.1%, the urinalysis was 19.1%, and the electrocardiogram was 15.7%. The proportion of patients who possessed results of test for diagnosis at the first level medical facilities was 76.5% for the computer tomogram, and 31.3% for the ultrasonogram. As the repeat test rate between the first level medical facilities and the tertiary hospital, the thyroid function test was the first rank as 71.4%, the second rank was the routine CBC as 67.9%, and the third rank was the X-ray test as 64.4%. But among the patients that brought the result for tests at the first level medical facilities, the repeat test rate was as follow : the routine CBC was 75.0%, the liver function test was 72.1%, and the computer tomogram was 15.4%.

  • PDF

Comparisons between the Two Dose Profiles Extracted from Leksell GammaPlan and Calculated by Variable Ellipsoid Modeling Technique (렉셀 감마플랜(LGP)에서 추출된 선량 분포와 가변 타원체 모형화기술(VEMT)에 의해 계산된 선량 분포 사이의 비교)

  • Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • A high degree of precision and accuracy in Gamma Knife Radiosurgery(GKRS) is a fundamental requirement for therapeutical success. Elaborate radiation delivery and dose gradients with the steep fall-off of radiation are clinically applied thus necessitating a dedicated Quality Assurance(QA) program in order to guarantee dosimetric and geometric accuracy and reduce all the risk factors that can occur in GKRS. In this study, as a part of QA we verified the accuracy of single-shot dose profiles used in the algorithm of Gamma Knife Perfexion(PFX) treatment planning system employing Variable Ellipsoid Modeling Technique(VEMT). We evaluated the dose distributions of single-shots in a spherical ABC phantom with diameter 160 mm on Gamma Knife PFX. The single-shots were directed to the center of ABC phantom. Collimating configurations of 4, 8, and 16 mm sizes along x, y, and z axes were studied. Gamma Knife PFX treatment planning system being used in GKRS is called Leksell GammaPlan(LGP) ver 10.1.1. From the verification like this, the accuracy of GKRS will be doubled. Then the clinical application must be finally performed based on precision and accuracy of GKRS. Specifically the width at the 50% isodose level, that is, Full-Width-of-Half-Maximum(FWHM) was verified under such conditions that a patient's head is simulated as a sphere with diameter 160mm. All the data about dose profiles along x, y, and z axes predicted through VEMT were excellently consistent with dose profiles from LGP within specifications(${\leq}1mm$ at 50% isodose level) except for a little difference of FWHM and PENUMBRA(isodose level: 20%~80%) along z axis for 4 mm and 8mm collimating configurations. The maximum discrepancy of FWHM was less than 2.3% at all collimating configurations. The maximum discrepancy of PENUMBRA was given for the 8 mm collimator along z axis. The difference of FWHM and PENUMBRA in the dose distributions obtained with VEMT and LGP is too small to give the clinical significance in GKRS. The results of this study are considered as a reference for medical physicists involved in GKRS in the whole world. Therefore we can work to confirm the validity of dose distributions for all collimating configurations determined through the regular preventative maintenance program using the independent verification method VEMT for the results of LGP and clinically assure the perfect treatment for patients of GKRS. Thus the use of VEMT is expected that it will be a part of QA that can verify and operate the system safely.

Evaluation of Glioma with Thallium-201 Brain SPECT: The Correlation with $^1H$ MR Spectroscopy and Pathology ($^{201}Tl$ 뇌 SPECT을 이용한 신경교종의 평가)

  • Sohn, Hyung-Sun;Kim, Euy-Neyng;Kim, Sung-Hoon;Yoo, Ie-Ryung;Chung, Yong-An;Chung, Soo-Kyo;Hong, Yong-Gil;Lee, Youn-Soo;Choe, Bo-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.465-477
    • /
    • 2000
  • Purpose: Thallim-201 ($^{201}Tl$) brain SPECT and proton ($^1H$) magnetic resonance spectroscopy (MRS) have been used to evaluate tumor grade and viability of glioma. We assessed the correlations between $^{201}Tl$ brain index or spectrum of metabolites of $^1H$ MRS and grade of glioma or histopathologic findings. Materials and Methods: We studied 17 patients (4 astrocytoma, 7 anaplastic astrocytoma and 6 glioblastoma). On $^{201}Tl$ Brain SPECT, $^{201}Tl$ index was measured as the ratio of average counts for region of interest to those for the contralateral normal brain. On $^1H$ MRS, we calculated choline (Cho) /creatine (Cr) ratio and N-acetylaspartate (NAA)/Cr ratio in ROI defined as tumor center. Histopathologic findings were graded by Ki-67 index, cellularity, mitosis, pleomorphism, necrosis and endothelial proliferation. An unpaired t test and statistical correlations were performed to evaluate these data. Results: Tl-index showed the best correlation with Ki-67 index (p<0.01), less correlations with cellularity, mitosis, and endothelial proliferation, but no correlation with results of MRS, pleomorphism, or necrosis. The findings of MRS did not correlate with all of the above. The cases of glioblastoma demonstrated a higher Tl-index, Cho/cr ratio, Ki-67 index and lower NAA/Cr ratio, albeit without statistical significance. Conclusion: Even though $^{201}Tl$ brain SPECT did not correlate directly with grade of malignancy, it may still be useful in determining biological aggressiveness of tumor and prognosis of patients because it correlated well with Ki-67 index, a growth fraction of glioma, cellularity, mitosis and endothelial proliferation.

  • PDF

Asymmetry of Medial and Lateral Temporal Regional Glucose Metabolism in Temporal Lobe Epilepsy by F-18-FDG PET (측두엽 간질에서 F-18-FDG PET에 나타난 측두엽 내외측 부위별 대사의 차이)

  • Lee, Dong-Soo;Yeo, Jeong-Seok;Song, Ho-Cheon;Lee, Sang-Kun;Kim, Hyun-Jip;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.28-39
    • /
    • 1999
  • Purpose: We investigated the difference of glucose metabolism of medial and lateral temporal lobes of patients with temporal lobe epilepsy (TLE) utilizing quantitative comparison of regional metabolic activities using asymmetric index. Materials and Methods: We studied 19 pathologically proven mesial TLE and 25 lateral TLE patients. Lateral TLE patients were either normal on magnetic resonance imaging (cryptogenic: n=14) or had structural lesions (lesional: n= 11). Asymmetric index (ASI) was calculated as [(ipsilateral-contralateral)/(ipsilateral+contralateral)]${\times}200$. Results: ASI of medial and lateral lobes of mesial TLE was decreased ($-16.4{\pm}8.3$ and $-12.1{\pm}5.5$, respectively). In cryptogenic lateral TLE, ASI of lateral temporal lobe was decreased ($-11.8{\pm}4.7$), whereas that of medial temporal lobe was not decreased ($-4.6{\pm}6.3$). ASI of medial lobe of lesional lateral TLE was $-7.3{\pm}9.1$, which was significantly different from that of mesial TLE (p<0.05). Patients with lesional lateral TLE had evident metabolic defects or decrease (ASI: $-22{\pm}10.5$) in lateral temporal lobe. While we could not find the difference of metabolic activity in lateral temporal lobes between cryptogenic lateral TLE and mesial TLE patients, the difference of metabolic activity was significant in medial temporal lobes which was revealed by ASI quantitation. Conclusion: Asymmetric decrease of metabolic activity in both medial and lateral temporal lobes indicates medial temporal epilepsy. Symmetry of metabolic activity in medial temporal lobe combined with asymmetry of that in lateral temporal lobe may give hints that the epileptogenic zone is lateral.

  • PDF

Stereotactic Target Point Verification in Actual Treatment Position of Radiosurgery (방사선수술시 두개내 표적의 정위적좌표의 치료위치에서의 확인)

  • Yun, Hyong-Geun;Lee, Hyun-Koo
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.403-409
    • /
    • 1995
  • Purpose : Authors tried to enhance the safety and accuracy of radiosurgery by verifying stereotacitc target point in actual treatment position prior to irradiation. Materials and Methods : Before the actual treatment, several sections of anthropomorphic head phantom were used to create a condition of unknown coordinates of the target point. A film was sandwitched between the phantom sections and punctured by sharp needle tip. The tip of the needle represented the target point. The head phantom was fixed to the stereotactic ring and CT scan was done with CT localizer attached to the ring. After the CT scanning, the stereotactic coordinates of the target point were determined. The head phantom was secured to accelerator's treatment couch and the movement of laser isocenter to the stereotactic coordinates determined by CT scanning was performed using target positioner. Accelerator's anteroposterior and lateral portal films were taken using angiographic localizers. The stereotactic coordinates determined by analysis of portal films were compared with the stereotactic coordinates previously determined by CT scanning. Following the correction of discrepancy the head phantom was irradiated using a stereotactic technique of several arcs. After the irradiation, the film which was sandwitched between the phantom sections was developed and the degree of coincidence between the center of the radiation distribution with the target point represented by the hole in the film was measured. In the treatment of the actual patients, the way of determining the stereotactic coordinates with CT localizers and angiograuhic localizers was the same as the phantom study. After the correction of the discrepancy between two sets of coordinates, we proceeded to the irradiation of the actual patient. Results : In the phantom study, the agreement between the center of the radiation distribution and the localized target point was very good. By measuring optical density profiles of the sandwitched film along axes that intersected the target point, authors could confirm the discrepancy was 0.3 mm. In the treatment of an actual patient, the discrepancy between the stereotactic coordinates with CT localizers and angiographic localizers was 0.6 mm. Conclusion : By verifying stereotactic target point in actual treatment position prior to irradiation, the accuracy and safety of streotactic radiosurgery procedure were established.

  • PDF