• 제목/요약/키워드: Network Transmission

검색결과 4,570건 처리시간 0.03초

서울시내 실업계 여고생들의 성지식 태도 및 행위에 관한 조사연구 (A Study on the Knowledge. Attitude and Behavior of Commercial Girl's High School Students Toward Sex)

  • 배남숙
    • 보건교육건강증진학회지
    • /
    • 제1권1호
    • /
    • pp.57-71
    • /
    • 1983
  • Sex education is necessary for the youth that they should have an adequate sexual knowledge, attitudes and behaviors in their adolescent period. Four major objectives of this study are as follows; 1. To know the level of sexual knowledge of commercial girl's high school students in Seoul. 2. To know their actual state for the attitudes and behaviors toward sex. 3. To compare the sexual knowledge, attitudes and behaviors of day time school students with those of night time school students. 4. To compare the factors associated with their sexual knowledge, attitudes and behaviors with the individual level. Data were collected on 986 students in Seoul from April 1 to April 10, 1983. As the result of this survey, the following conclusions were obtained. 1. The level of sexual knowledge. (1) The level of knowledge of day time high school students about the physiology of female and pregnancy is shown higher than those of night time students. 64.2% of the respondents are aware of the organ producing ovum. 56.4% the ovulation period. 95.6% the cause of pregnancy. 74.5% the pregnantable period and 12.7% the place of fetilization. (2) Out of 986 respondents. 71.8% knew about contraceptive method correctly, and day time school students knew litter better than night time school students, by showing 73.9% and 69.7% respectively. They knew about contraceptive method with 'oral pills'. 'menstrual cycles', 'condoms'. and 'loops' in the same order. 3) Kinds of veneral disease was correctly known by 37.9%. Day time students knew much better than night time school students. by showing 67.8% and 7.9%. respectively. Transmission method of veneral disease was correctly known by 28.3%. Day time students knew much better than night time students, by showing 51.2% and 5.3%, respectively. (4) The major information source of sexual knowledge was 'book and magazine' (39.9%) and 'friends' (27.4%). 2. Actual state of attitudes and behaviors toward sex. (1) Out of 986 respondents, 84.0% answered that premarital purity should be kept. (2) Out of 986 respondents, 60.8% had an acquaintance of the opposite sex. 45.2% of students with opposite sex reported introduction of their friends as the main channel of making an acquaintance of the opposite sex. (3) Of those who responded to this study 13.8% reported having masturbation, 21.5% kissing, 6.2% petting and 3.7% sex intercourse. (4) 64.8% had sexual problems, which was mensturance (27.2%), aquaintance of the opposite sex (25.4%). The main method to solve the problems were consultation with 'friends' and 'books and magazine' percentage being 39.1% and 30.8%, respectively, whereas very small students discussed with 'teachers' and 'parents' percentages being 0.3% and 5.9%, respectively. (5) Out of 986 respondents, 62.2% had experience in educating about sex, the percentage of day time school was higher than that of night time school. (6) 88.2% of students wanted sex education in school, which were 'general information about sex' (35.4%), 'sexual morality and solution of sexual desire' (18.5%), 'aquaintance of the opposite sex' (13.3%) and 'marriage and role of man and woman' (12.4%) in the same order. They wanted to be instructed about sexes in the lecture of physical education, home economics, biology, military training (59.9%), regular curriculum (17.5%), special lecture (16.9%) and by the counselor or school nurse (5.7%). 3. Analyse concerning the factors about the knowledge, attitudes and behaviors. (1) The better school record was, the higher the level of sexual knowledge. (2) Those who have the religion considered the permarital purity more important than those who have not, the percentage showing 86.7% and 80.7%, respectively. (3) The result of dyad analysis of making acquaintance of the opposite sex in the friendship network showed that a high index of the acquaintance of the opposite sex tends to be a high adoption of making one at the individual level in the group, while the low index tends to be a low adoption of making one in the group.

  • PDF

무선전용 다중 언어의 번역을 지원하는 변환기의 구현 (Development of Convertor supporting Multi-languages for Mobile Network)

  • 최지원;김기천
    • 정보처리학회논문지C
    • /
    • 제9C권2호
    • /
    • pp.293-296
    • /
    • 2002
  • 유선 환경에서 시작한 인터넷에 현재 존재하고 있는 웹 컨텐츠들을 모바일 환경에서 이용할 수 있게 하기 위하여 UP. Link 에서는 자동으로 HTML을 HDML로 번역해주는 기능을 가지고 있다. UP 브라우저에서 HTML 페이지를 억세스할 때 UP.Link 내의 에이전트는 번역기에게 HTML과 HDML 간의 번역을 처리하게끔 한다. I-Mode는 일본의 NTT-Docomo에서 개발 되었으며 이미 여러 가지 서비스를 통해 엄청난 컨텐츠를 보유하고 있다. Stinger 프로젝트에 의해 개발된 ME(Micro Explorer) 또한 많은 부가기능를 가지고 있다. 본 논문에서는 WAP에서 C-HTML과 mHTML의 컨텐츠를 수용할 수 있는 변환기를 설계하고 구현하였다. I-Mode의 C-HTML과 MS사의 ME는 HTML의 간이형으로 컨텐츠 제공 업자들이 다른 언어를 익힐 필요가 없으므로 WAP에 비해 컨텐츠 개발에 유리하다. C-HTML과 WML은 모두 모바일 환경에서 쓰이기 때문에 한 페이지 내에 제한되어 있는 용량 또한 비슷하다. 그러므로 C-HTML을 WML로, mHTML을 WML로 바꾸는 변환기를 개발하기 위해서 먼저 각 언어와 관련된 스펙을 분석하고 각각의 서로 대응되는 element를 찾아 표를 작성하고 난 후에 변환을 위한 알고리즘을 적용하여 변환기를 구현한다. 만약 대응되는 element가 없을 경우에는 WML에서 지원하는 여러 가지의 태그들을 조합하여 최대한 같은 형식으로 디스플레이 해줄 수 있는 방안을 제시한다. 편집기에서는 변환된 WML 소스를 컨텐츠 저작자가 클립 기능을 이용하여 다른 내용을 추가하거나 내용을 바꿀 수 있도록 지원한다. 구현 결과 약 90% 이상의 변환이 가능하다.장 높았고 비만군이 9.840점(표준편차 4.638)로 가장 낮았으며, 남자에서는 과체중군이 14.780점(표준편차 4.601), 여자에서는 저체중군이 12.284점(표준편차 4.604)으로 체형존중감이 가장 높았고, 남(평균 10.166점, 표준편차 4.246), 여(평균 8.772점, 표준편차 5.723) 모두 비만군에서 체형존중감이 가장 낮았다. 4. 비만도와 체형만족도 및 체형존중감과의 상관관계는 비만도와 체형만족도(r= -.2081, p= .000), 비만도와 체형존중감(r= -.2250, p= .000)은 유의한 역상관관계를 나타내어 비만도가 높을수록 체형만족도와 체형존중감이 낮았다. 5. 일반적 특성에 따른 비만상태는 전체에서는 성별($chi^2$=88.136, p=.000), 체형에 대한 인식($chi^2$=242.371, p= .000)에서, 남자에서는 부의 체형($chi^2$=15.11, p= .019), 체형에 대한 인식($chi^2$=138.95, p= .000)에서, 여자에서는 모의 학력($chi^2$=19.46, p= .022), 체형에 대한 인식($chi^2$=143.35, p= .000)에서 유의한 차이가 있었다. 전체에서 성별은 남자에서 비만은 21.4%, 여자에서 비만은 6.6%로 남자가 비만인 경우가 더 많았고, 체형에 대한 인식은 자신의 체형이 말랐다고 인식하는 경우 비만은 0.7%, 보통이라고 인식하는 경우 비만은 9.3%, 비만하다고 인식하는 경우 비만은 64.6%로 나타났다. 남자에서 부의 체형이 마른 경우 실제 비만인 학생은 21.20%, 보통인 경우

Smart미디어시대 정보통신·미디어(ICT) 분야 규범체계의 재구조화에 관한 연구 (A Study on the Restructuration of Norm System in the Field of ICT for the Smart Media)

  • 지성우
    • 법제연구
    • /
    • 제44호
    • /
    • pp.33-62
    • /
    • 2013
  • 이 논문에서는 최근 단행된 정부조직 개편의 결과 탄생한 미래창조과학부와 방송통신위원회 등의 소관 법률의 가장 최상위의 ICT관련 법제의 정비와 아울러 기본법으로서의 성격을 갖는 ICT특별법에 담겨야할 헌법적 차원이 기본 문제와 몇 가지 쟁점들에 대해 이론적 실제적 차원에서 논의하였다. 정보통신기술의 발전은 인류의 생활방식을 혁명적으로 변화 시켰으며, 전지구적 차원의 네트워크 사회의 출현은 경제적 사회적 기회와 혜택을 제공 하였지만 동시에 도전과 위협의 이슈가 끊임없이 제기되고 있다. 기술발전에 따른 많은 장점에도 불구하고 디지털 혁명으로 인하여 인류가 누리게 된 인터넷 등 온라인 매체를 통한 사이버공간은 현실적으로 해결해야 할 많은 문제들이 있다. 전송기술의 발전으로 인한 표현의 자유의 통로 확대와 경제적 기획 창출이라는 긍정적인 측면을 보다 발전시켜 나가기 위해서는 정보화로 인한 따른 부작용을 최소화하려는 노력이 절실하게 필요하다. 첫째, ICT특별법은 역사적으로 방송통신융합을 넘어선 미디어의 융합시대에 적헙하도록 규범화되어야 한다. 향후 정보화와 정보통신 기술 및 콘텐츠의 개발과 아울러 미디어 분야에서도 경제적 발전과 아울러 언론의 자유를 수호라는 두 가지의 정책을 모두 달성할 수 있는 근거규정이 마련되어야 한다. 둘째, 규범구조적 측면에서는 정부의 행위들은 모두 경제발전과 정보의 자유라는 목표를 달성하기 위한 것이라는 점을 깊이 명심해야 한다. 따라서 정치적 차원에서 말끔하게 해결되지 못한 조직개편의 문제점을 규범적 관점 해소함으로써 소모적 갈등의 발생가능성을 최소화할 수 있도록 노력해야 한다. 셋째, ICT특별법은 미래부가 소관하는 정보통신분야, 유료 방송분야, 디지털미디어 콘텐츠 분야를 모두 포괄하는 내용의 기본법적 성격을 가지는 규범이어야 한다. 넷째, 기술적인 관점에서는 ICT융합으로 인해 발생하는 망중립성의 문제, 디지털 콘텐츠를 둘러싼 이해관계의 대립 등 다양한 문제점들을 해결할 수 있어야 한다. ICT특별법은 정보화를 통해 일방적으로 효율성이나 산업의 발전만을 추구하는 것이 아니라, 정보화가 국민의 삶의 질을 높이고 우리 사회의 민주화를 촉진할 수 있도록 제도의 설계와 구축하는 것을 목표로 하여야 한다. 향후 이번 ICT특별법의 입안과정에서 논의하고 있는 다양한 관점들을 참고하여 정보통신기술의 강국임과 동시에 정보인권분야에서도 한 발 앞서가는 계기가 마련되어야 한다.

6-7세기의 동남아 힌두 미술 - 인도 힌두미술의 전파와 초기의 변용 - (Southeast Asian Hindu Art from the 6th to the 7th Centuries)

  • 강희정
    • 동남아시아연구
    • /
    • 제20권3호
    • /
    • pp.263-297
    • /
    • 2010
  • The relics of the Southeast Asian civilizations in the first phase are found with the relics from India, China, and even further West of Persia and Rome. These relics are the historic marks of the ancient interactions of various continents, mainly through the maritime trade. The traces of the indic culture, which appears in the historic age, are represented in the textual records and arts, regarded as the essence of the India itself. The ancient Hindu arts found in various locations of Southeast Asia were thought to be transplanted directly from India. However, Neither did the Gupta Hindu Art of India form the mainstream of the Gupta Art, nor did it play an influential role in the adjacent areas. The Indian culture was transmitted to Southeast Asia rather intermittently than consistently. If we thoroughly compare the early Hindu art of India and that of Southeast Asia, we can find that the latter was influenced by the former, but still sustained Southeast Asian originality. The reason that the earliest Southeast Asian Hindu art is discovered mostly in continental Southeast Asia is resulted from the fact that the earliest networks between India and the region were constructed in this region. Among the images of Hindu gods produced before the 7th century are Shiva, Vishnu, Harihara, and Skanda(the son of Shiva), and Ganesha(the god of wealth). The earliest example of Vishnu was sculpted according to the Kushan style. After that, most of the sculptures came to have robust figures and graceful proportions. There are a small number of images of Ganesha and Skanda. These images strictly follow the iconography of the Indian sculpture. This shows that Southeast Asians chose their own Hindu gods from the Hindu pantheon selectively and devoted their faiths to them. Their basic iconography obediently followed the Indian model, but they tried to transform parts of the images within the Southeast Asian contexts. However, it is very difficult to understand the process of the development of the Hindu faith and its contents in the ancient Southeast Asia. It is because there are very few undamaged Hindu temples left in Southeast Asia. It is also difficult to make sure that the Hindu religion of India, which was based on the complex rituals and the caste system, was transplanted to Southeast Asia, because there were no such strong basis of social structure and religion in the region. "Indianization" is an organized expansion of the Indian culture based on the sense of belonging to an Indian context. This can be defined through the process of transmission and progress of the Hindu or Buddhist religions, legends about purana, and the influx of various epic expression and its development. Such conditions are represented through the Sanskrit language and the art. It is the element of the Indian culture to fabricate an image of god as a devotional object. However, if we look into details of the iconography, style, and religious culture, these can be understood as a "selective reception of foreign religious culture." There were no sophisticated social structure yet to support the Indian culture to continue in Southeast Asia around the 7th century. Whether this phenomena was an "Indianization" or the "influx of elements of Indian culture," it was closely related to the matter of 'localization.' The regional character of each local region in Southeast Asia is partially shown after the 8th century. However it is not clear whether this culture was settled in each region as its dominant culture. The localization of the Indian culture in Southeast Asia which acted as a network connecting ports or cities was a part of the process of localization of Indian culture in pan-Southeast Asian region, and the process of the building of the basis for establishing an identity for each Southeast Asian region.

소형 초고속해상무선통신망 송수신기 성능 검증 방안에 관한 연구 (A Study on the Performance Verification Method of Small-Sized LTE-Maritime Transceiver)

  • 우석;김부영;심우성
    • 해양환경안전학회지
    • /
    • 제29권7호
    • /
    • pp.902-909
    • /
    • 2023
  • 해양사고 예방 지원을 목표로 해양수산부 주도의 지능형 해상교통정보서비스가 지난 21년 1월부터 시작되었고 그동안 이용이 제한되었던 3톤 미만 선박까지 확대하기 위해 개발·추진되는 소형 초고속해상무선통신망(이하 LTE-M) 송수신기의 성능 검증 방안에 대해 연구하였다. 국내 해양 사고의 약 30%가 3톤 미만의 선박에서 발생되고 있기 때문에 소형 선박 전용의 송수신기 개발을 통한 해양안전 사각지대 보완이 필요하다. 소형 LTE-M 송수신기는 연안에서 조업 활동이 활발한 어선과 육지 인근의 수상레저기구 등을 대상으로 적용될 수 있다. 따라서 실제 송수신기가 설치·이용되는 환경을 고려하여 충분한 성능 및 안정적인 통신 품질 제공 여부를 검증하는 방안이 필요하다. 본 연구에서는 LTE-M 망의 통신품질 요구 기준과 해양수산부의 소형 송수신기 성능 요구 기준을 검토해보고, 소형 송수신기의 성능을 적합하게 평가할 수 있는 시험 방안을 제안하였다. 제안한 시험 방안은 해양 사고 빈도가 높은 6개 실해역 노선을 대상으로 타당성을 검증하였으며, 소형 송수신기 다운링크 및 업링크 전송속도가 각각 9Mbps 이상 및 3Mbps 이상의 성능을 보임을 확인할 수 있었다. 또한 커버리지 분석시스템을 활용하여 집중관리구역(0~30km) 및 관심구역(30~50km)에서 각 95% 이상 및 100%의 커버리지를 확인하였다. 본 논문에서 제안한 성능 평가 방안 및 시험 결과는 송수신기의 성능 검증을 위한 참고 자료로 활용되어 정부가 추진하는 바다 내비게이션 서비스 및 소형 송수신기의 보급 및 확산에 기여할 것으로 기대된다.

Immune Cells Are Differentially Affected by SARS-CoV-2 Viral Loads in K18-hACE2 Mice

  • Jung Ah Kim;Sung-Hee Kim;Jeong Jin Kim;Hyuna Noh;Su-bin Lee;Haengdueng Jeong;Jiseon Kim;Donghun Jeon;Jung Seon Seo;Dain On;Suhyeon Yoon;Sang Gyu Lee;Youn Woo Lee;Hui Jeong Jang;In Ho Park;Jooyeon Oh;Sang-Hyuk Seok;Yu Jin Lee;Seung-Min Hong;Se-Hee An;Joon-Yong Bae;Jung-ah Choi;Seo Yeon Kim;Young Been Kim;Ji-Yeon Hwang;Hyo-Jung Lee;Hong Bin Kim;Dae Gwin Jeong;Daesub Song;Manki Song;Man-Seong Park;Kang-Seuk Choi;Jun Won Park;Jun-Won Yun;Jeon-Soo Shin;Ho-Young Lee;Ho-Keun Kwon;Jun-Young Seo;Ki Taek Nam;Heon Yung Gee;Je Kyung Seong
    • IMMUNE NETWORK
    • /
    • 제24권2호
    • /
    • pp.7.1-7.19
    • /
    • 2024
  • Viral load and the duration of viral shedding of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are important determinants of the transmission of coronavirus disease 2019. In this study, we examined the effects of viral doses on the lung and spleen of K18-hACE2 transgenic mice by temporal histological and transcriptional analyses. Approximately, 1×105 plaque-forming units (PFU) of SARS-CoV-2 induced strong host responses in the lungs from 2 days post inoculation (dpi) which did not recover until the mice died, whereas responses to the virus were obvious at 5 days, recovering to the basal state by 14 dpi at 1×102 PFU. Further, flow cytometry showed that number of CD8+ T cells continuously increased in 1×102 PFU-virus-infected lungs from 2 dpi, but not in 1×105 PFU-virus-infected lungs. In spleens, responses to the virus were prominent from 2 dpi, and number of B cells was significantly decreased at 1×105 PFU; however, 1×12 PFU of virus induced very weak responses from 2 dpi which recovered by 10 dpi. Although the defense responses returned to normal and the mice survived, lung histology showed evidence of fibrosis, suggesting sequelae of SARS-CoV-2 infection. Our findings indicate that specific effectors of the immune response in the lung and spleen were either increased or depleted in response to doses of SARS-CoV-2. This study demonstrated that the response of local and systemic immune effectors to a viral infection varies with viral dose, which either exacerbates the severity of the infection or accelerates its elimination.

비접촉 데이터 사회와 아카이브 재영토화 (Contactless Data Society and Reterritorialization of the Archive )

  • 조민지
    • 기록학연구
    • /
    • 제79호
    • /
    • pp.5-32
    • /
    • 2024
  • 한국 정부가 UN의 2022년 전자정부 발전 지수에서 UN가입 193개국 중 3위에 랭크됐다. 그동안 꾸준히 상위국으로 평가된 한국은 분명 세계 전자정부의 선도국이라 할 수 있다. 전자정부의 윤활유는 데이터다. 데이터는 그 자체로 정보가 아니고 기록도 아니지만 정보와 기록의 원천이며 지식의 자원이다. 전자적 시스템을 통한 행정 행위가 보편화된 이후 당연히 데이터에 기반한 기록의 생산과 기술이 확대되고 진화하고 있다. 기술은 가치중립적인 듯 보이지만 사실 그 자체로 특정 세계관을 반영하고 있다. 더구나 비물질적 유통을 기반으로 하는 디지털 세계, 온라인 네트워크의 또 다른 아이러니는 반드시 물리적 도구를 통해서만 접속하고 접촉할 수 있다는 점이다. 디지털 정보는 논리적 대상이지만 반드시 어떤 유형이든 그것을 중계할 장치 없이는 디지털 자원을 읽어 내거나 활용할 수 없다. 초연결, 초지능을 무기로 하는 새로운 기술의 디지털 질서는 전통적인 권력 구조에 깊은 영향력을 끼칠 뿐만 아니라 기존의 정보 및 지식 전달 매개체에도 마찬가지의 영향을 미치고 있다. 더구나 데이터에 기반한 생성형 인공지능을 비롯해 새로운 기술과 매개가 단연 화두다. 디지털 기술의 전방위적 성장과 확산이 인간 역능의 증강과 사유의 외주화 상황까지 왔다고 볼 수 있을 것이다. 여기에는 딥 페이크를 비롯한 가짜 이미지, 오토 프로파일링, 사실처럼 생성해 내는 AI 거짓말(hallucination), 기계 학습데이터의 저작권 침해에 이르기까지 다양한 문제점 또한 내포하고 있다. 더구나 급진적 연결 능력은 방대한 데이터의 즉각적 공유를 가능하게 하고 인지 없이 행위를 발생시키는 기술적 무의식에 의존하게 된다. 그런 점에서 지금의 기술 사회의 기계는 단순 보조의 수준을 넘어서고 있으며 기계의 인간 사회 진입은 고도의 기술 발전에 따른 자연적인 변화 양상이라고 하기에는 간단하지 않은 지점이 존재한다. 시간이 지나며 기계에 대한 관점이 변화하게 될 것이기 때문이다. 따라서 중요한 것은 기계를 통한 커뮤니케이션, 행위의 결과로서의 기록이 생산되고 사용되는 방식의 변화가 의미하는 사회문화적 함의에 있다. 아카이브 영역에서도 초지능, 초연결사회를 향한 기술의 변화로 인해 데이터 기반 아카이브 사회는 어떤 문제에 직면하게 될 것인지, 그리고 그 속에서 누가 어떻게 기록과 데이터의 지속적 활동성을 입증하고 매체 변화의 주요 동인이 될 것인가에 대한 연구가 필요한 시점이다. 본 연구는 아카이브가 행위의 결과인 기록뿐만 아니라 데이터를 전략적 자산으로 인식할 필요성에서 시작했다. 이를 통해 전통적 경계를 확장하고 데이터 중심 사회에서 어떻게 재영토화를 이룰 수 있을지를 알아보았다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

소비자의 부정적 브랜드 루머의 수용과 확산 (Consumer's Negative Brand Rumor Acceptance and Rumor Diffusion)

  • 이원준;이한석
    • Asia Marketing Journal
    • /
    • 제14권2호
    • /
    • pp.65-96
    • /
    • 2012
  • 루머는 신뢰할 만한 타당한 근거나 이유가 없음에도 불구하고 광범위하게 이야기되는 일상적인 대화나 의견으로서 오랜기간 소비자 개개인의 사적 영역의 문제였다. 그러나 대중의 사랑과 주목을 받는 기업이나 브랜드는 선천적으로 소비자의 관심으로부터 멀어질 수 없으며, 항상 루머의 주요한 소재가 되어 왔다. 그 결과 현대의 소비자 커뮤니케이션 환경에서 루머는 기업 경영활동에 중요한 위기 요인이 되고 있다. 기업과 브랜드들이 당면하는 소비자 루머들은 크게 기업과 관련된 음모성 루머와 상품과 직접적 관련이 있는 오염성 루머로 나누어지며 국내외에서 많은 위기 사례들이 발견되고 있다. 심지어 P&G, SK, 현대, 삼성처럼 잘 정비된 홍보 조직을 갖춘 굴지의 대기업들조차 이런 루머로부터 자유롭지 못하며, 기존의 대응방식 역시 적절하지 못했던 것이 사실이다. 부정적 루머가 주목받아야 하는 이유는 해당 기업의 매출 및 점유율 하락은 물론 주식 가격에도 부정적인 영향을 미치며 오랜기간 구축해온 소비자와의 관계마저 황폐화시킬 가능성이 있기 때문이다. 최근 인터넷, 소셜 네트워크 서비스의 확산과 더불어 브랜드와 관련된 루머의 중요성은 더욱 증대하고 있으나 루머 연구는 지금까지 기업이나 마케팅 연구자의 정당한 주목을 받지 못하였다. 이에 본 연구는 루머의 다각적인 측면을 고려하는 상황주의자적 연구 패러다임을 기반으로 지각된 유용성, 원천 신뢰성, 메시지 신뢰성, 걱정, 생동감과 같은 루머와 관련된 속성들이 루머 수용강도와 루머 구전의도에 미치는 영향을 분석하였다. 이를 위하여 가상 브랜드와 루머가 제시되었으며, 실증조사를 통한 데이터 수집과 분석이 이루어졌다. 연구 결과에 따르면 원천 신뢰성, 메시지 신뢰성, 걱정, 생동감 같은 루머 특성 변수들은 루머 수용 강도에 유의한 영향을 미치고, 루머 수용강도는 루머 구전의도에 유의한 영향을 미치는 것으로 나타났다. 반면에 지각된 중요성은 루머 수용강도에 유의한 영향을 미치지 못하며, 상품 관여도의 조절효과 역시 유의하지 않은 것으로 나타났다. 본 연구는 주요한 실무적, 학문적 시사점을 제공하고 있다. 첫째, 루머를 자연발생적인 사회 현상이 아니라 소비자의 주요 활동의 일부이며, 마케터의 관심과 대응 커뮤니케이션 전략이 필요한 브랜드 관련 현상임을 주장하였다. 둘째, 브랜드 루머의 심리적, 사회적인 다차원적 구성 요인과 확산되는 경로를 제시함으로서 루머에 대한 능동적인 관리 가능성을 제시하였다. 셋째, 온라인상의 루머 활동이 기업 성과에 미치는 영향을 제시함으로서 기업들의 적극적인 온라인 커뮤니케이션 활동과 평판 관리의 필요성을 주장하였다. 넷째, 소비자의 걱정과 같은 부정적 정서가 루머의 온상이 되고 있음을 규명함으로서 소비자의 의혹을 불식시키기 위하여 정확하고 진실된 정보를 제공해야 함을 주장하였다. 다섯째, 루머의 유용성이 확산에 미치는 영향 가설이 기각되었으며, 상품 관여도의 조절 효과 역시 기각되었다. 이는 루머를 접하는 소비자의 입장에서 볼 때, 루머 자체가 무의미하더라도 단순한 재미나 호기심만으로도 얼마든지 확산될 가능성을 암시하고 있다. 일부 기업들은 사실이 아니라는 이유만으로 루머를 무시하거나 간과하는 경우들이 있으나, 기업의 예상과 다르게 루머가 얼마든지 확산될 수 있는 가능성을 보여주며, 기업의 보다 세심한 대응 전략의 필요성을 요구하고 있다.

  • PDF