• 제목/요약/키워드: Nerve simulation

검색결과 44건 처리시간 0.04초

압반사 제어모델을 이용한 심혈관시스템 모델링 및 시뮬레이션 (Modeling and Simulation of the Cardiovascular System Using Baroreflex Control Model)

  • 최병철;전계록
    • 한국시뮬레이션학회:학술대회논문집
    • /
    • 한국시뮬레이션학회 2004년도 춘계학술대회 논문집
    • /
    • pp.109-117
    • /
    • 2004
  • In this paper, we consider the aortic sinus baroreceptor, which is the most representative baroreceptor sensing the variance of pressure in the cardiovascular system, and propose heart activity control model to observe the effect of delay time in heart period and stroke volume under the regulation of baroreflex in the aortic sinus. The proposed heart activity baroreflex regulation model contains electric circuit sub-model. We constituted the time delay sub-model to observe sensitivity of heart activity baroreflex regulation model by using the variable value to represent the control signal transmission time from the output of baroreflex regulation model to efferent nerve through central nervous system. The simulation object of this model is to observe variability of the cardiovascular system by variable value in time delay sub-model. As simulation results, we observe three patterns of the cardiovascular system variability by the time delay, First, if the time delay over 2.5 second, aortic pressure and stroke volume and heart rate is observed nonperiodically and observed. Finally, if time delay under 0.1 second, then heart rate and aortic pressure-heart rate trajectory is maintained in stable state.

  • PDF

The Short-Term Effects of Difference Frequency of Transcutaneous Electrical Nerve Stimulation on Pain Relief using c-fos Expression in Spinal Cord with Knee Osteoarthritis Rats

  • Koo, Hyun-Mo;Na, Sang-Su
    • 대한물리의학회지
    • /
    • 제11권4호
    • /
    • pp.49-54
    • /
    • 2016
  • PURPOSE: The purpose of this study was to determine the effect of different frequencies (4Hz and 100Hz) of transcutaneous electrical nerve simulation (TENS) on pain relief using c-fos expression in the spinal cord of rat osteoarthritis to investigate the appropriate frequency for pain relief. METHODS: Total of 30 Sprague-Dawley rats was used and randomly divided 2 groups according TENS frequency and applicate the TENS during 3 period (3 days, 7 days, 10 days). The induction of osteoarthritis by 3mg monosodium iodoacetat was injected into the right knee joint of rats. Three days later, commercially available TENS unit was used for stimulation was set to 20minutes on 3, 7, 10 days after surgery. Western blot analysis system was used to detect immunoreactive proteins. The thickness of the bands were photographically measured by Scion Image. RESULTS: When investigating the c-fos expression of TENS on spinal cord in OA knee over 10 days, between-groups differences in c-fos expression reached a significant level by day 10. For within-groups comparisons, the c-fos expression decreased significantly across days in low- and high-frequency TENS groups. CONCLUSION: Whether at low- and high-frequency, the TENS as a therapy obtained beneficial effects of pain relief and TNES at high-frequency is more beneficial effects on the pain relief when TENS applied at injury site.

인체 심혈관계의 이론적 분석을 위한 시스템 시뮬레이션모델에 관한 연구 (Systemic Simulation Models for the Theoretical Analysis of Human Cardiovascular System)

  • 고형종;윤찬현;심은보
    • 제어로봇시스템학회논문지
    • /
    • 제10권12호
    • /
    • pp.1181-1188
    • /
    • 2004
  • This paper reviews the main aspects of cardiovascular system dynamics with emphasis on modeling hemodynamic characteristics using a lumped parameter approach. Methodological and physiological aspects of the circulation dynamics are summarized with the help of existing mathematical models: The main characteristics of the hemodynamic elements, such as the heart and arterial and venous systems, are first described. Lumped models of micro-circulation and pulmonary circulation are introduced. We also discuss the feedback control of cardiovascular system. The control pathways that participate in feedback mechanisms (baroreceptors and cardiopulmonary receptors) are described to explain the interaction between hemodynamics and autonomic nerve control in the circulation. Based on a set-point model, the computational aspects of reflex control are explained. In final chapter we present the present research trend in this field and discuss the future studies of cardiovascular system modeling.

Computer Simulation Surgery for Mandibular Reconstruction Using a Fibular Osteotomy Guide

  • Jeong, Woo Shik;Choi, Jong Woo;Choi, Seung Ho
    • Archives of Plastic Surgery
    • /
    • 제41권5호
    • /
    • pp.584-587
    • /
    • 2014
  • In the present study, a fibular osteotomy guide based on a computer simulation was applied to a patient who had undergone mandibular segmental ostectomy due to oncological complications. This patient was a 68-year-old woman who presented to our department with a biopsy-proven squamous cell carcinoma on her left gingival area. This lesion had destroyed the cortical bony structure, and the patient showed attenuation of her soft tissue along the inferior alveolar nerve, indicating perineural spread of the tumor. Prior to surgery, a three-dimensional computed tomography scan of the facial and fibular bones was performed. We then created a virtual computer simulation of the mandibular segmental defect through which we segmented the fibular to reconstruct the proper angulation in the original mandible. Approximately 2-cm segments were created on the basis of this simulation and applied to the virtually simulated mandibular segmental defect. Thus, we obtained a virtual model of the ideal mandibular reconstruction for this patient with a fibular free flap. We could then use this computer simulation for the subsequent surgery and minimize the bony gaps between the multiple fibular bony segments.

인공 청각 장치의 음성신호 처리와 자극방법의 시뮬레이션 (Simulation of speech processing and coding strategy for cochlear implants)

  • 김영훈;박광석
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1991년도 추계학술대회
    • /
    • pp.30-33
    • /
    • 1991
  • The object of speech processor for cochlear implants is to deliver speech information to the central nerve system. In this study we have presented the method which simulate speech processing and coding strategy for cochlear implants and simulated two different processing methods to the 12 adults with normal ears. The formant sinusoidal coding was better than the formant pulse coding In the consonant perception test and learning effects.(p < 0.05)

  • PDF

The Effect of Frequency of Transcutaneous Electrical Nerve Stimulation (TENS) on Maximum Multi-finger Force Production

  • Karol, Sohit;Koh, Kyung;Kwon, Hyun Joon;Park, Yang Sun;Kwon, Young Ha;Shim, Jae Kun
    • 한국운동역학회지
    • /
    • 제26권1호
    • /
    • pp.93-99
    • /
    • 2016
  • Objective: The purpose of this study was to investigate the effect of transcutaneous electrical nerve stimulation (TENS) treatment on maximum voluntary force (MVF) production. Methods: Ten healthy, young subjects (5 males and 5 females) participated in the study. MVF was recorded after a fifteen minute session of TENS stimulation under two conditions: low frequency (4 Hz) at maximum tolerable level and high frequency (110 Hz) at maximum tolerable level. TENS was provided simultaneously via self-adhesive electrodes placed on the finger pads of the index, middle, ring and little fingers. MVF was also recorded in a baseline condition with no TENS treatment. Data were collected in three different sessions on three consecutive days at the sametime of the day. Results: Results from the study show that on an average, MVF increasesby 25% for the index, middle and little fingers for TENS treatment with 4 Hz frequency as compared to the baseline condition. However, the 110 Hz condition did not result in a significantly different MVF than the baseline condition during individual finger pressing tasks. In addition, while producing MVF with all the four finger stogether, MVF was 30% higher for the 4 Hz conditionin comparison to the baseline condition, and 15% higher for the 110 Hz condition in comparison to the baseline condition respectively. Conclusion: The results suggest that stimulation ofafferent fibers onthe glabrous skinwith TENS could have a net facilitatory effect on the maximum motoroutput.

단기적 자율조절기능을 포함하는 심혈관계 혈류역학 모델링에 관한 수치적 연구 (Computational Study on the Hemodynamics of Cardiovascular System Including Short-term Auto-regulation Functions)

  • 심은보;정찬일;최한고
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권5호
    • /
    • pp.393-402
    • /
    • 2001
  • 전체 심혈관계의 혈류역학적 특성을 분석할 수 있는 수치해석 방법을 개발하였다. 이는 12개의 요소들로 구성된 lumped parameter모델에 기초하고 있으며 인체의 신경계에 의한 자율조절기능을 모사하기 위해 주로 혈압의 단기적 조절을 위한.baroreflex system뿐 아니라 cardiopulmonary reflex 메커니즘가지도 구현하여 모델에 포함시켰다. 또한 교감 및 부교감 신경에 의한 자극-반응 전달을 구현함에 있어 생리학적 데이터에 기초한 방법을 사용하였다. 본 연구의 수치해석 코드를 검증하기 위하여 우선 보통 상태의 심혈관계에 대하여 혈류역학적 계산 결과를 기존의 참고문헌들에서의 값들과 비교 검토하였다. 심혈관계 모델의 혈류역학적 자극에 대한 반응 결과를 조사하기 위하여. 20% 출혈이 발생하는 경우와 LBNP(Lower Body Negative Pressure) 모사를 수행하였다. 두 경우 모두. 비교적 실험치와 잘 일cl하고 있음을 확인할 수 있었다. 특히 LBNP 수행 시, 외부압력의 크기가 커질수록 baroreflex만을 포함하고 있는 방법은 baroreflex와 cardiopulmonary reflex 모두를 포함하고 있는 방법에 비하여 다소 부정확한 결과를 보여주고 있는데. 이는 cardiopulmonary reflex 메커니즘의 중요성을 보여주고 있다.

  • PDF

공장자동화를 위한 필드버스 프로토골의 평가 (Evaluation of Fieldbus Protocal for Factory Automation)

  • 이경창;김인준;이석
    • 한국정밀공학회지
    • /
    • 제16권3호통권96호
    • /
    • pp.116-127
    • /
    • 1999
  • Networking for manufacturing is gaining importance as a nerve system of computer-integrated manufacturing (CIM). Among the various network types, the most inexpensive type called fieldbus is specifically aimed to interconnect simple devices such as sensors and actuators. For this purpose, there are several choices of the protocols such as Profibus. WorldFIP, Foundation Fieldbus, and IEC/ISA fieldbus. This paper presents the simulation results of Profibus and WorldFIP. Both protocols have been simulated in order to evaluate the performance such as transmission delay and throughput under different protocol parameter settings and traffic conditions.

  • PDF

ABR에서 반복회수 설정에 의한 전력선 잡음의 제거 (Power Line Noise Reductions in ABR by Properly Chosen Iteration Numbers)

  • 안주현;김수찬;남기창;심윤주;김희남;송철규;김덕원
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권3호
    • /
    • pp.241-247
    • /
    • 2001
  • ABR(auditory brainstem response) is one of the audiometry which measures objective hearing threshold level by acquiring electric evoked potentials emanated from auditory nerve system responding to an auditory stimulation. However, the obtained potentials which are largely interfered by power line noise, have extremely low SNR, thus ensemble average algorithm is generally used. The purpose of this study was to investigate the effect of iteration number in ensemble average on the reduction of the power line noise. The power line noise was modeled to be a 60 Hz sinusoidal signal and the energy of the modeled signal was calculated when it was averaged. It was verified by simulation that the energy had the periodic zero points for each stimulation rate, and 60 Hz signal induced by the power line was applied to the developed ABR system to confirm that the period of zero energy point was the same with that of the simulation. By the properly selected iteration number, power line noise could be reduced and more reliable ABR could be acquired.

  • PDF

식립 보조도구를 이용한 3D 치아 임플란트 시술 시뮬레이션 (3D Simulation of Dental Implant Surgery Using Surgical Guide Stents)

  • 박형욱;김명수;박형준
    • 한국CDE학회논문집
    • /
    • 제16권3호
    • /
    • pp.216-226
    • /
    • 2011
  • Surgeon dentists usually rely on their experiential judgments from patients' oral plaster casts and medical images to determine the positional and directional information of implant fixtures and to perform drilling tasks during dental implant surgical operations. This approach, however, may cause some errors and deteriorate the quality of dental implants. Computer-aided methods have been introduced as supportive tools to alleviate the shortcomings of the conventional approach. In this paper, we present an approach of 3D dental implant simulation which can provide the realistic and immersive experience of dental implant information. The dental implant information is primarily composed of several kinds of 3D mesh models obtained as follows. Firstly, we construct 3D mesh models of jawbones, teeth and nerve curves from the patient's dental images using software $Mimics^{TM}$. Secondly, we construct 3D mesh models of gingival regions from the patient's oral impression using a reverse engineering technique. Thirdly, we select suitable types of implant fixtures from fixture database and determine the positions and directions of the fixtures by using the 3D mesh models and the dental images with software $Simplant^{TM}$. Fourthly, from the geometric and/or directional information of the jawbones, the gingival regions, the teeth and the fixtures, we construct the 3D models of surgical guide stents which are crucial to perform the drilling operations with ease and accuracy. In the application phase, the dental implant information is combined with the tangible interface device to accomplish 3D dental implant simulation. The user can see and touch the 3D models related with dental implant surgery. Furthermore, the user can experience drilling paths to make holes where fixtures are implanted. A preliminary user study shows that the presented approach can be used to provide dental students with good educational contents. With future work, we expect that it can be utilized for clinical studies of dental implant surgery.