• Title/Summary/Keyword: Negative chuck bias

Search Result 1, Processing Time 0.016 seconds

Parametric study of diamond/Ti thin film deposition in microwave plasma CVD (공정변수에 따른 microwave plasma CVD 다이아몬드/Ti 박막 증착 양상 조사)

  • Cho Hyun;Kim Jin Kon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.15 no.1
    • /
    • pp.10-15
    • /
    • 2005
  • Effects of CH₄/H₂ flow rate ratio, chuck bias and microwave power on the structural properties and particle densities of diamond thin films deposited on Ti substrates in microwave plasma CVD were examined. High quality diamond thin films were deposited on Ti substrates in 2∼3 CH₄ Vol.% conditions due to the preferential formation of sp³-bonus ana selective removal of sp²-bonus in the CH₄/H₂ mixtures, and the mechanism for the formation of diamond particles on Ti was analysed. Diamond particle density increased with increasing negative chuck bias to Ti substrate due to bias-enhanced nucleation of diamond and the threshold voltage was found at ∼-50 V. With increasing microwave power the evolution from micro-crystalline graphite layer to diamond layer was observed.