• 제목/요약/키워드: Negative Pressure

검색결과 1,302건 처리시간 0.027초

음압 직각 다공질 공기베어링의 동특성에 관한 유한차분 해석 (Finite Difference Analysis of Dynamic Characteristics of Negative Pressure Rectangular Porous Gas Bearings)

  • 황평;콴폴리냐;이춘무;김은효
    • Tribology and Lubricants
    • /
    • 제22권2호
    • /
    • pp.93-98
    • /
    • 2006
  • The numerical analysis of the negative pressure porous gas bearings is presented. The pressure distribution is calculated using the finite difference method. The Reynolds equation and Darcy's equation are solved simultaneously. The air bearing stiffness and damping are evaluated using the perturbation method. Rectangular uniform grid is employed to model the bearing. The vacuum preloading is considered. The pressure in the vacuum pocket is assumed to be a constant negative pressure. The total load, stiffness, damping and flow rate are calculated fur several geometrical configurations and several values of negative pressure. It is found that too large vacuum pocket can result in negative total force.

정적 기립 자세에서 족저압 분포와 척추 정렬과의 상관관계 연구 (The Correlation of Foot Pressure with Spinal Alignment in Static Standing)

  • 임재헌;고효은
    • PNF and Movement
    • /
    • 제12권1호
    • /
    • pp.13-17
    • /
    • 2014
  • Purpose: To determine the normative data for the correlation of spinal, pelvic parameters with foot pressure in the young subjects. Methods: The subjects of this study were 39 patients in healthy adults. The Formetric-III was used to measure of spinal alignment. The pedoscan was used to measure of foot pressure. The correlation of trunk imbalance, trunk inclination, lateral deviation with foot pressure. The foot pressure measurement was consisted of maximal/mean pressure, weight contribution. Result: There was a negative correlation of trunk inclination with Max_R. There was a negative correlation of trunk inclination with Max_R. There was a positive correlation of trunk imbalance with Max_L. There was a positive correlation of lumbar lordosis with Mean_R_front, Lt. posterior weight distribution. There was a negative correlation of lumbar lordosis with Lt., Rt. in distribution There was a negative correlation of pelvic tilt with Mean_R_front, Lt. posterior weight distribution. There was a positive correlation of pelvic tilting with Rt. weight distribution, Lt. posterior weight distribution. There was a negative correlation of pelvic torsion with Lt. weight distribution, Rt. posterior weight distribution. There was a negative correlation of pelvic rotation with Lt. weight distribution, Lt. posterior weight distribution. Conclusion: The data obtained from the study may be used for future studies related to correlation of the spinal, pelvic deviation with foot pressure.

수명배수공법에 있어서 부압의 영향에 관한 실험적 연구 (The Effects of Negative Pressure on Horizontal Drain Method)

  • 김정기;김지용;정승용;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.551-558
    • /
    • 2001
  • The horizontal drain method is one of methods improving reclamation ground. This method reduces consolidation time by using drained installed horizontally, and negative pressure is applied on end of these drains by vacuum pump. But, effective negative pressure still wasn't evaluated in applying this method to reclamation ground. To estimate optimum negative pressure, soil box test that make a model the in-situ by installing horizontal drains in the center is performed pressing different vacuum pressure In the laboratory, and the variations in settlement and volume of drained water through the drains during consolidation process were measured. Also, water content with distance from drain and with depth is measured after the test.

  • PDF

Pressure Levels in Cupping Therapy: A Systemic Review

  • Kim, Ku Weon;Lee, Tae Wook;Lee, Ha Lim;An, Soo Kwang;Park, Hyo Sung;Choi, Ji Won;Lee, Byung Ryul;Yang, Gi Young
    • Journal of Acupuncture Research
    • /
    • 제37권1호
    • /
    • pp.28-34
    • /
    • 2020
  • This is a systematic review of the clinical use of cupping therapy. Four domestic databases and 2 foreign databases were searched. Studies that reported the cupping pressure used during cupping therapy were included in this study. The types of cupping, cupping site, pressure, and duration of cupping were the main parameters analyzed. A total of 27 studies, including 24 experimental studies were analyzed. There were 12 constant negative pressure (domestic) studies with a range between 60 mmHg and 600 mmHg. There were 5 maximum negative pressure (domestic) studies and the maximum negative pressure was 620 mmHg. Three studies used a maximum negative pressure of 600 mmHg. There were 4 constant negative pressure (foreign) studies with a range between 75 mmHg to 750 mmHg. There were 3 maximum negative pressure (foreign) studies with a maximum pressure of 420 mmHg. The studies differed with regards to the materials used and the amount of pressure applied. Many studies had limited information and therefore generalizability of the results in this review is limited. Further experimental studies are required to establish the correlation between cupping pressure and treatment effects so that cupping therapy can be standardised.

이동형 음압기를 적용한 긴급 전환형 임시음압격리병실의 실내 환경 측정 분석 (Measurement and Analysis of Indoor Environment in Emergency Switching Type Temporary Negative Pressure Isolation Ward that Use Portable Negative Pressure Units)

  • 이원석;이세진;김희강;여명석
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제28권4호
    • /
    • pp.89-97
    • /
    • 2022
  • Purpose: Because of the recent COVID-19 pandemic, there have been many cases of using portable negative pressure unit to convert general wards into temporary negative pressure isolation wards. The purpose of this study is to analyze the indoor environment of the switching type wards. Methods: Field measurements and experiments were conducted in a medical facility. Air volume, wind speed and pressure difference were measured in non-occupant state. Dispersion tests were performed with gas and particle matter. Results: The pressure difference between the wards and the corridor was higher than -2.5 Pa in normal situation. However, in the gas and particle dispersion tests, it was found that there were concerns about the spread through leakages in low-airtight walls or ceilings. In addition, it was confirmed that the pressure imbalance in ducts through the non-sealed diffusers could cause back flow during portable unit operation. Furthermore, when there was a pressure difference between adjacent wards planned to be at same pressure level, the possibility of the spread through the leakages was found. Implications: When using portable units for making switching type wards, it is necessary to create airtight space and seal the non-operation diffusers. In case of operating the air handling unit, T.A.B must be performed to adjust the duct balancing.

Diagnosis of Malignant Biliary Strictures: Conventional or Negative Pressure Brush Cytology?

  • Abbasi, Mohammad Reza;Mirsaeed, Seyedeh Masoumeh Ghazi;Alizadeh, Amir Houshang Mohammad
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권10호
    • /
    • pp.4563-4566
    • /
    • 2016
  • Background/Objective: The aim of this study was to perform a comparative evaluation of the yields of conventional brush cytology and brush cytology with negative pressure in the diagnosis of malignant biliary strictures. Methods: A total of 132 consecutive patients undergoing endoscopic were identified. Of these, 88.0 had brush cytology after ERCP and 44 were Brush cytology with negative pressure. Retrograde cholangiopancreatography (ERCP) including brush cytology and brush cytology with negative pressure in patients with biliary strictures between 2012-2015. Endoscopic retrograde cholangiography was performed with a standard videoduodenoscope Olympus TFJ 160-R (Olympus, Hamburg, Germany) and brush cytology with a Cook medical Double Lumen Biliary BrushTM (Cytology). Means and standard frequencies were used to calculate variables. Results: Positive results for malignancy were obtained in 22 of 88 patients (25%) by brush cytology and 31 of 44 patients (70.4 %) by brush cytology with negative pressure. Conclusions: Sensitivity of cytology sampling could be maximized by negative pressure during ERCP.

감염병전문병원의 시설 가이드라인에 관한 연구 - 운영방식과 건축계획을 중심으로 (A Study on the Establishment of Facility Guidelines for Infectious Diseases Hospitals - Focusing on Operational Methods and Architectural Planning)

  • 최광석
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제28권2호
    • /
    • pp.17-29
    • /
    • 2022
  • Purpose: In terms of efficiency and safety, this study attempted to organize data on the operation methods and architectural planning of infectious diseases hospitals. Methods: The results obtained through on-site and interview surveys with hospital officials and medical staffs at four infectious diseases hospitals under construction were summarized based on those original business plans and facility guidelines. Results: First, the operational methods to secure safety and operational efficiency were summarized for each department which are major hospital functions of infectious disease hospitals. Second, as the architectural planning, the characteristics of space and circulation of each department are summarized. For safety of medical staff, negative pressure and non-negative pressure zone have to completely separated. In addition medical staff wears PPE and enters the negative pressure zone and returns in the order of admiral, shower, and gowning in the PPE undressing room after patient treatment. In case of operational efficiency, flexible operation is required in normal and crisis situations. For example, it is important for The Ward to gradually switch to negative pressure beds in times of crisis from normal situation and the outpatient department considers the composition of negative pressure and non-negative pressure outpatient spaces that can operate in parallel even in crisis situations. Implications: Infectious disease hospitals require flexible operation and appropriate facilities for normal and crisis situations.

Taxus chinensis로부터 파클리탁셀 정제를 위한 음압 캐비테이션 아세톤-펜테인 분별침전 (Negative Pressure Cavitation Acetone-Pentane Fractional Precipitation for the Purification of Paclitaxel from Taxus chinensis)

  • 민혜수;김진현
    • Korean Chemical Engineering Research
    • /
    • 제60권4호
    • /
    • pp.544-549
    • /
    • 2022
  • 본 연구에서는 음압 캐비테이션 아세톤-펜테인 분별침전으로 Taxus chinensis로부터 파클리탁셀의 침전 효율을 획기적으로 개선하였다. 음압 -200 mmHg에서 침전할 경우 짧은 조업 시간(5분)에 대부분의 파클리탁셀을 회수(>99.9%) 할 수 있었다. 침전 속도 상수는 대조군 대비 1.512~5.073배(-50~-200 mmHg) 증가하였다. 음압으로 활성화에너지는 -3737~-6536 J/mol 감소하였으며, 이로 인해 침전 속도가 증가하였다. 또한 음압 도입으로 침전물 크기는 5.3배 감소하였으며, 파클리탁셀의 확산 계수는 7.0배 증가하였다.

A Rabbit Model of Fat Graft Recipient Site Preconditioning Using External Negative Pressure

  • Lee, Jung Woo;Han, Yea Sik;Kim, Sin Rak;Kim, Han Kyeol;Kim, Hyun;Park, Jin Hyung
    • Archives of Plastic Surgery
    • /
    • 제42권2호
    • /
    • pp.150-158
    • /
    • 2015
  • Background Fat is widely used in soft tissue augmentation. Nevertheless, it has an unpredictably high resorption rate. Clinically, external expansion with negative pressure is used to increase fat graft survival. In this study, fat graft recipient sites were preconditioned by external application of negative pressure in order to test for improvements in vascularity and fat graft survival. Methods Negative pressure was applied randomly to either the left or right dorsal ear of 20 New Zealand male white rabbits at a pressure of -125 mm Hg. The negative pressure was removed one week after the skin perfusion was measured. The skin flap at each ear was elevated, and 1 g of fat was grafted above the dorsal perichondrium. After one week, the fat weight, microvessel density, mature vessel density of the skin and fat, and amount of glycerol released were measured. Three months after the grafting, the same measurements were performed, with the exception of glycerol release. Results The fat survival rate of the experimental group ($75.4%{\pm}3.9%$) was higher than that of the control group ($53.1%{\pm}4.3%$) (P<0.001). Skin perfusion was higher in the experimental group. The glycerol release in the experimental group was significantly higher than in the control. The microvessel density of the skin and fat was significantly higher in the experimental group. Three months after the grafting, the skin and fat mature vessel density was significantly higher in the experimental groups. Conclusions Negative pressure prior to fat grafting increased the vascularity of the recipient site, and, accordingly, enhanced fat graft survival.

음압격리병실에서의 병실 문의 개폐속도에 따른 실간 압력변동 및 공기교환량에 대한 해석적 연구 (A Numerical Study on Pressure Fluctuation and Air Exchange Volume of Door Opening and Closing Speeds in Negative Pressure Isolation Room)

  • 김준영;홍진관
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제24권1호
    • /
    • pp.51-58
    • /
    • 2018
  • Purpose: In this study, through the comparison of the pressure fluctuation and air exchange volume in negative isolation room according to the type of the door and door opening/closing speeds, which is one of the main factors causing the cross contamination of the negative pressure isolation room, establishes standard operating procedures to prevent cross contamination in high risk infectious diseases and isolation room design. Methods: In this study, the air flow each of the room is analyzed using ANASYS CFX CODE for flow analysis. In addition, the grid configuration of the door is constructed by applying Immersed Solid Methods. Results: The pressure fluctuation due to the opening and closing of the hinged door was very large when the moment of the hinged door opened and closed. Especially, at the moment when the door is closed, a pressure reversal phenomenon occurs in which the pressure in the isolation room is larger than the pressure in the anteroom. On the other hand, the pressure fluctuation due to the opening and closing of the sliding door appeared only when the door was closed, but the pressure reversal phenomenon not occurred at the moment when the sliding door was closed, unlike the hinged door. As the opening and closing speed of the hinged door increases, the air exchange volume is increased. However, as the opening and closing speed of the sliding door is decreased, the air exchange volume is increased. Implications: According to the results of this study, it can be concluded that the pressure fluctuation due to the opening and closing of the hinged door is greater than the pressure fluctuation due to the opening and closing of the sliding door. In addition, it can be confirmed that the pressure reversal phenomenon, which may cause to reduce the containment effect in negative pressure isolation room, is caused by the closing of the hinged door. Therefore, it is recommended to install a sliding door to maintain a stable differential pressure in the negative isolation room. Also, as the opening and closing speed of the hinged door is slower and the opening and closing speed of the sliding door is faster, the possibility of cross contamination of the room can be reduced. It is therefore necessary to establish standard operating procedures for negative isolation room for door opening and closing speeds.