• Title/Summary/Keyword: Negative Impedance

Search Result 161, Processing Time 0.029 seconds

A $0.13-{\mu}m$ CMOS Active-RC Filter for LTE-Advanced Systems (LTE-Advanced 표준을 지원하는 $0.13-{\mu}m$ CMOS Active-RC 필터 설계)

  • Lee, Kyoung-Wook;Kim, Jong-Myeong;Park, Min-Kyung;Hyun, Seok-Bong;Jung, Jae-Ho;Kim, Chang-Wan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.396-397
    • /
    • 2011
  • This paper has proposed a multi-channel low pass filter (LPF) for LTE-Advanced systems. The proposed LPF is an active-RC 5th chebyshev topology with three cut-off frequencies of 5 MHz, 10 MHz, and 40 MHz. A 3-bit tuning circuit has been adopted to prevent variations of each cut-off frequency from process, voltage, and temperature (PVT). To achieve a high cut-off frequency of 40 MHz, an operational amplifier used in the proposed filter has employed a PMOS cross-connection load with a negative impedance. A proposed filter has been implemented in a $0.13-{\mu}m$ CMOS technology and consumes 20.2 mW with a 1.2V supply voltage.

  • PDF

A Study on the Improvement of Forward Blocking Characteristics in the Static Induction Transistor (Static Induction Transistor의 순방향 블로킹 특성 개선에 관한 연구)

  • Kim, Je-Yoon;Jung, Min-Chul;Yoon, Jee-Young;Kim, Sang-Sik;Sung, Man-Young;Kang, Ey-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.292-295
    • /
    • 2004
  • The SIT was introduced by Nishizawa. in 1972. When compared with high-voltage, power bipolar junction transistors, SITs have several advantages as power switching devices. They have a higher input impedance than do bipolar transistors and a negative temperature coefficient for the drain current that prevents thermal runaway, thus allowing the coupling of many devices in parallel to increase the current handling capability. Furthermore, the SIT is majority carrier device with a higher inherent switching speed because of the absence of minority carrier recombination, which limits the speed of bipolar transistors. This also eliminates the stringent lifetime control requirements that are essential during the fabrication of high-speed bipolar transistors. This results in a much larger safe operating area(SOA) in comparison to bipolar transistors. In this paper, vertical SIT structures are proposed to improve their electrical characteristics including the blocking voltage. Besides, the two dimensional numerical simulations were carried out using ISE-TCAD to verify the validity of the device and examine the electrical characteristics. A trench gate region oxide power SIT device is proposed to improve forward blocking characteristics. The proposed devices have superior electrical characteristics when compared to conventional device. Consequently, the fabrication of trench oxide power SIT with superior stability and electrical characteristics is simplified.

  • PDF

Active Reaction Sites and Oxygen Reduction Kinetics on $La_1_{-x}Sr_xMnO_{3+\delta}$(x=0.1-0.4)/YSZ (Yttria-Stabilized Zirconia) Electrodes for Solid Oxide Fuel Cells

  • Lee, Hee Y.;Cho, Woo S.;오승모
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.6
    • /
    • pp.661-666
    • /
    • 1998
  • Active reaction sites and electrochemical O2 reduction kinetics on La_{1-x}Sr_xMnO_{3+{\delta}} (x=0.1-0.4)/YSZ (yttria-stabilized zirconia) electrodes are investigated in the temperature range of 700-900 ℃ at $Po_2=10^{-3}$-0.21 atm. Results of the steady-state polarization measurements, which are formulated into the Butler-Volmer formalism to extract transfer coefficient values, lead us to conclude that the two-electron charge transfer step to atomically adsorbed oxygen is rate-limiting. The same conclusion is drawn from the $Po_2$-dependent ac impedance measurements, where the exponent m in the relationship of $I_o$ (exchange current density) ∝ $P_{o_{2}}^m$ is analyzed. Chemical analysis is performed on the quenched Mn perovskites to estimate their oxygen stoichiometry factors (δ) at the operating temperature (700-900 ℃). Here, the observed δ turns out to become smaller as both the Sr-doping contents (x) and the measured temperature increase. A comparison between the 8 values and cathodic activity of Mn perovskites reveals that the cathodic transfer coefficients $({\alpha}_c)$ for oxygen reduction reaction are inversely proportional to δ whereas the anodic ones $({\alpha}_a)$ show the opposite trend, reflecting that the surface oxygen vacancies on Mn perovskites actively participate in the $O_2$ reduction reaction. Among the samples of x= 0.1-0.4, the manganite with x=0.4 exhibits the smallest 8 value (even negative), and consistently this electrode shows the highest ${\alpha}_c$ and the best cathodic activity for the oxygen reduction reaction.

Body Fat Percent and Serum Lipid Level of School Children by Obesity Index (대구지역(大邱地域) 일부(一部) 국민학교(國民學校) 아동(兒童)의 비만도별(肥滿度別) 체지방(體脂肪) 비율(比率)과 혈청지질치(血淸脂質値))

  • Kim, In-Sook;Lee, Kyeong-Soo;Kang, Pock-Soo
    • Journal of the Korean Society of School Health
    • /
    • v.7 no.2
    • /
    • pp.125-133
    • /
    • 1994
  • This study was conducted to identify the relationship between body fat percent/serum lipid level and obesity index among school children. The study subjects were 277 boys and 266 girls aged between 10 and 11 years old in a selected elementary school in Taegu City. The survey was conducted for the period of two months from May 1 to June 30, 1993. A $R{\ddot{o}}hrer$index(weight/height3) was calculated for each individual as a measure of obesity. Three groups were classified as underweight($R{\ddot{o}}hrer$ index < 109), normal($109{\leq}$ $R{\ddot{o}}hrer$ index < 140), and overweight ($R{\ddot{o}}hrer$ index ${\geq}140$). As for the body fat percent, fat weight, lean body mass were measured by impedance fat, meter(Model SIF-891). Serum total cholesterol. high-density lipoprotein, and triglyceride were measured by automated clinical chemistry analyzer(Astra system). Obesity was found 18.1% in boys and 14.7% in girls. Body weight, fat percent, fat weight, and lean body mass were significantly different among three groups classified by $R{\ddot{o}}hrer$ index in both sexes. Serum total cholesterol, triglyceride, atherogenic index and T-CHO/HDL ratio were also significantly different among three groups in both sexes. Serum total cholesterol, low-density lipoprotein, trigylceride, atherogenic index of boys were positively correlated with height, weight. $R{\ddot{o}}hrer$ index, fat weight, lean body mass, and triglyceride. The negative correlation was found in high-density lipoprotein against height, weight, Rohrer index, fat percent, fat weight, lean body mass. Triglyceride and atherogenic index of the girls were positively correlated with height, weight, $R{\ddot{o}}hrer$ index, fat percent, fat weight, lean body mass. The negative correlation was found in high-density lipoprotein against height, weight, $R{\ddot{o}}hrer$ index, fat percent, fat weight, lean body mass. These findings suggest that the prevention of obesity and hyperlipidemia among school children is very important. Thus adoption of healthy life-style is strongly recommended in school health programs in order to prevent the obesity and hyperlipidemia.

  • PDF

A Study on Nutrient Intakes, Body Composition and Physical Fitness in Gifted Athletic Boys -Focused on Gifted Athletic Boys in Busan, Ulsan and Gyeongsangnam-do- (남자체육영재 선발자의 영양섭취, 신체조성 및 체력에 관한 연구 -부산, 울산, 경남지역 체육영재 선발자를 중심으로-)

  • Seo, Dae-Yun;Shin, Sang-Keun;Baek, Yeong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.7
    • /
    • pp.966-974
    • /
    • 2010
  • The aim of this study was to examine characteristics between nutrient intakes, body composition and physical fitness in gifted athletic boys. The subjects were conducted in 50 boys aged 9~12 years living in Busan, Ulsan and Gyeongsangnam-do, Korea. Dietary intake information was collected from participants using 3-day food recorded and body composition was measured by bioelectrical impedance analysis, and their anthropometric parameters were measured. Swimming group's daily energy intakes were significantly higher compared to those of other groups. Athletics and swimming groups were significantly taller than gymnastics. Swimming group was significantly higher than gymnastics group in weight, fat mass, body fat percent and lean body mass. Athletics and swimming groups were significantly longer than gymnastics group in sit and ball throwing. Swimming group was significantly better than other groups in sit up, and athletics group was significantly faster than gymnastics group in 50 m run. In correlation result for nutrient intake and body composition: 1) Body weight shows positive correlation with protein, phosphorus, sodium, vitamin $B_1$, C and niacin. BMI shows positive correlation with sodium and niacin. Fat mass shows positive correlation with niacin and folate. Body fat% shows positive correlation with vitamin C, E, niacin and folate. LBM shows positive correlation with all elements except lipid, calcium, vitamin A, C, E and folate. In correlation result for nutrient intake and physical fitness: 2) Push up shows positive correlation with iron and vitamin C. Sit and throw ball shows positive correlation with the events except lipid, fiber, vitamin A, E and folate. Sit up shows positive correlation with vitamin $B_1$. Half squat shows positive correlation with iron. Standing long jump shows positive correlation with total energy, lipid, and vitamin A, B and $B_2$. Long run shows negative correlation with protein, carbohydrate, fiber, phosphorus, iron, sodium and zinc. Side step shows positive correlation with niacin. Sit and reach shows negative correlation with total energy, carbohydrate, phosphorus, sodium, zinc and vitamin $B_2$. In correlation result for body composition and physical fitness: 3) Sit and throw ball shows positive correlation with body weight, BMI, fat mass, body fat% and LBM. Standing long jump shows positive correlation with LBM. But long run and 50 m run shows negative correlation with body weight and LBM.

Plasma D-dimer Determination in the Diagnosis of Pulmonary Embolism (폐색전증의 진단에 있어 혈청 D-dimer 측정의 진단적 가치)

  • Lim, Chae-Man;Kim, Hong-Kyu;Choi, Kang-Hyun;Lee, Sand-Do;Koh, Youn-Suck;Kim, Woo-Sung;Jang, Jae-Suck;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.1
    • /
    • pp.69-74
    • /
    • 1996
  • Background: The diagnosis of pulmonary embolism (PE) based on clinical findings is often elusive and therefore requires confirmative diagnostic method. Pulmonary angiography, though the gold standard for the diagnosis of pulmonary embolism, is an invasive method and requires trained personnel and special equipment. Lung V/Q scan, on the other hand, is a noninvasive method but the diagnostic specificity and sensitivity arc not satisfactory in case that the results are either intermediate or low probability scan. Plasma D-dimer is generated when a thrombus is fibrinolysed by plasmin and is known to be increased in various thrombotic disorders. The aim of this study was to investigate the value of the determination of plasma D-dimer level in the diagnosis of pulmonary embolism. Methods: Pulmonary angiography was performed in 17 patients who were clinically suspected to have pulmonary embolism. 9 patients(PE, $56{\pm}13.4$ yrs, M:F=8:1) were diagnosed to have pulmonary embolism by pulmonary angiography. The control group were the 8 patients with negative pulmonary angiography and 13 orthopedic patients with no evidence of pulmonary embolism on scintigraphic and impedance plethysmographic studies(n=21) (non-PE, $54.5{\pm}11.1$ yrs, M:F=11:10). Plasma D-dimer was measured by latex agglutination method in study subjects and the results were analyzed according to the presence or absence of pulmonary embolism. Results: 1) The increased level of plasma D-dimer was more frequently observed in the patients with pulmonary embolism than in the controls(>0.5 mg/L, 8 in PE, 10 in non-PE; <0.5 mg/L, 1 in PE, 11 in non-PE, p=0.049). 2) The diagnostic value of plasma D-dimer level higher than 0.5 mg/L were as follows: sensitivity 88.9%(8/9), specificity 52.4%(11/21), positive predictive value 44.4%(8/18), and negative predictive value 91.7%(11/12). Conclusion: Plasma D-dimer determination showed high sensitivity and negative predictive value in the diagnosis of pulmonary embolism and is therefore thought to be useful in excluding the possibility of pulmonary embolism.

  • PDF

A Design of Transceiver for 13.56MHz RFID Reader using the Peak Detector with Automatic Reference Voltage Generator (자동 기준전압 생성 피크 검출기를 이용한 13.56 MHz RFID 리더기용 송수신기 설계)

  • Kim, Ju-Seong;Min, Kyung-Jik;Nam, Chul;Hurh, Djyoung;Lee, Kang-Yun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.3
    • /
    • pp.28-34
    • /
    • 2010
  • In this paper, the transceiver for RFID reader using 13.56MHz as a carrier frequency and meeting International Standard ISO 14443 type A, 14443 type B and 15693 is presented. The receiver is composed of envelope detector, VGA(Variable Gain Amplifier), filter, comparator to recovery the received signal. The proposed automatic reference voltage generator, positive peak detector, negative peak detector, and data slicer circuit can adjust the decision level of reference voltage over the received signal amplitudes. The transmitter is designed to drive high voltage and current to meet the 15693 specification. By using inductor loading circuit which can swing more than power supply and drive large current even under low impedance condition, it can control modulation rate from 30 percent to 5 percent, 100 perccnt and drive the output currents from 5 mA to 240 mA depending on standards. The 13.56 MHZ RFID reader is implemented in $0.18\;{\mu}m$ CM08 technology at 3.3V single supply. The chip area excluding pads is $1.5mm\;{\times}\;1.5mm$.

The Effect of Body Composition on Pulmonary Function

  • Park, Jung-Eun;Chung, Jin-Hong;Lee, Kwan-Ho;Shin, Kyeong-Cheol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.5
    • /
    • pp.433-440
    • /
    • 2012
  • Background: The pulmonary function test is the most basic test method to diagnosis lung disease. The purpose of this study was to research the correlation of the body mass index (BMI), the fat percentage of the body mass (fat%), the muscle mass, the fat-free mass (FFM) and the fat-free mass index (FFMI), waist-hip ratio (WHR), on the forced expiratory volume curve. Methods: Between March and April 2009, a total of 291 subjects were enrolled. There were 152 men and 139 female (mean age, $46.3{\pm}9.92$ years), and they were measured for the following: forced vital capacity (FVC), forced expiratory volume at 1 second ($FEV_1$), and forced expiratory flow during the middle half of the FVC ($FEF_{25-75}$) from the forced expiratory volume curve by the spirometry, and the body composition by the bioelectrical impedance method. Correlation and a multiple linear regression, between the body composition and pulmonary function, were used. Results: BMI and fat% had no correlation with FVC, $FEV_1$ in male, but FFMI showed a positive correlation. In contrast, BMI and fat% had correlation with FVC, $FEV_1$ in female, but FFMI showed no correlation. Both male and female, FVC and $FEV_1$ had a negative correlation with WHR (male, FVC r=-0.327, $FEV_1$ r=-0.36; p<0.05; female, FVC r=-0.175, $FEV_1$ r=-0.213; p<0.05). In a multiple linear regression of considering the body composition of the total group, FVC explained FFM, BMI, and FFMI in order ($r^2$=0.579, 0.657, 0.663). $FEV_1$ was explained only fat% ($r^2$=0.011), and $FEF_{25-75}$ was explained muscle mass, FFMI, FFM ($r^2$=0.126, 0.138, 0.148). Conclusion: The BMI, fat%, muscle mass, FFM, FFMI, WHR have significant association with pulmonary function but $r^2$ (adjusted coefficient of determination) were not high enough for explaining lung function.

The Effect of Passing Aged Years to the Polarization Characteristics of Embedded Steel Bar of Mortar Specimen(W/C:0.4) (몰타르 시험편(W/C:0.4) 내부철근의 분극특성에 미치는 재령년수의 영향)

  • Moon, Kyung-Man;Won, Jong-Pil;Park, Dong-Hyun;Lee, Sung-Yul;Jeong, Jin-A;Lee, Myeong-Hoon;Baek, Tae-Sil
    • Corrosion Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.20-27
    • /
    • 2014
  • The structures of reinforced concrete has been extensively increased with rapid development of industrial society. Futhermore, these reinforced concretes are easy to expose to severe corrosive environments such as sea water, contaminated water, acid rain and seashore etc.. Thus, corrosion problem of inner steel bar embedded in concrete is very important in terms of safety and economical point of view. In this study, multiple mortar test specimen(W/C:0.4) with six types having different cover thickness each other was prepared and was immerged in seawater solution for five years to evaluate the effect of cover thickness and immersion years to corrosion property of embedded steel bar. And the polarization characteristics of these embedded steel bars was investigated using electrochemical methods such as measuring corrosion potential, cathodic polarization curve, and cyclic voltammogram. At the beginning of immersion, the corrosion potentials exhibited increasingly nobler values with increasing cover thickness. However, after immersed for 5 years, the thicker cover of thickness, the corrosion potentials shifted in the negative direction, and the relationship between corrosion potential and cover thickness was not in good agreement with each other. Therefore, it is considered that the thinner cover of thickness, corrosive products deposited on the surface of the embedded steel bar plays the role as a resistance polarization which is resulted in decreasing the corrosion rate as well as shifting the corrosion potential in the positive direction. As a result, it seemed that the evaluation which corrosion possibility of the reinforced steel would be estimated by only measuring the corrosion potential may not be a completely desirable method. Therefore, it is suggested that we should take into account various parameters, including cover thickness, passed aged years as well as corrosion potential for more accurate assessment of corrosion possibility of reinforced steel which is exposed to partially or fully in marine environment for long years.

A 0.31pJ/conv-step 13b 100MS/s 0.13um CMOS ADC for 3G Communication Systems (3G 통신 시스템 응용을 위한 0.31pJ/conv-step의 13비트 100MS/s 0.13um CMOS A/D 변환기)

  • Lee, Dong-Suk;Lee, Myung-Hwan;Kwon, Yi-Gi;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.3
    • /
    • pp.75-85
    • /
    • 2009
  • This work proposes a 13b 100MS/s 0.13um CMOS ADC for 3G communication systems such as two-carrier W-CDMA applications simultaneously requiring high resolution, low power, and small size at high speed. The proposed ADC employs a four-step pipeline architecture to optimize power consumption and chip area at the target resolution and sampling rate. Area-efficient high-speed high-resolution gate-bootstrapping circuits are implemented at the sampling switches of the input SHA to maintain signal linearity over the Nyquist rate even at a 1.0V supply operation. The cascode compensation technique on a low-impedance path implemented in the two-stage amplifiers of the SHA and MDAC simultaneously achieves the required operation speed and phase margin with more reduced power consumption than the Miller compensation technique. Low-glitch dynamic latches in sub-ranging flash ADCs reduce kickback-noise referred to the differential input stage of the comparator by isolating the input stage from output nodes to improve system accuracy. The proposed low-noise current and voltage references based on triple negative T.C. circuits are employed on chip with optional off-chip reference voltages. The prototype ADC in a 0.13um 1P8M CMOS technology demonstrates the measured DNL and INL within 0.70LSB and 1.79LSB, respectively. The ADC shows a maximum SNDR of 64.5dB and a maximum SFDR of 78.0dB at 100MS/s, respectively. The ABC with an active die area of $1.22mm^2$ consumes 42.0mW at 100MS/s and a 1.2V supply, corresponding to a FOM of 0.31pJ/conv-step.