• Title/Summary/Keyword: Negative Hydraulic Head

Search Result 7, Processing Time 0.022 seconds

Investigation into circulation of ground water by air sparging (Air sparging에 의한 지하수 순환에 관한 연구)

  • 이준희;강구영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.232-235
    • /
    • 1998
  • Air sparging system is a kind of in-situ bioremediation method in the contaminated ground water. When Air sparging, the both of water circulation and oxygen transfer happend in the same time. The hydraulic differential head is zero at the middle height of well, is negative below the height and is possitive above the height. Hydroraulic head gradient is proportioned to air superficial velocity in the well. But over 24m/min of the superficial velocity, the hydraulic head gradient increase little.

  • PDF

Stochastic Simulation of Groundwater Flow in Heterogeneous Formations: a Virtual Setting via Realizations of Random Field (불균질지층내 지하수 유동의 확률론적 분석 : 무작위성 분포 재생을 통한 가상적 수리시험)

  • Lee, Kang-Kun
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.1 no.2
    • /
    • pp.90-99
    • /
    • 1994
  • Heterogeneous hydraulic conductivity in a flow domain is generated under the assumption that it is a random variable with a lognormal, spatially-correlated distribution. The hydraulic head and the conductivity in a groundwater flow system are represented as a stochastic process. The method of Monte Carlo Simulation (MCS) and the finite element method (FEM) are used to determine the statistics of the head and the logconductivity. The second moments of the head and the logconductivity indicate that the cross-covariance of the logconductivity with the head has characteristic distribution patterns depending on the properties of sources, boundary conditions, head gradients, and correlation scales. The negative cross-correlation outlines a weak-response zone where the flow system is weakly responding to a stress change in the flow domain. The stochastic approach has a potential to quantitatively delineate the zone of influence through computations of the cross-covariance distribution.

  • PDF

Relationship between In-situ Hydraulic Conductivity and Van Genuchten Parameters of Unsaturated Fractured Hornfels (불포화 균열 혼펠스의 현장 수리전도도와 반 게누텐 매개변수의 상관성)

  • Cheong, Jae-Yeol;Cho, HyunJin;Kim, Soo-Gin;Ok, Soonil;Kim, Kue-Young;Hamm, Se-Yeong
    • The Journal of Engineering Geology
    • /
    • v.30 no.2
    • /
    • pp.147-160
    • /
    • 2020
  • Unsaturated hydraulic conductivity of near-surface unconsolidated layers depends on the physical properties and water content of the unconsolidated layers. So far, many studies have been conducted on the unsaturated hydraulic conductivity of near-surface unconsolidated layers. However, researches on hydraulic conductivity of unsaturated fractured rocks have been relatively rare. In relation to the construction of a low/intermediate level radioactive waste surface-disposal facility, this study compared and analyzed van Genuchten parameters (α, n) in the laboratory and the hydraulic conductivity obtained in field tests for fractured hornfels at a radioactive-waste disposal site of Korea. The relationship between the field hydraulic conductivity and van Genuchten parameters using data from the ten depth intervals of three boreholes resulted in that the correlation coefficient (R) between the hydraulic conductivity and the van Genuchten parameter α was 0.7607, showing positive correlation whereas the R between the hydraulic conductivity and the van Genuchten shape-defining parameter n was -0.8720, showing negative correlation. Hence, this study confirmed the relationship between the field hydraulic conductivity and the van Genuchten unsaturated functions for the unsaturated fractured hornfels.

A Study on the Performance of Vacuum Preloading with Vertical Drains (수직배수를 병행한 진공압밀공법 적용시의 연약지반 거동 예측 연구)

  • Park, Jung-Bae;Kim, Seung-U;Kim, Yu-Seok
    • Geotechnical Engineering
    • /
    • v.12 no.5
    • /
    • pp.79-88
    • /
    • 1996
  • In this study, prediction of soil behavior under vacuum preloading with vertical drain is explored on the basis of numerical models and toe results were compared with field measurements. Reasonable prediction of the time rate of settlements and pore pressure dissipation under vacuum preloading is the maj or concern. The conventional method for vatsuum preloading is based on modeling vacuum preloading as surcharge loading for the consolidation analysis. However, this modeling may violate the real behavior of soils under vacuum loading since the total stress in the analysis varies due to the modeled surcharge loading whereas in'.situ total stress of soils under vacuum loading is constant. In this study a new method is suggested. Instead of modeling vacuum loading as surcharge loading, negative hydraulic head is applied at the surface drain boundary to simulate the vacuum preloading. Comparisons of predictions and field measurements of soil behavior under vatsuum preloading are presented and the usefulness of the new modeling technique is demonstrated.

  • PDF

Experiment Study on Field Applicability of Siphon as a Intake Facility of Agricultural Reservoir for Disaster Prevention (재해대비 농업용저수지 취수시설로서 사이폰의 현장적용성에 관한 실험적 연구)

  • Yang, Young Jin;Lee, Tae Ho;Oh, Sue Hoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.2
    • /
    • pp.103-110
    • /
    • 2018
  • Most of the intake facilities of small agricultural reservoirs are conduits and they are regarded as serious defects due to the structural weakness that penetrates the body of the dam, and countermeasures are needed. This study suggests the application method of siphon type water intake facility by hydraulic model test and physical scale model test of siphon type water intake facility which has high safety and easy maintenance. Experimental results show that sufficient flow rate can be secured for the purpose of intaking water according to the differential head between the reservoir and the discharge part, and the flow rate can be controlled by the valve. The negative pressure was -31.5 kPa, and vibration and noise did not occur during the operation of the siphon. The maximum flow velocity in the discharge outlet was 1.11 m/s which meets the criterion for irrigation canals. Therefore, scour risk would be very low. As a result of the inflow distribution experiment, even if the inflow part is separated by only about 0.8 m, the flow velocity is remarkably decreased, so that the clogging by debris would not appear. When the pump was operated only once for the first time and the inside of the siphon was filled with water, continuous operation was possible by only valve operation. The results of this study are expected to be used for the design guidelines of the water intake facilities and improve safety and maintenance convenience of agricultural reservoirs.

Relation between Hydraulic Properties and Growth of Rice in Poorly Drained Paddy Soils (습답(濕畓)에서 수리특성(水理特性)과 수도생육(水稻生育)과의 관계(關係))

  • Park, Chang-Seo;Im, Jeong-Nam;Ryu, Kwan-Sik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.14 no.4
    • /
    • pp.185-189
    • /
    • 1982
  • Piezometric head, soil temperature, and redox potential were investigated to identify the factors causing the poor growth of rice in poorly drained paddy soils. 1. In local valleys the variegated piezometric head difference was observed place to place and resulted in uneven growth of rice while nearly uniform head difference was observed in alluvial plains. 2. Direction of water flow in paddy soils seemed to develop a significant difference in soil temperature and plant growth. 3. Negative correlation between piezometric head and rice growth and/or yiled was observed, and yield was decreased with the increase of upward flow of water. 4. There was a positive correlation between soil temperature and rice growth and/or yield. Cold temperature below $20^{\circ}C$ retarded significantly the plant growth and rice plant, at $16^{\circ}C$, could not grow.

  • PDF

Evaluation of Subsystem Importance Index considering Effective Supply in Water Distribution Systems (유효유량 개념을 도입한 상수관망 Subsystem 별 중요도 산정)

  • Seo, Min-Yeol;Yoo, Do-Guen;Kim, Joong-Hoon;Jun, Hwan-Don;Chung, Gun-Hui
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.6
    • /
    • pp.133-141
    • /
    • 2009
  • The main objective of water distribution system is to supply enough water to users with proper pressure. Hydraulic analysis of water distribution system can be divided into Demand Driven Analysis (DDA) and Pressure Driven Analysis (PDA). Demand-driven analysis can give unrealistic results such as negative pressures in nodes due to the assumption that nodal demands are always satisfied. Pressure-driven analysis which is often used as an alternative requires a Head-Outflow Relationship (HOR) to estimate the amount of possible water supply at a certain level of pressure. However, the lack of data causes difficulty to develop the relationship. In this study, effective supply, which is the possible amount of supply while meeting the pressure requirement in nodes, is proposed to estimate the serviceability and user's convenience of the network. The effective supply is used to calculate Subsystem Importance Index (SII) which indicates the effect of isolating a subsystem on the entire network. Harmony Search, a stochastic search algorithm, is linked with EPANET to maximize the effective supply. The proposed approach is applied in example networks to evaluate the capability of the network when a subsystem is isolated, which can also be utilized to prioritize the rehabilitation order or evaluate reliability of the network.