• 제목/요약/키워드: Negative Electrode

검색결과 428건 처리시간 0.023초

수용액중 아연 덴드라이트의 성장 반응에 미치는 전해질 농도의 영향 (Effects of Electrolyte Concentration on Growth of Dendritic Zinc in Aqueous Solutions)

  • 신경희;정규남;윤수근;연순화;심준목;전재덕;진창수;김양수;박경수;정순기
    • 한국수소및신에너지학회논문집
    • /
    • 제23권4호
    • /
    • pp.390-396
    • /
    • 2012
  • In order to understand the nature of dendritic zinc growth, electrochemical zinc redox reaction on nickel plate was investigated in aqueous solutions containing different concentrations, 0.2, 0.1 and 0.02 $mol{\cdot}dm^{-3}$ (M), of zinc sulfate ($ZnSO_4$) or zinc chloride ($ZnCl_2$). Zinc ion was efficiently reduced and oxidized on nickel in the high-concentration (0.2 M) solution, whereas relatively poor efficiency was obtained from the other low-concentration solutions (0,1 and 0.02 M). Cyclic voltammetry (CV) analysis revealed that the 0.2 M electrolyte solution decomposes at more positive potentials than the 0.1 and the 0.02 M solutions. These results suggested that the concentration of electrolyte solution and anion would be an important factor that suppresses the reaction of the zinc dendrite formation. Scanning Electron Microscopy (SEM) data revealed that the shape of dendritic zinc and its growing behavior were also influenced by electrolyte concentration.

크라운 에테르첨가에 의한 할로겐화 알킬암모늄의 전기화학적 분석 (Electrochemical Analysis of Alkylammonium Halides by Addition of Crown Ether)

  • 박종민;박명용
    • 대한화학회지
    • /
    • 제33권1호
    • /
    • pp.37-45
    • /
    • 1989
  • 알킬암모늄의 propylene carbonate용액에 크라운 에테르를 첨가하였을때와 첨가하지 않았을 때의 전기화학적 거동을 펄스차이 전압전류법과 순환 전압전류법으로 조사하였다. 그 결과 환원전극 반응은 준가역적 반응임을 알 수 있었고, 환원파의 봉우리가 겹침으로 개별정량이 어려운 이들 이성체 혼합물에 크라운 에테르를 첨가하여 착물화 능력의 차이를 이용하여 혼합물의 각성분을 개별 정량하였다. 즉 $EtNH^{+}_{3}Cl^-$(1.6mM)와 $Me_2NH^{+}_{2}Cl^-$혼합물에 18-crown-6(20mM)를 첨가하였을 때 $Me_2NH^{+}_{2}Cl^-$의 농도가 $EtNH^{+}_{3}Cl^-$$\frac{1}{2}$이하(0.8mM이하)에서 펄스차이 전압전류법에 의한 봉우리의 분리가 가능하였고, 착물화에 의한 봉우리의 음전위 이동은 $EtNH^{+}_{3}Cl^-$가 0.53V, $Me_2NH^{+}_{2}Cl^-$가 0.37V이었다. 이때, $Me_2NH^{+}_{2}Cl^-$의 농도범위 0.6∼0.8mM에서 봉우리 전류(봉우리 전위, -1.06V vs. Ag/AgCl에서 $Me_2NH^{+}_{2}$${\cdot}$CR의 환원)와 농도 사이에 직선적 비례관계가 성립하여, $EtNH^{+}_{3}Cl^-$의 공존하에서 $Me_2NH^{+}_{2}Cl^-$를 정량할 수 있었다. 또한 순환전압전류법에서 $EtNH^{+}_{3}Cl^-$의 농도가 $Me_2NH^{+}_{2}Cl^-$(0.5mM)보다 과량인 경우, $EtNH^{+}_{3}Cl^-$ 농도범위 0.5∼2.5mM에서 $Me_2NH^{+}_{2}Cl^-$의 공존하에서 $EtNH^{+}_{3}Cl^-$의 정량이 가능하였다.

  • PDF

뇌파를 이용한 열차 최적의 HUD위치 평가 (Evaluation for Optimal HUD Location on a Train Using EEG)

  • 왕창원;김용규;민세동
    • 한국통신학회논문지
    • /
    • 제39C권11호
    • /
    • pp.985-993
    • /
    • 2014
  • 본 논문은 뇌파와 ANOVA를 이용하여 생체신호와 통계 분석기반의 상관관계를 통해 열차 최적의 HUD위치를 평가하는 새로운 방법을 제안하였다. 본 연구에서는 최적의 HUD위치를 평가하기 위해 총 2가지 실험을 진행하였다. 첫 번째 연구실에서 각각 다른 여섯 위치(좌측 상단 및 하단, 중앙 상단 및 하단, 우측 상단 및 하단)에 시각자극을 제시하였고, 이미지는 $235{\times}197cm2$ 크기의 스크린에 30초동안 나타냈다. 두 번째 HUD 이미지는 철도시뮬레이터에서 각각 다른 세 군데에 구성하였고, 이미지는 스크린에 30초 동안 나타냈다. 뇌파는 정서적 안정성을 평가하기 위해 알파파와 베타파를 이용하였고, 10-20전극 배치법에 따라 Fp1, Fp2, F7, F8채널에서 측정하였다. 연구실 실험 결과, F7채널 베타파에서 유의확률 0.006으로 통계적으로 유의하게 나타났고, 알파파와 베타파 간 음의 상관관계(r=-0.190)가 있는 것으로 나타났다. 또한 스크린의 좌측 상단, 중앙 하단 위치가 우측 하단 위치에 비해 베타파가 낮게 나타났다. 철도 시뮬레이터 실험 결과, Fp1베타파가 유의확률 0.033으로 통계적으로 유의하게 나타났고, 중앙보다는 좌측일 때 베타파가 낮게 나타났다. 본 연구의 결과는 알파 파와 베타 파 사이의 상관 관계를 통해 최적의 HUD 위치의 평가에 대한 도움이 될 것으로 생각된다.

전기자극과 VOG(Videooculograph)를 이용한 정상인의 전정 안반사 측정 (Measurement of Vestibular Ocular Reflex in Normal Subjects Using Galvanic Stimulator and Videooculograph)

  • 김수찬;정운교;남기창;이원상;김영하;김덕원
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권6호
    • /
    • pp.487-496
    • /
    • 2001
  • 본 연구에서는 PIC(마이크로 컨트롤러)를 이용하여 전정계 기능 검사를 할 수 있도록 앙극 (bipolar) 자극이 가능한 정전류 자극기를 제작하였다. 정전류원이 구동할 수 있는 최대 부하와 최대 전류는 각각 3$k\Omega$. 5mA로 하였다. 그리고 자극 패턴은 직류. 정현파, 혹은 펄스파가 가능하도록 제작하였다. 정상인 20명을 대상으로 전기 자극 방법에 따른 안구 운동을 영상 안구운동 검사기(videooculograph; VOG)를 이용하여 분석하였다. 자극 패턴은 직류. 자극 시간은 30초로 하여. 전류의 세기에 대한 안진 반응을 살펴보기 위해 각 피검자마다 자극 전류가 0.75. 1, 2. 3mA인 경우에 대하여 실험하였다 자극 전류의 세기가 2mA 이상일 때는 검사 대상자 모두에게서 안진이 발생하였다 전류의 세기를 0.75에서 3mA로 증가시켰을 때. 느린 성분의 안구운동 속도의 평균은 1.1에서 4.8 deg/sec로 증가하였고. 안진의 평균 횟수 또한 17회에서 48회로 증가하였다. 전기 자극으로 인한 빠른 성분의 안구운동은 일관되게 음 자극을 가하는 전극이 있는 방향으로 나타났으며 좌우 반응의 타이를 나타내는 비대칭도는 전류가 증가할수록 감소하였다. 본 연구는 전기 자극을 이용한 전정 기능 평가와 전정 안반사의 생리기전 연구의 기초 자료로 활용할 수 있을 것으로 사료된다.

  • PDF

청년기·노년기 성인의 신체활동 참여가 정서인지에 미치는 영향 (The Influence of Participation of Physical Activity in Adolescence and Senescence Adults on Affective Cognition)

  • 윤병탁;류광민;김진구
    • 감성과학
    • /
    • 제20권4호
    • /
    • pp.41-54
    • /
    • 2017
  • 신체활동은 노화로 의한 인지기능 저하에 긍정적 영향을 미친다. 하지만 신체활동 참여가 정서인지기능에 미치는 영향을 과학적으로 밝혀 낸 연구는 드물다. 따라서 본 연구의 목적은 청년기와 노년기 성인의 정서인지 기능에 신체활동 참여가 어떠한 영향을 미치는지를 뇌 과학적으로 연구하는 것이다. 연구의 피험자는 D 광역시 성인 남성 60명으로 선정하였으며, 청년 운동 집단(25~35살), 청년 비 운동 집단(26~35살), 노년 운동 집단(60~70살), 노년 비 운동집단(60~70살) 4개의 집단으로 구성하였다. 실험도구는 EEG 측정 장비와 국제정서사진체계(International Affective Picture System: IAPS)를 사용하였다. 본 연구의 실험과제는 사진으로 제시하는 세 가지 정서자극(긍정적, 중립, 부정적)에 적합한 버튼을 눌러 정서적인지 검사를 실시하였다. EEG 측정은 8개(Fp1, Fp2, Fz, C3, C4, Cz, T3, T4)의 영역을 측정하였다. 통계처리는 4(집단)${\times}$3(자극)${\times}$8(영역)에 대한 삼원분산분석을 실시하였다. 결과: 본 연구 결과, 반응시간과 반응정확률 그리고 P3 잠재기는 집단간 주효과가 나타났다. 그리고 P3 진폭은 집단과 자극간 상호작용이 나타났다. 결론: 신체활동은 청년층과 노년층의 정서적 인지기능에 긍정적인 영향을 미치는 것으로 나타났다.

Integrated RT-PCR Microdevice with an Immunochromatographic Strip for Colorimetric Influenza H1N1 virus detection

  • Heo, Hyun Young;Kim, Yong Tae;Chen, Yuchao;Choi, Jong Young;Seo, Tae Seok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.273-273
    • /
    • 2013
  • Recently, Point-of-care (POC) testing microdevices enable to do the patient monitoring, drug screening, pathogen detection in the outside of hospital. Immunochromatographic strip (ICS) is one of the diagnostic technologies which are widely applied to POC detection. Relatively low cost, simplicity to use, easy interpretations of the diagnostic results and high stability under any circumstances are representative advantages of POC diagnosis. It would provide colorimetric results more conveniently, if the genetic analysis microsystem incorporates the ICS as a detector part. In this work, we develop a reverse transcriptase-polymerase chain reaction (RT-PCR) microfluidic device integrated with a ROSGENE strip for colorimetric influenza H1N1 virus detection. The integrated RT-PCR- ROSGENE device is consist of four functional units which are a pneumatic micropump for sample loading, 2 ${\mu}L$ volume RT-PCR chamber for target gene amplification, a resistance temperature detector (RTD) electrode for temperature control, and a ROSGENE strip for target gene detection. The device was fabricated by combining four layers: First wafer is for RTD microfabrication, the second wafer is for PCR chamber at the bottom and micropump channel on the top, the third is the monolithic PDMS, and the fourth is the manifold for micropump operation. The RT-PCR was performed with subtype specific forward and reverse primers which were labeled with Texas-red, serving as a fluorescent hapten. A biotin-dUTP was used to insert biotin moieties in the PCR amplicons, during the RT-PCR. The RT-PCR amplicons were loaded in the sample application area, and they were conjugated with Au NP-labeled hapten-antibody. The test band embedded with streptavidins captures the biotin labeled amplicons and we can see violet colorimetric signals if the target gene was amplified with the control line. The off-chip RT-PCR amplicons of the influenza H1N1 virus were analyzed with a ROSGENE strip in comparison with an agarose gel electrophoresis. The intensities of test line was proportional to the template quantity and the detection sensitivity of the strip was better than that of the agarose gel. The test band of the ROSGENE strip could be observed with only 10 copies of a RNA template by the naked eyes. For the on-chip RT-PCR-ROSGENE experiments, a RT-PCR cocktail was injected into the chamber from the inlet reservoir to the waste outlet by the micro-pump actuation. After filling without bubbles inside the chamber, a RT-PCR thermal cycling was executed for 2 hours with all the microvalves closed to isolate the PCR chamber. After thermal cycling, the RT-PCR product was delivered to the attached ROSGENE strip through the outlet reservoir. After dropping 40 ${\mu}L$ of an eluant buffer at the end of the strip, the violet test line was detected as a H1N1 virus indicator, while the negative experiment only revealed a control line and while the positive experiment a control and a test line was appeared.

  • PDF

푸리에 변환과 웨이브렛 분석을 통한 주의력결핍 ${\cdot}$ 과잉운동장애 아동과 정상 아동의 사건관련전위 비교 연구 (A COMPARATIVE STUDY UPON EVENT-RELATED POTENTIALS OF THE PATIENTS WITH ADHD AND NORMAL CHILDREN USING FOURIER TRANSFORMATION AND WAVELET ANALYSIS)

  • 박진형;김희찬;조수철;신성웅
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • 제12권1호
    • /
    • pp.25-50
    • /
    • 2001
  • 주의력결핍 ${\cdot}$ 과잉운동장애 아동과 정상 아동의 청각적 집중 과정의 차이를 비교하기 위해 13명의 남자 환자와 8명의 정상 남자아이에게 청각적 주의집중 과제를 제시하고 사건관련전위를 푸리에 변환과 웨이브렛 분석법으로 비교 조사하였다. 각 군 아동의 표준자극과 표적자극에 대한 사건관련전위 파형을 푸리에 변환을 통해 주파수 차원에서 서로 비교하였고, 각 군 안에서 표적자극과 표준자극을 주었을 때의 진폭을 비교하였다. 표준자극에 대해서는 거의 대부분의 주파수와 전극 위치에서 주의력결핍 ${\cdot}$ 과잉운동장애 아동이 정상아동보다 의미 있게 높은 전압을 나타내었다. 반면 표적자극에 대해서는 주의력결핍 ${\cdot}$ 과잉운동장애 아동이 정상 아동보다 더 높은 전압을 보이는 경우가 의미 있게 감소하였고 정상 아동이 주의력결핍 ${\cdot}$ 과잉운동장애 아동보다 큰 진폭을 나타내는 경우는 의미 있게 증가하였다. 이런 결과는 주의집중을 반영하는 Nd파형의 푸리에 변환 결과에서도 나타났다. 즉 주의력결핍 ${\cdot}$ 과잉운동장애 아동은 무시해야 하는 자극에 대해서는 정상 아동보다 지나치게 강한 반응을 보이지만 정작 과제를 수행해야 하는 자극에 대해서는 정상 아동보다 더 약한반응을 보이는 경향을 보였다. 주의력결핍 ${\cdot}$ 과잉운동장애 아동은 정상 아동 보다 표적자극에 의한 진폭 증가를 보인 전극과 주파수 영역이 적었을 뿐 아니라 일부 파형은 표준자극을 주었을 때보다 표적자극을 주었을때 오히려 진폭이 의미 있게 감소하여서 이들이 표적자극에 대해 활성이 억제됨을 알 수 있었다. 정상 아동들은 표준자극보다 표적자극에 대해서 거의 모든 전극 위치와 주파수 대열에서 의미 있는 진폭의 증가를 보였으나 전전두엽과 전두엽의 전극에서는 주의력결핍 ${\cdot}$ 과잉운동장애 아동이 더 큰 진폭을 보이는 경우가 관찰되었다. 웨이브렛 분석 결과 표준자극에 대해서는 주의력결핍 ${\cdot}$ 과잉운동장애 아동이 정상 아동보다 자극이 제시된 후 $0{\sim}300msec$ 사이에 일어나는 전위가 통계적으로 의미 있게 컸다. 이런 차이는 주로 전전두엽과 전두엽 앞쪽, 그리고 측두엽 일부와 후두엽에서 두드러졌다. 그러나 두정엽과 중앙 영역의 전극들은 특히 $300{\sim}370msec$ 이내에 일어나는 전위에서 정상 아동이 더 활발한 전기 활동을 나타내었다. 표적자극에 대해서는 두 군 모두 표준자극보다 전기 활성이 더 증가한 양상이었다. 표적자극에 대해서 주의력결핍 ${\cdot}$ 과잉운동장애 아동은 전전두엽과 전두엽 영역에서는 여전히 정상 아동보다 더 활발한 전기 활성을 보였으나 두정엽과 측두엽에서는 정상 아동이 더 큰 진폭을 나타내었다. 이로써 주의력결핍 ${\cdot}$ 과잉운동장애 아동은 무시해야 하는 자극에 대해서는 지나친 반응을 보이며 주의집중을 필요로 하는 자극에 대해서는 정상 아동보다 저하된 반응을 보이는 것이 확인되었다. 이와 함께 푸리에 변환 등 주파수 차원 분석법과 웨이브렛 분석 방법의 유용성을 알아보았다.

  • PDF

BaV2O6와 BaWO4을 이용한 초저온 동시소성 세라믹 제조 (Fabrication of a Novel Ultra Low Temperature Co-fired Ceramic (ULTCC) Using BaV2O6 and BaWO4)

  • 김두원;이경호
    • 마이크로전자및패키징학회지
    • /
    • 제28권4호
    • /
    • pp.11-18
    • /
    • 2021
  • (1-x)BaWO4-xBaV2O6(x=0.54~0.85) 조성의 새로운 초저온 동시 소성 세라믹(ULTCC)용 마이크로파 유전체 복합 재료를 BaWO4와 BaV2O6의 혼합물을 소성하여 제조되었다. 수축 시험은 세라믹 복합재가 BaV2O6의 영향으로 500℃의 낮은 온도에서 치밀화가 시작되며, 650℃에서 상대밀도 98%로 소결될 수 있음을 보였다. X-선 회절 분석은 복합체는 BaWO4와 BaV2O6이 공존하고 소결체에서 2차상이 검출되지 않음을 보였다. 이는 두 상이 서로 우수한 화학적 안정성이 있음을 의미하였다. 거의 0에 가까운 공진 주파수 온도계수(𝛕f)는 복합체에 존재하는 두 상의 𝛕f 값이 각각 양(+) 및 음(-)의 값임에 따라 두 상의 상대적 함량을 조절하여 얻을 수 있었다. BaV2O6의 함량이 x=0.53에서 0.85로 증가함에 따라 복합 재료의 𝛕f 값은 7.54에서 14.49 ppm/℃로 증가하였고 εr은 10.08에서 11.17로 증가했으며 Q×f값은 47,661에서 37,131 GHz로 감소하였다. 최고의 마이크로파 유전 특성은 BaV2O6의 함량이 x=0.6 일 때, εr=10.4, Q×f=44,090 GHz 및 𝛕f=-2.38 ppm/℃값을 얻을 수 있었다. 화학적 호환성 실험은 개발된 복합 재료가 동시 소성 과정에서 알루미늄 전극과 반응성이 없음을 보여주었다.