• 제목/요약/키워드: Negative Bending Test

검색결과 21건 처리시간 0.024초

Cracking and bending strength evaluations of steel-concrete double composite girder under negative bending action

  • Xu, Chen;Zhang, Boyu;Liu, Siwei;Su, Qingtian
    • Steel and Composite Structures
    • /
    • 제35권3호
    • /
    • pp.371-384
    • /
    • 2020
  • The steel-concrete double composite girder in the negative flexural region combines an additional concrete slab to the steel bottom flange to prevent the local steel buckling, however, the additional concrete slab may lower down the neutral axis of the composite section, which is a sensitive factor to the tensile stress restraint on the concrete deck. This is actually of great importance to the structural rationality and durability, but has not been investigated in detail yet. In this case, a series of 5.5 m-long composite girder specimens were tested by negative bending, among which the bottom slab configuration and the longitudinal reinforcement ratio in the concrete deck were the parameters. Furthermore, an analytical study concerning about the influence of bottom concrete slab thickness on the cracking and sectional bending-carrying capacity were carried out. The test results showed that the additional concrete at the bottom improved the composite sectional bending stiffness and bending-carrying capacity, whereas its effect on the concrete crack distribution was not obvious. According to the analytical study, the additional concrete slab at the bottom with an equivalent thickness to the concrete deck slab may provide the best contributions to the improvements of crack initiation bending moment and the sectional bending-carrying capacity. This can be applied for the design practice.

A Study on the Bending and Seismic Performance of High Performance Cold Forming Composite Beam

  • Choi, Young Han;Kim, Sung Bae;Hong, Hyung Ju;Kim, Sang Seup
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1772-1783
    • /
    • 2018
  • Nowadays, the researches about composite structure system are being implemented in various fields, and many steel structures are designed based on that. In this study, the bending and seismic performance of the newly developed high-performance cold forming composite beam are evaluated by several experiments. As a result of the bending performance test, the bending moment of beam was increased stably depending on the depth and plate thickness of beam, and it is considered that the bending moment can be evaluated by the equation of a composite beam design. As a result of the seismic performance test, it was verified that sufficient seismic performance was obtained despite the increase of a negative moment rebar and depth of beam. In addition, the nominal bending moment has obtained the strength above the plastic bending moment, and also the plastic rotation angle has satisfied the requirement of composite intermediate moment frame.

신형상 냉간성형 단면의 구조적 거동(II) - 휨거동 (Structural Behavior of Newly Developed Cold-Formed Steel Sections(II) - Flexural Behavior)

  • 송인섭;김갑득;권영봉
    • 한국강구조학회 논문집
    • /
    • 제14권2호
    • /
    • pp.357-364
    • /
    • 2002
  • 스터드, 조이스트 및 지붕 트러스에 적용하기 위한 폐단면 냉간성형부재의 휨실험을 수행하고 해석치와 비교하여 보았다. 길이 2.4m, 폭 0.9m의 휨 시편은 46cm 간격의 두 개의 강재보의 한면에 석고보드와 합판을 부착한 시편과 부착하지 않은 시편으로 구성되었고, 각 시편에 대한 정, 부모멘트실험을 수행하여, 강재보에 부착된 합판 및 석고보드가 강재의 좌굴거동에 미치는 영향을 포함한 합성거동을 파악하였다. 또한 합판이 부착된 실물 트러스 실험을 통하여 트러스 부재의 좌굴거동 및 파괴양상에 대하여 연구하였다.

Moment redistribution of continuous composite I-girder with high strength steel

  • Joo, Hyun Sung;Moon, Jiho;Sung, Ik-Hyun;Lee, Hak-Eun
    • Steel and Composite Structures
    • /
    • 제18권4호
    • /
    • pp.873-887
    • /
    • 2015
  • The continuous composite I-girder should have a sufficient rotation capacity (or ductility) to redistribute the negative bending moment into an adjacent positive bending moment region. However, it is generally known that the ductility of the high strength steel is smaller than that of conventional steel, and application of high strength steel can cause ductility problems in a negative moment region of the I-girder. In this study, moment redistribution of the continuous composite I-girder with high strength steel was studied, where high strength steel with yield stress of 690 MPa was considered (the ultimate stress of the steel was 800 MPa). The available and required rotation capacity of the continuous composite I-girder with high strength steel was firstly derived based on the stress-strain curve of high strength steel and plastic analysis, respectively. A large scale test and a series of non-linear finite element analysis for the continuous composite I-girder with high strength steel were then conducted to examine the effectiveness of proposed models and to investigate the effect of high strength steel on the inelastic behavior of the negative bending moment region of the continuous composite I-girder with high strength steel. Finally, it can be found that the proposed equations provided good estimation of the requited and available rotation capacity of the continuous composite I-girder with high strength steel.

Shear behavior and shear capacity prediction of precast concrete-encased steel beams

  • Yu, Yunlong;Yang, Yong;Xue, Yicong;Liu, Yaping
    • Steel and Composite Structures
    • /
    • 제36권3호
    • /
    • pp.261-272
    • /
    • 2020
  • A novel precast concrete-encased steel composite beam, which can be abbreviated as PCES beam, is introduced in this paper. In order to investigate the shear behavior of this PCES beam, a test of eight full-scale PCES beam specimens was carried out, in which the specimens were subjected to positive bending moment or negative bending moment, respectively. The factors which affected the shear behavior, such as the shear span-to-depth aspect ratio and the existence of concrete flange, were taken into account. During the test, the load-deflection curves of the test specimens were recorded, while the crack propagation patterns together with the failure patterns were observed as well. From the test results, it could be concluded that the tested PCES beams could all exhibit ductile shear behavior, and the innovative shear connectors between the precast concrete and cast-in-place concrete, namely the precast concrete transverse diaphragms, were verified to be effective. Then, based on the shear deformation compatibility, a theoretical model for predicting the shear capacity of the proposed PCES beams was put forward and verified to be valid with the good agreement of the shear capacities calculated using the proposed method and those from the experiments. Finally, in order to facilitate the preliminary design in practical applications, a simplified calculation method for predicting the shear capacity of the proposed PCES beams was also put forward and validated using available test results.

원심모형실험에 의한 사질토 지반내 터널 복공의 역학적 거동에 관한 연구 (Analysis of the Structural Behaviors of Tunnel Linings in Joomunjin Standard Sand by Centrifugal Model Tests)

  • 김택곤;김영근;박중배;이희근
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.161-168
    • /
    • 1999
  • A series of centrifuge model tests were performed in order to investigate the behaviors of various tunnel linings. A 1/100-scaled aluminum and hydrostone horseshoe tunnel linings with a radius km, height km were buried in a depth of C/D=3 with dry Joomunjin standard sand, the relative density of which was 86%. Bending moments and thrusts along the tunnel circumference were measured by 12 strain gages. Earth pressures in soil and on lining were estimated by pressure transducers, ground surface settlements at center and edges by using LVDTs. Average Ko(coefficient of earth pressure at rest) was 0.39 for the model sand. The structural behaviors of lining depended on its damaged conditions. But, as a rule, on the crown, the tensile circumferential strain of lining occurred at the inner surface, and the compressive at the outer surface, then positive bending moment was created at the crown. The circumferential strain of the inner surface on the springline was tensile, and the outer compressive, so negative bending moment was measured at the springline. For hydrostone linings, cracks initiated at the inner surface on the crown, and the outer on the springline over average 40g.

  • PDF

수동 견갑골 거상 검사에 따라 분류된 경부통 환자의 견갑골 안정화운동 효과 비교 (Effect of Scapular Stabilization Exercise on Patients With Neck Pain Classified According to Passive Scapular Elevation Test)

  • 김하연;김선엽;장현정;주명규
    • 한국전문물리치료학회지
    • /
    • 제19권3호
    • /
    • pp.51-60
    • /
    • 2012
  • This study aimed to determine the usefulness of classifying patients with neck pain on the basis of the results of passive scapular elevation test. We classified 21 patients with neck pain into positive (n=12) and negative (n=9) groups on the basis of passive scapular elevation test; the 2 groups then equally performed scapular stabilization exercise program for 30 min, 3 times a week, for 4 weeks. Visual analogue scale (VAS), neck disability index (NDI), and range of motion (ROM) were recorded both before and after the intervention for both groups. Paired t-test was used to determine that there were significant changes between before and after the intervention, and independent t-test was used for analyzing changes between two groups of dependent variables. After 4 weeks of training, we observed significant decrease in pain and disability (p<.05) and a significant increase in rotation, flexion, extension, and side-bending ROM (p<.05) in both groups. Further, between pre- and post-intervention evaluations, we observed a significant decrease in pain and disability and a significant increase in rotation and flexion ROM in the positive group than in the negative group (p<.05). These results indicate that passive scapular elevation test may be used to identify mechanical disorders of the cervicoscapular muscle in patients with neck pain. Therefore, we recommend the use of passive scapular elevation test to determine appropriate treatment intervention when treating patients with neck pain.

매립형 역T형 합성보의 휨내력에 관한 실험적 연구 (An Experimental Study on Flexural Strength of Inverted T-shaped Composite Beams encased with concrete)

  • 장희성;정재훈;김진무;주경재
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권3호
    • /
    • pp.145-152
    • /
    • 2000
  • In simply supported composite beams, the neutral axis of the composite cross section is usually located near the top flange of the steel H-shape, so that the top flange does not impart much strength to the member. This suggests that omitting the top flange entirely could be a means to lower the cost of the beam without greatly reducing the strength. However, It is not easy for inverted T-shaped composite beam to construct and to apply continuous beam which has negative bending moment. As a result, it would get more workability and decrease capability of lateral buckling and local buckling, if the bottom flange of inverted T-shaped steel used as a form. Therefore. the objectives of this study are to investigate strength and behaviors of inverted T-shaped composite beam which web is encased by concrete and to grasp bending capacity and efficiency of composite by comparing and analyzing in test piece.

  • PDF

Pin-on-disk를 이용한 기초 마찰소음 실험 연구 (A Basic Experimental Study on the Squeak Noise Using the Pin-on-disk)

  • 남재현;강재영
    • 한국소음진동공학회논문집
    • /
    • 제22권8호
    • /
    • pp.736-741
    • /
    • 2012
  • Squeak noise is studied by using the pin-on-disk system with aluminum pin and steel disk. Noise induced by friction is measured with respect to the normal loads and sliding speeds. The negative slope of friction-velocity curve is seen when the squeak noise occurs. It is found that the normal load influences on the sound level of squeak noise. From the hammering test, the major frequency of the squeak noise is shown to correspond to one of system modes, which implies that squeak phenomenon arises from the unstable system modes. The result of FE analysis shows that the major squeak mode is the bending mode of the pin.

교량받침의 거동특성을 고려한 내하력 평가 (Load carrying capacity Evaluation Considering the Structural Characteristics of Bridge Bearing)

  • 박길현;양승현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권4호
    • /
    • pp.209-216
    • /
    • 2003
  • 교량의 내하력평가는 유지관리에 있어서 매우 중요한 요소이다. 재하시험과 구조해석에 의한 처짐이 차이를 보이는 이유는 여러 가지가 있다. 특히, 지점의 실제 거동특성을 고려하지 않고 일률적으로 모델링을 하는 경우에 이러한 문제가 더욱 심화될 수 있다. 이는 응력보정계수를 크게 산정하여 내하력을 실제보다 더 크게 평가할 우려가 있다. 본 연구에서는 지점의 거동특성을 고려하여 산정한 지점의 부모멘트를 이용하여 실제거동에 근접한 구조해석을 실시하야 보다 정확한 내하력을 평가하고자 한다.