• 제목/요약/키워드: Needle detection

검색결과 94건 처리시간 0.024초

GIS에 있어서 UHF법을 이용한 부분방전 검출에 대한 연구 (A Study on the PD Detection Using a UHF Method in GIS)

  • 윤진열;정길조;??재구;김광화;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2063-2065
    • /
    • 1999
  • PD pulses have about one nanosecond rise time in the $SF_6$ gas insulation. These pulses propagate through GIS chamber to PD sensors in the form of the electromagnetic radiation. In this paper, we investigated the characteristics of disc sensors and monopole antenna, by putting high frequency signals into the test cell in $SF_6$ gas by means of a Ins rise time pulse generator and 60Hz power supply respectively. Also, we measured PD quantity from the needle electrode and the location effect of output terminal beneath the disk sensors.

  • PDF

광섬유센서를 이용한 유중방전 신호검출 (Discharge Signal Detection in Insulating Oil using Optical Fiber sensor)

  • 이준호;이종길;김상준;남진호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2066-2068
    • /
    • 1999
  • In this paper, an optical fiber sensor(OF sensor) utilizing the principal of Sagnac interferometer was proposed to detect the discharge signals which generated from needle-sphere electrode system in insulating oil. The performance of OF sensor was checked by sinusoidal calibration signal generated by PZT acuator at 198kHz. The detected discharge signals consisted of acoustic signal and the electrical noise. The noise signal could be removed by digital low pass filter. It was demonstrated that the OF sensor in this research had a possibility to detect the discharge signals in power apparatus.

  • PDF

전력케이블의 절연결함에 따른 부분방전 특성분석 (Analysis of PD Characteristics by Types of Insulation Defects in Power Cables)

  • 최재성;박찬용;김선재;한주섭;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1977-1983
    • /
    • 2009
  • This paper described partial discharge(PD) patterns depending on types of insulation defects in CNCO-W cable(Concentric Neutral Closs-linked Polyethylene Insulated Polyolefin-Water Proof Sheathed Power Cable). The PD measurement system consists of a coupling network, a detection impedance, and a low noise amplifier. A 16 bit, 250 MS/s data acquisition system was used to analyze PD patterns. To simulate insulation defects in a power cable, a needle with the curvature radius of $10{\mu}m$ was inserted into the insulation part. We measured phase ($\Phi$), magnitude (q), and counts (n) of PD pulse for the defects, and classified PD patterns using the PRPD (phase Resolved Partial Discharge) method. From the analysis of acquired PD signals, we could find that a unique PD pattern is formed according to the types of defect.

  • PDF

애폭시수지의 트리성장에 따른 초음파 신호검출 (Detection of Ultrasonic Signals Associated with Tree Growth in Epoxy resin)

  • 이상우;송현직;이광식;이동인;김인식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.285-288
    • /
    • 1998
  • Ultrasonic signal characteristics related with the growth of electrical trees in epoxy resin are examined under 67[Hz] ac voltage application along with a CCD camera and PD current method. The ultrasonic sensor with a resonant frequency of 200[Hz] supported by a mechanical spring is attached directly to the lower-side of plane electrode. The magnitude of Partial discharge and count rate of ultrasonic signals have been measured according to the tree growth from a needle tip in an epoxy sample.

  • PDF

변압기 부분방전에 의한 초음파 신호의 발생형태 (Patterns of the Ultrasonic Signal caused by Partial Discharge in Transformer)

  • 권동진;최인혁;정길조;박찬영;나현석;박재준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.581-584
    • /
    • 2000
  • Generally, it is known that many partial discharges are occurred in one voltage cycle. In this case, it is not easy to distinguish between ultrasonic signals caused by the partial discharge. We describes a pattern of the ultrasonic signal by the partial discharge in transformer. The test setup for ultrasonic signal measurement was to simulate a internal partial discharge by using a needle to plane electrodes. We compared the number of partial discharge and ultrasonic signal in one voltage cycle. The results showed that it was possible to distinguish between ultrasonic signals by analysing partial discharge detection method and ultrasonic signal on time domain.

  • PDF

광섬유 Sagnac 간섭계를 이용한 유중방전 신호검출 (Discharge Signal Detection in Insulating Oil using the Optial Fiber Sagnac Interferometer)

  • 이종길;이준호;김상준
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권11호
    • /
    • pp.622-626
    • /
    • 2000
  • In this paper, an optical fiber sensor(OF sensor) utilizing the principal of Sagnac interferometer was proposed to detect the discharge signals. The needle-sphere electrode system in insulating oil generated the signals. The performance of OF sensor was checked by sinusoidal calibration signal generated by PZT actuator at 198KHz. The detected discharge signals consisted of acoustic signal and the electrical noise. The noise signal could be removed by digital low pass filter. It was demonstrated that the OF sensor in this research had a possibility to detect the discharge signals in power apparatus.

  • PDF

유중방전 초음파 신호의 광학적 측정 및 wavelet 분석 (The optical measurement and wavelet analysis about ultrasonic signals by discharge in oil)

  • 이상훈;이현철;지승욱;김충년;송현직;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.298-303
    • /
    • 2004
  • It is well known that a discharge in oil is the source of various physical phenomena. Ultrasonic-wave detection is a useful method to the diagnosis of the transformer-insulation condition. Conventionally, ultrasonic waves are detected by Piezo-electric transducer, and we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test arrangement is based rut the needle-plane electrode system in oil and applied AC high voltage Ultrasonic waves were detected and showed signal- analysis results with wavelet transform.

  • PDF

귀밑샘의 기무라병의 세침흡인 세포학적 소견 -세포학적 검사로 예측할 수 없었던 1예 보고- (Fine Needle Aspiration Cytology of Kimura's Disease of Parotid Gland - Report of A Case Cytologically Failed to Diagnose as Kimura's Disease -)

  • 김세훈;김혜령;김성은;양우익;이광길;홍순원
    • 대한세포병리학회지
    • /
    • 제14권2호
    • /
    • pp.86-90
    • /
    • 2003
  • Kimura's disease is a chronic inflammatory disorder of unknown cause and is most prevalent among Asians. The cytologic findings of Kimura's disease are significant numbers of eosinophils in a background of lymphoid cells, occasional fragments of collagenous tissue, proliferation oi vessels, and Warthin-Finkeldey polykaryocytes. Among these features, the most important cytologic feature of Kimura's disease is a significant numbers of eosinophils. We experienced a case of Kimura's disease in the parotid gland which we fatted to recognize on cytology due to the apparent paucity of eosinophils. On careful retrograde reviewing of the cytologic findings, a few scattered leukocytes, previously interpreted as polymorphous leukocytes, had bilobed nuclei and coarse green but granular cytoplasm on Papanicolaou preparation. These leukocytes showed obvious orange-red intracyloplasmic granules as in eosionophils on Giemsa stain. The paucity of eosinophils may be due to the thick fibrosis around lymphoid follicles or any technical error during aspiration. Whereas the Warthin-Finkeldey type giant cell is not a sensitive cytologic marker of Kimura's disease, it may be a helpful cytologic feature. To reach a correct cytologic diagnosis of Kimura's disease, It is important to keep in mind that searching for Warthin-Finkeldey type giant cells and evaluation of Giemsa stain for detection of eosinophils would be helpful.

Comparison of Cellular Features Diagnostic of Papillary Thyroid Carcinoma in Liquid-Based (Cell Scan 1500TM) Preparations and Conventional Smears

  • Lee, Jung Dal;Park, Yong Wook;Back, OunCheol;Jung, Pa Jong;Kim, Jong Yull
    • 대한임상검사과학회지
    • /
    • 제45권3호
    • /
    • pp.108-113
    • /
    • 2013
  • The study compared the cytological features of papillary thyroid carcinoma (PTC) in liquid-based preparations (LBPs) and conventional Pap (CP) smears from fine needle aspiration (FNA), and assessed the feasibility of LBP using the Cell Scan $1500^{TM}$ processor on thyroid FNA samples. Thyroid FNA samples were obtained from 883 consecutive patients. Each sample was divided into two and used for LBPs and CP smears. All were screened independently in a double-blind manner. From the 883 cases, 95 cases were diagnosed as PTC in one or both types of preparation (10.8%). PTC was diagnosed via CP smears in 83 cases (87.4%) and via LBPs in 70 cases (73.7%). However, there were differences in categorization between the paired preparations: Twelve (12) PTCs were misinterpreted in CP smears and 25 PTCs in LBPs. There was a significant discrepancy in the rate of detection of the diagnostic features, with LBPs having a lower detection rate. One (1) case (1.2%) of CP smears and 16 cases (22.9%) of LBPs were categorized as unsatisfactory/nondiagnostic in a total of the 95 PTCs. To conclude, the detection rate of the diagnostic features of PTC is lower in Cell Scan 1500TM samples than in CP smears. However, there are some cases in which a diagnosis of PTC is made in LBPs, but not in CP smears. Therefore, definitive cancer diagnosis in thyroid FNA preparations is likely to result from agreement between direct smears and Cell Scan 1500TM preparations.

  • PDF

Impedance Parameter Variations at Intravenous (IV) Infiltration Using Bioelectrical Impedance: A Pilot Study

  • Kim, Jaehyung;Lee, Mansup;Baik, Seungwan;Kim, Gunho;Hwang, Youngjun;Jeon, Gyerok
    • 한국멀티미디어학회논문지
    • /
    • 제20권10호
    • /
    • pp.1678-1688
    • /
    • 2017
  • Infiltration is one of detrimental problems occurring in nursing or medical settings. Early detection of infiltration is essential to minimize the risk of injury from infiltration. To perform a preliminary study on the point of care and automated infiltration detection system, bioelectrical impedance was investigated using bioelectrical impedance analyzer. We would like to report experimental results that allow impedance parameters to effectively distinguish infiltration. Electrodes were attached to both sides of the transparent dressing on the fusion site where IV solution was being infused. Then, impedance parameters before and after infiltration were measured as a function of time and frequency. The experimental results are as follows. After infiltration was intentionally induced by puncturing the vein wall with a needle, the resistance gradually decreased with time. That is, when an alternating current having a frequency of 20 kHz was applied to the electrodes, the resistance gradually decreased with time, reflecting the accumulation of IV solution in the extracellular fluid since the current could not pass through the cell membrane. Impedance parameters and equivalent circuit model for human cell were used to examine the mechanism of current flow before and after infiltration, which could be used for early detection of infiltration.