• 제목/요약/키워드: Needle Insertion Force Model

검색결과 4건 처리시간 0.022초

침자 술기 실습 모델에서 침감의 정량적 특성에 관한 연구 (A Study on the Quantitative Characteristics of Needle Force on the Acupuncture Practical Model)

  • 이연선;김선혜;김은정;이승덕;김경호;김갑성;정찬영
    • Korean Journal of Acupuncture
    • /
    • 제35권3호
    • /
    • pp.149-158
    • /
    • 2018
  • Objectives : In this study, we quantitatively evaluated the needle forces using needle insertion-measurement system and compared the needle sensation of each acupuncture practical model. Methods : After inserting acupuncture with a sensor to six models, a lifting-thrusting motion was implemented using the needle insertion-measurement system. The needle force was measured repeatedly, and the measurement was analyzed based on the modified Karnopp friction model for a comparison of friction coefficients. After the insertion, practitioners did lifting-thrusting manipulations. They quantified the similarity of needle sensation with VAS (Visual Analogue Scale). Results : When friction force and coefficients of friction in five different models were compared with a porcine shank model, all five models were significantly different from a porcine shank model, cotton and apple showing the closest frictional values to that of a porcine shank model. In the Cp and Cn values of cotton and in the Cp values of IM injection pad, there was no statistically significant difference. The similarity of the needle sensation between the porcine shank and five models was the highest in the apple, and overlapping papers was the lowest. Conclusions : This study quantitatively compared the physical forces in the practical model when implementing lifting-thrusting manipulations, using a needle insertion-measurement system. We suggest that a reproducible exercise model that reflects the characteristics of various human tissues, such as viscoelasticity or strength, needs to be further developed. This will contribute to establishing standardized acupuncture practice training.

3자유도 힘반향 장치를 이용한 침생검 햅틱 시뮬레이터 (Three OOP Haptic Simulator for a Needle Biopsy)

  • 권동수;경기욱;감홍식;박현욱;나종범
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.539-539
    • /
    • 2000
  • This paper shows how to implement force reflection for a needle insertion problem. The target is a needle spine biopsy simulator for tumor inspection by needle insertion. Simulated force is calculated from the relationship of volume graphic data and the orientation and Position of the needle, and it is generated using PHANTOM$^{TM}$. To generate realistic force reflection, the directional force of the needle has been generated by tissue model. The other rotational force is generated using a pivot to keep the needle in the initial inserted direction after puncturing the skin. Since the used haptic device has limitation for generating high stiffness and large damping, scale downed model and digital filter are used to stabilize the system.m.

  • PDF

척추 바늘 삽입술 시뮬레이터 개발을 위한 인공지능 기반 척추 CT 이미지 자동분할 및 햅틱 렌더링 (AI-based Automatic Spine CT Image Segmentation and Haptic Rendering for Spinal Needle Insertion Simulator)

  • 박익종;김기훈;최건;정완균
    • 로봇학회논문지
    • /
    • 제15권4호
    • /
    • pp.316-322
    • /
    • 2020
  • Endoscopic spine surgery is an advanced surgical technique for spinal surgery since it minimizes skin incision, muscle damage, and blood loss compared to open surgery. It requires, however, accurate positioning of an endoscope to avoid spinal nerves and to locate the endoscope near the target disk. Before the insertion of the endoscope, a guide needle is inserted to guide it. Also, the result of the surgery highly depends on the surgeons' experience and the patients' CT or MRI images. Thus, for the training, a number of haptic simulators for spinal needle insertion have been developed. But, still, it is difficult to be used in the medical field practically because previous studies require manual segmentation of vertebrae from CT images, and interaction force between the needle and soft tissue has not been considered carefully. This paper proposes AI-based automatic vertebrae CT-image segmentation and haptic rendering method using the proposed need-tissue interaction model. For the segmentation, U-net structure was implemented and the accuracy was 93% in pixel and 88% in IoU. The needle-tissue interaction model including puncture force and friction force was implemented for haptic rendering in the proposed spinal needle insertion simulator.

햅틱 기반 정맥주사 시뮬레이터를 위한 생체조직 바늘 삽입력 (Needle Insertion Force of Biological Soft Tissue for Haptic based Intravenous Injection Simulator)

  • 안범모;정은영;이영호;임용수;박래웅;김정;박동균
    • 한국정밀공학회지
    • /
    • 제29권2호
    • /
    • pp.222-228
    • /
    • 2012
  • Haptics and virtual reality are rapidly growing technologies in medical fields. Physicians and nurses can benefit from medical simulation via training and acquire surgical and clinical techniques. In this paper, the research on needle insertion force of biological tissue for haptic based intravenous injection simulator was carried out. We built the setup for needle insertion (intravenous injection) experiments and performed the experiments on live pigs. The force responses against needle insertion were measured using the experimental setup. In addition, the modeling of needle insertion force was carried out with the experimental results and numerical models via nonlinear least-squares method. The results presented in this paper indicate that the developed models can be applied not only to estimate the force feedback during intravenous injection procedure but also to improve the overall training quality of the medical simulator.