• Title/Summary/Keyword: Neck stability

Search Result 85, Processing Time 0.019 seconds

Clinical application of implant assisted removable partial denture to patient who underwent mandibular resection with oral cancer: A case report (구강암으로 변연골 절제술 시행한 환자를 임플란트 보조 국소의치로 수복한 증례)

  • Yoon, Young-Suk;Han, Dong-Hoo;Kim, Hyung-Joon;Kim, Jee Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.280-285
    • /
    • 2016
  • Mandible defects could be caused by congenital malformations, trauma, osteomyelitis, tumor resection. If large areas are included for reconstruction, those are primarily due to tumor resection defects. The large jaw defect results in a problem about mastication, swallowing, occlusion and phonetics, and poor esthetics causes a lot of inconvenience in daily life. It is almost impossible to be a part underwent mandibular resection completely reproduced, should be rebuilt artificially. This case is of a patient who was diagnosed with squamous cell carcinoma pT1N0M0, stage I in February 2004 and received surgery (combined mandibulectomy and neck dissection operation (COMMANDO) in oromaxillofacial surgery) in March 2004, by implant assisted removable partial denture. We could obtain good retention and stability through sufficient coverage and implant holding. Follow up period was about four years. Mandibular left third molar regions have been observed to have resorption of surrounding bone, and periodic check-ups are necessary conditions.

Hip Range of Motion Estimation using CT-derived 3D Models (CT기반 3차원 모델을 이용한 고관절 운동범위 예측)

  • Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.115-122
    • /
    • 2018
  • The success of the total hip arthroplasty is revealed as initial stability, range of motion, and long term pain, etc. Depending upon choice of implantation options such as femoral neck offset, diameter of the femoral head, the lateral opening tilt. Especially the impingement between femoral head component and acetabular cup limits the range of motion of the hip. In this sense, estimation or evaluation of the range of motion before and after the total hip arthroplasty is important. This study provides the details of a computer simulation technique for the hip range of motion of intact hip as well as arthroplasty. The suggested method defines the hip rotation center and rotation axes for flexion and abduction, respectively. The simulation uses CT-based reconstructed 3D models and an STL treating software. The abduction angle of the hip is defined as the superolateral rotation angle from sagittal plane. The flexion angle of the hip is defined as the superoanterior angle from the coronal plane. The maximum abduction angle is found as the maximum rotation angle by which the femoral head can rotate superolaterally about the anterior-posterior axis without impingement. The maximum flexion angle is found as the maximum rotation angle by which the femoral head can rotate superoanteriorly about the medial-lateral axis without impingement. Compared to the normal hip, the total hip replacement hip showed decreased abduction by 60 degrees and decreased flexion by 4 degrees. This measured value implies that the proposed measurement technique can make surgeons find a modification of increase in the femoral neck offset or femoral head, to secure larger range of motion.

A study on the relationship between job stress and subjective symptoms associated with musculoskeletal disorders of the financial working woman's (금융직 여성 근로자의 직무스트레스 실태와 근골격계질환 자작증상과의 관련성 연구)

  • Cho, Ki-Hong;Choi, Soon-Young;Park, Dong-Hyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.4
    • /
    • pp.17-28
    • /
    • 2007
  • This study tried to identify the job stress characteristics of female bank workers and the relationship between their stress and symptoms associated with musculoskeletal disorders(MSDs). The total number of 587 female bank tellers have been participated in this study. Specifically, questionnaire surveys regarding job stress and MSDs symptoms were conducted. On the basis of the results from the survey using Korean version of job stress questionnaire with 24 questions, stress scores associated with job requirement and job flexibility were relatively high. The job stress levels regarding job demand, organizational system, occupational climate at the work place were relatively high for the full time workers while the job stress levels regarding insufficient job control, job stability, interpersonal conflict, lack of reward were relatively high for the part time worker. The workers with longer total work years had relatively high job stress associated with interpersonal conflict, and organizational system while the workers with longer work years at the current job had relatively high job stress associated with occupational climate. Also, the workers with longer working hours a day had relatively high job stress associated with job demand, interpersonal conflict, organizational system, and occupational climate. According to the relationship identified in this study, symptoms at the neck, shoulder, hand, low back. leg were associated with the stress levels in terms of job flexibility, interpersonal conflict, job requirement, job stability. In conclusion, female bank workers are exposed to job stress due to their specific job characteristics and there has been certain relationships between their job stress and MSDs symptoms.

Effect of Tightening Torque on Abutment-Fixture Joint Stability using 3-Dimensional Finite Element Analysis (임플란트 지대주나사의 조임회전력이 연결부 안정성에 미치는 영향에 관한 3차원 유한요소해석 연구)

  • Eom, Tae-Gwan;Suh, Seung-Woo;Jeon, Gyeo-Rok;Shin, Jung-Wook;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.125-135
    • /
    • 2009
  • Statement of problem: Loosening or fracture of the abutment screw is one of the common problems related to the dental implant. Generally, in order to make the screw joint stable, the preload generated by tightening torque needs to be increased within the elastic limit of the screw. However, additional tensile forces can produce the plastic deformation of abutment screw when functional loads are superimposed on preload stresses, and they can elicit loosening or fracture of the abutment screw. Therefore, it is necessary to find the optimum tightening torque that maximizes a fatigue life and simultaneously offer a reasonable degree of protection against loosening. Purpose: The purpose of this study was to present the influence of tightening torque on the implant-abutment screw joint stability with the 3 dimensional finite element analysis. Material and methods: In this study, the finite element model of the implant system with external butt joint connection was designed and verified by comparison with additional theoretical and experimental results. Four different amount of tightening torques(10, 20, 30 and 40 Ncm) and the external loading(250 N, $30^{\circ}$) were applied to the model, and the equivalent stress distributions and the gap distances were calculated according to each tightening torque and the result was analyzed. Results: Within the limitation of this study, the following results were drawn; 1) There was the proportional relation between the tightening torque and the preload. 2) In case of applying only the tightening torque, the maximum stress was found at the screw neck. 3) The maximum stress was also shown at the screw neck under the external loading condition. However in case of applying 10 Ncm tightening torque, it was found at the undersurface of the screw head. 4) The joint opening was observed under the external loading in case of applying 10 Ncm and 20 Ncm of tightening torque. 5) When the tightening torque was applied at 40 Ncm, under the external loading the maximum stress exceeded the allowable stress value of the titanium alloy. Conclusion: Implant abutment screw must have a proper tightening torque that will be able to maintain joint stability of fixture and abutment.

Effect Analysis of Virtual-reality Vestibular Rehabilitation based on Eye-tracking

  • Lee, Sungjin;Hong, Min;Kim, Sungyeup;Choi, Seong Jun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.2
    • /
    • pp.826-840
    • /
    • 2020
  • Vertigo is one of the most common complaints encountered by physicians and the patients are steadily increasing. These patients are exposed to the risk of secondary accidents such as falls due to vertigo. There are two ways to improve this symptom: medication and rehabilitation. Although temporary symptomatic improvement may be expected in patients treated with medication, vertigo may recur and medication can delay central compensation. In contrast vestibular rehabilitation exploits central mechanisms of neuroplasticity to increase postural stability and enhance visual-vestibular interactions in situations that generate conflicting sensory information. However, vestibular rehabilitation may be compromised by incorrect performance of exercises, and there is a need for active effort and interest from the patient during rehabilitation. To solve these problems, we decided to apply FOVE HMD for eye-tracking and Unity3D to create virtual reality. The proposed eye-tracking based algorithm calculates the concentration of users with eye tracking data and calculates the motion width of the patient with nystagmus, thus the severity of the patient according to the score can be determined. According to our experimental test against healty group and patients group, this result showed the meaningful data to use define the contents result.

The Effects of Virtual Reality Games in Posture Correction Exercise on the Posture and Balance of Patients with Forward Head Posture

  • Son, Ho-Hee
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.15 no.2
    • /
    • pp.11-21
    • /
    • 2020
  • PURPOSE: This study examined the effects of posture improvement exercise using virtual reality programs on the posture and balance of patients with forward head postures. METHODS: Thirty men and women in their 20 s, who had a forward head posture, were divided randomly into a group with posture correction exercise and a group with posture correction exercise combined with virtual reality programs. The posture correction exercise was composed of squats, XCO training, and chin-tuck exercise. In contrast, exercise with virtual reality games involved the Hot Squat, Climbey, and Baskhead programs while wearing a headset. Both groups performed the exercises 15 min a day, three times per week, for four weeks. The balance ability, distance between the acromion and earlobe, and neck joint range of motion were assessed before and after the exercises. RESULTS: Both groups showed significant reductions in the distance between the acromion and the earlobe, along with significant improvements in the range of joint motion. The group that performed the virtual reality exercises showed a significant increase in the limit of stability. Both groups showed a significant decrease in the sway length. In contrast, the group given the virtual reality exercises showed a significant reduction in the sway speed while standing with their eyes closed. CONCLUSION: Exercise applying virtual reality programs can be used in clinical and home programs to correct the postures of individuals with a forward head posture because they can trigger interest in inducing active participation.

A CLINICAL STUDY ON THE APPLICATION OF LABIO-MANDIBULOTOMY APPROACH FOR ORAL AND OROPHARYNGEAL TUMORS (구강 및 구인두종양수술시 구순-하악골이단 접근법의 이용에 관한 임상적 연구)

  • Pyo, Sung-woon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.2
    • /
    • pp.225-230
    • /
    • 1999
  • The labiomandibulotomy approch to the oral cavity and oropharygeal region was first described by Roux in 1836 and become popular for oral and oropharyngeal tumors in cases where there are no clinical and radiological signs of mandible invasion. Anterior labiomandibulotomy and swing procedure provides excellent access and facilitate a mandibular resection and subsequent repair. In last two years, 8 cases of oral and oropharyngeal tumors were treated by this approach at the Dept. of Oral & Maxillofacial Surgery, Holy Family Hospital, Catholic University of Korea. And we analyzed postoperative complications as well as functional evaluations, and the results were as follows; In 4 cases, marginal mandibulectomy were combined with labiomandibulotomy and in case of malignancies, neck dissection was performed simultaneously. In almost case, plate and miniscrew fixation was used for osteotomy sites. Histologic evaluation of the resection margins of the specimens revealed tumor free in all cases. The postoperative complications were occured in 3 cases, one case of nonunion, one case of orocutaneous fistula, and one case of wound dehisence. Occlusal stability, jaw movement and swallowing function were acceptable postoperatively in 3 months. From above results, we concluded that, this approach not only provides wide exposure, permitting radical removal of benign and malignant lesions but also preserves function with minimal complications.

  • PDF

A rare case of isolated schwannoma in infraorbital nerve

  • Choi, June Seok;Park, Sang Min;Choi, Kyung-Un
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.3
    • /
    • pp.231-234
    • /
    • 2018
  • A schwannoma is a benign tumor that develops from Schwann cells. It is known to occur more frequently in women than men, and about one third of schwannoma cases occur in the head and neck area. It is also known to originate mainly in the auditory nerve. However, it is rarely associated with the trigeminal nerve, and especially, schwannomas related to the infraorbital nerve are very rare. we report a rare case of a schwannoma involving the infraorbital branch of the trigeminal nerve in a 45-year old male adult. The patient underwent physical examination and magnetic resonance imaging. The mass was approached through subciliary approach that is familiar to the plastic surgeon and completely resected. Histopathological findings showed pointed to a benign schwannoma. Infraorbital nerve schwannoma is difficult to distinguish from other diseases by means of clinical symptoms, physical findings, or imaging. In spite of its rarity, infraorbital nerve schwannoma may be considered a possible diagnosis in the case of mass on cheek. Assessment by computed tomography or magnetic resonance imaging is necessary for proper diagnosis. About the surgical approach, excision through the subciliary approach should be considered rather than the direct transfacial approach in view of stability, cosmetic effects, and familiarity.

The Effects of Cervical Range of Motion and Forward Head Posture on Cervical Manual Traction in Normal Adults (경추도수견인이 정상성인의 경추 관절가동범위와 두부전방자세에 미치는 영향)

  • Gong, Won-tae
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.25 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • Background: The purpose of this study is investigate the effects of cervical range of motion (ROM) and forward head posture (FHP) on cervical manual traction in normal adults. Methods: The subjects were randomly assigned to either the experimental group(Female 9, Male 6) who conducted the manual cervical traction or the control group(Female 9, Male 6) who did not conduct the any intervention. The subject in the EG have conducted the 1 set of 10 minutes of manual cervical traction per day, 2 times a week for 6 weeks. The cervical ROM was measured by the digital inclinometer and The factors of FHP was measured by cranial vertebral angle (CVA) and cranial rotation angle (CRA). Results: Comparing the cervical ROM and FHP between the experimental and control groups before and after the experiment, it could be seen that flexion, extension, right lateral flexion, left lateral flexion, CVA and CRA of the experimental group has been increased. Thus, cervical manual traction was resulted in the increased cervical ROM and decrease FHP. Conclusion: In this study, it was confirmed that cervical manual traction affects increase cervical ROM and decrease FHP that play a important role in neck stability and mobility.

Influence of the implant-abutment connection design and diameter on the screw joint stability

  • Shin, Hyon-Mo;Huh, Jung-Bo;Yun, Mi-Jeong;Jeon, Young-Chan;Chang, Brian Myung;Jeong, Chang-Mo
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.126-132
    • /
    • 2014
  • PURPOSE. This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. MATERIALS AND METHODS. Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (${\alpha}$=0.05). RESULTS. The postload removal torque value was high in the following order with regard to magnitude: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). CONCLUSION. The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate.