• Title/Summary/Keyword: Near point distance

Search Result 180, Processing Time 0.031 seconds

The Influence of Different Objects and Target Locations of Dominant Hand on the Non-Dominant Hand Movement Kinematics in Bimanual Reaching (양손으로 물체 옮기기 과제 수행 시 우세손이 옮기는 물체의 종류와 목표점의 위치 변화가 비우세손의 팔뻗기 동작에 미치는 영향)

  • Kim, Min-Hee;Jeon, Hye-Seon
    • Physical Therapy Korea
    • /
    • v.15 no.3
    • /
    • pp.44-52
    • /
    • 2008
  • The purpose of this study was to investigate the effects of different objects and target location of dominant hand on the non-dominant hand movement kinematics in a bimanual reaching task. Fifteen right-handed volunteers were asked to reach from same starting point to the different target point of right and left hand with grasping the objects of different size. Independent variables were 1) three different object types (small mug cup, name pen, and PET bottle), and 2) three different target locations (shorter distance, same distance, and longer distance than the non-dominant hand) of the dominant hand. Dependent variables were movement time (MT), movement distance (MD), movement mean velocity ($MV_{mean}$), and movement peak velocity ($MV_{peak}$) of the non-dominant hand. Repeated measures two-way analysis of variance (ANOVA) was used to test for differences in the non-dominant hand movement kinematics during bimanual reaching. The results of this study were as follows: 1) MT of the non-dominant hand was increased significantly when traveling with grasping the mug cup and reaching the far target location, and was decreased significantly when traveling with grasping the PET bottle and reaching the near target location of the dominant hand. 2) MD of the non-dominant hand was significantly increased during reaching the far target location, and significantly decreased during reaching the near target location with dominant hand. 3) $MV_{mean}$ of the non-dominant hand was increased significantly when traveling with grasping the PET bottle, and was decreased significantly when traveling with grasping the mug cup of the dominant hand. Therefore, it can be concluded that the changes of the ipsilateral hand movement have influence on coupling of the contralateral hand movement in bimanual reaching.

  • PDF

A study on the local heat transfer in rectangular impinging water jet cooling system (장방형 충돌수분류 냉각계의 국소열전달에 관한 연구)

  • Lee, Jong-Su;Eom, Gi-Chan;Choe, Guk-Gwang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.4
    • /
    • pp.1395-1405
    • /
    • 1996
  • The purpose of this experimental research is to investigate the local heat transfer characteristics in the upward free water jet impinged on a downward flat plate of uniform heat flux. The inner shape of rectangular nozzle used was sine curve type and its contraction ratio of inlet to outlet area was five. Experimental parameters considered were Reynolds number, nozzle exit-flat plate distance, and level of supplementary water. Local Nusselt number was influenced by Reynolds number, Prandtl number, supplementary water level, and distance between the nozzle exit and flat plate. Within the impingement region, the Nusselt number has a maximum value on the nozzle center axis and decreases monotonically outward from center. Outside of the impingement region, on the other hand, the Nusselt number has a secondary peak near the position where the distance from nozzle center reaches four times the nozzle width. However if nozzle exit velocity exceeds 6.2 m/s, the secondary peak appears also in the impingement region. The empirical equation for the stagnation heat transfer is a function of Prandtl, Reynolds, and axial distance from the nozzle exit. The optimum level of supplementary water to augment the heat transfer rate at stagnation point was found to be twice the nozzle width.

Comparison and Analysis for the Effects of Functional Progressive Addition Lenses on Binocular Vision of University Students (기능성 누진가입도렌즈가 대학생들의 양안시기능에 미치는 영향 비교 분석)

  • Kim, Chang Jin;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.105-116
    • /
    • 2010
  • Purpose: To analyze and compare differences between single vision lenses and functional progressive addition lenses and improvement to binocular visual function wearing functional lenses for pre-presbyopes altered their single vision lenses to functional progressive addition lenses with low addition. Methods: Healthy 32 subjects aged 24.03${\pm}$1.87 (male 23, female 9) who were recruited from university students wore functional progressive addition lenses (EYE-T, Chemilens Co., Korea, ADD 0.750) for 2 months. Objective refraction, corrected visual acuity at distance and near, near point of convergence, near point of accommodation, accommodative facility, phoria at distance and near were measured. And subjective satisfaction was investigated by using a questionnaire designed to fatigue, comfort, discomfort, overall satisfaction and preference. Results: Functional progressive addition lenses were better than single vision lenses at near point of convergence and accommodation, accommodative facility. Exo phoria measured at distance with single vision and functional progressive addition lenses. Exo phoria measured at near with functional progressive addition lenses was higher than that with single vision lenses. As a survey, the satisfaction was increased in questions related near work. However, single vision lenses were preferred in distance test of overall satisfaction, easy 10 adapt, lime to adapt. A survey showed thai preference of functional progressive addition lenses were increased 75.00% to 81.26% for near work, 50.00% to 65.63% for visual fatigue, 47.75% to 50.00% for visual comfort and 31.25% to 46.88% for overall comfort. Conclusions: Comparing between single vision lenses and functional progressive addition lenses, binocular visual function related near work, subjective satisfaction and preference was improved after wearing functional progressive addition lenses. This study suggested that functional progressive addition lenses were useful for long time near work.

Effects of Variation of Illumination on Visual Function Factors (조도변화가 시기능 성분에 미치는 영향)

  • Kim, Da-Young;Kim, Sang-Yeob;Cho, Hyun Gug;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.195-200
    • /
    • 2015
  • Purpose: This study was performed in order to figure out the influence of illumination on visual function. Methods: 40 adults (male 21, female 19) of average age $23.93{\pm}1.59$ years were participated in this study. The test chart surface illumination was adjusted to 5, 50, 200, 500 and 800 lx, and then amplitude of accommodation, near point of convergence, far and near distance phoria, far and near distance fusional vergence, relative accommodation, and accommodation lag were measured at each illumination condition. Results: As illumination intensity of test chart was reduced, amplitude of accommodation was significantly decreased (p<0.05), accommodation lag was also decreased, near point of convergence was receded, and horizontal phoria showed a tendency of esodeviation. In the case of negative fusional vergence, with reduction of illumination intensity, the break point and the recovery point were decreased but in the case of positive fusional vergence, the break point was increased. The negative and positive relative accommodation were significantly decreased (p<0.05) with reduction of illumination intensity. Conclusions: In clinical practice, visual functional test should be performed under condition of adequate illumination level through patient's living environment and job.

Graphic Method of Visual Analysis and Norms Determination for the Far Distance Phoria (원거리사위별 그래프 분석과 표준값 결정)

  • Joo, Seok-Hee;Park, Seong-Jong;Sim, Hyun-Seog
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.193-200
    • /
    • 2006
  • We investigated the visual analysis of the far distance phoria for 83 subjects who have emmetropia or myopia eyes, using the graphic method, and determined new norms. We got the following results from these experiments. 1. The measured norm of far distance phoria is $1.12{\Delta}$, exophoria, the that of near distance phoria is $0.50{\Delta}$, exophoria, the that of negative relative convergence at far distance(N.R.C.) is ${\times}$/11/5, the that of positive relative convergence at far distance(P.R.C.) is 10/20/8, the that negative relative convergence at near distance(N.R.C.) is 11/21/5, the that of positive relative convergence at near(P.R.C.) is 10/20/8, the that of negative relative accommodation(N.R.A.) is +2.54D, and the that of positive relative accommodation(P.R.A.) is -2.60D, respectively. We know from theses results that the measured norms of far distancet phoria is higher than Morgan's norms, while those of near distance phoria are lower than Morgan's norms. 2. We also know from these experiments that Morgan's norms are closely related to A, B, and C groups and Morgan's criterion can more usefully apply to the visual analysis. 3. In Sheard's criterion and Percival's criterion, the prism prescription is occurred when the exophoria of the far-point phoria is over $7{\sim}9{\Delta}$, and the esophoria of that is over $4{\sim}6{\Delta}$.

  • PDF

Determination of seismic hazard and soil response of a critical region in Turkey considering far-field and near-field earthquake effect

  • Sonmezer, Yetis Bulent;Celiker, Murat
    • Geomechanics and Engineering
    • /
    • v.20 no.2
    • /
    • pp.131-146
    • /
    • 2020
  • Evaluation of earthquake impacts in settlements with a high risk of earthquake occurrence is important for the determination of site-specific dynamic soil parameters and earthquake-resistant structural planning. In this study, dynamic soil properties of Karliova (Bingol) city center, located near to the intersection point of the North Anatolian Fault Zone and the East Anatolian Fault Zone and therefore having a high earthquake risk, were investigated by one-dimensional equivalent linear site response analysis. From ground response analyses, peak ground acceleration, predominant site period, 0.2-sec and 1-sec spectral accelerations and soil amplification maps of the study area were obtained for both near-field and far-field earthquake effects. The average acceleration spectrum obtained from analysis, for a near-field earthquake scenario, was found to exceed the design spectra of the Turkish Earthquake Code and Eurocode 8. Yet, the average acceleration spectrum was found to remain below the respective design spectra of the two codes for the far-field earthquake scenario. According to both near- and far-field earthquake scenarios in the study area, the low-rise buildings with low modal vibration durations are expected to be exposed to high spectral acceleration values and high-rise buildings with high modal vibration durations will be exposed to lower spectral accelerations. While high amplification ratios are observed in the north of the study area for the near-distance earthquake scenario, high amplification ratios are observed in the south of the study area for the long-distance earthquake scenario.

Improvement Air Gap Control for SIL based Near-Field Recording System (SIL을 이용한 근접장 기록계에서의 서보 방식의 개발)

  • Kim, Joong-Gon;Kim, Tae-Hun;Jeong, Jun;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.1
    • /
    • pp.1-4
    • /
    • 2007
  • A high density optical data storage device has been required for many years. In the field of the optical data storage, a near-field recording (NFR) technology is considered as a next generation one for achieving the high data density. Due to an evanescent wave effect occurred under 100nm distance which is the excessively small distance between the SIL and the disc, the most significant and difficult problem in this technology is to maintain a gap between a solid immersion lens (SIL) and a disc. Also, maintaining the gap under at least 50nm is required in the NFR gap servo system to use the evanescent wave effect efficiently. There are some institutes that have shown the novel gap servo control. In general, they use a mode switching servo method which consists of approach, hand-over and gap control mode. However there is a critical problem such as an overshoot at the tuning point from the approach mode to the hand-over mode, which may cause a collision between the SIL and the disc. In this paper, we show our NFR system and an improved gap servo system using an exponential function as the approach mode which can reduce the overshoot.

  • PDF

Distributions of the Magnetic Flux Density Near Down-Conductors Due to Various Impulse Currents (임펄스전류에 의한 인하도선 주위에서 자속밀도의 분포)

  • 이복희;장근철;이수봉;강성만;이승칠
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.2
    • /
    • pp.109-115
    • /
    • 2004
  • This paper deals with the behaviors of magnetic flux density near down-conductors by lightning currents. The background on the principle of magnetic flux density measurements using the RL self-integrating magnetic field sensor was described. The magnetic flux density measuring device consisting of RL self-integrating magnetic field sensor and differential amplifier was designed and fabricated. The frequency bandwidth of the magnetic flux density measuring system ranges from 200 Hz to 300 KHz and the response sensitivity was 0.126 $\mu$T/㎷ The distributions of the magnetic flux density near down-conductors due to impulse currents with various rise times were analyzed as a parameter of the bonding conditions and materials of conductor and wiring conduits. The magnetic flux density due to impulse currents was inversely proportional to the distance between the down-conductor and measuring point. The amplitude of the magnetic flux density for PVC Pipe with down-conductor was 72 $\mu$T/㎷ at the distance of 1m and was higher than for steel conduits and coaxial cable. Finally the magnetic flux density is increased with increasing the di/dt it and oscillation frequency of lightning currents in this experimental ranges.

Absolute calibration of near-infrared Period-Luminosity-Metallicity relations for RR Lyrae variables using Gaia EDR3

  • Bhardwaj, Anupam;Rejkuba, Marina;Yang, Soung-Chul
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.35.1-35.1
    • /
    • 2021
  • RR Lyrae stars are sensitive probe for the precision stellar astrophysics and also for the cosmic distance scale thanks to their well-defined near-infrared Period-Luminosity relations (PLRs). These horizontal branch variables can be used for primary calibration of the first-rung of population II distance ladder providing an evaluation of the ongoing tension between Cepheid-Supernovae based Hubble constant and the Planck results. Therefore, absolute calibration of RR Lyrae PLRs is now crucial to complement or test the tip of the red giant branch based distances, and in turn, population II star based Hubble constant measurements. While the pulsation models of RR Lyrae can reproduce most observables, they predict a significant metallicity effect on their JHKs-band PLRs that is inconsistent with so-far limited observational studies. We remedy this inconsistency of metallicity dependence in RR Lyrae PLRs by combining their near-infrared observations in the globular clusters of different mean-metallicities with the new parallaxes from the Gaia early data release 3 (EDR3). Our empirical results on Period-Luminosity-Metallicity (PLZ)relations are consistent with theoretical predictions but the precision of absolute calibrations is still affected by the parallax uncertainties and the systematic zero-point offset present in the Gaia EDR3.

  • PDF

The Effects of Visual Training on Binocular Anomalies (양안시 기능 이상의 시훈련(Visual Training)의 효과)

  • Kim, In-Suk;Hong, Dong-Gyun;Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.1
    • /
    • pp.53-61
    • /
    • 2005
  • In this study, we measured Near Point of Convergence(N.P.C) tests, Phoria tests using Von Grafe method and relative convergence tests on 138 men and 162 women, so a total of 300 subjects aged between 8~45 to examine the improvement of the fusion vergence through visual training and obtained as follows. 1. According to the results, the near point of convergence of 57 (19%) subjects were shorter than 7cm, and 243 (81%) were 7cm or longer, having a problem in convergence. After visual training, the number of subjects have the value shorter than 7 cm increased from 57 to 111 (37%), and the number of those have the value 7cm or longer decreased significantly form 243 to 189 (63%). 2. The results of the measure of lateral Phoria at far distance by Von Grafe method showed orthophoria 18 (6%), exophoria 198 (66%), esophoria 84 (28%). After phoria test, we examined the N.R.C and P.R.C test. The results showed that the hope finger was improved after V.T using B.l, B.O card. 3. The results of the measure of lateral Phoria at near distance by Von Grafe method showed orthophoria 6 (2%), exophoria 222 (74%), esophoria 72 (24%). After phoria test, we examine the N.R.C and P.R.C test. The results showed that the hope finger was improved after V.T using B.I, B.O card.

  • PDF