• Title/Summary/Keyword: Near infrared range

Search Result 351, Processing Time 0.023 seconds

The Color Matching Algorithm in Near Infrared Range for Military Camouflage (IR영역에서의 위장염색을 위한 칼라 매칭 알고리즘 연구)

  • Song Kyung-Hun;Yuk Jong-Il;Ha Hun-Seung;Lee Tae-Sang;You Young-Eun;Lee Si-Woo
    • Textile Coloration and Finishing
    • /
    • v.17 no.4 s.83
    • /
    • pp.7-14
    • /
    • 2005
  • The purpose of this study was to develop the color matching program with the excellent camouflage capacity in the near infrared range($\~$1100nm) including the visible light range for cotton fabrics. It was measured IR spectral reflectance in the range of $380\~1,100nm$ after dyed with vat dyes, and we made database for reflectance with various concentration on vat dyes which have a low reflectance value in the infrared range. The color matching algorithm that could be simulated in both the human visible light and the near infrared range was constructed by numerical analysis method using the database. In this study we also developed the dyeing conditions and dyeing process through the continuous-dyeing experiment with the vat dyes for cotton fabrics.

Evaluation of Drainage by Near Infrared Spectroscopy

  • Takamura, Hitoshi;Miyamoto, Hiroko;Mori, Yoshikuni;Matoba, Teruyoshi
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1271-1271
    • /
    • 2001
  • Water pollutants in drainage mainly consist of organic compounds. Hence, total organic carbon (TOC), chemical oxygen demand (COD), and biochemical oxygen demand (BOD) were generally used as the indices of pollution. However, these values are determined by special analyzer (TOC), titration method (COD), or microbe culture (BOD). Therefore, the development of simple and easy methods for the determination of water pollution is required. The authors reported the evaluation of water pollution by near infrared (NIR) spectroscopy in a model system with food components (Takamura et al. (200) Near Infrared Spectroscopy: Proceedings of 9th International Conference, pp. 503-507). In this study, the relationship between NIR spectra and drainage was investigated in order to develop a method for evaluation of drainage by NIR. Drainage was obtained in Nara Purification Center. The ranges of TOC, COD, and BOD were 0-130, 0-100 and 0-200, respectively. NIR transmittance spectra were recorded on NIR Systems Model 6250 Research Composition Analyzer in the wavelength range of 680-1235 and 1100-2500 nm with a quartz cell (light path: 0.5, 1, 2, 4 and 10mm) at 10-40. Statistical analysis was performed using NSAS program. A partial least squares (PLS) regression analysis was used for calibration. As the result, a good correlation between the raw NIR spectra and OC was obtained in the calibration. The best light path was 10 and 0.5mm in the wavelength range of 680-1235 and 110-2500nm, respectively. In the calibration, correlation coefficients(R) were 096-0.97 in the both range. In the prediction, however, a good correlation (R=0.89-0.96) was obtained only in the range of 6801235 nm, Similar results were obtained in the cases of COD and BOD. These results suggest the possibility that NIR spectroscopy can be used to evaluate drainage.

  • PDF

USE OF NEAR INFRARED FOR THE QUANTITATIVE ANALYSES OF BAUXITE

  • Walker, Graham S.;Cirulis, Robyn;Fletcher, Benjimin;Chandrashekar, S.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1171-1171
    • /
    • 2001
  • Quantitative analysis is an important requirement in exploration, mining and processing of minerals. There is an increasing need for the use of quantitative mineralogical data to assist with bore hole logging, deposit delineation, grade control, feed to processing plants and monitoring of solid process residues. Quantitative analysis using X-Ray Powder Diffraction (XRD) requires fine grinding and the addition of a reference material, or the application of Rietveld analysis to XRD patterns to provide accurate analysis of the suite of minerals present. Whilst accurate quantitative data can be obtained in this manner, the method is time consuming and limited to the laboratory. Mid infrared when combined with multivariant analysis has also been used for quantitative analysis. However, factors such as the absorption coefficients and refractive index of the minerals requires special sample preparation and dilution in a dispersive medium, such as KBr to minimize distortion of spectral features. In contrast, the lower intensity of the overtones and combinations of the fundamental vibrations in the near infrared allow direct measurement of virtually any solid without special sample preparation or dilution. Thus Near Infrared Spectroscopy (NIR) has found application for quantitative on-line/in line analysis and control in a range of processing applications which include, moisture control in clay and textile processing, fermentation processes, wheat analysis, gasoline analysis and chemicals and polymers. It is developing rapidly in the mineral exploration industry and has been underpinned by the development of portable NIR spectrometers and spectral libraries of a wide range of minerals. For example, iron ores have been identified and characterized in terms of the individual mineral components using field spectrometers. Data acquisition time of NIR field instruments is of the order of seconds and sample preparation is minimal. Consequently these types of spectrometers have great potential for in-line or on-line application in the minerals industry. To demonstrate the applicability of NIR field spectroscopy for quantitative analysis of minerals, a specific example on the quantification of lateritic bauxites will be presented. It has been shown that the application of Partial Least Squares regression analysis (PLS) to the NIR spectra can be used to quantify chemistry and mineralogy in a range of lateritic bauxites. Important, issues such as sampling, precision, repeatability, and replication which influence the results will be discussed.

  • PDF

A PRELIMINARY STUDY ON THE CHARACTERIZATION OF HONEY BY NEAR INFRARED SPECTROSCOPY

  • Davies, Anthony M.C.;Radovic, Branka;Fearn, Tom;Anklam, Elke
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1052-1052
    • /
    • 2001
  • Hear infrared (NIR) spectra were measured, at five temperatures, for forty-eight samples of honey, from a variety of geographical and botanical sources, and the data has been used to explore the possibility of using NIR spectroscopy for testing label claims concerning the geographical and botanical source of honey being offered for sale to the public. These results demonstrate that the successful characterization of the botanical source of a honey may be obtained by NIR spectroscopy. Further work with large numbers of samples and groups will be required to realized this potential. Additional analysis of these data suggest that research into new ways of obtaining information on the change of absorption with temperature might be beneficial for a range of technologies.

  • PDF

Thermal denaturation analysis of protein

  • Miyazawa, Mitsuhiro
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1628-1628
    • /
    • 2001
  • Near infrared (NIR) spectroscopy is a powerful technique for non-destructive analysis that can be obtained in a wide range of environments. Recently, NIR measurements have been utilized as probe for quantitative analysis in agricultural, industrial, and medical sciences. In addition, it is also possible to make practical application on NIR for molecular structural analysis. In this work, Fourier transform near infrared (FT-NIR) measurements were carried out to utilize extensively in the relative amounts of different secondary structures were employed, such as Iysozyme, concanavalin A, silk fibroin and so on. Several broad NIR bands due to the protein absorption were observed between 4000 and $5000\;^{-1}$. In order to obtain more structural information from these featureless bands, second derivative and Fourier-self-deconvolution procedures were performed. Significant band separation was observed near the feature at $4610\;^{-1}$ ,. Particularly the peak intensity at $4525\;^{-1}$ shows a characteristic change with thermal denaturation of fibroin. The structural information can be also obtained by mid-IR and CD spectral. Correlation of NIR spectra with protein structure is discussed.

  • PDF

Development of robust Calibration for Determination Sweetness of Fuji Apple fruit using Near Infrared Reflectance Spectroscopy

  • Sohn, Mi-Ryeong;Kwon, Young-Kill;Cho, Rae-Kwang
    • Near Infrared Analysis
    • /
    • v.2 no.1
    • /
    • pp.55-58
    • /
    • 2001
  • The object of this work was to investigate the influence of growing district and harvest year on calibration for sweetness (Brix) determination of Fuji apple fruit using near infrared (NIR) reflectance spectroscopy, and to develop the robust calibration across these variation. The calibration models was based on wavelength range of 1100∼2500 nm using a stepwise multiple linear regression. A calibration model by sample set of one growing district was not transferable to other growing districts. The combined calibration (data of three growing districts) predicted reasonable well against a population set drawn from all growing districts (SEP=0.69, Bias=0.075). A calibration model by sample set of one harvest year was not also transferable to other harvest years. The combined calibration (data of three harvest years) predicted well against a population set drawn from all harvest years (SEP=0.53, Bias=0.004).

Prediction of Soluble Solid and Firmness in Apple by Reflectance Spectroscopy

  • Park, Chang-Hyun;Judith.A.Abbott
    • Near Infrared Analysis
    • /
    • v.1 no.1
    • /
    • pp.23-26
    • /
    • 2000
  • The objectives of this study were to examine the ability to predict soluble solid and firmness in intact apple based on the visible/near-infrared spectroscopic technique. Two cultivars of apples, Delicious and Gala, were handled, tested and analyzed. Reflectance spectra, Magness-Taylor (MT) Firmness, and soluble solids in apples were measured sequentially. Maximum and minimum diameters, height, and weight of apples were recorded before the MT firmness tests. Apple samples were divided in to a calibration set and a validation set. The method of partial least squares (PLS) analysis was used. a unique set of PLS loading vectors (factors) was development for soluble solid and firmness. The PLS model showed good relationship between predicted and measured soluble solids in intact apples in the wavelength range of 860∼1078 nm. However, the PLS analysis was not good enough to predict the apple firmness.

Quantitative Analysis of Indomethacin by the Portable Near-Infrared (NIR) System (근적외분광분석법을 이용한 인도메타신의 정량분석)

  • 김도형;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.47 no.5
    • /
    • pp.261-265
    • /
    • 2003
  • Near-infrared (NIR) system was used to determine rapidly and simply indomethacin in buffer solution for a dissolution test of tablets and capsules. Indomethacin standards were prepared ranging from 10 to 50 ppm using the mixture of phosphate buffer (pH 7.2) and water (1 : 4). The near-infrared (NIR) transmittance spectra of indomethacin standard solutions were collected by using a quartz cell in 1 mm and 2 mm pathlength. Partial least square regression (PLSR) was explored to develop calibration models over the spectral range 1100∼1700 nm. The model using 1 mm quartz cell was better than that using 2 mm quartz cell. The PLSR models developed gave standard error of prediction (SEP) of 0.858 ppm. In order to validate the developed calibration model, routine analysis was performed using another standard solutions. The NIR routine analysis showed good correlation with actual values. Standard error of prediction (SEP) is 1.414 ppm for 7 indomethacin samples in routine analysis and its error was permeable in the regulation of Korean Pharmacopoeia (VII). These results show the potential use of the real time monitoring for indomethacin during a dissolution test.

Effects of Wearable Near-Infrared Rays on Knee Pain in Korean Elderly Adults

  • Lee, Jin-Min;Kim, Kye-Ha
    • Journal of Integrative Natural Science
    • /
    • v.13 no.4
    • /
    • pp.121-127
    • /
    • 2020
  • To investigate the effects of wearable near-infrared ray-emitting knee pads on knee pain among elderly adults in Korea. Randomized controlled trial evaluating the effects of near-infrared rays (NIR) on knee pain in Korean elderly adults. Five community-based research facilities (two welfare centers, a senior citizen center, and two churches). Forty-seven participants aged 65 years and older who had experienced knee pain. The experimental group (n = 25) wore NIR-emitting knee pads for one month at nighttime while sleeping. The control group (n = 22) wore knee pads without NIR. Demographic characteristics, intensity and duration of knee pain, amount of analgesic medication used, range of motion, gait speed, and health-related quality of life were collected using questionnaires. The experimental group showed decreased intensity (t = -6.17, p < 0.001) and duration (t = -3.34, p = 0.002) of knee pain and reduced analgesic use (t = -2.30, p = 0.026) compared to the control group. NIR may be an effective non-pharmacological option for relieving knee pain in elderly adults.

ESTIMATION OF SUGAR AND REDUCING SUGAR IN MOLASSES USING NEAR INFRARED REFLECTANCE SPECTROSCOPY

  • Mehrotra, Ranjana;Gupta, Alka;Tewari, Jagdish;Varma, S.P.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1258-1258
    • /
    • 2001
  • Estimation of sugar and reducing sugar content in molasses is very important task in sugar refineries. Conventional methods of determination of sugar content in molasses samples are highly time consuming and employ hazardous chemicals. Due to the physical properties of molasses, probability of error in conventional analytical techniques is high. These methods have proven to be inefficient for a process control in any sugar industry. Hence development of a rapid, inexpensive, physical and also accurate method for sugar determination in molasses will be highly useful. Near Infrared spectroscopy is being widely used worldwide as an analytical technique in food industry. The technique offers the advantage of being non-destructive and rapid. The present paper highlights the potential of near infrared reflectance spectroscopy as a rapid and automated analytical technique for determination of sugar and reducing sugar content in molasses. A number of molasses samples were collected during and after the sugar season from Havana Sugar Industry, Havana. The samples were chosen so as to obtain a wide range of concentration of sugar and reducing sugars. This was done in order to achieve a good calibration curve with widely spread data points. These samples were scanned in the region of 1100 - 2500 nm in diffuse reflectance mode. An indigenous ELICO NIR spectrophotometer, modified according to the requirements of sugar industry was used for this purpose. Each sample was also analyzed simultaneously by standard chemical methods. Chemical values were taken as reference for near infrared analysis. In order to obtain the most accurate calibration for the set of samples, various mathematical treatments were employed. Partial Least Square method was found to be most suitable for the analysis. A comparison is made between the actual values (chemical values) and the predicted values (NIR values). The actual values agree very well with the predicted values showing the accuracy of the technique. The validity of the technique is checked by predicting the concentration of sugar in unknown molasses samples using the calibration curve. The present investigation assesses the feasibility of the technique for on-line monitoring of sugars present in molasses in sugar industries.

  • PDF