• Title/Summary/Keyword: Nd-YAG

Search Result 1,085, Processing Time 0.026 seconds

Development of Nd-Yag Laser Marking System for Cylinderical Parts (Nd-Yag 레이저를 이용한 원통 형상 표면 마킹 시스템 개발)

  • Lee, Se-Han;Kang, Jae-Gwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.5
    • /
    • pp.70-75
    • /
    • 2010
  • In this paper, laser marking systems dedicated to cylinderical parts was developed. We first develop the marking device which consists of Nd-Yag laser, galvano scanner and additional rotational axis, then develop algorithm for supporting the digital image with bmp data format. Additional rotational axis is so attached as to rotate the cylinderical parts for marking its whole surface. The image is separated into line by line and the separated line image is sent to galvano scanner while rotating the additional axis simultaneously. CxImage library, famous open source code, is employed for the image processing. The developed method was tested with various images and shows that it reduces marking time significantly without reducing marking quality.

A study on the Second-Harmonic Generation(SBG) Conversion Characteristics of Nd:YAG Laser adopted Differential Superposition Mesh (중첩회로를 적용한 펄스형 Nd:YAG 레이저의 2차 SHG 변환효율에 관한 특성연구)

  • 김휘영;박두열
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.215-218
    • /
    • 2001
  • A pulsed Nd:YAG laser is used widely for materials processing and medical instrument. It's very important to control the laser energy density in those fields using a pulsed Nd:YAG laser. A pulse repetition rate and a pulse width are regarded as the most dominant factors to control the energy density of laser beam. In this paper, the alternating charge and discharge system was designed to adjust a pulse repetition rate. This system is controlled by microprocessor and allows to frequence an expensive condenser for high frequency to cheap one for low frequency. In addtion, The microcontroller monitors the flow of cooling water, short circuit, and miss firing and so on. We designed Nd:YAG laser firmware with smart microcontroller, and want to explain general matters about the firmware from now.

  • PDF

Optimum design and analysis of a diode side-primped Nd:YAG laser with a diffusive reflector (난반사체를 이용한 다이오드 횡여기 Nd:YAG 레이저의 최적화 설계 및 분석)

  • 이성만;윤미정;김선국;김현수;차병헌;문희종
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.6
    • /
    • pp.489-495
    • /
    • 2001
  • We developed a design code for a diode side-pumped Nd:YAG laser with a diffusive reflector to investigate the optimum design conditions resulting in homogeneous absorption distribution and efficient laser output power. By including the thermal tensing effect in the calculation of the laser output power, the calculated output powers were in fairly good agreement with the experimental results within the stable resonator condition. The calculation method can be used effectively for a diode side-pumped Nd:YAG laser in choosing the optimum design parameters and in predicting the laser output power.

  • PDF

EFFECT OF ND : YAG LASING ON TEMPERATURE RISING AND PROPERTIES OF MATTER OF DENTAL IMPLANTS (Nd : YAG LASER 조사가 치과 임플란트의 물성과 온도 상승에 미치는 영향)

  • Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.3
    • /
    • pp.489-500
    • /
    • 1996
  • Pulsed Nd : YAG LASER has been applied to various fields in clinical dentistry including the treatment of peri-implantitis. However, LASER can affect properties of matter of dental implants which are important to maintaining the health of peri-implant tissue and can raise its temperature during lasing. So there have been warings of using LASER to treat peri-implantitis. But, the effects of laser on dental implants itself are not certain yet. So we measured the temperature rising, examined matter of properties by SEM and EDX before and after pulsed Nd : YAG lasing various intensity. 7 TPS implants and 7 HPS implants were used and pulsed Nd : YAG LASER was used in 0.3W, 1.0W, and 2.0W. 1. 2.0W LASER made polished neck portion of HPS implants reach $39.2^{\circ}C$ after 5 seconds lasing. 2. LASER made crater-like defects on plasma sprayed surface and surfaces were melted and divided by fragments after lasing. 3. There was no specific evidence of element change after lasing.

  • PDF

A study on the improved efficiency of pulsed Nd:YAG laser adopted ZCC Method (ZCC 방식을 적용한 펄스형 Nd:YAG 레이저의 효율개선에 관한 연구)

  • Hong, Jung-Hwan;Moon, Dong-Sung;Jung, Jong-Han;Kim, Hwi-Young;Kang, Wook;Kim, Hee-je
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.220-221
    • /
    • 2000
  • 가공용 레이저로는 $CO_2$, 루비, Nd:YAG, 아르곤 이온 레이저 등이 이용되고 있으며, 이중 펄스형 Nd:YAG 레이저는 $CO_2$ 레이저와 함께 레이저 가공에 널리 사용되는 고체 레이저로서 마킹(making), 트리밍(trimming), 리페어링(repairing) 등의 정밀 가공 분야에서 많은 실용화가 이루어져 왔다.$^{(1)}$ $CO_2$ 레이저의 경우 매질가스로 $CO_2$, $N_2$, He 등을 사용해야하므로 취급 및 유지보수가 불편하지만, 열전도율이 높고, 기계적 광학적으로 안정된 Nd:YAG 레이저는 램프에 의한 광 여기 방식이므로 유지보수가 쉽다. 또한 광 출력의 제어가 용이하며, 광파이버에 의한 빔 전송이 가능하여 산업기술 및 의료 분야에서의 적용이 더욱 더 확대되고 있다.$^{(2)}$ (중략)

  • PDF

Cr:YAG 포화 흡수체를 이용한 Nd:YVO$_4$ 레이저의 수동형 Q-switching 특성

  • 이희철;김규욱;김칠민
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.42-43
    • /
    • 2001
  • Nd:YVO$_4$ 결정은 들뜬 상태의 발광 평균 수명이 90-100 $\mu\textrm{s}$로 아주 짧아서 Nd:YAG나 Nd:YLF 레이저 매질에 비해 짧은 펄스폭과 빠른 반복율을 가진 펄스들을 만들어 내는 Q-switching에 적합한 레이저 매질이다. 또한 Nd:YAG 결정에 비해 아주 큰 흡수 계수 및 이득 단면적을 지니고 있어 반도체 레이저로 펌핑하는 고체 레이저에 아주 적합한 레이저 이득 매질이다. (중략)

  • PDF

The Digital Controlled Implementation of the Resonant DC-DC Converter with High Voltage, High Frequency For Pulsed Nd:YAG Laser (고전압과 고주파수형 공진형 DC-DC 콘버터를 이용한 펄스형 Nd:YAG 레이저의 디지틸제어 구현)

  • Kim, Whi-Young
    • Proceedings of the IEEK Conference
    • /
    • 2001.09a
    • /
    • pp.777-783
    • /
    • 2001
  • This paper is mainly concerned with the state of the practical developments of a constants PWM bridge type resonants DC-DC suitable converter for Nd:YAG Laser with a Microprocessor. (PIC16C54 & 8051) The use of IGBT power supply with feedback control of flashLamp currents imparts a advantages to Nd:YAG Laser for materials processing. these include the alility to tailor the pulseshape and modify pulse parameters on a pulse- by pulse basis. And Correct choice of pulseshape can enhance the repeatability of the process. as higher power IGBT became available, act ive pulseforming power supplies will find greater user in deep hole drilling machine By Using certain control tecniques, utililized in designing Pic16c54 from Microchip technology and Intel 8051, also Mornitoring from Microsoft Visual Basic 5, And it allowed us to designed and fabricate ahigh repel it ion rate and high power(HRHP) pulsed Nd:YAG laser system, As a result of that, the current pulsewidth could be contort led 200s to 350s(step 50s) , and the pulse repetition rate could be adjusted 500pps to 1150pps. In addition, in the case of one laser head consisting of a Nd:YAG laser rod and two flashlamps , the maximum laser output of 240w was produced at the condition of 350s and 1150pps, and that of about 480w was generated at the same condition when two laser heads were arranged in cascade.

  • PDF

Development of high repetition rate and high power pulsed Nd:YAG laser power supply using ZCS resonant converter (ZCS공진형 컨버터를 적용한 고반복 대출력 펄스형 Nd:YAG 레이저 전원장치 개발)

  • Joe, K.Y.;Kim, E.S.;Byun, Y.B.;Kim, H.J.;Park, J.M.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.514-517
    • /
    • 1996
  • Zero current switching(ZCS) series resonant converter is used to control laser power density in a pulsed Nd:YAG laser power supply. The high power and high repetition rate paused Nd:YAG laser is designed and fabricated to control current pulse width and pulse repetition rate in the double elliptical laser oscillator. In order to find out operational characteristics of pulsed Nd:YAG laser, the electrical properties of driving power supply and laser output power are investigated and experimented by changing of the current pulse width from 200uS to 350uS(step 50uS) and pulse repetition rate range of 500pps(pulse per second) to 1150pps. From that result, we obtaind maximum efficiency of 1.83% and maximum laser output or 220W at the condition of 350 uS and 1150pps with one Nd:YAG rod), and obtained that of more than 400W with two laser head connecting series.

  • PDF

A Study on the Anesthetic Effects of Pulsed Nd:YAG Laser Irradiation to the Oral Mucosa and the Teeth (Nd:YAG 레이저 조사에 의한 치아 및 구강점막의 마취효과)

  • 최재갑
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.1
    • /
    • pp.1-9
    • /
    • 1998
  • The aim of the study was to evaluate the anesthetic Effecs of pulsed Nd:YAG laser irradiation to the oral mucosa and the teeth. Twenty subjects who didn't have a history of significant systemic or current oral disease were included in this study. All the subjects were divided randomly into the experimental group and the control group with 10 for each group. Pain thresholds were measured with Weighted Needle Pinprick Sensory Threshold Test for the mucosal surface of lower lip and with electric pulp test for the upper right central incisor respectively, before and immediately after pulsed Nd:YAG laser irradiation in the condition of 2 watt, 20pps for 2 minute at 10mm distance. The experiment was double-blinded clinical trial. The results were as follows : 1. The mean pain threshold of the mucosal surface of lower lip for Weighted Needle Pinprick Sensory Threshold Test was 2.94(1.00g for the contral group respectively, and there was no statistical difference between two groups. 2. The mean pain threshold of the mucosal surface of lower lip was significantly increased immediately after pulsed Nd:YAG laser irradiation. 3. The mean pain threshold of the upper right central incisor for eledtric pulp test was 34.50(4.97V in the experimental group and 34.00(13.08V in the control group respectively, and there was no statistical difference between two groups. 4. The mean pain threshold of the upper right central incisor was significantly increased immediately after pulsed Nd:YAG laser irradiation.

  • PDF

Effects of Acid-etching, CO2 and Nd:YAG Lasing on the Dentin Surface (산부식과 CO2 및 Nd:YAG 레이저 조사에 따른 상아질 표면의 변화)

  • Lee, Jae-Hak;Park, June-Sang;Ko, Myung-Yun
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.1
    • /
    • pp.129-144
    • /
    • 2000
  • The purpose of this study was to examine dentin surface changes of extracted sound third molar specimens which were etched with 10% maleic acid and irradiated at $7-140J/cm^2$ with $CO_2$ and at $156-280J/cm^2$ with Nd:YAG laser. The results were as follows. 1. Dentin surfaces etched with 10% maleic acid and then irradiated at below of $42J/cm^2$ with $CO_2$ laser showed the retentive morphology for resin restoration. 2. Dentin surfaces irradiated at below of $42J/cm^2$ with $CO_2$ laser showed the increased acid-resistance. 3. Dentin surfaces irradiated at $218-280J/cm^2$ with Nd:YAG laser showed the retentive morphology. 4. Dentin surfaces irradiated at $218-280J/cm^2$ with Nd:YAG laser and etched 10% maleic acid and then $218-280J/cm^2$ with Nd:YAG laser showed the increased acid-resistance.

  • PDF