• Title/Summary/Keyword: Nd:YAG

Search Result 1,085, Processing Time 0.031 seconds

THE EFFECT OF ND : YAG LASER IRRADIATION ON EXPOSURE OF THE DENTINAL TUBULES ON ROOT SURFACE IN EXTRACTED HUMAN TEETH;A SCANNING ELECTRON MICROSCOPIC STUDY (Nd : YAG laser 조사가 치근면 상아세관의 노출에 미치는 효과에 관한 주사전자현미경적 연구)

  • Cho, Jong-Hee;Kim, Byung-Ok;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.564-576
    • /
    • 1993
  • The purpose of this study was to evaluate the effects of Nd:YAG laser treatment on removal of smear layer and exposure of dentinal tubules. The experimental specimens were obtained from root planed surface of 30 human teeth which were extracted due to severe periodontal disease. The specimens were assigned randomly of three groups: root planed group, Tetracycline HCl(100mg/ml, 5min) group, and Nd:YAG laser ($Laser-35^{TM}$, U.S.A. 5 seconds )group. Nd:YAG laser group was divided into 4 subgroups according to 3.0W, 3.5W, 4.0W, 4.5W of power. The surface change of specimens were evaluated by scanning electron microscopy. The number of exposed dentinal tubules and percentage of area occupied by dentinal tubule orifices per unit area between each group was statistically analyzed by paired Student t-test. The results were as follows: 1. By root planing only, dentinal tubule was not exposed, but scale-like smear layer and parallel instrument tracks were resulted. 2. Tetracycline HCl treated surfaces exhibited the small number of partially exposed dentinal tubules with long orifices. The number($3.80{\pm}0.79$) of exposed dentinal tubules on Tetracycline HCl group was significantly less than that in laser groups above 3.5W of power(P<0.001), and the percentage ($0.68{\pm}0.19$) of area occufied by dentinal tubule orifices per unit area($192\;{\mu}m^2$) was significantly lower than that of any laser group(P<0.001). 3. The laser group irradiated with 4.5W of power showed both the most number($10.60{\pm}0.97$) of exposed dentinal tubules among the experimental groups, and the highest percentage($3.75{\pm}0.55\;%$) of area occupied by dentinal tubule orifices. 4. Energy Surge during laser pulsing and overlapping passes of the fiber resulted in melted and resolidified surface textures with lava-like appearance.

  • PDF

Two cases of bronchial leiomyoma resected by Nd-YAG laser under flexible bronchoscopy (Nd-YAG laser를 이용한 굴곡성 기관지경하 기관지 평활근종 절제 2예)

  • Kim, Hojoong;Kang, Woo Heon;Kang, Soo Jung;Chung, Man Pyo;Choi, Dong-Chull;Kwon, O Jung;Rhee, Chong H.;Han, Yong Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.6
    • /
    • pp.1028-1034
    • /
    • 1996
  • The leiomyoma of the bronchus is a very rare benign tumor in the lower respiratory tract. Though classical treatment of the bronchial leiomyoma is surgical resection, bronchoscopic tumor resection has been recently applied to selected cases. We experienced two cases of bronchial leiomyomas which were successfully resected under flexible bronchoscopy using Nd-YAG laser and bronchial snare. We speculated that bronchoscopic resection of the bronchial leiomyoma would be an effective and safe way of treatment, and more technical developments should follow.

  • PDF

Unidirectonal single-mode operation of a Nd:YAG laser by using a planar semimonolithic ring cavity (평면 반일체 고리형 공진기를 이용한 Nd:YAG 레이저의 단방향 단일 모드 발진)

  • 박종락;이해웅;윤태현;정명세
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.4
    • /
    • pp.311-317
    • /
    • 1999
  • Unidirectional single-mode operation of a diode-pumped Nd:YAG laser with a planar semimonolithic ring cavity has been demostrated at 1064 nm. The semimonolithic cavity consists of a laser active medium placed in a magnetic field, a crystal quartz plate, and an output coupling mirror. They form an optical diode by acting each part as a Faraday rotator, a reciprocal polarization rotator and a partial polarizer, respectively. An eigenpolarization theory for the cavity configuration was presented and losses for the eigenmodes were calculated. A pump-limited single-mode output power of 155 mW and a slope efficiency of 17% were obtained when the laser was pumped by a 1.2 W, 809 nm diode-laser. A laser linewidth of less than 100 kHz is inferred from a beat note frequency spectrum between two identical laser systems and continous single-mode tuning range was more than 2 GHz.

  • PDF

Carbon strain sensor using Nd: YAG laser Direct Writing (Nd:YAG Laser 직접 각인을 이용한 Carbon 스트레인 센서)

  • Joo, Donghyun;Yoon, Sangwoo;Kim, Joohan;Park, Woo-Tae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.1
    • /
    • pp.35-40
    • /
    • 2018
  • Nd:YAG laser was used to carbonize polyimide films to produce carbon films. This is a simple manufacturing process to fabricate low cost sensors. By applying this method, we studied characteristics of flexible and low-cost piezoresistive. Previously, many studies focused on carbonization of polyimide using $CO_2$ laser with wavelength of $10.6{\mu}m$. In this paper, carbonization (carbonization process) was performed on polyimide films using an Nd:YAG laser with a wavelength of $1.064{\mu}m$. In order to increase the resolution, we optimized the laser conditions of the power density ($W/cm^2$) and the beam scan rate. In previous studies using $CO_2$ laser, the minimum line width was $140{\sim}220{\mu}m$ but in this study, carbon line width was reduced to $35{\sim}40{\mu}m$. The initial sheet resistance of the carbon sensor was $100{\sim}300{\Omega}/{\square}$. The resistance decreased by 30% under stretched with a curvature radius of 21 R. The calculated gauge factor was 56.6. This work offers a simple, highly flexible, and low-cost process to fabricate piezoresistive sensors.

Finite Element Analysis of Nd:YAG Pulse Laser Welding for AISI 304 Stainless Steel Plate (AISI 304 스테인리스 강판의 Nd:YAG 펄스 레이저 용접에 관한 유한요소해석)

  • Nam Gi-Jeong;Kim Kwan-Woo;Hong Jin-Uk;Lee Jae-Hoon;Suh Jeong;Cho Hae-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.4 s.247
    • /
    • pp.428-434
    • /
    • 2006
  • Pulse laser welding of AISI 304 stainless steel plate was simulated to find optimal welding conditions by using commercial finite element code MARC. Due to geometric symmetry, a half model of AISI 304 stainless steel plate was considered and user subroutines were applied to boundary condition for the heat transfer. Material properties such as conductivity, specific heat, mass density and latent heat were given as a function of temperature. A moving heat source was designed on the basis of experimental data. As a result, Nd:YAG laser welding for AISI 304 stainless steel was successfully simulated and it should be useful to determine optimal welding condition.

Study of Defect Prevention on Weld Zone of Magnesium Alloy by Pulse Control of Nd:YAG Laser (Nd:YAG 레이저의 펄스 제어에 의한 마그네슘 합금 용접부의 결함 방지에 관한 연구)

  • Kim, Jong-Do;Lee, Jung-Han;Kim, Jang-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.1
    • /
    • pp.99-104
    • /
    • 2010
  • Magnesium and magnesium alloys, the lightest structural materials, have been received plenty of global attention recently. These alloys could be applied in various fields, especially the electronics industry, because of their excellent electromagnetic interference shielding. However, the welding technique of magnesium alloys has not been established. This study is related to the welding of AZ31B magnesium alloy by a short-pulsed a Nd:YAG laser. Two types of pulse waves, square pulse and variable pulse, were used to control weld defects. Results show that the crack and porosity, generated in the weld, had not been controlled by general square pulse. But through the application of variable pulse, the defects could be prevented and the good weld zone was obtained.

Dissimilar Metal Welding of SM45C and STS304 by means of CW Nd:YAG Laser (CW Nd:YAG 레이저를 이용한 SM45C와 STS304의 이종금속용접)

  • 신호준;유영태;임기건;안동규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1369-1375
    • /
    • 2004
  • For many years and primarily for economical reasons, Dissimilar Metal Welds have been used as transition joints in a variety of equipment and applications. But Dissimilar Metal Welds have several fabrication and metallurgical drawbacks that can often lead to in-service failures. For example, the most pronounced fabrication faults are hot cracks. Laser welding techniques have been characterised for various materials. In this paper, the laser weldability of STS304 stainless steel and SM45C at dissimilar metal welds using a continuous wave Nd:YAG laser are experimentally investigated. An experimental study was conducted to determine effects of welding parameters, on eliminating or reducing the extent welding zone formation at dissimilar metal welds and to optimize those parameters that have the most influence parameters such as focus length, power, beam speed, shielding gas, and wave length of laser were tested

  • PDF

Walk-off Output Characteristics of OPO Pumpedby SHG of Nd:YAG Laser (Nd:YAG 레이저의 SHG로 펌핑된 OPO의 Walk-off 출력특성)

  • 이용우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.419-423
    • /
    • 2003
  • In this paper, we have constructed singly resonant KTP OPO system pumped by 532 nm to obtain broadly frequency tunable pulses. Also we have mathematically simulated frequency tuning range, phase matching angle for 900 nm output and threshold energy, and we calculated output intensity using wave propagation equations for optical parametric oscillator which include walk-off, pump depletion.

  • PDF

A Study on Welding of Dissimilar Materials for Van-Ramp Design and Production (승합차의 램프 디자인과 제작을 위한 이종재료의 접합)

  • Lee, Jung-Hyun;Kim, In-Cheol
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.4
    • /
    • pp.434-439
    • /
    • 2011
  • There are about 2.4million disabled in Korea, 2009. Also, Korean society entered into an aging society. Therefore disable and elderly are getting more involved in our society. This study proposes simple ramp design for wheel chair users and welding method and condition for manufacturing. In the middle of ramp, screw jack and motor are installed so that ramp can be moved left and right side. To make the ramp moves easily, ramp was fixed by installing LM guide on both sides. Ramp production for using Nd:YAG laser certain dissimilar welding in stainless steel sheet and cold reduced carbon steel. The output was fixed by 3kW, the speed was increased to 2~7m/min, Argon was used as shielding gas and the flow rate was changed to 10~30L/min. The proper welding condition is the output 3kW and welding speed 2~5m/min.