• Title/Summary/Keyword: Nd:YAG

Search Result 1,085, Processing Time 0.024 seconds

A Plastic BGA Singulation using High Thermal Energy of $2^{nd}$ Harmonic Nd:YAG Laser

  • Lee, Kyoung-Cheol;Baek, Kwang-Yeol;Lee, Cheon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.2C no.6
    • /
    • pp.309-313
    • /
    • 2002
  • In this paper, we have studied minimization of the kerf-width and surface burning, which occurred after the conventional singulation process of the multi-layer BGA board with copper, polyethylene and epoxy glass fiber. The high thermal energy of a pulsed Nd:YAG laser is used to cut the multi-layer board. The most considerable matter in the laser cutting of the multi-layer BGA boards is their different absorption coefficient to the laser beam and their different heat conductivity. The cut mechanism of a multi-layer BGA board using a 2$^{nd}$ harmonic Nd:YAG laser is the thermal vaporization by high temperature rise based on the Gaussian profile and copper melting point. In this experiment, we found that the sacrifice layer and Na blowing are effective in minimizing the surface burning by the reaction between oxygen in the air and the laser beam. In addition, N2 blowing reduces laser energy loss by debris and suppresses surface oxidation. Also, the beam incidence on the epoxy layer compared to polyimide was much more suitable to reduce damage to polyimide with copper wire for the multi layer BGA singulation. When the polyester double-sided tape is used as a sacrifice layer, surface carbonization becomes less. The SEM, non-contact 3D inspector and high-resolution microscope are used to measure cut line-width and surface morphology.

THE SEM STUDY ABOUT THE MORPHOLOGICAL CHANGES OF THE DENTINAL SURFACE IRRADIATED WITH Nd : YAG LASER (Nd : YAG 레이저를 조사한 상아질 표면변화에 관한 주사전자현미경적 연구)

  • Lim, Sung-Sam;Yoon, Soo-Han;Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.479-489
    • /
    • 1997
  • The purpose of this study was to evaluate the effect of the Nd : YAG laser on the tooth hypersensitivity by the observation of the morphological changes of the dentinal surface irradiated with Nd : YAG laser by use of SEM. In 40 mandibular and maxillary molars without any carious lesion or restoration, severe attrition and abrasion, Enamel was removed with fine grit diamond bur and exposed dentinal surfaces were polished with Soflex discs. In control group (10 teeth), exposed dentinal surfaces were acid-etched with 10 % Maleic acid for 15 seconds. In the experimental group 1 (10 teeth), acid-etched dentinal surfaces with 10% Maleic acid were prepared by Nd : YAG laser (6 watts power, 1 psi water, 18 psi air) for 2 minutes. In the experimental group 2 (10 teeth), exposed dentinal surfaces were irradiated with Nd: YAG laser (10 watts power, 3 psi water, 10 psi air) until the painted black stains on the dentinal surfaces were completely removed. In the experimental group 3 (10 teeth). dentinal surfaces were prepared with Nd : YAG laser (6 watts power, 1 psi water, 18 psi air) until the painted black stanins on them were completely removed and then the irradiated dentinal surfaces were acid-etched with 10 % Maleic acid for 15 seconds. The specimens were routinely processed and observed with scanning electron microscope. The results were as follows : 1. In the irradiated dentinal surfaces, the characteristics of the melting and recrystalization on the dentinal surfaces were observed. Compared with the results in the control group, we could observe that in the irradiated dentinal surfaces, the aperture of the dentinal tubules were reduced and there were more debris obstructing the dentinal tubules. 2. In the irradiated dentinal surfaces, crater structures were commonly present and in the crater bottoms, there were a lot of bead like melted dentin structures, which had the ruptured opening in the center of them. 3. The melted dentins and cracks in the smear layer were less frequently observed in the irradiated dentinal surfaces using copious cooling water than in the irradiated dentinal surfaces using scare cooling water.

  • PDF

Nonlinear Absorption of Sc : Cr$^4+$:YAG Single Crystals (SC : Cr$^4+$:YAG 단결정의 비선형 흡수)

  • 유난이;김홍기;차명식;유영문
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.308-309
    • /
    • 2000
  • Nd:YAG 레이저의 수동적 Q-switching을 위해서는 대부분 유기물인 dye를 포화흡수체로 이용해 왔으나, 장시간 사용시 dye 분자의 결합이 끓어지면서 생기는 photodegradation으로 인하여 안정성에 많은 문제를 가지고 있다. 최근에 Cr$^{4+}$ :YAG 단결정의 물리적인 특성과 열적 안정성이 밝혀지면서 Nd:YAG 레이저의 Q-switching용 포화흡수체로 대치되고 있다[1]. 본 실험에서는 Z-Scan 방법을 이용하여 입사광의 세기에 따른 Cr$^{4+}$ :YAG 단결정의 흡수변화를 측정하였으며, 또한 Cr$^{4+}$ :YAG 단결정의 성장이 진행될수록 결정성장 길이에 따라 Cr 이온의 농도가 낮아지는 현상이[2] 발생하는데 두가지 서로 다른 결정화분률에 대해서 비선형 흡수를 비교하였다. (중략)

  • PDF

Development and Characterization of a 400-W Slab-type Nd:YAG Gain Module

  • Cha, Yong-Ho;Lee, Sungman;Lim, Gwon;Baik, Sung-Hoon;Kwon, Sung-Ok;Cha, Byung-Heon;Lee, Jung-Hwan;Kang, Eung-Cheol
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.53-56
    • /
    • 2012
  • We have developed a slab-type Nd:YAG gain module based on the techniques of conduction cooling and end pumping. The Nd:YAG slab is end-capped on both ends by undoped pure YAG and is pumped through the end-caps by stacked arrays of laser diode bars. The slab's surfaces of total internal reflection are in contact on both sides with microchannel cooling blocks which are cooled by water circulation. The power oscillator based on the gain module generates more than 400 W at 1-kW pumping with a slope efficiency of 55%. The small-signal gain of the gain module is 10 in a single zig-zag pass, and the amplified beam shows a near diffraction-limited beam quality.

A study on the pure Al weldability using a pulsed Nd : YAG laser (펄스형 Nd:YAG 레이저를 이용한 Al의 용접 특성연구)

  • 김덕현
    • Journal of Welding and Joining
    • /
    • v.11 no.1
    • /
    • pp.52-61
    • /
    • 1993
  • Laser welding of ASTM no. 1060 Al plate with a pulsed Nd: YAG laser of 200W average power was performed for end capping of KMRR nuclear fuel elements In this research, we performed basic welding experiments. Firstly, laser output parameters which affect laser welding parameters were studied by changing laser input parameters for effective welding of 1060 Al plates. We found that laser power density and pulse energy are important parameters for smooth bead shape. Secondly, welding parameters which affect weld width-to-depth ratio were studied by changing power density and pulse energy, shielding gas, and defocusing. We found that power density must be higher than 0.3 Mw/cm$^{2}$ pulse energy must be higer than 3 J. travel speed must not exceed 200mm/sec, laser focus must be existed beneath 2-3mm from plate surface and helium is proper shielding gas. Thirdly, we studied the weld defects of Al-1060 such as crack and porosity in lap-joint welding. We designed new welding geometry for crack free welding of Al-1060 plates, and obtained crack free weldment but with lack of fusion. However, with Ti, Zr grain refiner elements, we can weld Al plates without solidification hot crack. Finally, we studied the origin of porosity by changing shielding gas. And we found that porosity was resulted from entrapment of shielding gas by the collapsing keyhole.

  • PDF

TEMPERATURE CHANGES OF IMPLANT SURFACE IN SECOND STAGE SURGERY WITH DETAL LASER : IN VITRO STUDY (레이저를 이용한 임프란트 이차수술시 온도변화에 관한 실험적 연구)

  • Ahn, Hyun-Jeong;Kim, Hyoun-Chull;Choi, Byeong-Gap;Song, Eon-Hee;Kim, Rae-Gyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.256-268
    • /
    • 1999
  • Submerged implants require secondary surgical uncovering of implants after healing period of 3-6 months. In surgical methods, there are surgical scalpel, tissue punch, electro-surgical, and laser-used uncovering, and so forth The objectives of this study are investigation and assessment of 1) thermal change in clinical application for uncovering of HA-coated implant and pure titanium implant irradiated by pulsed Nd-YAG, $CO_2$, and Er-YAG laser. 2) surface change of cover screws aaer irradiation using laser energy. The temperature of apex & side wall of implants were recorded at 10sec, 20sec, 30sec after 30sec irradiation to implant healing screw; 1) pulsed Nd-YAG laser; 2W, 20pps, contact mode 2) $CO_2$ laser; water-infused & non-water infused state, 2.5-3.5W, contibuous mode, noncontact mode 3) $CO_2$ laser ; non-water infused state, 3W, superpulse, noncontact. mode 4) Er-YAG laser; (1) non-water infused state, 10pps, 60mj, contact mode (2) water-infused state, 10pps, 60mj, 80mj, 101mj, contact mode. According to the results of this study, pulsed Nd-YAG laser is not indicated because of increased thermal change and pitting of metal surface of implant cover screw. By contrast, $CO_2$ laser & Er-YAG laser are presumed to indicate because of narrow range of thermal change & near abscence of thermal damage of metal surface. Dental laser is thought to be much helpful to surgical procedure when it is used as optimal power and time condition considering characteristics and indications of each laser. Further research is needed to verify that these techniques are safe and beneficial to implant success.

  • PDF

Output characteristic analysis of the symmetric Nd:YAG laser consisted of two laser rods with rod-end curvatures (렌즈형 레이저 막대들로 구성된 대칭형 Nd:YAG 레이저의 출력 특성 분석)

  • Kim, Hyun-Su;Lee, Sung-Man;Rhee, Young-Joo
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.2
    • /
    • pp.198-202
    • /
    • 2006
  • Resonator stability condition, $M^2$ beam quality factor, and laser output power are analyzed for two types of two-rod Nd:YAC lasers with rod-end curvatures. Two laser rods with rod-end curvatures are positioned closely to each other or placed separately near each resonator mirror. Experimentally, the output powers and $M^2$ beam quality factors of those lasers are measured with and without thermal birefringence compensation, and compared to numerical analyses.

Multi-wavelength Dental Laser Development by Design Optimization of Optics, Cooling and Power systems (광학계, 냉각계, 전력계의 최적화에 의한 다파장 치과용 레이저 개발)

  • 윤길원;김홍식;전병문;이성근;이왕진
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.130-131
    • /
    • 2003
  • 수술용으로 쓰이는 치과용 레이저로는 Nd:YAG, $CO_2$, Er:YAG 레이저들이 있다. 치료 부위에 따라 두 가지 응용으로 나눌 수 있다. 잇몸의 절개 등은 주로 $CO_2$나 Nd:YAG 레이저를 이용하여 정밀하게 그리고 출혈을 최소로 하는 레이저의 장점을 살리면서 시술하고 있다. $CO_2$레이저의 경우 강한 열적 손상작용 때문에 출력 조사 시간을 짧게 하여 사용하며, 열적 손상력이 낮은 Nd:YAG 레이저는 화이버를 접촉식으로 하여 화이버의 작은 면적의 높은 광밀도를 이용하여 시술하고 있다. (중략)

  • PDF

Defects analysis of RE : YAG (RE = Nd3+, Er3+) single crystal synthesized by Czochralski method (Czochralski법으로 성장된 RE : YAG(RE = Nd3+, Er3+) 단결정의 결함분석)

  • Park, Cheong Ho;Joo, Young Jun;Kim, Hye Young;Shim, Jang Bo;Kim, Cheol Jin
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • RE : YAG ($RE=Nd^{3+}$, $Er^{3+}$) single crystals are laser diodes and generally grown by Czochralski method with controlling the various growth parameter. Since the defects occurred by temperature gradient or the rotation speed of solid-liquid growth interface act as the decline of crystal optical property during the growth procedure, crystalline quality improvement via defects analysis is necessary. The etch pit density (EPD) analysis was used to confirm the surface defect of grown RE : YAG single crystal and to select the area of transmission electron microscopy (TEM) analysis. Defects in the specimen produced by tripod polishing method such as buckling, rod shaped, bend contours by internal stress, segregation and others were observed by using 200 kV TEM and 300 kV FE-TEM.

Effects of Bronchoscopic Nd-YAG Laser Therapy in Tuberclous Tracheobronchial Fibrostenosis (기관 및 기관지결핵에 의한 반흔성 기도협착에 대한 기관지경적 Nd-YAG 레이저 치료의 효과)

  • Park, Jae-Yong;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.5
    • /
    • pp.494-503
    • /
    • 1994
  • Background: Fibrostenosis of large airway due to tuberculosis is one of the most perplexing clinical problems not only because it can lead to respiratory failure but also because of difficulty in the management. No one technique, such as balloon dilatation or insertion of self expandable metallic stent, has proved totally satisfactory in the management of fibrostenosis. We evaluated the effect of laser therapy in patient with severe fibrostenosis due to tuberculosis. Method: We classified the fibrostenosis to three types by bronchoscopic finding - the diaphragm type: stenosed by fibrous diaphragm, sparing the tracheobronchial wall, the collapse type: stenosed by collapse of the wall due to destruction of the cartilage, and the combined type: stenosed by nonspecific inflammatory scar tissue within internal lumen with collapse of the wall. We have treated 10 patients complaining dyspnea due to with severe fibrostenosis of the diaphargm or the combined type using a neodymiumyttrium aluminum garnet(Nd-Y AG) laser through a flexible bronchoscopy. Results: Eight of the 10 cases improved after laser therapy and maintained during a follow up period of average 31.9 months. All of the cases undergoing laser therapy showed no serious complication to need the therapy. Conclusion: The results of our present study indicate that the Nd-YAG laser therapy is an effective and safe method for the management of selective tuberculous fibrostenosis.

  • PDF