• Title/Summary/Keyword: Nb-Ti composite superconductor

Search Result 11, Processing Time 0.02 seconds

Fabrication of RRR Measuring System for Disseminating IEC International Standard (IEC국제규격을 보급하기 위한 RRR측정장치 제작)

  • Kyu Won Lee;Kyu Tae Kim
    • Progress in Superconductivity
    • /
    • v.4 no.1
    • /
    • pp.80-85
    • /
    • 2002
  • In order to disseminate the IEC international standard of RRR measurement of Cu/Nb/-Ti composite superconductors, a measuring system was developed at KRISS. The system consisted of helium reservoir, base plate, thermometer, voltmeter and current source. The helium reservoir and base plate provided a stable temperature of a range from 4.2 K to 300 K and the voltmeter measured several order of $mutextrm{V}$ on specimen for obtaining RRR of the Cu/Nb-Ti composite superconductor. Three specimens of the Cu/Nb-Ti composite superconductors were measured using this system for characterizing their RRR. The resistance-temperature curves ortho specimens showed 10/sup -6/ to 10/sup -5/ Ohms near transition temperature and 10/sup -4/ to 10/sup -3/ Ohms at 293 K. The RRR values of the specimens were 145, 71 and 140, respectively.

  • PDF

RRR Behavior due to Fatigue Damage in NbTi Superconductor Cable (피로손상을 받은 NbTi초전도 선재의 RRR거동패동)

  • 신형섭;배영준;하동우;오상수
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.1-5
    • /
    • 2001
  • In order to investigate the effect of fatigue damage on the properties of RRR in this study. fatigue tests at room temperature and residual resistivity measurement tests at 12K were carried out using annealed 9 strand Cu-Ni/NbTi/Cu composite cables Through fatigue tests of NbTi composite cables. a conventional S-N curve could be obtained even though there existed a possibility of fretting among strands, From the resistivity measurement of a NbTi strand after fatigue test, it was found that the RRR of xii·gin strand for annealed cables was 3 times more than that for as-received one. With increasing of fatigue cycles at a sress amplitude level. the RRR decreased. which was resulted from the accumulation of damage such as lattice defects and dislocation within the Cu stabilizer.

  • PDF

Standardization of Critical Temperature Measurement based on IEC International Standard

  • Lee, Kyu-Won;Kim, Kyu-Tae
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.123-127
    • /
    • 2003
  • For disseminating a ney IEC international standard of critical trmperature of NbTi,Nb$_3$Sn and Bi-2223 Composite Suterconductors, we develpted a measuring system and studied standardization of test method. The measuring system consisted of cryogenic reservoir, base plate, thermometer, voltmeter and current source. Various specimens of the Nbti, Nb$_3$Sn and Bi-2223 composite superconductors were tested using this system for measuring their critical temperatures. After measuring the resistance-temperature relation, the data were compensated with thermoelectric voltages for NbTi Nb$_3$Sn specimens. NbTi specimens showed 9.2 K ~ 9.5 K of transition temperature and Nb$_3$Sn specimen showed about 18 K. Bi-2223 specimens showed 104 K ~ 107 K of transition temperature.

RRR Behavior due to Fatigue Damage in a NbTi Superconductor Cable (NbTi 초전도 케이블의 피로손상에 따른 RRR의 거동)

  • 신형섭;배영준;하동우;오상수
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.30-33
    • /
    • 1999
  • In this study, the fatigue test at room temperature and residual resistivity measurement test at 12K were carried out, respectively, using a 9 strand Cu-Ni/NbTi/Cu composite cable, in order to investigate how the fatigue damage effects on critical properties. Through the fatigue test of a 9 strand Cu-Ni/NbTi/Cu composite cable, a conventional S-N curve was obtained even though there existed a possibility of fretting among strands. From the resistivity measurement of a NbTi strand after fatigue tests, it was found that with increase of the repeated number the RRR increased slightly, and the trend became significant with increase in maximum value of the applied stress amplitude.

  • PDF

Annealing effect on RRR Behavior due to Fatigue Damage in NbTi Superconductor Cable (피로손상을 받은 NbTi 초전도 선재의 RRR거동에 미치는 아닐링 효과)

  • 신형섭;오상엽;하동우;오상수
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.104-108
    • /
    • 2000
  • In this study, the fatigue test at room temperature and residual resistivity measurement test at 12K were carried out, respectively, using a 0 strand Cu-Ni/NbTi/Cu composite cable, in order to investigate how the annealing treatment effects on critical properties due to fatigue damage. Through a fatigue test of a 0 strand Cu-Ni/NbTi/Cu composite cables, a conventional S-N curve was obtained even though there existed a possibility of fretting among strands. From the resistivity measurement of a NbTi strand after fatigue tests, it was found that the RRR for annealed cables was 3 times more than that for as-received one, but with increase of the repeated number the RRR decreased which was resulted from the accumulation of damage such as lattice defects dislocation within the Cu stabilizer.

  • PDF

Analysis of Coupling Loss with Size and Material in the KSTAR PF Superconducting Coils (KSTAR PF 초전도자석의 크기 및 재료에 따른 결합손실 특성 분석)

  • Lee, H.J.;Chu, Y.;Lee, S.;Park, Y.M.;Park, H.T.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.1-5
    • /
    • 2009
  • It is important to predict AC loss in $Nb_3Sn$ and NbTi cable-in-conduit-conductor (CICC) reliably for the design and operation of large superconducting coils. The hysteresis loss in the superconducting filaments and coupling loss within strands and among strands in a cable or composite are dominant ac losses in superconducting magnets. The coupling loss in a superconductor can be characterized by identifying the coupling constant time $n{\tau}$. To reduce the coupling loss, all the strands (superconductor and Cu) in KSTAR (Korea Superconducting Tokamak Advance Research) are chromium plated with thickness of $l{\pm}0.5{\mu}m$. The ac losses of PF1, PF5 and PF6 coils has been measured by calorimetric method while applying trapezoidal current pulses with various ramp rate from 0.5 kA/s to 2 kA/s. The coupling time constants for $Nb_3Sn$ coils are $25{\sim}55$ ms and the values are not co-related with the coil size, the time constants for NbTi coil is 30 ms.

Evaluation of Mechanical Property and Fatigue Damage in A Practical Superconducting Cable for Magnet (초전도 마그네트용 실용 초전도 복합선재의 기계적 특성 및 피로손상 평가에 관한 연구)

  • Sin, Hyeong-Seop;O, Sang-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.3 s.174
    • /
    • pp.761-768
    • /
    • 2000
  • In order to investigate how the fatigue damage effects on the critical properties of superconductor, a fatigue test at room temperature and an Ic measurement test at 4.2K were carried out in this study, respectively, using a 9 strand Cu-Ni/NbTi/Cu composite cable. Through the fatigue test of a 9 strand Cu-NUNbTi/Cu composite cable, a conventional S-N curve was plotted even though there was a possibility of fretting among strands. It was found that the maximum stress corresponding to the inflection point on the S-N curve obtained was nearly the same value as the yielding strength of cable obtained from the static tensile test. However, the effect of cabling in multi-strands superconducting cable on the fatigue strength was not noticeable. The critical current(Ic) measurement was carried out at 4.2K in a NbTi strand out of the fatigued cable. It showed a degradation of lc at high stress amplitude regions over 380NTa, and the degradation became significant as the applied stress amplitude increased.

Magnetic $T_c$ Measurements of Composite Superconductors for a Standard Method (복합초전도체의 자기적 임계온도 측정의 표준화연구)

  • Lee K. W;Kim M. S;Kim D. H;Lee S. G
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.24-31
    • /
    • 2004
  • Magnetic $T_{c}$ of composite superconductors has been studied for providing a standard method. Various magnetization-temperature curves of NbTi, $Nb_3$Sn and Bi-2223 wires were measured using a SQUID magnetometer. Magnetization-temperature curve of zero-field-cooled procedure showed larger values than fie Id-cooled procedure. To obtain higher resolution near the onset temperature, we employed a two-field-direction method which measures a magnetization-temperature curve of a specimen first in positive and then negative fields. Analytical comparison of the magnetic $T_{c}$, with the resistive T$_{c}$ was accomplished for three specimens. The magnetic $T_{c}$/ mettled showed more detailed information on superconducting state of a specimen than the resistive$T_{c}$/ method. We have also studied the field dependence of the magnetic $T_{c}$ from 5 Oe to 120 Oe, however, no significant difference on field strength was found in our three specimensns

  • PDF

Standardization of the Critical Temperature Measurement by Using an AC Susceptometer

  • Lee, K. W.;Kim, M. S.;Kim, K.;Kim, D. H.;Lee, S. G.
    • Progress in Superconductivity
    • /
    • v.7 no.1
    • /
    • pp.22-27
    • /
    • 2005
  • We have studied the standardization of critical temperature measurements by using an ac susceptometer. Wire forms of NbTi, $Nb_{3}Sn$, and Bi-2223 superconductors were prepared to measure the temperature dependences of the magnetization. In order to study the optimum ac magnetic field and frequency, various amplitudes from 2 Oe to 10 Oe with frequencies from 11.3 Hz to 1033 Hz were applied to three specimens. Analytical comparison of the magnetic curves with the resistive curves was accomplished to investigate validity of using the new method.

  • PDF