• 제목/요약/키워드: Natural ventilation rate

검색결과 110건 처리시간 0.032초

구획모델을 이용한 주택에서 이산화질소의 발생강도 및 감소상수 동시 추정 (Estimation of Source Strength and Deposition Constant of Nitrogen Dioxide Using Compartment Model)

  • 양원호;손부순;손종렬
    • 한국환경보건학회지
    • /
    • 제31권4호
    • /
    • pp.260-265
    • /
    • 2005
  • Indoor air quality might be affected by source strength of indoor pollutants, ventilation rate, decay rate, outdoor level, and so on. Although technologies measuring these factors exist directly, direct measurements of all factors are not always practical in most field studies. The purpose of this study was to develop an alternative method to estimate the source strength and deposition constant by application of multiple measurements. For the total duration of 60 days, indoor and outdoor $NO_2$ concentrations every 3 days were measured in 30 houses in Seoul, Asan and Daegu. Using a compartment model by mass balance and linear regression analysis, penetration factor (ventilation divided by sum of air exchange rate and deposition constant) and source strength factor (emission rate divided by sum of air exchange rate and deposition constant) were calculated. Subsequently, the source strength and deposition constant were estimated. Natural ventilation was $1.80{\pm}0.42\;ACH,\;1.11{\pm}0.50\;ACH,\;0.92{\pm}0.26\;ACH$ in Seoul, Asan and Daegu, respectively. Calculated deposition constant(K) and source strength of $NO_2,$ in this study were $0.98{\pm}0.28\;hr^{1}\;and\;16.28{\pm}7.47\;ppb/h,$ respectively.

간척지 온실의 환기 및 냉방 특성 분석 (Analysis on the Characteristics of Ventilation and Cooling for Greenhouses Constructed in Reclaimed Lands)

  • 남상운;신현호
    • 생물환경조절학회지
    • /
    • 제26권3호
    • /
    • pp.181-187
    • /
    • 2017
  • 간척지 온실의 환경설계 기술 개발을 위한 기초자료 제공을 목적으로, 첨단 시설원예단지 설치 계획이 있는 국내 7개 대규모 간척지 주변의 기후조건을 분석하였으며, 새만금 간척지 내에 설치된 3연동 플라스틱 온실을 대상으로 하절기에 시설 내외의 열적 환경계측 실험을 통하여 자연환기 및 온도 상승 특성을 분석하고, 간척지 온실의 환경 설계에 적용해야 할 부분을 검토하였다. 작물의 유무에 따른 온실의 환기율을 비교한 결과, 작물이 있으면 온실의 환기율은 낮아지지만 작물의 증발산에 의해 실내기온 상승은 감소하는 것으로 나타났다. 작물이 있는 경우 온실의 환기회수는 대체로 0.3~0.9회/min의 범위에 있었고, 평균 0.7 회/min으로 나타났다. 실외기온 대비 실내기온 상승은 $1{\sim}5^{\circ}C$정도의 범위에 있었고, 평균 $2.5^{\circ}C$로 나타났다. 간척지에 설치된 실험온실의 자연환기 성능은 여름철 권장 환기율을 거의 만족시키고, 실외기온 대비 실내기온 상승도 작물재배 환경을 크게 벗어나지 않으므로 새만금 간척지에서는 냉방설비 없이 자연환기 만으로 온실의 작물 재배가 가능할 것으로 판단된다. 간척지는 해안에 위치하고 있어 내륙지역에 비하여 바람이 강하고, 안개가 자주 끼는 특성을 보이는 것으로 나타났다. 이와 같이 강한 풍속은 온실의 환기율을 증가시키므로 냉방부하의 감소요인으로 작용하게 될 것으로 판단된다. 또한 안개지속시간이 내륙지역에 비하여 현저하게 길기 때문에 기간냉방부하는 감소할 것으로 예상되며 이는 냉방설비의 운전경비 측면에서 유리할 것으로 판단된다. 또한 간척지 온실의 환기 및 냉방시스템 설계 시에는 주변의 기상관측소 자료를 그대로 이용하지 말고, 온실 설치 지역에서 실측한 기상자료 또는 현장 여건을 반영하여 보정된 기상자료를 사용하여 설계하도록 할 필요가 있다.

기계 환기시스템의 실내 환기성능 특성 해석에 관한 연구 (A Study on Characteristic Analysis for Indoor Ventilation Performance of Mechanical Ventilation System)

  • 구재현
    • 한국가스학회지
    • /
    • 제16권2호
    • /
    • pp.31-37
    • /
    • 2012
  • 본 연구는 실내 쾌적성 제어를 위하여 룸 에어컨의 환기성능을 분석한다. 실험장치는 환경공조챔버, 룸 에어컨, 추적가스 측정시스템, 급기팬과 제어기로 구성된다. 환기성능은 ASTM Standard E741-83 기준에 근거하여 환경공조챔버 내 CO2 추적가스기법을 사용한 체강법에 의해 재실자와 급기 환기량에 따라 평가된다. 급기 환기량 증가에 따라 환기성능이 증가함을 파악하였으며 재실자가 없는 경우 CO2 가스는 빠르게 감소하며 이때의 환기성능은 55%까지 증가한다. 그리고 1명의 재실자가 있는 경우 1시간 경과후 급기량 570 lpm에서 환기성능은 자연감쇠와 비교하여 25%까지 증가한다. 실험 데이터를 사용하여 환경공조챔버 내 룸 에어컨의 환기성능 모델링을 도출하였다.

전산유체역학을 이용한 표준 오리사 설계안에 대한 환기효율성 분석 (Analysis on Ventilation Efficiency of Standard Duck House using Computational Fluid Dynamics)

  • 여욱현;조예슬;권경석;하태환;박세준;김락우;이상연;이승노;이인복;서일환
    • 한국농공학회논문집
    • /
    • 제57권5호
    • /
    • pp.51-60
    • /
    • 2015
  • In Korea, 69.4 % of duck farms had utilized conventional plastic greenhouses. In this facilities, there are difficulties in controlling indoor environments for raising duck. High rearing density in duct farms also made the environmental control difficult resulting in getting more stressed making their immune system weaker. Therefore, a facility is needed to having structurally enough solidity and high efficiency on the environmental control. So, new design plans of duck house have recently been conducted by National Institute of Animal Science in Korea. As a study in advance to establish standard, computational fluid dynamics (CFD) was used to estimate the aerodynamic problems according to the designs by means of overall and regional ventilation efficiencies quantitatively and qualitatively. Tracer gas decay (TGD) method was used to calculate ventilation rate according to the structural characteristics of duck houses including installation of indoor circulation fan. The results showed that natural ventilation rate was averagely 164 % higher than typically designed ventilation rate, 1 AER ($min^{-1}$). Meanwhile, mechanically ventilated duck houses made 81.2 % of summer ventilation rate requirement. Therefore, it is urgent to develop a new duck house considering more structural safety as well as higher efficiency of environmental control.

연동형 비닐하우스의 환기창 형태 조사 및 자연환기 효과 분석 (Field Survey and Analysis of Natural Ventilation Characteristics of Multi-span Greenhouse with Different Roof Vent)

  • 박민정;최덕규;손진관;윤성욱;김희태;이승기;강동현
    • 생물환경조절학회지
    • /
    • 제29권1호
    • /
    • pp.36-42
    • /
    • 2020
  • 본 연구에서는 국내에 가장 많이 보급되어 있는 1-2W 모델 연동온실에 대한 온실 규격 및 환기창 형태 실태 조사를 수행하고, 이를 바탕으로 연동온실의 천창 형태에 따른 유동 특성을 분석하기 위해 수치해석을 수행하여 자연환기효과를 분석하고자 하였다. 온실 실태조사 대상농가의 환기창면적 비율은 평균10%로 자연환기를 위한 시설면적 대비 환기창 면적 설계가 부족한 것으로 나타나 환기창 개선이 필요할 것으로 판단된다. 연동 온실의 천창 형태별 자연환기를 해석 및 분석한 결과, 온실 내 작물위치의 온도 분포 및 내외부 온도차는 몽골식 천창 온실에서 가장 낮고 외몽골식 천창 온실에서 가장 높게 나타났으나 추후 풍하중에 의한 구조적인 안전성을 평가해야할 것으로 판단된다.

추적가스법을 적용한 국내 석회석 광산의 환기성능 평가 연구 (Ventilation Efficiency Evaluation of Domestic Limestone Mine Using Tracer Gas Method)

  • 김영수;노장훈;김진
    • 터널과지하공간
    • /
    • 제26권4호
    • /
    • pp.274-282
    • /
    • 2016
  • 현재 국내에서 가행 중인 석회석 광산은 자연환기력을 주된 환기방법으로 사용하고 있고, 대단면 굴착으로 매우 저속의 공기유동현상이 나타나고 있다. 이로 인하여 작업구간의 공기질이 매우 저하되어 있는 실정이다. 이러한 문제점들을 개선하기 위해서는 먼저 환기성능을 면밀하게 평가할 필요가 있다. 본 연구에서는 이러한 환기성능평가를 위해서 추적가스법을 적용하여 평가를 실시하였다. 연구 결과, 추적가스법을 통해 매우 저속의 공기유동, 공기재순환현상, 작업장 공기교환율 등을 정량적으로 평가함에 따라서 연구광산의 환기문제점들을 정밀하게 확인할 수 있었다. 이러한 추적가스법을 활용한 환기성능 평가방법은 광산의 작업환경 개선을 위하여 매우 정밀한 도구로 사용될 수 있음을 확인하였다.

아파트 실내공기질 현장측정에 의한 전열교환 청정환기유니트 성능평가 (IAQ Field Survey in an Apartment Housing Equiped for Heat Recovery Ventilation System with Air Cleaning Function)

  • 이정재;이중훈;이승민
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.688-693
    • /
    • 2005
  • Nowaday the natural ventilation rate decreases because the apartment housing is being air-tight. Therefore, Indoor Air Quality (IAQ) and indoor environment grow worse. Especially, Formaldehyde (HCHO), Volatile Organic Compounds (VOCs) which is emitted from the building materials and coating material etc. occur Sick House Syndrome that cause negative impact on resident's respiratory system and body. Therefore in construction field, it will be a important issues that development of a ventilation system with high effectiveness which can exhaust the contaminant out of the building quickly. In this research we evaluated 'wall attachable duct-less Heat Recovery Ventilation (HRV) system with air cleaning function'. We executed a synthetic evaluation about indoor air environment under various operating condition installing the system in real scale apartment house that is built in Anyang city. HRV system with air cleaning function showed good performance by removing HCHO, VOCs with less ventilation energy.

터널용 전기집진시스템 개발을 위한 방전극 설계 (Study on Discharge Electrode Design applied for Road Tunnel)

  • 김종률;원종웅;장춘만
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1238-1243
    • /
    • 2009
  • As Social Overhead Capital(SOC) has been expanded, the highway road construction has been accelerated and city road system has been more complicated. So, long road tunnels have been increased and traffic flow rate also has been raised. Accordingly, the exhausting gas of vehicle cars seriously deteriorates the tunnel inside air quality and driving view. In order to improve tunnel inside air quality, it is needed to introduce a compulsory ventilation system as well as natural ventilation mechanism. The former, that is, a special compulsory ventilation facility is very useful and helpful to prevent a tunnel of being contaminated by traffic in most case. In the case of obtaining clearer and longer driving view, the ventilation systems have to be considered in order to remove floating contaminants or exhaust gas from engines. In this paper, discharge electrode design technology will be discussed.

  • PDF