• 제목/요약/키워드: Natural velocity

검색결과 1,025건 처리시간 0.024초

A-mode 불안정성 영역에서 교란유동장에 놓인 원형실린더 후류의 천이지연과 유동공진의 발생 (Suppression of Wake Transition and Occurrence of Lock-on Downstream of a Circular Cylinder in a Perturbed Flow in the A-mode Instability Regime)

  • 김수현;배종헌;유정열
    • 대한기계학회논문집B
    • /
    • 제31권8호
    • /
    • pp.702-710
    • /
    • 2007
  • Direct numerical simulation (DNS) is performed to investigate suppressed wake transition and occurrence of lock-on in the wake of a circular cylinder disturbed by sinusoidal perturbation at the Reynolds number of 220 (A-mode instability regime). The sinusoidal perturbation, of which the frequency is near twice the natural shedding frequency, is superimposed on the free stream velocity. It is shown that the wake transition behind the circular cylinder can be suppressed due to the perturbation of the free stream velocity. This change causes a jump in the Strouhal number from the value corresponding to A-mode instability regime to the value corresponding to retarded wake transition regime (extrapolated from laminar shedding regime) in the Strouhal-Reynolds number relationship. As a result, vortex shedding frequency is locked on the perturbation frequency depending not on the natural shedding frequency but on the modified shedding frequency.

동부 심해 울릉분지의 천연가스 하이드레이트 (Natural gas hydrates in the eastern deep-water Ulleung Basin)

  • 류병재;김지훈;정부흥;이영주
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.610-612
    • /
    • 2008
  • Piston cores retrieved from the eastern part of the deep-water Ulleung Basin were analyzed to access the potential of hydrocarbon gas generation and natural gas hydrate (NGH) formation. Seismic data acquired in the study area were also analyzed to determine the presence of hydrocarbon gas and/or NGH, and to map their distribution. Core analyses revealed high total organic carbon (TOC) contents which favor hydrocarbon generation. The cores recovered from the southern study area showed the sufficient residual hydrocarbon gas concentrations for the formation of significant NGH. These cores also showed the cracks developed parallel to the bedding that suggest significant gas content in situ. A number of seismic blanking zones were observed on seismic data. They are identified as vertical to sub-vertical chimneys caused by the upward migration of pore fluid or gas, and containing of free gas and/or NGH. Often, they are associated with velocity pull-up structures that are interpreted to be the result of high-velocity NGH. The seismic data also showed several bottom-simulating reflectors (BSRs) that are associated with overlying NGH and underlying free gas. The distribution of blanking zones and BSRs would be impacted by the lateral differences of upward methane fluxes.

  • PDF

개인하수처리시설 처리수의 수질 개선을 위한 응집보조제로서의 천연제올라이트 적용에 관한 연구 (A Study on the Application of Natural Zeolite as Coagulant Aid for Effluent Quality Improvement in Private Sewage Treatment Facility)

  • 최정수;주현종
    • 한국물환경학회지
    • /
    • 제28권1호
    • /
    • pp.121-128
    • /
    • 2012
  • The purpose of this study is to solve the problem of nutrient removal due to rapid hydraulic retention time (HRT) variation in small size private sewage treatment facility and to have better effluent quality by using natural zeolite as a coagulant aid. The experiments were conducted by applying different conditions of HRT, coagulant, and zeolite dosages. As an experimental result, $TBOD_{5}$, TSS, and TP removal efficiencies were 64.9%, 94.5%, and 98.8% at co-injection with zeolite. Overall removal efficiencies of $TBOD_{5}$, TSS, and TP have improved 15.7, 28.7, 6.1%, respectively. This result shows that zeolite addition could improve flocculation, increase setting velocity, and thus have better treatment. Therefore the use of zeolite as a coagulant aid can be useful in small size private sewage treatment facility, where especially extra nutrient removal is required to meet the legal standard for discharge.

멤브레인형 LNG 수송선 코파담내의 난류 자연대류 (The Turbulent Natural Convection in Membrane Type LNG Carrier Cofferdam)

  • 정한식;정효민;김경근;노승탁
    • 대한기계학회논문집B
    • /
    • 제23권2호
    • /
    • pp.281-287
    • /
    • 1999
  • The turbulent natural convection in the membrane type LNG carrier cofferdam with heating points has been studied by numerical method. As the numerical methods, we introduced the three turbulence model, a standard $k-{\varepsilon}$ model and two case of a low Reynolds number models. The parameters considered for this study ore number and capacity of heating points i.e., $1{\leq}Ns{\leq}12$ and $1.0{\times}10^5{\leq}Qs(W/m^3){\leq}1.0{\times}10^8$. The results of the isotherms and velocity vectors have been represented for various parameters. The temperature and velocity at upper position in the space ore shown to be higher than those at lower position. For obtaining the optimal temperatures, $20{\sim}30^{\circ}C$ in the cofferdam space, the heating capacities show $2.0{\times}10^7W/m^3$ at g-heating points and $1.0{\times}10^7W/m^3$ at 12-points. The mean temperature in the cofferdam space can be expressed as a function of number and capacity of heating points.

Study on Condensation Heat Transfer Characteristics of Hydrocarbons Natural Refrigerants

  • Oh, Hoo-Kyu;Park, Seung-Jun;Park, Ki-Won;Roh, Geon-Sang;Jeong, Jae-Cheon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.10-17
    • /
    • 2001
  • This study investigated the condensation heat transfer coefficients of R-22, R-290 and R-600a inside horizontal tube. Heat transfer measurements were performed for smooth tube with inside diameter of 10.07 mm and outside diameter of 12.07 mm and inner grooved tube having 75 fins whose height is 0.25 mm. Condensation temperatures and mass velocity were ranged from 308K to 323 K and $51kg/m^2s$ to $250kg/m^2s$, respectively. The test results showed that the local condensation heat transfer coefficients increased as the mass flux increased, and also the effects of mass velocity on heat transfer coefficients of R-290 and R-600a were less than those of R-22. Average condensation heat transfer coefficients of natural refrigerants were superior to that of R-22. The present results had a good agreement with Cavallini-Zecchin's correlation for smooth and inner grooved tubes.

  • PDF

소량의 질소를 포함한 천연가스 수증기 개질 반응에서 GHSV 변화에 따른 암모니아 생성 반응에 관한 연구 (A Study on Ammonia Formation with Nitrogen Impurity at a Natural Gas Steam Reforming Catalytic Process)

  • 김철민;박상현;이주한;이상용
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.601-607
    • /
    • 2019
  • Ammonia would be formed in natural gas containing small amount of nitrogen reforming process in the process natural gas, which might damage the Pt catalyst and Prox catalyst. In the article, the effect of nitrogen contents on the formation of ammonia in the reforming process has been studied. In the experiments, Ru based and Ni based catalysts were used and the concentration of ammonia in the reformate gas at various gas hourly space velocity was measured. Experimental result shows that relatively higher ammonia concentration was measured with Ru based catalyst than with Ni based catalyst. It also shows that the concentration of ammonia increased rapidly after most of the methane converted into hydrogen. Based on the experimental results to reduce ammonia concentration it might be better to finish methane conversion at the exit position of the reforming reactor to minimize the contact time of catalyst and nitrogen with high concentration of hydrogen.

Thermal diffusion and diffusion thermo effects on an unsteady heat and mass transfer magnetohydrodynamic natural convection Couette flow using FEM

  • Raju, R. Srinivasa;Reddy, G. Jithender;Rao, J. Anand;Rashidi, M.M.
    • Journal of Computational Design and Engineering
    • /
    • 제3권4호
    • /
    • pp.349-362
    • /
    • 2016
  • The numerical solutions of unsteady hydromagnetic natural convection Couette flow of a viscous, incompressible and electrically conducting fluid between the two vertical parallel plates in the presence of thermal radiation, thermal diffusion and diffusion thermo are obtained here. The fundamental dimensionless governing coupled linear partial differential equations for impulsive movement and uniformly accelerated movement of the plate were solved by an efficient Finite Element Method. Computations were performed for a wide range of the governing flow parameters, viz., Thermal diffusion (Soret) and Diffusion thermo (Dufour) parameters, Magnetic field parameter, Prandtl number, Thermal radiation and Schmidt number. The effects of these flow parameters on the velocity (u), temperature (${\theta}$) and Concentration (${\phi}$) are shown graphically. Also the effects of these pertinent parameters on the skin-friction, the rate of heat and mass transfer are obtained and discussed numerically through tabular forms. These are in good agreement with earlier reported studies. Analysis indicates that the fluid velocity is an increasing function of Grashof numbers for heat and mass transfer, Soret and Dufour numbers whereas the Magnetic parameter, Thermal radiation parameter, Prandtl number and Schmidt number lead to reduction of the velocity profiles. Also, it is noticed that the rate of heat transfer coefficient and temperature profiles increase with decrease in the thermal radiation parameter and Prandtl number, whereas the reverse effect is observed with increase of Dufour number. Further, the concentration profiles increase with increase in the Soret number whereas reverse effect is seen by increasing the values of the Schmidt number.

연속형 천창을 가진 벤로형 온실의 자연환기 특성 분석 (Analysis of Natural Ventilation Characteristics of Venlo-type Greenhouse with Continuous Roof Vents)

  • 권진경;이성현;성제훈;문종필;이수장;최병민;김경자
    • Journal of Biosystems Engineering
    • /
    • 제36권6호
    • /
    • pp.444-452
    • /
    • 2011
  • In this study the characteristics of natural ventilation of Venlo-type greenhouse with continuous roof vents were analyzed using commercial computational fluid dynamics (CFD) code. Developed CFD simulation model was verified by comparison with experimental data. Simulation errors were 1.9-46.0% for air velocity and 1.7-11.2% for air temperature at each measurement point. CFD simulations were conducted to estimate the effect of roof vents opening direction, opening angle, outside wind velocity and wind directions on ventilation rate and climate condition in greenhouse. The results of this study showed that ventilation rate of the present greenhouse was increased linearly in proportion to the increase of roof vent opening angle and outside wind velocity over 2.0 m/s. According to the analysis on the effects of different roof vent opening direction, simultaneous opening of wind and leeward vents showed the highest ventilation rate and lowest mean temperature in greenhouse.

균일 유동장내 튜브 배열의 유동관련 진동에 관한 연구 (I) (A Study on Flow-Induces Vibration of Tube Array in Uniform Crossflow(I))

  • 이기백;김봉환;양장식;김문경;장석상
    • 대한기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.924-932
    • /
    • 1992
  • 본 연구에서는 풍동내에 놓여진 탄성지지 실린더의 와유출 특성과 진동 응답 을 동시에 측정하고 분석하여 유입속도 변화에 따른 이들의 상호관계를 확인하고 아울 러 실린더가 통과하는 풍동측정부에 있는 틈새 간격변화가 와유출과 실린더의 진동특 성에 미치는 영향에 대해 조사하였다.

도로터널에서 자연풍에 의한 미세물분무의 화재제어 특성에 관한 수치해석 연구 (A Numerical Study on the Fire Suppression Characteristics of a Water Mist with Natural Wind in a Road Tunnel)

  • 황철홍;김한수;이창언;장영남;신현준
    • 한국화재소방학회논문지
    • /
    • 제22권3호
    • /
    • pp.221-227
    • /
    • 2008
  • 본 연구에서는 FDS 코드를 이용하여 외부 자연풍에 의한 터널 내의 미세물분무 소화특성을 검토하였으며, 상세반응이 고려된 1차원 대향류 비예혼합화염을 이용하여 화염내부에서 미세물분무의 냉각 및 화학반응효과에 의한 소화현상을 규명하였다. 연구결과로서, 외부 자연풍의 유속 증가에 따라 고온 연기층의 분포 및 분무 특성의 큰 변화가 발생됨을 확인하였다. 외부 자연풍이 없는 경우에는 분무입자 직경이 작을수록 소화성능이 좋지만, 풍속이 증가함에 따라 입자직경이 클수록 소화성능이 좋아짐을 알 수 있었다. 자연풍은 입자의 화염면 침투를 방해할 뿐 아니라. 충분한 산소의 공급으로 화제 억제를 방해할 것으로 예측된다. 또한 자연풍이 존재하는 조건의 화염은 화염 신장효과에 의해 밀폐된 공간에서의 화염 보다 작은 양의 $H_2O$침투에 의해서도 소화될 수 있으며, $H_2O$의 화학반응에 의한 소화효과는 외부 자연풍의 유속에 크게 영향을 받지 않음을 확인하였다.