• Title/Summary/Keyword: Natural tooth

Search Result 298, Processing Time 0.023 seconds

ELASTIC CONSTANTS, SHEAR BOND STRENGTH OF TUNNEL RESTORATIVE MATERIALS AND MARGINAL RIDGE STRENGTH OF RESTORED TEETH (터널형 2급와동 충전재의 탄성계수와 전단결합강도 및 수복치의 변연융선 파절강도에 관한 연구)

  • Lee, Ka-Yean;Park, Yeong-Joon;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.3
    • /
    • pp.746-763
    • /
    • 1996
  • An alternative design to conventional class II cavity preparation for proximal carious lesions is the tunnel preparation. It preserves the marginal ridge intact, thus making it possible to maintain the natural contact relationship with the adjacent tooth and minimize tooth reduction. This in vitro study was purposed to evaluate the effect of the materials' elastic constants and shear-bond strength on the marginal ridge fracture resistance of teeth restored by the tunnel technique, and to find the materials of choice for tunnel restorations. $Resinomer^{(R)}$, $Ketac-silver^{(R)}$, $Miracle-Mix^{(R)}$, and Tytin were used as restorative material. The elastic constants of each restorative material were evaluated by ultrasonic pulse measurement. Young's modulus and bulk modulus of the restorative materials were evaluated in three specimens for each material type. The shear-bond strength of the restorative materials to the dentin surface was measured after thermocycling 400 times between 6 and $60^{\circ}C$, using ten specimens for each material type. For measuring marginal ridge strength, 60 sound extracted molar teeth were distributed into six groups by size. Sound molar teeth were used as a Control group and unfilled prepared teeth were grouped as Unrestored. Another four groups were named Resinomer group, Ketac-Silver group, Miracle Mix group, and Tytin group by type of restorative material. Tunnel cavity preparation was done with ' 1/2, 2, and 4 round burs in sequence. Initial access to proximal surface was made through an occlusal access preparation started at least 2mm from the marginal ridge, and the proximal opening was formed about 2.5mm below the marginal ridge. After restoration and thermocycling, marginal ridge strength was measured using a universal testing machine. The results were as follows: 1. The Young's modulus of $Tytin^{(R)}$ was 63.95 GPa, followed by $Ketac-Silver^{(R)}$ 27.60 GPa, $Miracle-mix^{(R)}$ 18.48 GPa, and $Resinomer^{(R)}$ 10.74 GPa showing significant differences between the groups(P<0.05). The bulk modulus of the materials showed the same order as Young's modulus. The value of $Tytin^{(R)}$ showed 59.57 GPa indicating that it will deform less than other materials under the same stress. It was followed by $Ketac-Silver^{(R)}$ 23.57 GPa, Miracle $Mix^{(R)}$ 12.50 GPa, and $Resinomer^{(R)}$ 11.60 GPa. 2. The Resinomer group had a shear-bond strength of 7.41 MPa which was significantly higher than those of the Ketac-Silver group (1.80 MPa) and the Miracle Mix group (2.84 MPa) (P<0.01). All the specimens of Tytin group detatched from the dentin surface during thermocycling. 3. The mean marginal ridge strength of the Unrestored group(46.14 kgf) was significantly lower than that of the Control group (84.24 kgf) (P<0.01). The marginal ridge strength of teeth restored by the tunnel technique was, in order, Ketac-Silver group 74.06 kgf, Miracle Mix group 73.36 kgf, Resinomer group 63.47 kgf, and Tytin group 58.76 kgf. The Ketac-Silver, Miracle Mix, and Resinomer groups showed no significant difference with the Control group (P>0.05), but the Tytin group showed significantly lower strength compared to the Control group(P<0.05). The results showed that the marginal ridge strength of the teeth restored by the tunnel technique was not significantly lower than that of sound teeth. They also demonstrated that the bonding strength of the restorative material to the tooth surface should be high and the modulus of elasticity should not be lower than that of the tooth in order to restore the marginal ridge strength to its natural condition.

  • PDF

Comparison Study of Wear Resistance Among Several Denture Teeth Opposing Various Restorative Materials (대합되는 재료에 따른 합성수지 인공치의 마모저항성에 관한 비교 연구)

  • Park, Young-Bae
    • Journal of Technologic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.63-74
    • /
    • 2009
  • Partial or complete prosthesis is needed when teeth are lost due to various kinds of reason. Artificial teeth recover occlusion instead of natural teeth. Artificial teeth are required of esthetics, fragile resistance and abrasive resistance. Artificial tooth is made of acrylic resin or porcelain. Nowadays, acrylic resin artificial teeth are mainly used. Acrylic resin teeth are occluded with natural teeth, gold alloy, Ni-Cr alloy or porcelain etc. Acrylic resin teeth have similar translucency, gloss of natural teeth. And it has good chemical bond with denture base material, but it has low wear resistance. The aim of this study is to compare wear resistance among several denture teeth(Endura, SR-orthosit-PE, Planustar) and between artificial resin denture teeth and opposing 3 restorative materials(gold, Ni-Cr alloy, porcelain). Wear tests were conducted with a rotating wear testing apparatus(pin-on-disk type wear tester) under conditions of rpm 180, 75 minutes and constant loading of 50N. The upper part was the cusp of maxillary first molar and the lower part was a disk type restorative materials. To make similar oral environment, water was supplied continually. The acrylic resin teeth wear was determined by weighing the cusp each 5 minutes during 75 minutes test. Vicker's hardness tester was used to evaluate the surface hardness of test specimens. The SEM was used to evaluate the wear surfaces. The results were as follows: 1. Wear rates of acrylic resin teeth opposing to the restorative materials were high in order of Porcelain, Gold, Ni-Cr alloy (p<.05). 2. Wear resistance rate opposing to the Porcelain disk, was shown in order of Endura, SR-orthosit-PE, Planustar. The wear rate of opposing to porcelain disk was above two times more than that of other groups (p<.05). 3. Wear resistance rates opposing to the Gold, Ni-Cr alloy disk, was shown in order of Endura, SR-orthosit-PE, Planustar (p<.05). 4. A degree of the surface hardness is directly proportional to the degree of wear resistance. There are statistically significant differences between each groups (p<.05).

  • PDF

The Change of Feeding Habits and Feeding Organ of Land-locked Plecoglossus altivelis (Pisces: Osmeridae), in Relation to Growth in the Lake Okjeong, Korea (옥정호 육봉형 은어 Plecoglossus altivelis(Pisces: Osmeridae)의 성장에 따른 식성 및 섭식기관의 변화)

  • Ko, Myeong-Hun;Kim, Ik-Soo;Park, Jong-Yeong;Lee, Yong-Joo
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.2
    • /
    • pp.337-345
    • /
    • 2007
  • Changes of feeding habitat and feeding organ of a land-locked sweetfish, Plecoglossus altivelis related to their growth process were investigated in the Lake Okjeong, Sannae-myeon, Jeongeup-si, Jeollabuk-do, Korea from 2004 to 2005. In the lake, the post-larvae from 25 to 40 mm in standard length fed mainly on animal organisms such as Copepoda, Branchiopoda and Rotatoria. Also, the juveniles from 50 to 60 mm (SL) fed on Chironomidae of Diptera, Copepoda and Branchiopoda. However, the juvenile from 60 to 70 mm (SL) in the Churyeong Stream fed on animal organisms and aquatic algae, the immature fishes more than 70 mm (SL) fed on only periphyton such as Synedra, Cymbella, Navicula and Pinnularia. Also, the feeding organs of the tooth and stomach were changed according to its growth and food change.

Bone-level implants placed in the anterior maxilla: an open-label, single-arm observational study

  • Gao, EnFeng;Hei, Wei-Hong;Park, Jong-Chul;Pang, KangMi;Kim, Sun Kyung;Kim, Bongju;Kim, Soung-Min;Lee, Jong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.5
    • /
    • pp.312-327
    • /
    • 2017
  • Purpose: This study assessed marginal bone remodeling and soft tissue esthetics after the loading of single bone-level implants in the anterior maxilla. Methods: An open, single-arm observational clinical trial with 3 years of follow-up was performed, including 22 implants. The patients presented with a single tooth gap in the anterior maxilla (tooth positions 14-24), with natural or restored adjacent teeth. An implant was placed at least 8 weeks post-extraction and healed submerged for 6 weeks. After the second-stage operation, a fixed provisional prosthesis was provided. The final restoration was placed 6 months after the provisional restoration. The time of the provisional crown connection was considered to be the baseline in this study. Esthetic parameters and the marginal bone level were assessed at 6, 12, 24, and 36 months. Results: All implants were well integrated in the bone. A statistically significant increase was found in the mean implant stability quotient between the time of the provisional prosthesis and the time of the final prosthesis. Most implants (95.5%) revealed marginal bone resorption (<0.5 mm), and just 1 implant (4.5%) showed a change of 2.12 mm from baseline to 36 months (mean $0.07{\pm}0.48mm$), while the crestal bone level decreased significantly, from $2.34{\pm}0.93mm$ at baseline to $1.70{\pm}1.10mm$ at 36 months. The facial gingival margin and papilla were stable and the esthetic scores indicated high patient and dentist satisfaction. Conclusions: Platform-switching bone-level implants placed in maxillary single-tooth gaps resulted in successful osseointegration with minimal marginal bone resorption. The peri-implant soft tissue was also esthetically satisfying and stable.

A STUDY ON THE MANDIBULAR ECCENTRIC MOVEMENT OF THE SUBJECTS WITH TMJ CLICK IN HORIZONTAL PLANE (측두악관절 잡음자의 수평면상 하악 편위 운동에 관한 연구)

  • Na, Kyung-Seon;Kang, Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.237-248
    • /
    • 1993
  • Although pantograph has been used to investigate whether the determinents of the mandibular movement were possible contributing factors of TMJ click, there was the problems to understand the role of tooth morphology upon the occurrence of click because of using appliance without tooth contacts. There Were advantages to evaluate the effects of tooth morphology upon the mandibular movements, because intraoral tracing device(Functiograph$^{(R)}$) had been obtained maintaining occlusal contact between the upper and lower natural teeth during mandibular movement. The purpose of this study was to record the mandibular eccentric movement quantitatively performed in 20 adult control subjects and 20 adult subjects with TMJ click and to investigate the effects of occlusion upon the occurrence of TMJ click. The obtained results were as follows : 1. The average ICP-P distance was $3.07{\pm}0.73mm$ in subjects with TMJ click, $2.14{\pm}0.85mm$ in control subjects. There was a statistical significance between subjects with TMJ click and control subjects(P<0.001). 2. The average ICP-P distance was $3.07{\pm}1.14mm$ in subjects with TMJ click, $2.61{\pm}0.96mm$ in control subjects. There was a statistical significance between subjects with TMJ click and control subjects(P<0.05). 3. The average distance of right and left lateral movement was not statistically significant between subjects with TMJ click and control subjects. 4. The average lateral displacement from midline during RCP was $0.75{\pm}0.54mm$ subjects with TMJ click, $0.16{\pm}0.17mm$ in control subjects. There was a statistical significance between subjects with TMJ click and control subjects(P<0.001). 5. The average lateral displacement from midline during protrusive movement was $0.88{\pm}0.54mm$ in subjects with TMJ click, $0.20{\pm}0.23mm$ in control subjects. There was a statistical significance between subjects with TMJ click and control subjects(P<0.001). 6. The average angle of right and left lateral movement was $144.2{\pm}20.20^{\circ}$ in subjects with TMJ click, $138.15{\pm}20.09^{\circ}$ in control subjects. There was a statistical significance between subjects with TMJ click and control subjects(P<0.05).

  • PDF

THE THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE PARTIALLY EDENTULOUS IMPLANT PROSTHESIS WITH VARYING TYPES OF NON-RIGID CONNECTION (부분 무치악 임플랜트 보철 수복시 자연치와의 비고정성 연결형태에 따른 3차원 유한요소법적 연구)

  • Lee, Seon-A;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.1
    • /
    • pp.101-124
    • /
    • 1996
  • In this study, we designed the finite element models of mandible with varying their connecting types between the prosthesis on implant fixture and 2nd premolar, which were free-standing case(Mf), precision attachment case(Mp), semiprecision attachment case(Ms) and telescopic case(Mt). The basic model of the designed finite element models, which contained a canine and the 1st & 2nd premolar, was implanted in the edentulous site of the 1st & 2nd molar by two implant fixtures. We applied the load in all models by two ways. A vertical load of 200N was applied at each central fossa of 2nd premolar and 1st implant. A tilting load of 20N with inclination of $45^{\circ}$ to lingual side was applied to buccal cusp tips of each 2nd premolar and 1st implant. And then we analyzed three-dimensional finite element models, making a comparative study of principal stress and displacement in four cases respectively. Three-dimensional finite element analysis was performed for the stress distribution and the displacement using commercial software(IDEAS program) for SUN-SPARC workstation. The results were as follows : 1 Under vertical load or tilting load, maximum displacement appeared at the 2nd premolar. Semiprecision case showed the largest maximum displacement, and maximum displacement reduced in the order of precision attachment, free-standing and telescopic case. 2. Under vertical load. the pattern of displacement of the 1st implant appeared mesio-inclined because of the 2nd implant splinted together. But displacement pattern of the 2nd premolar varied according to their connection type with prosthesis. The 2nd premolar showed a little mesio-inclined vertical displacement in case of free-standing and disto-inclined vertical displacement due to attachment in case of precision and semiprecision attachment. In telescopic case, the largest mesio-inclined vertical displacement has been shown, so, the 1st premolar leaned mesial side. 3. Under tilting load, The pattern of displacement was similar in all four cases which appeared displaced to lingual side. But, the maximum displacement of 2nd premolar appeared larger than that of the first implant. Therefore, there was large discrepancy in displacement between natural tooth and implant during tilting load. 4. Under vertical load, the maximum compressive stress appeared at the 1st implant's neck. Semiprecision attachment case showed the largest maximum compressive stress, and the maximum compressive stress reduced in the order of precision attachment, telescopic and free-standing case. 5 Under vertical load, the maximum tensile stress appeared at the 2nd implant's distal neck. Semiprecision attachment case showed the largest maximum tensile stress, and the maximum tensile stress reduced in the order of precision attachment, telescopic and free-standing case. 6. Under vertical load or tilting load, principal stress appeared little between natural tooth & implant in free-standing case, but large principal stress was distributed at upper crown and distal contact site of the 2nd premolar in telescopic case. Principal stress appeared large at keyway & around keyway of distal contact site of the 2nd premolar in precision and semiprecision attachment case, appearing more broad and homogeneous in precision attachment case than in semiprecision attachment case.

  • PDF

Fractal analysis of peri-implant bone density surrounding implant with different state of antagonist (대합 조건에 따른 임플란트 주변 골밀도 변화에 대한 프랙탈 구조 분석)

  • Kim, Ju-Hee;Lee, Jae-In
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.14-20
    • /
    • 2016
  • Purpose: The aim of this study was to know whether there is significant difference of peri-implant bone density according to the state of antagonist region. Materials and methods: 51 patients who had implant operation in Daejeon Dental Hospital of Wonkwang University participated in this study and total of 51 implants were analyzed. Implants were classified depending on opposing antagonist region, gender, age and location of jaw. The opposing antagonist region was divided into four groups; natural tooth, implant, pontic and edentulous region. Fractal analysis was performed using two periapical radiographs; one after implant placement and the other after 10 weeks following prosthetic restoration. The analysis was done by Image J. The data was statistically analyzed using one-way ANOVA and Tukey multiple comparison test. Results: The mean value of fractal difference was $0.009{\pm}0.048$ with opposing natural tooth, $0.026{\pm}0.080$ with opposing implant, $0.025{\pm}0.068$ with opposing pontic and $0.093{\pm}0.171$ with opposing edentulous area. There was a statistically significant difference in fractal value between opposing implant and opposing edentulous state. And there was no statistically significant difference according to age, gender and location of jaw. Conclusion: There was no statistically significant difference between 3 groups except opposing edentulous region and there was a statistically significant difference between opposing implant and edentulous region. And there was no statistically significant difference according to age, gender and location of jaw.

Fabrication of surveyed crown and repairing the artificial teeth for existing removable partial denture using digital technology: a case report (디지털 방식을 이용한 기존 국소의치 맞춤 보철 제작과 심미적인 인공치 수리 증례)

  • Ina Kim;Eunji Oh;Sang-Won Park;Hyun-Pil Lim;Kwi-dug Yun;Chan Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.82-90
    • /
    • 2024
  • It often happens that a removable partial denture needs to be repaired due to tissue changes in the remaining alveolar ridge, fracture of the denture, or fracture of the abutment tooth. There are several advantages to retrofitting a customized surveyed crown under the existing RPD. Retrofitting a crown to the RPD decreases the economic burden to the patient and avoids the need for several appointments to fabricate a new RPD. It is difficult for artificial teeth used to repair dentures due to fractured natural teeth to have a shape similar to that of natural teeth, and to repair aesthetic artificial teeth, it is necessary to manufacture customized artificial teeth similar to the shape of each patient's teeth. Recently, CAD/CAM technology has been used to fabricate customized prosthetics on existing RPD to achieve high retention and fitness accuracy, and by manufacturing customized artificial teeth, more aesthetic and harmonious artificial tooth repair is possible. This is a case in which a denture was repaired using a digital method to fabricate a customized prosthesis on an existing partial denture and customized artificial teeth that mirrored the adjacent dentition, saving time and cost, simplifying the process, and achieving aesthetically and functionally satisfactory results.

Antimicrobial Activities and Adherence Inhibition on Streptococcus mutans by Ethyl Acetate Extract from Caesalpinia sappan L. (소목(Caesalpinia sappan L.)의 에틸아세테이트 분획물이 Streptococcus mutans에 대한 항균활성 및 부착 억제)

  • Kwon, Hyun-Jung;Kim, Yong-Hyun;Han, Kook-Il;Jeon, Mi-Ae;Han, Man-Deuk
    • Journal of dental hygiene science
    • /
    • v.12 no.2
    • /
    • pp.155-162
    • /
    • 2012
  • Somok, the heart wood of Caesalpinia sappan is used in traditional Chinese medicine. Adherence of S. mutans to the tooth surface can result in the formation of a dental plaque. This study was performed to investigate the antibacterial activity and bacterial adhesion of ethyl acetate extract from C. sappan against S. mutans ATCC 25175. The bacteria were cultured in brain heart infusion(BHI) broth, and then incubated under 5% $CO_2$ at $37^{\circ}C$ for 18~24 hours. The antimicrobial activity of the ethyl acetate extract of C. sappan was then examined using the paper disc methods and MIC. In addition, bacterial adherence to hydroxyapatite was also examined. The ethyl acetate extract was shown to produce inhibitory effects and had MIC values of 125 mg/ml against S. mutans ATCC 25175. The ethyl acetate extract inhibited adhesion of S. mutans to saliva coated-hydroxyapatite beads(S-HA). At 24 hr, the ethyl acetate extract significantly reduced the adherence of S. mutans to S-HA beads relative to the control. The isolated active substance was identified as brazilin($C_{16}H_{14}O_5$) by $^1H-NMR$ and $^{13}C-NMR$. Thus, the application of C. sappan can be considered a useful and practical method for the prevention of dental caries.

Complications of implants confronting the extruded posterior teeth (정출된 구치와 대합되는 임플란트의 합병증)

  • Jung, Yeon-Wook;Lee, Su-Yeon;Kim, Hee-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.232-241
    • /
    • 2020
  • Purpose: This study investigated the complications and patterns of implants that confronted with the extruded natural teeth. Materials and Methods: Among patients who received implant treatment between 2006 and 2018 at Chosun University Dental Hospital, only implants that had a maintenance period of at least 5 years and that both implants and confronting natural teeth could be measured and compared on a radiograph were selected. They were divided into two groups. Group 1, experimental group consisted of Implants confronting the extruded natural posterior teeth (n = 167: maxilla (Group 1max) = 92, mandible (Group 1man) = 75) and Group 2, control group consisted of Implants confronting the normal natural posterior teeth (n = 656: maxilla (Group 2max) = 272, mandible (Group 2man) = 384). Results: The incidence of complications between Group 1 and Group 2 was statistically significant. In particular, there was a statistically significant difference between the frequency of marginal bone loss and the amount of marginal bone loss. Conclusion: The extruded natural tooth may cause more frequent complications including bone resorption in the opposing implant.