• 제목/요약/키워드: Natural refrigerant

검색결과 100건 처리시간 0.026초

R-290, R-600a의 수평 이중관형 열교환기내 증발 특성 (Evaporating Heat Transfer Characteristics of R-290, R-600a Inside Horizontal Double Pipe Heat Exchangers)

  • 홍진우;노건상;권옥배;박기원;오후규
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.309-314
    • /
    • 2000
  • Experimental results for heat transfer characteristics of natural refrigerants R-290, R-600a and HCFC refrigerant R-22 during evaporating inside horizontal double pipe heat exchangers are presented. The experimental apparatus is basically a vapour heat pump system, composed of a compressor, a condenser, expansion devices, a evaporator, and some other peripheral devices. The test sections were horizontal double pipe heat exchangers, which were a pair of smoothed tube, having 10.07 mm ID, 12.07 mm OD, and grooved inner fin tube, having 12.70 mm OD, 0.25 mm fin height, and 75 fins. The local evaporating heat transfer coefficients of natural refrigerants were not much affected with the mass velocity than R-22 and it could be interpreted that the local evaporating heat transfer coefficients of R-22 were increased more than those of R-290, R-600a according to the increment of mass velocity. Moreover, the maximum increment of the heat transfer coefficient was found in R-290. The average heat transfer coefficient was obtained the maximum value in R-290 and the minimum value in R-22. It reveals that the natural refrigerant can be used as a substitute for R-22. In the grooved inner fin tube, 70% of the increment of the heat transfer coefficient was obtained compared to the smoothed tube.

  • PDF

자연냉매인 CO2를 이용한 냉동탑차 냉장시스템과 핵심부품개발에 관한 연구 (A Study of Development of Regrigerated Truck Small Scale Cooling System and Key-Part using Natural Refrigerants.)

  • 정세진;박성신;민호기;조가영
    • 한국가스학회지
    • /
    • 제23권1호
    • /
    • pp.19-26
    • /
    • 2019
  • 본 연구에서는 친환경적 냉매로 주목받고 있는 이산화탄소 자연 냉매를 이용하여 1톤 크기의 냉동 탑차에 들어가는 냉방 시스템을 개발하고, COP를 올리기 위해 열교환기 및 Unit cooler를 설계하였다. 또한 LNG의 기존 CNG 5톤 냉동탑차를 LNG 차량으로 개조하여 냉방시스템의 효율을 높임과 동시에 CNG 대비 안전성을 확보하였다. 결과적으로 1톤 및 5톤 크기에서 자연 냉매를 사용한 친환경적인 냉동탑차를 개발하였다.

프로필렌 냉매의 응축열전달 특성에 관한 실험적 연구 (Condensing Heat Transfer Characteristics of Propylene Refrigerant)

  • 이호생;김재돌;윤정인
    • 설비공학논문집
    • /
    • 제16권7호
    • /
    • pp.639-644
    • /
    • 2004
  • This paper deals with the heat transfer characteristics of R-1270 (Propylene), R-600a (Iso-butane) and R-290 (Propane) as an environment friendly refrigerant and R-22 for condensing. The experimental apparatus has been set-up as a conventional vapor compression type heat pump system. The test section is a horizontal double pipe heat exchanger. A tube diameter of 12.70 mm with 1.32 mm wall thickness is used for this investigation. The test results showed that the local condensing heat transfer coefficients of hydrocarbon refrigerants were higher than that of R-22. The average condensing heat transfer coefficient was obtained with the maximum value in R-1270 and the minimum one in R-22. Comparing the heat transfer coefficient of experimental results with that of other correlations, the presented results had a good agreement with the Cavallini-Zecchin's correlation. It reveals that the natural refrigerants can be used as substitute for R-22.

차량용 에어컨에 사용되는 냉매 및 냉동기유의 기술 동향 (Development Trends of Refrigerant and Refrigerant Oil for Automotive Air-conditioner)

  • 이대웅;황승용
    • Tribology and Lubricants
    • /
    • 제35권4호
    • /
    • pp.206-214
    • /
    • 2019
  • This study investigates alternative refrigerants and refrigerant oils as well as the tendency of protecting the global environment in view of automobile air-conditioning systems. Since decades, the R12 refrigerant is not used in automobile air-conditioners because of the ozone depletion potential (ODP) problem, and for the last 20 years, the ODP-free R134a refrigerant is leading the new automotive air-conditioning market. However, owing to its high global warming potential (GWP), the R134a refrigerant use in automobile air-conditioning system is also prohibited by law, and alternative refrigerants with a low GWP need to be proposed. Therefore, recently, the application of R1234yf, R152a, or other alternative refrigerants has started worldwide. By contrast, natural refrigerant R744 was introduced in the market several years ago by VDA (Verband Der Automobilindustrie), which is a German association in the automotive industry. This study also deals with refrigerant oils. For a long time, polyalkylene glycol (PAG) oil has been traditionally used with automobile air-conditioners, and polyolester (POE) oil is suitable for HEV, PHEV, and EV air-conditioning systems, where it is used by the electrically driven compressor owing to its excellent electrical insulation properties. Finally, PAG is an excellent lubricant for all the R134a, R152a, R1234yf, and R744 refrigerants, and has the advantage that it can be applied rapidly to alternative refrigerant air-conditioning systems.

천연냉매인 이산화탄소의 세관 유동시 발생하는 증발 유동 현상에 대한 수치해석 연구 (Numerical Study on the Evaporation Flow Phenomena of Natural Refrigerant CO2 through Small Diameter Tubes)

  • 최인수;박병덕
    • 한국산업융합학회 논문집
    • /
    • 제10권2호
    • /
    • pp.89-96
    • /
    • 2007
  • For the environment protection, carbon dioxide as a natural refrigerant has been studied to use in an automotive air conditioning system. Hence, a numerical model has been developed to describe the evaporation phenomena of carbon dioxide flowing through very small diameter tubes. The two dimensional low-Reynolds $k-{\varepsilon}$ model was used to predict the flow phenomena of carbon dioxide in the two phase during its evaporation. Furthermore, the results obtained from the model were compared with the experiments for the validation. The heat transfer coefficient is lower, as the tube inner diameter becomes smaller. However, the amount of heat absorbed by a unit mass of carbon dioxide is greater due to more surface area. Therefore, the small diameter tube has advantage in terms of compact design of evaporator. When the inlet condition of pressure and temperature is low, the heat transfer coefficient is slightly high at the same size of tube because of the thermal properties of carbon dioxide.

  • PDF

CO2용 사판식 압축기 성능 해석 (Performance Analysis of the Swash Plate Type Compressor using CO2 Refrigerant)

  • 이건호;박익서
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.564-569
    • /
    • 2005
  • Recently, from the viewpoint of global wanning, natural gas CO2 is considered as a main refrigerant for hot water system. The characteristics of CO2 is not toxic, not flammable, high pressure, and high refrigerating capacity. Also it is widely available as a byproduct of industrial processes. This paper describes the performance analysis program of the swash plate type compressor using CO2 refrigerant. Estimates of the refrigerant flow rate, compression work, discharge temperature and volumetric, compressor efficiencies of the CO2 swash plate type compressor are obtained from the various design parameter such as the inclination angle of the swash plate, discharge hole area and suction hole area.

  • PDF

Current State and Future of Refrigerants for Refrigeration and Air Conditioning

  • Kagawa, Noboru
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권4호
    • /
    • pp.182-190
    • /
    • 2007
  • Refrigeration and air-conditioning equipments are indispensable products in this civilized society. However, discharged refrigerants used in the equipments and exhausted carbon dioxide to drive the refrigeration and air-conditioning equipments are related to serious environmental problems and energy problems. Especially, the destroyed ozonosphere by the discharged refrigerants and the increased normal temperature by carbon dioxide and fluorocarbon refrigerants (green house gases) are sounded as serious global problems. For alleviating these problems, environmental-friendly refrigeration and air-conditioning equipments must be developed and will spread soon. To develop new equipment, a suitable refrigerant for each usage must be presented. In this paper, the current state of refrigerants was introduced. And, thermophysical properties of the refrigerants were introduced briefly. From the properties, the refrigerants and refrigeration cycles are promising to be used in the future, were proposed

암모니아 대체 자연냉매를 이용하는 2단압축 1단팽창 냉동시스템의 성능예측 (Performance Analysis of 2-Stage Compression and 1-Stage Expansion Refrigeration System using Alternative Natural Refrigerants)

  • 노건상
    • 한국가스학회지
    • /
    • 제16권3호
    • /
    • pp.42-47
    • /
    • 2012
  • 본 논문에서는 규제 프레온냉매 R22의 대체 자연냉매의 후보인 R290(프로판), R600(부탄), R717(암모니아), R1270(프로필렌)을 작동유체로 사용하는 2단압축 1단팽창 냉동시스템의 성능 특성을 비교하였다. $-20^{\circ}C{\sim}-50^{\circ}C$ 정도의 저온을 얻기 위해 사용되는 2단압축 1단팽창 냉동장치에서의 증발온도, 응축온도, 과열도 및 과냉각도의 변화에 따른 성능계수(COP) 변화를 규명하고자 하였다. 성능특성 규명 결과, 과냉각도 및 중간냉각기에서의 냉매유량 증가에 따라 시스템의 COP는 증가하였으나, 증발온도, 응축온도 및 과열도가 증가할수록 COP는 저하되는 결과를 나타내었다. 또한, 자연냉매를 사용하는 2단압축 1단팽창 냉동시스템의 COP는 규제 프레온냉매 R22를 사용하는 경우보다 높기 때문에 자연냉매를 사용하고자 하는 냉동시스템의 안전성이 확보되면 충분히 대체 냉매로서의 경쟁력이 있을 것으로 판단되었다.

혼합냉매 혼합비에 따른 천연가스 액화공정 성능 비교 (Determination of Mixing Ratio of Mixed Refrigerants and Performance Analysis of Natural Gas Liquefaction Processes)

  • 김민진;이경범;유준
    • Korean Chemical Engineering Research
    • /
    • 제51권6호
    • /
    • pp.677-684
    • /
    • 2013
  • 혼합냉매를 사용하여 천연가스를 액화하는 혼합냉매공정(Mixed refrigerant cycle, MRC)은 공정이 간단하고 장치비가 적게 들며 운전 또한 용이하여 널리 채택되고 있는 공정이다. MRC에서 중요한 기술 중 하나는 혼합냉매를 선택하고 최적의 혼합비를 결정하는 것이다. 본 연구에서는 일반적인 MRC에서 혼합냉매와 혼합냉매의 혼합비가 공정의 성능에 미치는 효과를 살펴보았다. 이를 위해 통계적 기법 중 실험계획법의 하나인 혼합물 설계와 반응 표면법을 이용하여 전체 공정의 에너지 소비가 최소가 되게 하는 최적의 냉매를 선택하고 그 혼합비를 결정하였다. 여러 냉매와 혼합비에 따른 MRC 공정의 모사는 Aspen HYSYS를 사용하였으며 혼합물설계와 반응 표면법은 Minitab을 사용하였다. 연구결과 냉매로는 methane ($C_1$), ethane ($C_2$), propane ($C_3$)과 nitrogen ($N_2$)가 선택되었으며 에너지 소비를 최소화하는 혼합비(몰 비) 또한 구할 수 있었다.

프로판 냉매를 활용한 단일 및 다단 냉동 사이클의 전산모사 비교 연구 (A comparative study on the simulation of single-stage and multi-stage refrigeration cycle using propane as a refrigerant)

  • 노상균
    • 한국산학기술학회논문지
    • /
    • 제15권5호
    • /
    • pp.3327-3335
    • /
    • 2014
  • 본 연구에서는 천연가스의 냉각을 위한 프로판을 냉매로 사용한 단일 및 다단 냉동 사이클에 대한 소요 에너지를 비교하였다. 이를 위해서 천연가스의 온도를$ -37.00^{\circ}C$까지 냉각시키기 위해서 프로판을 냉매로 사용하여 1단 압축 및 2단, 3단, 4단 압축을 이용한 냉동 사이클에 대한 비교 연구를 수행하였다. 전산모사를 위해 한국가스공사로부터 제공받은 천연가스 조성을 적용하였으며, 열역학 모델식으로는 Peng-Robinson 상태방정식을 적용하였다. 냉동기 압축 단수가 증가할수록 응축기의 heatduty는 점점 줄어드는 것을 알 수 있었다. 4단 압축공정의 경우 1단 압축공정에 비해 응축기의 heatduty는 약 20.36% 정도 감소하였으며 냉매의 총 순환 유량은 약 14.53% 감소하였다. 또한 4단 압축공정의 경우 1단 압축공정에 비해 압축기의 총 소요 동력은 약 41.61% 감소함을 알 수 있었다.