• Title/Summary/Keyword: Natural Vibration Frequency

Search Result 2,155, Processing Time 0.03 seconds

Modeling free vibration analysis of osteon as bone unite

  • Ebrahimi, Farzad;Zokaee, Farin
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.5 no.1
    • /
    • pp.1-10
    • /
    • 2020
  • This paper investigated vibrational behavior of the osteon as bone unit in the different situations. This study can lead to increase our knowledge of our body. In this paper free vibration of the osteon with considering it as composite material has been studied. The effect of numbers of lamellae and radius of those on natural frequency of osteon are subtle; while thickness of lamellae have decreasing trend on natural frequency of osteon. The presence of nerve and blood in haversian canal change trend of natural frequency, absolutely. Using the nonlocal strain gradient theory(NSGT) leads to effectiveness of scale parameter on equations of motion and the obtained results. The governing equations are derived by Hamilton's principles. A parametric study is presented to examine the effect of various parameters on vibrational behaviour of osteon. The results can also be regarded as a benchmark in vibration analysis behavior of osteon as bone unite.

Structural Vibration Analysis of Electronic Equipment for Satellite under Launch Environments (발사환경에 대한 인공위성 전장품의 구조진동 해석)

  • 박태원;정일호;한상원;김성훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.768-771
    • /
    • 2003
  • The impulse between launch vehicle and atmosphere can generate a lot of noise and vibration during the process of launching a satellite. Structurally, electronic equipment (KOMPSAT 2, RDU : Remote Drive Unit) of a satellite consists of aluminum case containing PCB (Printed circuit boards). Each PCB has resistors and IC (Integrated circuits). Noise and vibration of wide frequency band are transferred to the inside of fairing, subsequently creating vibration of the electronic equipment of the satellite. In this situation. random vibration can cause malfunctioning of the electronic equipment of the device. Furthermore, when tile frequency of random vibration meets with natural frequency of PCB. fatigue fracture nay occur in the part of solder joint. The launching environment, thus. needs to be carefully considered when designing the electronic equipment of a satellite. In general. the safety of the electronic equipment is supposed to be related to the natural frequency, shapes of mode and dynamic deflection of PCB in the electronic equipment. Structural vibration analysis of PCB and its electronic components can be performed using either FEM(Finite Element Method) or vibration test. In this study. the natural frequency and dynamic deflection of PCB are measured by FEM, aud the safety of the electronic components of PCB is being evaluated according to the results. This study presents a unique method for finite element modeling and analysis of PCB and its electronic components. The results of FEA are verified by vibration test. The method proposed herein may be applicable to various designs from the electronic equipments of a satellite to home electronics.

  • PDF

Effect Investigation of Resonance by Harmonic Components on Structures with Velocity Seismoprobes in a Turbine Rotor System (속도계가 부착된 구조물에서 조화성분의 공진이 미치는 영향 고찰)

  • Yang, Kyeong-Hyeon;Cho, Chul-Whan;Bae, Chun-Hee;Song, Oh-Seop
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.98-102
    • /
    • 2005
  • Most bearing casings are designed to focus on strength and weight of themselves because rotor speed passes through the critical speed when operation begins in large plants such as power plants. And It is treated importantly the relation between rotating frequency of the rotor and the natural frequency of casings to prevent resonance. But there is some cases that it is overlooked for harmonic components above rotating frequency. So we present experimentally a case that harmonic forces may make a resonance on casing fixing probes to measure vibration in a turbine-generator system and the vibration is generated when one component of harmonic forces excites the mode that the natural frequency of a certain bearing casing is close to one of harmonics of basic rotating frequency (1x).

  • PDF

Optimization for the Natural Frequency of the TFT-LCD Glass Plate with Multi-Support Point (다점지지된 TFT-LCD 유리기판의 고유진동수 최적화)

  • Lee, H.S.;Lee, Y.S.;Kim, H.S.;Lee, J.W.;Lee, S.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.246-249
    • /
    • 2005
  • The TFT-LCD is extensively used from a small watch to a large TV display, and the demand is increasing rapidly. The size of R-LCD glass plate becomes more bigger, and the thickness become more thinner with high demands. As a result natural frequency of the TFT-LCD glass plate becomes more lower. The TFT-LCD glass plate will be moved by robot arm and may receive effect of vibration that occur at transfer. Natural frequency of the TFT-LCD glass plate is increased or decrease according to location that robot arm fixs glass plate. Purpose of a this study is finding support location that optimize the first natural frequency of TFT-LCD glass plate. The size optimization method of ANSYS 8.0 is used as the optimization tool search on the optimal support location of TFT-LCD glass plate. The considered number of support point is from 4 to 9.

  • PDF

Analysis of Natural Frequency According to Span of Foot-bridges (보도교의 구조시스템별 고유진동수 분석)

  • Do, Ki Young;Yoon, Sung Won
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.5
    • /
    • pp.375-383
    • /
    • 2014
  • In Seoul, total 166 places of foot-bridges were constructed but a study on correlation between resonance occurrence status by gait vibration and natural frequency by each span and that between span based on structural system and natural frequency is very unsatisfactory in reality. Consequently in this study, time series wave form, power spectrum and natural frequency were analyzed based on resonance occurrence by targeting 65 places of foot-bridges being constructed in Seoul through convenient and simple portable vibration meter.

Natural frequency analysis of tractor tire with different ground contacts and inflation pressures

  • Cuong, Do Minh;Sihong, Zhu
    • Coupled systems mechanics
    • /
    • v.9 no.5
    • /
    • pp.455-471
    • /
    • 2020
  • This paper presents the results of the study of vertically natural frequency of tractor tires are effected by changing different ground contacts and inflation pressures using the Free Decay Method. The results show that the natural frequencies of the tire are not affected while the vertical acceleration increased strongly due to the increase of inflation pressure when the tire performs free decay vibration on rigid ground. In addition, the number of natural frequency peaks of the tire also increases with increasing tire inflation pressure. On the other hand, the natural frequencies of the tractor tire increases strongly while the vertical acceleration decreases slightly with the increase of tire inflation pressure as the tire performs free decay vibration on soft soil. Further, the natural frequencies of tire-soil system are always higher than that of tire only, and it changed with changing the soil depth. Results also show the natural frequency of tire and tire-soil system is in the range of 3.0 to 10.0 Hz that lie within the most critical natural frequency range of the human body. These findings have to be mentioned and used as design parameters of the tractor suspension system.

A Study on the Dynamic Characteristics of Composite Deck Plate According to the Modification of Boundary Conditions (경계조건의 조절에 따른 합성 데크플레이트 슬래브의 거동특성에 관한 연구)

  • 김우영;정은호;엄철환;김희철
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.371-376
    • /
    • 1998
  • As the requirement of high-rise buildings in big cities increases, steel structural system becomes more popular in spite of the relatively higher material cost compared to that of the concrete structural system. Most of the steel structure adopts metal deck floor system because of the easiness in construction. However, the metal deck floor system has a weakness on vibration which became very important factor in office buildings, hotels and residential buildings as the more sensitive machines being used. Therefore, most, of the building codes in many countries restrict the natural frequency of the each floor should be higher than or equal to 15 Hz. Floor vibration of the KEM deck composite floor system which has been , developed recently from the engineers and scientists in Korea was measured. Also, the simplified analytical derivation of natural frequency for each floor was studied according to the measured natural frequency for each different boundary condition of the floor. As the length of the slab gets bigger, the natural frequency of the slab becomes lower even though the structural designer still considers it as a one-way slab.

  • PDF

Prestress-Loss Monitoring Technique for Prestressd Concrete Girders using Vibration-based System Identification (진동기반 구조식별을 통한 프리스트레스트 콘크리트 거더의 긴장력 손실 검색 기법)

  • Ho, Duc-Duy;Hong, Dong-Soo;Kim, Jeong-Tae
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.123-132
    • /
    • 2010
  • This paper presents a prestress-loss monitoring technique for prestressed concrete (PSC) girder structures that uses a vibration-based system identification method. First, the theoretical backgrounds of the prestress-loss monitoring technique and the system identification technique are presented. Second, vibration tests are performed on a lab-scaled PSC girder for which the modal parameter was measured for several prestress-force cases. A numerical modal analysis is performed by using an initial finite element (FE) model from the geometric, material, and boundary conditions of the lab-scaled PSC girder. Third, a vibration-based system identification is performed to update the FE model by identifying structural parameters since the natural frequency of the FE model became identical to the experimental results. Finally, the feasibility of the prestress-loss monitoring technique is evaluated for the PSC girder model by using the experimentally measured natural frequency and numerically identified natural frequency for several prestress-force cases.

3-D Vibration Characteristics of Radial Tire for Passenger Car under Fixed Axle (축으로 고정된 승용차용 레디얼 타이어의 3차원 진동특성)

  • 김용우;남진영
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.3
    • /
    • pp.228-235
    • /
    • 2002
  • Two kinds of experimental modal analyses have been performed on a radial tire for passenger car under fixed axle. One is the modal analysis to obtain three-dimensional modes of tire using accelerometers and the other is the one to identify cavity resonance frequency using a pressure sensor. From the first analysis, we have obtained three-dimensional natural modes and their decomposed 3-D modes in each direction, which make it possible to grasp the features of the modes that cannot be identified in the conventional 2-D modes and to classify the vibrationall modes into symmetric, non-symmetric, and antisymmetric modes in a simple way by using the experimental results. From the second experimental analysis, the cavity resonance frequency is found. Coomparing the results of the two analyses, we have Identified the three-dimensional mode of the cavity resonance. We also haute shown that natural frequencies of structural vibration depends on inflation Pressure while the cavity resonance does not.

Study on vibration characteristics of low pressure turbine hood resonance in a 500MW thermal power plant (500MW 화력발전소 저압터빈 Hood 공진 특성에 관한 연구)

  • Cho, Cheul-Whan;Cho, Seong-Tae;Koo, Jae-Raeyang;Kim, Hyoung-Suk
    • Journal of Power System Engineering
    • /
    • v.17 no.3
    • /
    • pp.23-27
    • /
    • 2013
  • In this research paper, we study on how to decrease the high vibration of turbine hood casings which are main facilities of power generation industry. Cause of Standard coal-fired power 500MW facilities turbine hoods' high vibration is that Natural frequency of hood casing designed in near domain frequency, when they are making hoods. We investigate to reduce high vibration at hood casing. We use FEM method to found how to avoid resonance, and test to confirm that our FEM result. We Finally attach minium mass plate at hood casing to avoid resonance and high vibration reduce lower $100{\mu}m$.