• Title/Summary/Keyword: Natural Movement

Search Result 720, Processing Time 0.022 seconds

Compensation for Fast Head Movements on Non-intrusive Eye Gaze Tracking System Using Kalman Filter (Kalman filter를 이용한 비접촉식 응시점 추정 시스템에서의 빠른 머리 이동의 보정)

  • Kim, Soo-Chan;Yoo, Jae-Ha;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.6
    • /
    • pp.35-41
    • /
    • 2007
  • We proposed an eye gaze tracking system under natural head movements. The system consists of one CCD(charge-coupled device) camera and two front-surface mirrors. The mirrors rotate to follow head movements in order to keep the eye within the view of the camera. However, the mirror controller cannot guarantee the fast head movements, because the frame rate is generally 30Hz. To overcome this problem, we applied Kalman filter to estimate next eye position from the current eye image. In the results, our system allowed the subjects head to move 60cm horizontally and 40cm vertically, with the head movement speed about 55cm/sec and 45cm/sec, respectively. And spatial gate resolutions were about 4.5 degree and 5.0 degree, respectively, and the gaze estimation accuracy was 92% under natural head movements.

Recent Morphological Changes off the Shoreface of Jinwoodo and Sinjado in the Nakdong River Estuary: 2007-2012 (낙동강 하구역 진우도와 신자도 전면의 최근 지형 변화: 2007년-2012년)

  • Park, Jinku;Khim, Boo-Keun;Lee, Hee Jun;Lee, Sang Ryong
    • Ocean and Polar Research
    • /
    • v.36 no.2
    • /
    • pp.87-101
    • /
    • 2014
  • Recently, more attention has been paid to the geomorphological changes in the Nakdong River Estuary, because those changes are caused by artificial activities including weirs, reclamation and construction. In order to analyze quantitatively the recent geomorphological variability in the Nakdong River Estuary, we surveyed the depth and elevation of submarine topography near Jinwoodo and Sinjado from March 2007 to February 2012. A statistical method (based on Digital Shoreline Analysis System) and an Empirical Orthogonal Functions method were used to evaluate the morphological changes. According to the statistical variables (DCE, NDC, EPR, LRR), the highest amount and rate of accumulation were recorded around the Gadeokdo whereas the greatest amount of erosion appeared around the coast off the eastern part of Sinjado. In particular, a dynamic variation of morphology was clearly observed in the vicinity of the sub-tidal channel located between Jinwoodo and Sinjado, which seems to be attributable to channel migration. As a result of the EOF method, the first mode (48.7%) is most closely related to the pattern of morphological variability that might be associated with the westerly movement of sediment by longshore current. The spatial variability of the second mode (16.6%) was high in the shoreface of Sinjado, showing a 4-year periodicity of temporal variability. The strong correlation (coefficient 0.73) between the time coefficient and suspended sediment discharge from Nakdong River emphasizes the role of sediment discharge to deposition in this area. The spatial variability of the third mode (11.3%) was distributed mainly around the coast off the eastern part of Sinjado, which is related to the movement of the coastline of Sinjado. Based on the last 5 year's data, our results suggest that the study area is characterized on the whole by a depositional pattern, but the extent of sedimentation is different locally.

Real-time Imaging of Inositol 1,4,5-trisphosphate Movement in Mouse Salivary Gland Cells

  • Hong, Jeong-Hee;Lee, Syng-Ill;Shin, Dong-Min
    • International Journal of Oral Biology
    • /
    • v.33 no.4
    • /
    • pp.125-129
    • /
    • 2008
  • Inositol 1,4,5-trisphosphate ($IP_3$) plays an important role in the release of $Ca^{2+}$ from intracellular stores into the cytoplasm in a variety of cell types. $IP_3$ translocation dynamics have been studied in response to many types of cell signals. However, the dynamics of cytosolic $IP_3$ in salivary acinar cells are unclear. A green fluorescent protein (GFP)-tagged pleckstrin homology domain (PHD) was constructed and introduced into a phospholipase C ${\delta}1$ (PLC ${\delta}1$) transgenic mouse, and then the salivary acinar cells were isolated. GFP-PHD was heterogeneously localized at the plasma membrane and intracellular organelles in submandibular gland and parotid gland cells. Application of trypsin, a G protein-coupled receptor activator, to the two types of cells caused an increase in GFP fluorescence in the cell cytoplasm. The observed time course of trypsin-evoked $IP_3$ movement in acinar cells was independent of cell polarity, and the fluorescent label showed an immediate increase throughout the cells. These results suggest that GFP-PHD in many tissues of transgenic mice, including non-cultured primary cells, can be used as a model for examination of $IP_3$ intracellular dynamics.

Development of a Human Motion Analyzer (인체 동작 분석기의 개발)

  • 김민기;김성호
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.217-222
    • /
    • 1995
  • We propose some applications of image processing techniques to extract quantitative measurements by using a camera system developed in Korea university and Catholic Medical School. From now on the system will be called as KCMOTION. The purpose of this study is to provide basic kinematic and kinetic data for the analysis of human movements and to find the clinical usefulness and reliability of the proposed motion analysis system. Two tests, sit-to-stand (STS) movements and pendulum test, are conducted by the system. The aims of the tests are to identify variability and reliability of KCMOTION to give some quantitative comparisons to the other systems. The result of STS movement are compared to the LOCUS IIID motion analyzer by the ratio of maximum flexion movement per body weight to the actual maximum flexion extension torque per body weight. That result in 29 % and 33 % for hip and knee joint, respectively in KCMOTION and 27 % and 30 % in LOCUS IIID System. The results of the pendulum movements are compared to that of using Cybex and Electrogoniometer with relaxation index, amplitude ratio, swing number and swing time. The results of relaxation index and amplitude ratio of the KCMOTION are between those of the Cybex and Electrogoniometer. We also observed that the KCMOTION detect more natural movement, from the results of swing number and time.

  • PDF

The Differences in the Ski Carving Turn Motion According to Level of Exper tise (스키 카빙턴 동작 시 기술 수준에 따른 동작의 차이 연구)

  • Eun, Seon-Deok;Hyun, Moo-Sung
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.3
    • /
    • pp.319-325
    • /
    • 2010
  • The purpose of this research was to investigate the differences in the ski carving turn motion according to level of expertise. The posture and movement of 6 skiers nearby the fall-line was evaluated with a biomechanical approach focusing the rotational mechanics. The slope was at an angle of $9^{\circ}$ and the following variables were measured and calculated: tangential velocity, change of COM height after passing fall-line, width between feet, angle between upper body and thigh, trunk angle, average radius of curvature and average centripetal force. The expert skiers minimized their center of mass height movement and maintained the width of between their feet after the passing the fall-line in comparison with the beginners and intermediate skiers. The experts restrained themselves from pushing their upper body downward after the turn to maximize the centripetal force. The experts in comparison with the beginners and intermediate skiers during the turn didn't have to reduce their radius of curvature to maintain a high centripetal force. It was concluded, that the most important factor affecting the centripetal force, was for the beginners and intermediate skiers, to minimize their movement while using the appropriate amount of edging.

Movement Pattern Recognition of Medaka for an Insecticide: A Comparison of Decision Tree and Neural Network

  • Kim, Youn-Tae;Park, Dae-Hoon;Kim, Sung-Shin
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.7 no.1
    • /
    • pp.58-65
    • /
    • 2007
  • Behavioral sequences of the medaka (Oryzias latipes) were continuously investigated through an automatic image recognition system in response to medaka treated with the insecticide and medaka not treated with the insecticide, diazinon (0.1 mg/l) during a 1 hour period. The observation of behavior through the movement tracking program showed many patterns of the medaka. After much observation, behavioral patterns were divided into four basic patterns: active-smooth, active-shaking, inactive-smooth, and inactive-shaking. The "smooth" and "shaking" patterns were shown as normal movement behavior. However, the "shaking" pattern was more frequently observed than the "smooth" pattern in medaka specimens that were treated with insecticide. Each pattern was classified using classification methods after the feature choice. It provides a natural way to incorporate prior knowledge from human experts in fish behavior and contains the information in a logical expression tree. The main focus of this study was. to determine whether the decision tree could be useful for interpreting and classifying behavior patterns of the medaka.

Effects of Transcutaneous Electrical Nerve Stimulation depending on Frequency and Intensity for Postural Sway during Sit to Stand with Stroke Patients

  • Byun, Dong-Uk;Shin, Won-Seob
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.3
    • /
    • pp.136-142
    • /
    • 2013
  • Purpose: The application of transcutaneous electrical nerve stimulation (TENS) is beneficial for joint movements, inhibition of spasticity, and the improvement of walking ability in patients with chronic hemiplegia. This study aimed to identify the effect of the application of TENS to the knee extensor on the affected side with respect to postural-sway distance and velocity during the sit-to stand movement. Methods: We included 19 patients with post-stroke hemiplegia in this study. They underwent measurements during the sit-to stand movement on a force plate with 5 different stimulation dosages applied over 7 s:No TENS, high-frequency and high intensity TENS, high-frequency and low intensity TENS, low-frequency and high intensity TENS, and low-frequency and low intensity TENS The 5 different condition were administered in random order. Results: The group that received TENS application exhibited a significant decrease in path length and average velocity of center of pressure (COP) displacement compared with the group that did not receive TENS application. TENS dosage at low frequency (3Hz) and high intensity yielded a significant decrease in path length, average velocity, mediolateral distance and anteroposterior distance of COP displacement (p<0.05). Conclusion: Our results demonstrated the effectiveness of the application of low-frequency TENS on STS performance. These findings provide useful information on the application of TENS for the reduction of postural sway during the sit-to-stand movement after stroke.

The Relationship between Functional Movement Screen and Ankle Dysfunctions with Chronic Ankle Instability

  • Choi, Ho-Suk;Shin, Won-Seob;Shim, Jae-Kwang;Choi, Sung-Jin;Bang, Dae-Hyouk
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.6
    • /
    • pp.459-463
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the correlations between functional movement screen (FMS) and ankle dysfunctions in subjects with chronic ankle instability (CAI). Methods: This study was a cross-sectional study of 20 participants with CAI. The ankle dorsiflexion range of motion (ROM), Foot and Ankle Disability Index (FADI), center of pressure (COP) path length, and COP velocity for ankle dysfunction were measured in all the subjects. All the subjects underwent the FMS concerned with ankle functions consisted of deep squats, hurdle steps and in-line lunges. The Spearman rank-order correlation coefficient was used to determine relationship between the ankle ROM, FADI, COP and FMS. Results: The results of the deep squat and in-line lunge exercises revealed a significant correlation with the ankle dorsiflexion ROM, FADI, COP path length, and COP velocity. The hurdle step showed no correlation with the ankle dorsiflexion ROM and FADI but a significant relationship with the COP path length and COP velocity. Conclusion: The results of this study showed that relationship deep squat and in-line lunge and it is suggested that an assessment tool using ankle dorsiflexion ROM and ankle instability would be clinically effective.

march5 Governs the Convergence and Extension Movement for Organization of the Telencephalon and Diencephalon in Zebrafish Embryos

  • Jung, Jangham;Choi, Issac;Ro, Hyunju;Huh, Tae-Lin;Choe, Joonho;Rhee, Myungchull
    • Molecules and Cells
    • /
    • v.43 no.1
    • /
    • pp.76-85
    • /
    • 2020
  • MARCH5 is a RING finger E3 ligase involved in mitochondrial integrity, cellular protein homeostasis, and the regulation of mitochondrial fusion and fission. To determine the function of MARCH5 during development, we assessed transcript expression in zebrafish embryos. We found that march5 transcripts were of maternal origin and evenly distributed at the 1-cell stage, except for the mid-blastula transition, with expression predominantly in the developing central nervous system at later stages of embryogenesis. Overexpression of march5 impaired convergent extension movement during gastrulation, resulting in reduced patterning along the dorsoventral axis and alterations in the ventral cell types. Overexpression and knockdown of march5 disrupted the organization of the developing telencephalon and diencephalon. Lastly, we found that the transcription of march5 was tightly regulated by the transcriptional regulators CHOP, C/EBPα, Staf, Znf143a, and Znf76. These results demonstrate the essential role of March5 in the development of zebrafish embryos.

Vibration Reduction of Chip-Mount System (칩 마운트 시스템의 진동 경감)

  • 임경화;장헌탁
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.8
    • /
    • pp.331-337
    • /
    • 2001
  • The purpose of this study is to analyze the principal causes of vibration problem and find out the method of vibration reduction in a chip-mount system. The principal causes are investigated through measurements of vibration spectrum and model parameters. Modal parameters are obtained by using an experimental model test. Based on the model parameters from experiments. a model of finite element method is formulated. The model presents effective redesign of increasing the natural frequencies in order to reduce the vibration of a chip-mount system. Further, through computer simulation for the behavior of head to be main vibration source, the best acceleration pattern of head movement can be verified to achieve effective head-positioning and reduce the vibration due to head movement.

  • PDF