• 제목/요약/키워드: Natural Breathing

검색결과 55건 처리시간 0.033초

Effects of Intra-abdominal Pressure with Visual Feedback on Muscle Activation of Upper Trapezius and Sternomastoid during Forced Inspiration in Individuals with Costal Respiration

  • Kim, Kwang-Su;Shin, Hwa-Kyung
    • The Journal of Korean Physical Therapy
    • /
    • 제32권2호
    • /
    • pp.75-79
    • /
    • 2020
  • Purpose: This study analyzed the immediate effects of intra-abdominal pressure with visual feedback on the muscle activation of the upper trapezius and sternomastoid during natural inspiration and forced inspiration in individuals with costal respiration. Methods: The eighteen individuals with upper costal breathing pattern participated in this study. Surface electromyography was used to analyze the muscle activity of the upper trapezius and sternomastoid during natural inspiration and forced inspiration before and after intra-abdominal pressure. Results: A significant difference in muscle activation was observed with the muscle type, inspiration type, and test session (p<0.05). The muscle activities of the sternomastoid and upper trapezius decreased significantly during forced inspiration after intra-abdominal pressure training (p<0.05). On the other hand, there was no significant difference during natural inspiration in both muscles (p>0.05). A comparison of the difference between the pre-test and post-test during forced inspiration revealed the upper trapezius to be significantly larger than the sternomastoid (p<0.05). No significant difference was noted during natural inspiration (p>0.05). Conclusion: The intra-abdominal pressure has positive effects on correcting the breathing patterns in individuals with costal respiration.

A generalized algorithm for the study of bilinear vibrations of cracked structures

  • Luo, Tzuo-Liang;Wu, James Shih-Shyn;Hung, Jui-Pin
    • Structural Engineering and Mechanics
    • /
    • 제23권1호
    • /
    • pp.1-13
    • /
    • 2006
  • Structural cracks may cause variations in structural stiffness and thus produce bilinear vibrations to structures. This study examines the dynamic behavior of structures with breathing cracks. A generalized algorithm based on the finite element method and bilinear theory was developed to study the influence of a breathing crack on the vibration characteristic. All the formulae derived in the time domain were applied to estimate the period of the overall bilinear motion cycle, and the contact effect was considered in the calculations by introducing the penetration of the crack surface. Changes in the dynamic characteristics of cracked structures are investigated by assessing the variation of natural frequencies under different crack status in either the open or closed modes. Results in estimation with vibrational behavior variation are significant compared with the experimental results available in the literature as well as other numerical calculations.

수동급기 직접 메탄올 연료전지의 동적 모델 (Dynamic Model of a Passive Air-Breathing Direct Methanol Fuel Cell)

  • 하승범;장익황;차석원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.33-36
    • /
    • 2008
  • The transient behavior of a passive air breathing direct methanol fuel cell (DMFC) operated on vapor-feeding mode is studied in this paper. It generally takes 30 minutes after starting for the cell response to come to its steady-state and the response is sometimes unstable. A mathematical dynamic one-dimensional model for simulating transient response of the DMFC is presented. In this model a DMFC is decomposed into its subsystems using lumped model and divided into five layers, namely the anodic diffusion layer, the anodic catalyst layer, the proton exchange membrane (PEM), the cathodic catalyst layer and the cathodic diffusion layer. All layers are considered to have finite thickness, and within every one of them a set of differential-algebraic governing equations are given to represent multi-components mass balance, such as methanol, water, oxygen and carbon dioxide, charge balance, the electrochemical reaction and mass transport phenomena. A one-dimensional, isothermal and mass transport model is developed that captures the coupling between water generation and transport, oxygen consumption and natural convection. The single cell is supplied by pure methanol vapor from a methanol reservoir at the anode, and the oxygen is supplied via natural air-breathing at the cathode. The water is not supplied from external source because the cell uses the water created at the cathode using water back diffusion through nafion membrane. As a result of simulation strong effects of water transport were found out. The model analysis provides several conclusions. The performance drop after peak point is caused by insufficiency of water at the anode. The excess water at the cathode makes performance recovery impossible. The undesired crossover of the reactant methanol through the PEM causes overpotential at the cathode and limits the feeding methanol concentration.

  • PDF

수동급기 직접 메탄올 연료전지의 유로에 따른 성능 평가 (Performance evaluation by flow channel effect for a passive air-breathing Direct Methanol Fuel Cell)

  • 장익황;하승범;차석원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.45-48
    • /
    • 2008
  • This paper presents a passive air-breathing direct methanol fuel cell (DMFC) which has been designed and tested. The single cell is fuelled by methanol vapor that is supplied through flow channel from a methanol reservoir at the anode, and the oxygen is supplied via natural air-breathing at the cathode. The methods for supplying the methanol vapor to the single cell were parallel channel and chamber. This research investigates various methods to identify the effects of using flow channels for providing the methanol vapor at the anode, and the opening ratio between the inlet and outlet ports for the methanol flow at the anode. The best flow channel condition for passive DMFC was a chamber, and the opening ratio was 0.8. Under these conditions, the peak power was 10.2mW/$cm^2$ at room temperature and ambient pressure. The key issues for the Passive DMFCs for using methanol vapor are that sufficient methanol needs to be supplied using a large as possible opening ratio. However, it is shown that the performance of the passive DMFC, which has a channel at the anode,is low due to the low differential pressure and insufficient methanol supply rate.

  • PDF

Effects of Lower Rib Expansion Limitation on Maximal Respiratory Pressure and Abdominal Muscle Activity During Maximal Breathing in Healthy Subjects

  • Lee, Gyu-wan;Yoon, Tae-Lim;Lee, Young-jung;Kim, Ki-song;Yi, Chung-hwi
    • The Journal of Korean Physical Therapy
    • /
    • 제32권6호
    • /
    • pp.394-399
    • /
    • 2020
  • Purpose: The aim of this study was to determine the effects of lower rib cage lateral expansion limitation on the maximal inspiratory and expiratory pressures and on abdominal muscle activity during maximal respiratory breathing in healthy subjects. Methods: Fifteen healthy male subjects voluntarily participated in this cross-sectional study. During maximal breathing, maximal inspiratory and expiratory pressures were measured, and abdominal muscle activity was determined with using surface electromyography. Also, the measurement was repeated with using a non-elastic belt to the lower rib cage for limiting of lateral expansion. A Wilcoxon signed-rank test was performed for obtaining the statistical difference with a significance level of 0.05. Results: The findings of this study are as follows: 1) There were no significant differences in maximal inspiratory and expiratory pressure with and without lower rib cage lateral expansion (p>0.05), 2) There was no significant difference in abdominal muscle activity during the maximal inspiratory phase (p>0.05). However, right external oblique muscle activity decreased significantly during maximum exhalation with lower rib expansion limitation (p<0.05). Conclusion: The results of the current study indicate that a non-elastic belt was effective in decreasing right external oblique muscle activity during forced expiratory breathing in healthy subjects.

소아치과 환자의 깊은 진정시 호기가스 제거 방법에 따른 호흡대역에서 Nitrous Oxide 농도 변화 (THE NITROUS OXIDE CONCENTRATION IN BREATHING ZONE ACCORDING TO SCAVENGING METHODS DURING DEEP SEDATION OF PEDIATRIC DENTAL PATIENTS)

  • 이충원;윤형배
    • 대한소아치과학회지
    • /
    • 제30권1호
    • /
    • pp.124-131
    • /
    • 2003
  • 최근 치과영역에서 아산화질소(Nitrous Oxide)를 이용한 의식하 진정과 필은 진정의 임상 적용이 증가함에 따라 수술실 또는 진료실 환경이 아산화질소로 오염될 수 있다. 비록 낮은 농도일지라도 장기간 아산화질소에 노출 시 자연유산의 증가, 기형아 출산 증가, 말초신경염 및 운동신경 장애 등과 같은 부작용을 초래하는 것으로 알려져 있다. 호흡시 흡입 공기의 구성성분의 변화를 줄 수 있는 구강 입구로부터 반경 12 inch 이내 영역인 호흡대역(Breathing zone)에서 아산화질소 농도는 치료자에게 영향을 주게된다. 소아 환자에게 주로 적용되는 깊은 진정시는 환자의 구호흡양에 따라서 호흡대역에서 아산화질소의 농도에 영향을 주게되므로, 깊은 진정시 구호흡의 증가 원인을 규명하기 위해 잉여가스 배출 방법을 달리하여 호흡대역에서 아산화질소 농도를 측정 비교하여 다음과 같은 결론을 얻었다. 1. 깊은 진정을 시행하는 경우 호흡대역에서 아산화질소의 농도는 공급 가스량 증가에 의한 비기도 저항 증가에 따라 증가하는 양상을 보였다. 호흡대역에서 아산화질소 농도 증가는 구호흡 증가에 의한 것이며 구호흡은 비기도 저항과 관계가 있다 할 수 있다. 즉 비기도 저항 증가는 구호흡의 한 요인이라 할 수 있다. 음압을 사용한 호기가스 배출장치를 사용하여도 NIOSH에서 권장하는 허용치에는 미치지 못하였고 이를 위해서는 팬이나 다른 제거 장치가 함께 사용되어야 한다. 2. 구강편도의 크기는 기도 저항이 적은 경우 즉 음압을 사용하여 호기가스 제거하는 경우 구호흡에 영향을 주었다.

  • PDF

평인(平人)의 호흡맥동(呼吸脈動)과 촌구인영(寸口人迎)에 대한 연구 (Study on Breathing and Pulsation, Chongu and Inyeong of Healthy Man)

  • 이혜연;강정수
    • 대한한의학원전학회지
    • /
    • 제22권4호
    • /
    • pp.1-13
    • /
    • 2009
  • When feeling the pulse, healthy man' pulse is the criterion for diagnosis whether you are a sick person. Healthy man is defined as one who is harmonious and not sick in sympathy with natural order. Among the factors for being Healthy man, breathing and pulsation, Chon-gu(寸口) and Inyeong(人迎) are most closely connected with the representative methods of feeling the pulse which are used currently. According to "Hwangjenaegyeong(黃帝內經)" on breathing and pulsation, the pulse beats twice per a breathing-in and a breathing-out each. And for a specific breathing, it beats 5 times including the remnant with a big breath. That the pulse beats twice means that it beats not only twice, but also regularly and repeatedly. The remnant is related to the meaning on a leap month, 5-time beating during a breath is connected with the contents of Osipyeong(五十營). A human is not always in stable and sticks to balance continuously with changes under the circumstances. So when it comes to a criterion how to measure the pulsation frequency, breathing is much more reasonable than pulsation and breathing calculated for a minute. According to "Hwangjenaegyeong(黃帝內經)", Healthy man is the person of whose Chon-gu and Inyeong are in order and much the same in response to each other. Although there is a minor difference in the meaning of term between Chon-gu and Gigu(氣口), Maekgu(脈口) in originally, it is used as almost same meaning when Chon-gu is used in opposition to Inyeong. Afterwards, depending on medical men, around neck or Chon-gu of the left hand are measured for Inyeong. However, Inyeong described in "Naegyeong(內經)" is Jokyangmyeong(足陽明) and it means the Hyeol(穴) around neck where the pulse beats, it looks like about the carotid area. Chon-gu is fall under Eum(陰) and Inyeong(人迎) is fall under Yang(陽). Therefore Chon-gu is continuous with eumgyeong(陰經) and Inyeong is continuous with yanggyeong(陽經). In addition, the pulse and the four seasons meet each other and Inyeong is a little stronger in spring summer and Chongu is a little stronger in fall winter.

  • PDF

T-spine exhalation technique과 자연스런 호흡 상태에서 촬영하는 T-spine breathing technique의 정량적 평가 (Evaluation of quantitative on T-spine exhalation technique and T-spine breathing technique of natural breathing)

  • 손순룡;최관우;민정환;손진현;김기원;정재홍;정회원
    • 한국산학기술학회논문지
    • /
    • 제14권9호
    • /
    • pp.4429-4436
    • /
    • 2013
  • 흉추 측면검사에서 기존의 T-spine exhalation technique (TET)과 환자의 자연스런 호흡 상태에서 촬영하는 T-spine breathing technique (TBT)의 대조도 잡음 비와 신호 대 잡음 비를 측정하여 적절한 검사기법을 제시하고자 하였다. 2012년 6월부터 2012년 11월까지 척추질환으로 본원을 내원하여 흉추 측면검사를 시행한 환자 53명을 대상으로 하였으며, 동일한 환자를 대상으로 측면 선 자세에서 기존의 TET와 TBT를 병행하였다. 화질 평가는 흉추 측면검사의 평가요소 중 5곳(극돌기, 추궁근, 추체, 추간공, 추간)을 Image J 프로그램을 이용하여 관심영역을 정하고 화소의 평균과 대조 농도와의 차이를 구하여 대조도 잡음 비를 측정하여 비교하였다. 또한 추체에 관심영역을 정하여 화소의 평균과 표준편차를 구하고 신호 대 잡음 비를 측정하여 비교하였다. TET와 TBT방법으로 촬영한 영상을 대조도 잡음 비와 신호 대 잡음 비에서 비교한 결과, TBT방법이 추궁근, 추체, 추간공, 추간의 구조에서 우수하게 나타났으며, 통계적으로 매우 유의하였다(p<.01). 기존의 심호기법에 비해 TBT방법으로 촬영한 영상은 우수한 화질을 제공하므로 이를 토대로 임상에 혼재되어 있는 흉추 측면 검사법을 재정립하고, 여러 의료기관에 적용할 경우, 유용성이 크다고 사료된다.

초음속 유도무기 지상 시험용 가열기 개념 설계 (Concept Design on Heating System for Supersonic Air-Breathing Engine Test Facility)

  • 한풍규;남궁혁준;이경훈;김영수
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제26회 춘계학술대회논문집
    • /
    • pp.321-326
    • /
    • 2006
  • 초음속 유도무기에 사용되고 있는 공기흡입 추진기관의 지상 연소시험에서 요구되는 700K-6바의 공기를 공급하기 위한 Vitiated형 공기 가열기에 대한 개념설계를 수행하였다. 본 가열기는 여분의 기체 산소와 공기를 혼합하는 예혼합기, 예혼합 기체와 연료를 혼합시키는 혼합기, 점화기를 포함하는 연소실과 수축팽창 노즐, 그리고 디퓨저로 구성하였다. 가열기에 사용된 연료는 천연가스이며, 유동해석을 통해 가열기의 각 구성요소의 성능을 파악하였으며, 점화 후 화염유지가 이루지는 것을 해석적으로 확인하였다.

  • PDF

도시 자연공원의 중요도 평가 (An Evaluation of the Importance of Urban Natural Parks)

  • 심준영;김유일
    • 한국조경학회지
    • /
    • 제33권6호
    • /
    • pp.12-21
    • /
    • 2006
  • This study aims to examine what factors park users value in urban natural parte and to find ways to elevate user satisfaction for the creation and usage of an urban natural park To achieve this, the study relied on two methods: the descriptive method of researching publications and related scholastic writings, and the empirical study method including a survey of present condition and interviews with users. 'Breathing fresh air' and 'cleanliness' were the most important items and play facilities, cultural facilities, and landscape facilities were of lower orders of importance. This suggests that the 'sense of nature' is more important than functional facilities in urban natural parte. The importance of urban natural parks and the satisfaction visitors felt in them were measured, with mean results of 5.86 and 3.88, respectively, in terms of living surroundings. The impotance rating is higher than the satisfaction rating. Factor analysis resulted in six factors: benefits sought facilities for use, pleasant use, safety, accessibility, and management. Correlation and regression analysis showed only one positively correlated factor: benefits sought, suggesting that people recognize the importance of urban natural Parte through the benefits they gain in them and the satisfaction they find in urban parte depends on utilizing facilities. Therefore, in urban natural parks, people will find greater satisfaction through pursuit of the benefits they are seeking; improvements to park facilities should address the benefits that park users are seeking.