A Machine Learning-based Real-time Monitoring System for Classification of Elephant Flows on KOREN

  • Akbar, Waleed;Rivera, Javier J.D.;Ahmed, Khan T.;Muhammad, Afaq;Song, Wang-Cheol
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제16권8호
    • /
    • pp.2801-2815
    • /
    • 2022
  • With the advent and realization of Software Defined Network (SDN) architecture, many organizations are now shifting towards this paradigm. SDN brings more control, higher scalability, and serene elasticity. The SDN spontaneously changes the network configuration according to the dynamic network requirements inside the constrained environments. Therefore, a monitoring system that can monitor the physical and virtual entities is needed to operate this type of network technology with high efficiency and proficiency. In this manuscript, we propose a real-time monitoring system for data collection and visualization that includes the Prometheus, node exporter, and Grafana. A node exporter is configured on the physical devices to collect the physical and virtual entities resources utilization logs. A real-time Prometheus database is configured to collect and store the data from all the exporters. Furthermore, the Grafana is affixed with Prometheus to visualize the current network status and device provisioning. A monitoring system is deployed on the physical infrastructure of the KOREN topology. Data collected by the monitoring system is further pre-processed and restructured into a dataset. A monitoring system is further enhanced by including machine learning techniques applied on the formatted datasets to identify the elephant flows. Additionally, a Random Forest is trained on our generated labeled datasets, and the classification models' performance are verified using accuracy metrics.

Optimal Monitoring Intervals and MDA Requirements for Routine Individual Monitoring of Occupational Intakes Based on the ICRP OIR

  • Ha, Wi-Ho;Kwon, Tae-Eun;Jin, Young Woo
    • Journal of Radiation Protection and Research
    • /
    • 제45권2호
    • /
    • pp.88-94
    • /
    • 2020
  • Background: The International Commission on Radiological Protection (ICRP) has recently published report series on the occupational intakes of radionuclides (OIR) for internal dosimetry of radiation workers. In this study, the optimized monitoring program including the monitoring interval and the minimum detectable activity (MDA) of major radionuclides was suggested to perform the routine individual monitoring of internal exposure based on the ICRP OIR. Materials and Methods: The derived recording levels and the critical monitoring quantities were reviewed from international standards or guidelines by the International Atomic Energy Agency (IAEA), the International Organization for Standardization (ISO), and the European Radiation Dosimetry Group (EURADOS). The OIR data viewer provided by ICRP was used to evaluate the monitoring intervals and the MDA, which are derived from the reference bioassay functions and the dose coefficients. Results and Discussion: The optimal monitoring intervals were determined taking account of two requirement conditions on the potential intake underestimation and the MDA values. The MDA requirement values of the selected radionuclides were calculated based on the committed effective dose from 0.1 mSv to 5 mSv. The optimized routine individual monitoring program was suggested including the optimal monitoring intervals and the MDA requirements. The optimal MDA values were evaluated based on the committed effective dose of 0.1 mSv. However, the MDA can be adjusted considering the practical operation of the routine individual monitoring program in the nuclear facilities. Conclusion: The monitoring intervals and the MDA as crucial factors for the routine monitoring were described to suggest the optimized routine individual monitoring program of the occupational intakes. Further study on the alpha/beta-emitting radionuclides as well as short lived gamma-emitting nuclides will be necessary in the future.

A sampling and estimation method for monitoring poultry red mite (Dermanyssus gallinae) infestation on caged-layer poultry farms

  • Oh, Sang-Ik;Park, Ki-Tae;Jung, Younghun;Do, Yoon Jung;Choe, Changyong;Cho, Ara;Kim, Suhee;Yoo, Jae Gyu
    • Journal of Veterinary Science
    • /
    • 제21권3호
    • /
    • pp.41.1-41.12
    • /
    • 2020
  • Background: The poultry red mite, Dermanyssus gallinae, is a serious problem in the laying hen industry worldwide. Currently, the foremost control method for D. gallinae is the implementation of integrated pest management, the effective application of which necessitates a precise monitoring method. Objectives: The aim of the study was to propose an accurate monitoring method with a reliable protocol for caged-layer poultry farms, and to suggest an objective classification for assessing D. gallinae infestation on caged-layer poultry farms according to the number of mites collected using the developed monitoring method. Methods: We compared the numbers of mites collected from corrugated cardboard traps, regarding with length of sampling periods, sampling sites on cage, and sampling positions in farm buildings. The study also compared the mean numbers of mites collected by the developed method with the infestation levels using by the conventional monitoring methods in 37 caged-layer farm buildings. Results: The statistical validation provided the suitable monitoring method that the traps were installed for 2 days on feed boxes at 27 sampling points which included three vertical levels across nine equally divided zones of farms. Using this monitoring method, the D. gallinae infestation level can be assessed objectively on caged-layer poultry farms. Moreover, the method is more sensitive than the conventional method in detecting very small populations of mites. Conclusions: This method can be used to identify the initial stages of D. gallinae infestation in the caged-layer poultry farms, and therefore, will contribute to establishment of effective control strategies for this mite.

Real-time Monitoring of Ethernet Passive Optical Network Using Burst-mode FBGs

  • Binh, Nguyen Khac;Choi, Su-il
    • Current Optics and Photonics
    • /
    • 제4권3호
    • /
    • pp.186-192
    • /
    • 2020
  • This paper describes a real-time monitoring system in Ethernet passive optical networks (EPON) that uses burst-mode fiber Bragg grating (FBG) optical sensors. The FBG interrogation unit in the optical line terminal (OLT) transmits the monitoring wavelength to optical network units (ONUs). The FBG sensor unit in each ONU returns a burst-mode monitoring signal to the OLT. As the system applies time division multiple access (TDMA), a uniform Bragg wavelength can be used to monitor the EPON system. The FBG interrogation unit analyzes the received burst-mode monitoring signals and outputs fault information on the ONU branches in EPON. The simulation results show the effectiveness of the proposed monitoring system based on TDMA. In addition, we compared the proposed TDMA-based monitoring system with a WDMA-based monitoring system.

Implementation of Spectrum Analysis System for Vibration Monitoring

  • Nguyen, Thanh Ngoc;Jeon, Taehyun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제11권2호
    • /
    • pp.27-30
    • /
    • 2019
  • Factory monitoring systems are gaining importance in wide areas of industry. Especially, there have been many efforts in implementation of vibration measurement and analysis for monitoring the status of rotating machines. In this paper, a digital signal processor (DSP) based monitoring system dedicated to the vibration monitoring and analysis on rotating machines is discussed. Vibration signals are acquired and processed for the continuous monitoring of the machine status. Time domain signals and fast Fourier transform (FFT) are used for vibration analysis. All of the signal processing procedures are done in the DSP to reduce the production and maintenance cost. The developed system could also provide remote and mobile monitoring capabilities to operator via internet connection. This paper describes the overview of the functional blocks of the implemented system. Test results based on signals from small-size single phase motors are discussed for monitoring and defect diagnosis of the machine status.

제어흐름 에러 탐지를 위한 분리형 시그니처 모니터링 기법 (Separate Signature Monitoring for Control Flow Error Detection)

  • 최기호;박대진;조정훈
    • 대한임베디드공학회논문지
    • /
    • 제13권5호
    • /
    • pp.225-234
    • /
    • 2018
  • Control flow errors are caused by the vulnerability of memory and result in system failure. Signature-based control flow monitoring is a representative method for alleviating the problem. The method commonly consists of two routines; one routine is signature update and the other is signature verification. However, in the existing signature-based control flow monitoring, monitoring target application is tightly combined with the monitoring code, and the operation of monitoring in a single thread is the basic model. This makes the signature-based monitoring method difficult to expect performance improvement that can be taken in multi-thread and multi-core environments. In this paper, we propose a new signature-based control flow monitoring model that separates signature update and signature verification in thread level. The signature update is combined with application thread and signature verification runs on a separate monitor thread. In the proposed model, the application thread and the monitor thread are separated from each other, so that we can expect a performance improvement that can be taken in a multi-core and multi-thread environment.

A Study on the Distribution Characteristics of Sulfur Compounds in Ambient air using Continuous Monitoring Method in Incheon Area

  • Seo, Seok-Jun;Lim, Yong-Jae;Hong, You-deok;Park, Geon-Young
    • 통합자연과학논문집
    • /
    • 제8권2호
    • /
    • pp.128-134
    • /
    • 2015
  • This paper focuses on the applicability of a continuous monitoring method on trace sulfur compounds in the ambient air by TD and GC/PFPD. The target compounds for monitoring include H2S(hydrogen sulfide), Methyl mercaptan, Dimethyl Sulfide, and Dimethyl disulfide. The result of QA/QC on monitoring instruments satisfies all the standards of Odor Measurement and Analysis Method, showing that the reproductivity of the compounds by concentration is within 10%, linearity is above 0.98 of a correlation efficient, method detection limit is 0.16 ppb by MM standard, and recovery rate is over 70%. Monitoring was conducted for two years from March 2006 to February 2008. As a result of the monitoring, the average concentration of H2S was 0.08 ppb, with the maximum concentration at 16.15 ppb. The result indicates that it is reasonable to do continuous monitoring as there appears a spontaneous event of high concentration by the condition of the site during monitoring odor-causing substances. Therefore, it is suggested that the continuous monitoring method used in this paper is appropriate to identify the characteristics of sudden occurrence and concentration variations of sulfur compounds.

Wireless structural health monitoring of stay cables under two consecutive typhoons

  • Kim, Jeong-Tae;Huynh, Thanh-Canh;Lee, So-Young
    • Structural Monitoring and Maintenance
    • /
    • 제1권1호
    • /
    • pp.47-67
    • /
    • 2014
  • This study has been motivated to examine the performance of a wireless sensor system under the typhoons as well as to analyze the effect of the typhoons on the bridge's vibration responses and the variation of cable forces. During the long-term field experiment on a real cable-stayed bridge in years 2011-2012, the bridge had experienced two consecutive typhoons, Bolaven and Tembin, and the wireless sensor system had recorded data of wind speeds and vibration responses from a few survived sensor nodes. In this paper, the wireless structural health monitoring of stay cables under the two consecutive typhoons is presented. Firstly, the wireless monitoring system for cable-stayed bridge is described. Multi-scale vibration sensor nodes are utilized to measure both acceleration and PZT dynamic strain from stay cables. Also, cable forces are estimated by a tension force monitoring software based on vibration properties. Secondly, the cable-stayed bridge with the wireless monitoring system is described and its wireless monitoring capacities for deck and cables are evaluated. Finally, the structural health monitoring of stay cables under the attack of the two typhoons is described. Wind-induced deck vibration, cable vibration and cable force variation are examined based on the field measurements in the cable-stayed bridge under the two consecutive typhoons.

Real-time structural damage detection using wireless sensing and monitoring system

  • Lu, Kung-Chun;Loh, Chin-Hsiung;Yang, Yuan-Sen;Lynch, Jerome P.;Law, K.H.
    • Smart Structures and Systems
    • /
    • 제4권6호
    • /
    • pp.759-777
    • /
    • 2008
  • A wireless sensing system is designed for application to structural monitoring and damage detection applications. Embedded in the wireless monitoring module is a two-tier prediction model, the auto-regressive (AR) and the autoregressive model with exogenous inputs (ARX), used to obtain damage sensitive features of a structure. To validate the performance of the proposed wireless monitoring and damage detection system, two near full scale single-story RC-frames, with and without brick wall system, are instrumented with the wireless monitoring system for real time damage detection during shaking table tests. White noise and seismic ground motion records are applied to the base of the structure using a shaking table. Pattern classification methods are then adopted to classify the structure as damaged or undamaged using time series coefficients as entities of a damage-sensitive feature vector. The demonstration of the damage detection methodology is shown to be capable of identifying damage using a wireless structural monitoring system. The accuracy and sensitivity of the MEMS-based wireless sensors employed are also verified through comparison to data recorded using a traditional wired monitoring system.